0% found this document useful (0 votes)
2K views5 pages

Table 7.21.1 (Revised)

This document provides minimum requirements for plumbing fixtures in various occupancy groups based on the number of persons. It lists occupancy groups such as assembly (theaters, nightclubs, restaurants, museums), business (office buildings), mercantile (retail stores), and industrial uses. For each group, it specifies the minimum number of water closets, lavatories, showers, and other fixtures required as the number of persons increases.

Uploaded by

aries
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views5 pages

Table 7.21.1 (Revised)

This document provides minimum requirements for plumbing fixtures in various occupancy groups based on the number of persons. It lists occupancy groups such as assembly (theaters, nightclubs, restaurants, museums), business (office buildings), mercantile (retail stores), and industrial uses. For each group, it specifies the minimum number of water closets, lavatories, showers, and other fixtures required as the number of persons increases.

Uploaded by

aries
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Table 7.21.

1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 1

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Assembly A-1: Theaters and other facilities for the viewing of 100 or less 2 2 1 1 1 per 1
(A) the performing arts or motion pictures, 101 - 200 add 1 add 1 add 1 add 1 500 service
typically with fixed seats. 201 - 300 add 1 add 2 add 0 add 1 people sink
ea. add'l 300 add 1 add 2 add 1 add 1 per floor
See Notes: (6), (9) over 300 (21)

A-2: Night clubs, bars, taverns, and similar 25 or less 1 1 1 1 1 per 1


facilities where drink and/or food is consumed. 26 - 50 add 1 add 1 add 1 add 1 250 service
51 - 100 add 1 add 1 add 1 add 1 people sink
See Notes: (2), (3), (6), (9), (13) ea. add'l 200 add 1 add 1 add 1 add 1 (2) per floor
over 100 (21)

A-2: Restaurants, banquet halls, food courts, 50 or less 1 1 1 1 1 per 1


carry-outs with seating. 51 - 100 add 1 add 1 add 1 add 1 250 service
101 - 200 add 1 add 1 add 0 add 0 people sink
See Notes: (2), (3), (6), (9), (13) 201 - 300 add 1 add 1 add 1 add 1 (2) per floor
ea. add'l 200 add 1 add 1 add 1 add 1 (21)
over 300

A-3: Museums, art galleries, exhibition halls, 50 or less 1 1 1 1 1 per 1


lecture halls, libraries. 51 - 150 add 1 add 1 add 1 add 1 500 service
151 - 300 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (9) ea. add'l 300 add 1 add 1 add 1 add 1 per floor
over 300 (21)

A-3: Passenger terminals, transportation facilities. 100 or less 1 1 1 1 1 per 1


101 to 250 add 2 add 2 add 1 add 1 500 service sink
See Notes: (6), (9) ea. add'l 250 add 2 add 2 add 1 add 1 people per floor
over 250 (21)

A-3: Places of worship and other religious services. 25 or less 1 1 1 1 1 per 1


26 - 150 add 1 add 1 add 1 add 1 500 service sink
See Notes: (6), (9) ea. add'l 150 add 1 add 1 add 1 add 1 people per floor
over 150 (21)

A-3: Gymnasiums (without spectator seating), 50 or less 1 1 1 1 1 per 1


health spas. 51 - 100 add 1 add 1 add 1 add 1 200 service
101 - 200 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (9), (20) ea. add'l 200 add 2 add 2 add 2 add 2 per floor
over 200 (21)
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 2

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Assembly A-4: Coliseums, arenas, skating rinks, pools and 1 - 100 2 2 2 2 1 per 1
(A) tennis courts for indoor sporting events and 101 - 200 add 2 add 2 add 2 add 2 500 service
(continued) activities. 201 - 400 add 2 add 2 add 2 add 2 people sink
ea. add'l 400 add 2 add 4 add 1 add 2 per floor
See Notes: (6), (9), (20) up to 2600 (21)
ea. add'l 600 add 2 add 4 add 1 add 2
over 2600

A-5: Stadiums, amusement parks, bleachers and 1 - 100 2 2 2 2 1 per 1


grandstands for outdoor sporting events and 101 - 200 add 2 add 2 add 2 add 2 1000 service
activities. 201 - 400 add 2 add 2 add 2 add 2 people sink
ea. add'l 400 add 2 add 4 add 1 add 2 per floor
See Notes: (6), (9), (20) up to 2600 (21)
ea. add'l 600 add 2 add 4 add 1 add 2
over 2600

Business B: Buildings for the transaction of business, 1 - 15 1 1 1 1 1 per 1


(B) professional services, office buildings, banks, 16 - 50 add 1 add 1 add 0 add 0 100 service
and similar uses. ea. add'l 50 add 1 add 1 add 1 add 1 people sink
over 50 per floor
See Notes: (6), (9), (12), (15) (21)

Education E-1: Day Care, Preschool, Kindergarten 15 or less 1 1 1 1 1 per 1


(E) 16 - 30 add 1 add 1 add 1 add 1 100 service
See Notes: (6), (9) 31 - 50 add 1 add 1 add 1 add 1 people sink
51 - 75 add 1 add 1 add 1 add 1 per floor
76 - 100 add 1 add 1 add 1 add 1 (21)
ea. add'l 50 add 1 add 1 add 1 add 1
over 100

E-2: Elementary Grades 1 - 6 25 or less 1 1 1 1 1 per 1


26 - 50 add 1 add 1 add 1 add 1 100 service
See Notes: (6), (9) 51 - 75 add 1 add 1 add 1 add 1 people sink
76 - 100 add 1 add 1 add 1 add 1 per floor
ea. add'l 50 add 1 add 1 add 1 add 1 (21)
over 100

E-3: Secondary Grades 7 - 12 30 or less 1 1 1 1 1 per 1


and higher education facilities 31 - 60 add 1 add 1 add 1 add 1 100 service
61 - 100 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (9), (17) ea. add'l 50 add 1 add 1 add 1 add 1 per floor
over 100 (21)
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 3

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Factory F-1 and F-2: Structures in which occupants are 25 or less 1 1 1 1 1 1 per 1
(F) engaged in work fabricating, assembling, or 26 - 50 add 1 add 1 add 1 add 1 emergency 250 service
processing products, materials, food, etc.. 51 - 100 add 1 add 1 add 1 add 1 shower per people sink
ea. add'l 100 add 1 add 1 add 1 add 1 10 people per floor
See Notes: (6), (9) over 100 exposed (21)
to skin
contamin-
ation.

