100% found this document useful (2 votes)
793 views5 pages

SDCEM - Fiche Technique MR41E

The document describes an electric motor unit called the MR41E that is designed to automate disconnect switches and switches. It has features like reliability, electronic technology, communication capabilities, modularity, and energy saving. Associated services for the unit include a 3 year guarantee, hotline support, and annual maintenance contracts.

Uploaded by

chichid2008
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
793 views5 pages

SDCEM - Fiche Technique MR41E

The document describes an electric motor unit called the MR41E that is designed to automate disconnect switches and switches. It has features like reliability, electronic technology, communication capabilities, modularity, and energy saving. Associated services for the unit include a 3 year guarantee, hotline support, and annual maintenance contracts.

Uploaded by

chichid2008
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

REF. : 221-49A - Rev.

08

Motor operating device

TYPE MR41E
Patented system

ISO 9001 certification




Applications

The MR41E electric motor unit is designed to automate disconnect switches and
switches, inside or outside, using a single pole or multiple pole control system.
A very robustly designed electronic module manages the control unit for very

flexible operation.

Features
Reliability • Stainless steel casing
• Steel geared motor power module
• Irreversible kinematics
• Robust design to cope with adverse external conditions (humidity, heat, pollution etc.).

Electronic technology • Can be adjusted for any motor-driven power supply voltage (factory setting)
• Fewer electrical cables (reduction in installation costs)
• Reduced maintenance costs by preventative maintenance "when necessary"
• Speed varies over the travel of the disconnect switch to reduce mechanical loads
Communication • Operating information communicated for increased availability
• Expectation of the actual behaviour of the disconnect switches
• Overall view of the stock, locally or remotely, by putting into communication
networks using various media (2 or 4 wire twisted pairs, optic fiber) or protocols
(MODBUS, DNP3 etc.)

Modularity • Modifying the configuration to suit any type of installation: standardising the range

Energy saving • Optimised anti-condensation resistance and temperature regulation:


50% reduction in electrical consumption compared with a traditional control unit.

Associated services
3 year guarantee • For the disconnect switch and MR41E motor unit
Hotline available • By telephone: +33 (0)4 76 72 76 76
• By e-mail: [email protected]
Annual contract option • Your range maintained by our maintenance teams
After sales service • Renovation, refurbishing equipment, repairs and maintenance etc.
REF. : 221-49A - Rev. 08

Choice (tick
Base Option according to Specifications
your need)

Motorisation
M1 Power supply voltage 48 to 220 VDC / 110 to 400 VAC x
M2 Operating time 4s x
M3 Operating time 8s x
M4 Other operating time x Please specifiy
M5 Mechanical endurance 2000 cycles x
M6 Mechanical endurance 10000 cycles x
M7 Variable speed at the start and end of movement x
M8 Monitoring and operating torque limit x

Remote and Control Unit


C1 Power supply voltage 48 to 220 VDC / 110 à 230 VAC x
C2 Opening and closing control O/F simple polarity x
C3 Opening and closing control O/F double polarity x
C4 Other remote control drawing x Please specifiy
C5 Electrical interlocking of control orders x
C6 Mode selector : 4 positions x Local/In progress/Out of use/Manual
C7 Mode selector : 3 positions x In progress/Out of use/Manual
Mode selector in position Out of Use :
C8 On all the disconnector stroke x
C9 Only in opened position x
C10 Only in closed position x
C11 Only in opened or closed position x
C12 Dry contact indicator of mode selector positions x 2 dry contacts per position
C13 Local remote by push button x
C14 No push button on local remote x
C15 Padlocking of mode selector in position Out of Use x
C16 Padlocking of mode selector in position In progess x
C17 Other position to padlock x Please specifiy
C18 Electrical interlocking by coil forbidding use of emergency crank-handle x
C19 Same power supply voltage of the coil as power supply voltage x
C20 Other coil power supply voltage x Please specifiy
C21 Remote status indicators by Leds x
C22 Casing heating by heating conductor x For minimum ambiant temperature of -25°C
C23 Casing heating by thermostat resistance , low ambiant temperature x For minimum ambiant temperature of -35°C
C24 Standard SDCEM connection on spring casing terminals x
C25 Other type of connection x Please specifiy
C26 Labelling of terminals according to SDCEM standard x
C27 Labelling of terminals according to customer standard x Please specifiy
Indicator contact of the disconnector positions :
C28 8O and 8F* x
C29 from 7O and 7F and 1NO and 1NF, to 4O and 4F and 4NO and 4NF* x Please specifiy
C30 16O and 16F* x Please specifiy
C31 from 14O and 14F and 2 NO and 2 NF, to 8O and 8F and 8NO and 8NF* x Please specifiy

Communication
B1 Output on 1 electrical operating mechanism status indicator x Motor deficiency, TTLE,Maintenance,..please specify (3 max)
B2 Output on 2 electrical operating mechanism status indicators x Motor deficiency, TTLE,Maintenance,..please specify (3 max)
B3 Output on 3 electrical operating mechanism status indicators x Motor deficiency, TTLE,Maintenance,..please specify (3 max)

