0% found this document useful (0 votes)
317 views2 pages

Magnetic Float Level Transmitter

This document describes a magnetic float level transmitter called the FGT that uses a float and reed switch assembly to continuously measure liquid level through a 4-20mA output signal. It can measure level in tanks for various liquids and has adjustable alarms. The transmitter is calibrated at the factory and consists of a float moving within a guide tube that actuates reed switches to proportionally measure level. It is suitable for applications such as storage tanks, pressurized vessels, and wastewater treatment.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
317 views2 pages

Magnetic Float Level Transmitter

This document describes a magnetic float level transmitter called the FGT that uses a float and reed switch assembly to continuously measure liquid level through a 4-20mA output signal. It can measure level in tanks for various liquids and has adjustable alarms. The transmitter is calibrated at the factory and consists of a float moving within a guide tube that actuates reed switches to proportionally measure level. It is suitable for applications such as storage tanks, pressurized vessels, and wastewater treatment.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Magnetic, Float Operated, Guided Level Transmitter "FGT"

SINCE 1984
It is a simple and reliable technique for continuous level indication and control of any liquid, chemically compatible with the (sensor) material, unaffected by electrical conductivity, temperature, pressure or viscosity. The float is designed for variety of liquids and its unique self cleaning construction is well suited for even sticky or dirty environments with no float hang-ups.

Outstanding Features :
Continuous 'Float type' analog sensor, in materials, resistive to most liquids. Pre calibrated at factory - no field calibration required. 4-20 mA, 2 wire processed output signal. High resolution & repeatability. Liquid level or liquid / liquid interface detection. Adjustable, Multiple Alarm Relays. Customized lengths upto 4 meters. Intrinsically safe option available.

Construction & Operation :


It consists of a float & guide tube assembly in non-magnetic material to achieve undisturbed flux. A chain of closely spaced glass encapsulated reed switches & resistors are placed inside the guide tube (fig 1). During rise and fall of liquid level, the float moves & actuates a reed switch in the chain, through a magnet system within it and develops a proportional voltage. The operation is similar to a sliding resistance potentiometer. The sensed voltage is fed to the transmitter located in the enclosure for conversion to a signal of 420 mA, for use with PLC / DCS or Techtrol loop powered indicator (TLPI) or Techtrol level indicator controllers TLIC, TUIC and T-SCN (fig 2).

(optional)

Specifications:
: GTL - (Top *D T + Bottom *DB ) Min 270 mm (GTL 400 mm) Max 3770 mm (GTL 4000 mm) Resolution : a) Standard 12 mm b) High 6 mm Installation : Top Enclosure : Cast Al w proof to IP 66 or Ex proof to Gr IIA & IIB or IIC Conduit conn : Polyamide, PG 9 or Brass, " NPT Wetted parts : SS304, SS316 or PP, SS304 PVDF coating Float : 60, 75 & 90 Process connections : 2-" or 3" or 4" NB flanged to BS (option ANSI or DIN std) or Triclover flange (sanitary applications) Output : DC 4-20 mA (isolated) or 1 to 5 VDC (optional) or 4-20mA (HART) or RS485 Wiring system : 2 wire Max load : 400 ohms Max temperature : 80C (PP) / 100C (metallic MOC), 150C (optional) Max test pressure : 3 Kg/cm (PP) / 10Kg/cm (metallic MOC) 25 Kg/cm (optional) Special feature : Intrinsically safe to Ex ib Gr IIA-IIB T6 (with zener barrier 24VDC / 110mA) Measuring range (Span)

Construction :
105

Fig. 1
01

135

02 03

TERMINATION

04

Supply : 24VDC, 4-20mA o/p

V/I CONVERTER - + o/p

MEASURING RANGE (mm) GUIDE TUBE LENGTH "GTL"


05 06

MOC

Size (mm) *DT (mm) *DB (mm) Min sp. gr. 30 30 25 70 70 70


100 100

R1 R2 R3 R4

S2 S3 S4 S5

SS316 60 x 130 SS316 75 x 72 SS316 90 x 100


* DT =Top Dead Band

1.0 0.9 0.7 0.8 0.7 0.65

DB
07 01 02 03 04 05 06 07 ENCLOSURE CONDUIT CONN ADAPTER PROCESS CONN GUIDE TUBE FLOAT STOPPER

Float Selection Table :

S1

90 85 85 85

PP

63 x 90 75 x 90 90 x 90

* DB=Bottom Dead Band PP based on water (sp.gr.1) PP

Internal ckt Diagram

DT

ZERO

SPAN

FGT
Wiring
4-20mA DC

Fig. 2
LOAD

Model Identification No. FGT :


Enclosure Cast Al, W.Proof IP-66 x PG9 J Cast Al, Ex-proof Gr.IIA & IIB x "NPT E Cast Al, Ex-proof Gr. IIC x "NPT F Others O Wetted Parts (Float, Flange, Guide tube) SS 304 SS 316 PP Others Float x Flange Size 60 x 2-"NB (max 1.5 mtrs GTL) 75 x 3"NB (max 4 mtrs GTL) 90 x 4"NB (max 4 mtrs GTL) Others Flange Rating ANSI 150# RF Flange BS-10 T 'D' Flange Others Resolution Standard High

x GTL (mm)

+ -

LEVEL INDICATING CONTROLLER/SCANNER


+

24 VDC

TLIC or i/p TSCN or TLPI

N S P O 1 2 3 O 1 2 O S H 1 2 3 4 W I W I D L C U S W C F S O
All dimensions in mm, except specified.

INTRINSICALLY SAFE 4-20mA DC + ZENER - BARRIER -

+ -

Installation :

Fig. 3

NOZZLE PIPE NB (B)

X'MITTER FLANGE CAGE FLANGE

24 VDC

INTERNAL MOUNTING

CC DIST

TANK

Internal mounting

The transmitter is install vertically from top & can be mounted internally & externally to suit the application. External mounting is adopted to overcome limited space within the tank or where mechanical devices like stirrers operate or where isolation tank is required for regular servicing. The transmitter is pre calibrated in the factory and comes ready for installation.

Ordering information : Specify Model No. x GTL x Measuring Range alongwith Liquid Name & Sp. Gr. and Optg. Temp & Pressure

Custom built spec./options available on demand.

CAGE PIPE NB (B)

EXTERNAL MOUNTING CAGE BODY SPIDER DRAIN PLUG

External mounting

Output 4-20mA 4-20mA with HART protocol 1-5 VDC RS 485 (modbus) Special Features None Intrinsically Safe Display type Not Provided Integral, Loop Powered Indicator (ref TLPI cat) Dual (Integral + Remote) Loop Power Indicator (ref TLPI cat) Remote Loop Powered Indicator (ref TLPI cat) Remote Indicator Controller (ref TLIC cat) Remote Universal Indicator Controller (ref TUIC cat) Remote Scanner (ref TSCN cat) Accessories Without External Cage Counter Flange with Nuts, Bolts & Gasket Still Well Others

Applications / Service : Storage Tanks for Oil, Fuel, Chemicals, Pure / Industrial Water, Critical Inventory, Pressurized Vessels, Interface Applications and Waste Water Treatment Plant, Tank Gauging System for Ships, Nitric Acid, 98% H2SO4, 33% HCL, Diesel, Water, Mineral / Lube Oil, Solvents
AREA REPRESENTATIVE / DISTRIBUTOR :

We reserve the right to modify design and specifications without prior notice.

CAT/00010/Rev-04/09-12

You might also like