Testomat Automatic Hardness Control
Automatic hardness control
The Testomat automatic determines the residual/total hardness via titration. Ideal for the water quality after water softeners, water blender and drinking-water plants.
Testomat ECO
Accurate Titration via piston dosing pump, with display of current measured value.
Two adjustable limits with programmable switch functions.
Technical data:
- max. operating pressure 1-8 bar
- operating temperature 10-40°C,
- automatic time set intervals (0-99 min)
- indicator solution in 500ml bottles
- 230V 50Hz.
- H x W x D = 480 x 380 x 280 cm
- Weight approx. 9,5 kg
- IP rating: IP65
Datasheet
Testomat 2000
The Testomat 2000 can also determine carbonate hardness, the p-value of the water. Two separate water input, to monitor multiple plants.
Technical data:
- max. operating pressure 1-8 bar
- operating temperature 10-40°C,
- automatic time set intervals (0-99 min)
- indicator solution in 500ml bottles
- 230V 50Hz.
- H x W x D = 480 x 380 x 280 cm
- Weight approx. 10,5 kg
- IP rating: IP65
Datasheet
Direct Quotation
For Testomat Eco, 2000
or for Testomat titration liquids
The Testomat Family
- Testomat 2000
Automatically determines the residual or total water hardness, the carbonate hardness, the p-value or the minus-m-value via titration. The 2000 can measure two individual measuring points.
- Testomat 2000 DUO
This analysis instrument enables the measurement of two different parameters simultaneous, e.g. two different measuring ranges for water hardness.
- Testomat 2000 CAL
This Testomat correspond in function and suitability to the Testomat 2000, but has an additional calibration function in order to balance possible interference.
- Testomat Eco
This Testomat is "the good value alternative" for the Testomat 2000, it determines through titration the water hardness from a single measurement point. The Testomat Eco or Testomat 2000 replace the Testomat F-bob
- Testomat 2000 V
This Testomat version, in combination with a 3/2-way-motor operating valve is an easy to use control system for water blending plant
- Testomat 2000 CLT
The process-photometer Testomat 2000 CLT is a wet-chemical online instrument for monitoring the content of total chlorine in the 0–2.5 mg/l (ppm) range and it can be switched to free chlorine.
• Analysis via automatic dosing of 3 reagents; the analysis result is displayed after a reaction time of approx. two minutes
• Application areas: Monitoring of chlorination plants for drinking water or swimming pools– Provides protection for reverse osmosis membranes.
- Testomat 2000 CLF
The process-photometer Testomat 2000 CLF is a wet-chemical online instrument for monitoring the content of free chlorine in the0–2.5 mg/l (ppm) range.
- Testomat 2000 THCL
The process photometer Testomat 2000 THCL determines the content of total chlorine in the 0 to 2.5 mg/l (ppm) range using the colorimetric analysis principle and the existing water hardness via titration.
- Testomat Fe
The process photometer Testomat 2000 Fe is a wet-chemical online monitor for monitoring the content of dissolved iron (II) + (III) in the 0 to 1.0 mg/l (ppm) range using the colorimetric method.
• Dosing of 2 reagents and display of the analysis value after a reaction time of approx. 7 minutes (absolute measuring time without flushing times)
Model | Measuring range° dH | Ambient temperature°C | Operating pressurebar | Water inlet ODmm | Water outlet ODmm | DimensionsB x H x Tmm | WeightKg | Application | |
Silica SiO2 0.3 - 1.2 | 10 - 40 | 0.3 - 1 | 6 | 6 | 364 x 314 x 138 | 4,35 | Sterilisation of hospitals Measuring silica | ![]() | |
0.02 - 3 | 10 - 40 | 0.3 - 1 1 - 4 | 6 | 6 | 364 x 314 x 138 | 4,35 | reverse osmosis pure water galvanization | ![]() | |
0.05 - 25 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9 | water treatment drinking water | ||
0.5 - 10.0 carbonate hardness 1.0 - 20.0 acid capacity | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9 | water treatment swimming pools | ![]() | |
0.05 - 25 | 10 - 40 | 0.3 - 1 1 - 8 | 6 | 12 ID | 380 x 480 x 280 | 9 | water treatment monitoring proceswater drinking water | ![]() | |
0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | water treatment drinking water watersoftening decarbonization desalination boiler houses cooling towers | ||
0.05 - 25 water harness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | water treatment drinking water watersoftening decarbonization desalination boiler houses cooling towers | ||
0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | control water quality pharmaceutical industry | ![]() | |
1.0 - 25 water hardness 1.0 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | water blending process water | ||
0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | difficult water, calcium, biofilms extending life reducing contamination | ||
0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | control of water quality can arise due to oxidizing agents | ||
0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | use two circuits for diferent hardness measurment inlet - outlet | ||
Testomat 2000 DUO CN | 0.05 - 25 water hardness 0.5 - 20 carbonate hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | use two circuits for diferent hardness measurment inlet - outlet | |
free chlorine 0.0 - 0.99 / 1.0 - 2.5 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring chlorination drinking water swimming pool water | ||
free chlorine 0.0 - 0.99 / 1.0 - 2.5 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring chlorination drinking water swimming pool water protection RO membranes | ||
free chlorine 0.0 - 0.99 / 1.0 - 2.5 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring desinfection drinking water process water | ||
0 - 1.88 / 1.0 - 4.7 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring desinfection drinking water process water | ||
free chlorine 0.0 - 0.99 mg/l / 0.25 - 2.50 water hardness | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | dialysis corrosion protection protection RO membranes monitoring drinking water /swimming pools | ||
0 - 2.23 / 2.3 - 5.6 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring dosing disinfectants | ||
chromate 0.0 - 0.99 / 1.0 - 2.0 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring chromate control of waste water | ||
0.0 - 0.65 / 0.7 - 1.0 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitorig removing iron control drinking water | ||
0.0 - 50.0 mg/l | 10 - 45 | 0.3 - 1 1 - 4 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring conditioning cooling and heating | ||
0.0 - 10.0 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | process water water purification waste water treatment | ||
sulfite 0.0 - 9.9 / 10 - 20 mg/l | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring sulfite for oxygen binding boiler water | ||
5 - 150 °KH 2 - 60 °KH | 10 - 45 | 0.3 - 1 1 - 4 | 6 | 6 | 380 x 480 x 280 | 9,5 | alkalinity of coolant circuits | ||
0.05 - 1.0 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring corrosion boiler water decarbonization | ![]() | |
Titromat M2 | 0.05 - 2.0 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | monitoring corrosion boiler water decarbonization | |
2.5 - 50.0 | 10 - 45 | 0.3 - 1 1 - 8 | 6 | 6 | 380 x 480 x 280 | 9,5 | drinking water raw water | ||
Maintenance and service sets ECO
Maintenance Instructions Testomat 2000 & ECO
Maintenance Instructions Testomat 808
Maintenance Instructions Testomat 808 SiO2
For a direct quotation or a Testamat price list, please contact us: Feedback Form or call us on +31 152 610 900
Lenntech (European Head Office)
Distributieweg 3
2645 EG Delfgauw
The Netherlands
Phone: +31 152 610 900
fax: +31 152 616 289
e-mail: [email protected]
Lenntech USA LLC (Americas)
5975 Sunset Drive
South Miami, FL 33143
USA
Phone: +1 877 453 8095
e-mail: [email protected]
Lenntech DMCC (Middle East)
Level 6 - OFFICE #101-One JLT Tower
Jumeirah Lake Towers
Dubai - U.A.E.
Phone: +971 4 429 5853
e-mail: [email protected]