Institutional I-1: Residential care, assisted living facilities (24-hour). 1 - 10 1 1 1 1 1 per 1 per 1
(I) ea. add'l 10 add 1 add 1 add 1 add 1 8 100 service sink
See Notes: (6), (9), (11) over 10 occupants occupants per floor
(21)

I-2: Patients in hospitals, nursing homes, etc. 1 water closet 1 lavatory 1 per
per per patient
patient room patient room room

I-2: Employees in hospitals, etc. 25 or less 1 1 1 1 1 per 1


26 - 50 1 1 0 0 100 service
See Notes: (6), (9) 51 - 100 add 1 add 1 add 1 add 1 people sink
ea. add'l 100 add 1 add 1 add 1 add 1 per floor
over 100 per wing

I-2: Visitors in hospitals, etc. 50 or less 1 1 1 1 1 per


51 - 100 add 1 add 1 add 1 add 1 500
See Notes: (6), (9) ea. add'l 100 add 1 add 1 add 1 add 1 people
over 100

I-3: Prisoners in prisons. 1 per 1 per 1 per 1 per


cell cell 15 100
prisoners prisoners

I-3: Detainees in reformatories, detention centers, and 15 or less 1 1 1 1 1 per 1 per


correctional centers. 16 - 30 add 1 add 1 add 1 add 1 15 100
31 - 50 add 1 add 1 add 1 add 1 detainees detainees
51 - 75 add 1 add 1 add 1 add 1
76 - 100 add 1 add 1 add 1 add 1
ea. add'l 50 add 1 add 1 add 1 add 1
over 100
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 4

Classification Occupany Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Institutional I-3: Employees in prisons, reformatories, etc. 25 or less 1 1 1 1 1 per 1
(I) 26 - 50 add 1 add 1 add 0 add 0 100 service sink
(continued) See Notes: (9) 51 - 100 add 1 add 1 add 1 add 1 people per floor
ea. add'l 50 add 1 add 1 add 1 add 1 per wing
over 100

I-3: Visitors in prisons, reformatories, etc. 50 or less 1 1 1 1 1 per


51 - 100 add 1 add 1 add 1 add 1 500
See Notes: (9) ea. add'l 100 add 1 add 1 add 1 add 1 people
over 100

I-4: Adult day care, child day care. 15 or less 1 1 1 1 1 per 1


16 - 30 add 1 add 1 add 1 add 1 100 service
See Notes: (9) 31 - 50 add 1 add 1 add 1 add 1 people sink
51 - 75 add 1 add 1 add 1 add 1 per floor
76 - 100 add 1 add 1 add 1 add 1 (21)
ea. add'l 50 add 1 add 1 add 1 add 1
over 100

Mercantile M: Stores, shops, markets, shopping centers, 50 or less 1 1 1 1 1 per 1


(M) sales rooms, service stations, etc. 51 - 150 add 1 add 1 add 0 add 0 500 service
151 - 400 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (7), (8), (9), (15) ea. add'l 400 add 1 add 1 add 1 add 1 per floor
over 400 (21)

Residential R-1: Hotels, motels, boarding houses (transient). 1 water closet 1 lavatory 1 1
(R) per per per service sink
guest room guest room guest room per floor
(21)

R-2: Dormatories, fraternities, sororities, 10 or less 2 2 2 2 1 per 1 per 1


boarding houses, (not transient). 11 - 20 add 1 add 1 add 1 add 1 8 people 100 service sink
ea. add'l 20 add 2 add 2 add 2 add 2 people per floor
over 20 (21)

R-2: Apartment houses, condominiums. 1 water closet 1 lavatory 1 1 kitchen


per unit per unit per unit sink per unit
See Notes: (10)
provisions for
1 clothes
washer per
20 units
Table 7.21.1 see (1)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES - Page 5

Classification Occupancy Group No. of Persons Water Closets Lavatories Bath Drinking Other
see (14) of each Sex for urinals - see (5) or Water
see (4), (16) Male Female Male Female Shower Facilities
Residential R-2: One-and two-family dwellings. 1 water closet 1 lavatory 1 1 kitchen
(R) per unit per unit per unit sink per unit
(continued)
provisions for
1 clothes
washer
per unit

R-3: Congregate living facilities with 16 or fewer 10 or less 1 1 1 1 1 1 per 1


persons. ea. add'l 10 add 1 add 1 add 1 add 1 per 8 100 service sink
over 10 persons people per floor
See Notes: (9) (21)

R-4: Residential care, assisted living facilities. 10 or less 1 1 1 1 1 1 1


ea. add'l 10 add 1 add 1 add 1 add 1 per 8 per service sink
See Notes: (9) over 10 residents 100 per floor
people (21)

Storage S-1 & S-2: Structures for the storage of goods, 50 or less 1 1 1 1 1 per 1
(S) warehouses, storehouses, and freight depots. 51 - 100 1 1 0 0 500 service
ea. add'l 100 add 1 add 1 add 1 add 1 people sink
See Notes: (6), (18), (19) over 100 per floor
(21)