Casing
A1 Casing protection IP44 x
A2 Casing protection IP55 x
A3 Casing closed by padlocked latch x
A4 Casing closed by keylocked latch x
A5 Mechanical disconnector position indicator on output shaft x
A6 Mechanical disconnector position indicator inside the casing x
A7 Mechanical counter of number of operations x
A8 Casing lightning by bulb, during casing opening x
A9 Power supply of portable equipments, by socket 230 VAC and protection circuit breaker x
A10 Outdoor locking by contact keylock, of disconnector operating shaft x
A11 Position keylock (Ronis EL11AP), in position out of order x
A12 Copper earthing terminal and associated indoor commutator x
A13 Casing closed by 3 padlocks x
*O=Opened ; F=Closed ; NO=Normally opened ; NF = Normally closed
REF. : 221-49A
REF. : -221-49
Rev. 08

Electrical and mechanical features

Description Values Standards in force


MECHANICS Dimensions HxLxD 485 x 355 x 325 mm
Weight 26 kg
Protection index IP44/IP55 CEI 60 529

CLIMATE Operating temperature -25°C / + 50°C
Storage temperature -25°C / + 60°C
Humidity 95% HR / +50°C
High temperature reliability test 1500 hours at +85°C
High temperature under humidity reliability 1000 hours at 85°C/85%HR
EN 60068-2-2
test
Thermal cycle reliability test 500 cycles an hour -20°C/+80°C

CEM Electrostatic discharges 6 kV at contact / 8 kV in the air EN 61000-4-2


Electromagnetic field 80MHz-1GHz - 10V/m EN 61000-4-3
Electromagnetic field at digital telephone radio 900 MHz pulsed 200 Hz ENV 50204
frequences
Rapid transients in bursts 4 kV on power supply EN 61000-4-4
2 kV on remote control
Shock waves 4 kV in common mode EN 61000-4-5
2 kV in differential mode
Conducted RFs 150 kHz-80 MHz - 10 V rms EN 61000-4-6
Magnetic field 50 Hz 100 A/m EN 61000-4-8
Radiated emission 3 and 10 m - 30 MHz at 1 GHz EN 55011 Class A
Dielectric 1.2/50 µs : 5 kV CEI 60255-5
2 kV for 1 mn CEI 61180-1
Damped oscillating wave 100 kHz/1 MHz : 2.5 kV in common mode, 1 CEI 61000-4-12
kV in differential mode
GENERAL Design, manufacture and tests CEI 60271-102 and CEI 60694

All these values have been confirmed by tests in an independent laboratory. (test reports on request)

TORQUE/ CURRENT

25

20
MOTOR CURRENT (A)

Motor power
supply voltage
15

110 à 400 V
10
48 V

0
150 300 500 800 1000
DISCONNECT SWITCH TORQUE (N.m)
REF.REF.
: 221-49A
: 221-49
- Rev. 08

FIX 140 ±1
270
MR41E ELECTRIC MOTOR UNIT
Outline diagram
FIX 198 108

COMMANDE ELECTRIQUE TYPE MR41E

240 61 ±5 PLAQUE PRESSE ETOUPE


358 CABLE GLAND PLATE
525

91
324 ±10
COMMANDE ELECTRIQUE
MISE ATYPE
LA TERREMR41E
EARTHING CONNECTION

218
COMMANDE ELECTRIQUE TYPE MR41E
350 358 172 ±5 240 61 ±5 PLAQ
CAB
240 61 ±5 PLAQUE PRESSE ETOUPE
350 358 26
460 ±10 CABLE GLAND PLATE

65 ±5 354 ±10 4 ECROUS M12


525

91
4 NUTS M12
525

324 ±10
46 ±10 202 ±5
91

VIS : 20 < < 30


324 ±10

MISE
SCREW : 20 < < 30
MISE A LA TERRE
EARTH

218
172 ±5
EARTHING CONNECTION
218
172 ±5

460 ±10 26
65 ±5 460 ±10 354 ±10 4 ECROUS M12 26
4 NUTS M12
46 ±10 202 ±5 65 ±5 VIS : 20 < < 30 354 ±10 4 EC
SCREW : 20 < < 30 4 NU
46 ±10 202 ±5 VIS :

116
SCR

270
898 ±10

310 ±5

FIX 140 ±1
30

270

14 218 FIX 198 1


898 ±10

310 ±5
30

14 218 FIX 198 108


898 ±10

310 ±5
30

14 218
IE A GAUCHE AXE VERTICAL AXE DE SORTIE A DROITE
SHAFTAXE
LEFT
SORTIE A GAUCHE VERTICAL
AXESHAFT
VERTICAL OUTPUT
AXE DE SORTIESHAFT RIGHT
A DROITE
OUTPUT SHAFT LEFT VERTICAL SHAFT OUTPUT SHAFT RIGHT

Possible set ups


FolioA3-IGTE-ZU12.dwg

AXE SORTIE A GAUCHE AXE VERTICAL AXE DE SORTIE A DROITE


OUTPUT SHAFT LEFT VERTICAL SHAFT OUTPUT SHAFT RIGHT
FolioA3-IGTE-ZU12.dwg
REF. : 221-49A - Rev. 08

Electrical diagrams
Power supply

Remote control command

Information feedback

Anti-condensation resistance power supply

You might also like