TS Fault sync in Ericsson - Wire Free Alliance
Dear Friends,
What is the reason of alarm "TS Fault sync" in ericsson systems .How we can rectify
it. in my case it happened for some site after EDGE TS increasing (NUMREQBPC)
Let me know how we can rectify it
Thanks ,
5 Lastest Threads by electron
Thread Forum Last Poster Replies Views Last Post
2010-11-
Ericsson RNC Dump Ericsson Darko 2 50 27 11:09
PM
2010-11-
2G/3G Actix celref ACTIX sonerss 1 43 26 08:18
AM
SDCCH Usage distribution 2010-11-
Ericsson electron 0 30 25 03:45
counter PM
2010-11-
ACLC Parameter Ericsson electron 0 29 22 04:49
PM
2010-11-
FBCHALLOC Ericsson electron 2 38 22 04:44
PM
2010-08-19, 02:26 PM #2
Join Date: 2007-09-19
kvf Posts: 343
Senior Member Rep Power: 5
Reputation:188
Credit: 619
http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (1 of 5)29.11.2010 11:59:55
TS Fault sync in Ericsson - Wire Free Alliance
Default Re: TS Fault sync in Ericsson
TS SYNC FAULT - Synchronization lost on uplink / downlink TRAU or PCU channels
Feature: Traffic decreasing, Drop and Block call increasing
Influence on: SDCCH performance, TCH performance, EDGE\GPRS performance.
The sources of TS SYNC FAULT are different and must be checked specifically for each
site: Inconsistency connected and defined RBS ports;Incorrect RBS mode (CASCADED
or STAND ALONE); Transmission or RBS disconnection during works or failure; Bad
transmission quality; Poor RBS E1 cables or connectors, etc
in common case use commands rxbli/rxble - This commands orders the manual
blocking/unblocking of one or more MO instances (TS for us)
(for example RXBLI:MO=RXOTS-215-2-0&&7;!block, RXBLE - unblocking! )
Quote:
Originally Posted by electron
Dear Friends,
What is the reason of alarm "TS Fault sync" in ericsson systems .How we can
rectify it. in my case it happened for some site after EDGE TS increasing
(NUMREQBPC)
Let me know how we can rectify it
Thanks ,
Last edited by kvf; 2010-08-19 at 06:26 PM
The Following User Says Thank You to kvf For This Useful Post:
electron
2010-08-19, 06:18 PM #3
http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (2 of 5)29.11.2010 11:59:55
TS Fault sync in Ericsson - Wire Free Alliance
Join Date: 2009-05-02
Posts: 281
electron Rep Power: 2
Senior Member Reputation:135
Credit: 3987
Default Re: TS Fault sync in Ericsson
Thanks for replay,
But it happened after increasing NUMREQEGPRS for some cells suddenly.Is there any
correlation?
Thanks
2010-08-19, 09:59 PM #4
andr2008 Join Date: 2009-01-09
Posts: 14
Rep Power: 2
Junior Member Reputation:10
Credit: 44
Default Re: TS Fault sync in Ericsson
Hello!
It can be from the confactor is big, it means that not enough space for signalling
channels in the E1. I recommend to increase quantity E1 and reduce confactor.
BR
2010-08-20, 04:38 AM #5
http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (3 of 5)29.11.2010 11:59:55
TS Fault sync in Ericsson - Wire Free Alliance
redernesto Join Date: 2009-03-21
Posts: 44
Rep Power: 2
Member Reputation:50
Credit: 123
Default Re: TS Fault sync in Ericsson
Hi
This problem show, when 1 TS is no consecutive count, one TS in the , recomendation
erase configuration for RXAPE and do you create new TS structure with RXAPI.
2010-08-20, 06:28 AM #6
radenmohawk Join Date: 2009-03-24
Posts: 153
Rep Power: 2
Member Reputation:36
Credit: 668
Default Re: TS Fault sync in Ericsson
Quote:
Originally Posted by redernesto
Hi
This problem show, when 1 TS is no consecutive count, one TS in the ,
recomendation erase configuration for RXAPE and do you create new TS
structure with RXAPI.
which time slot have to erase? how to find the problem time slot?
2010-08-20, 06:58 AM #7
http://www.finetopix.com/ericsson/11815-ts-fault-sync-ericsson.html (4 of 5)29.11.2010 11:59:55
TS Fault sync in Ericsson - Wire Free Alliance
roloramos Join Date: 2010-05-13
Posts: 75
Rep Power: 1
Member Reputation:36
Credit: 893
Default Re: TS Fault sync in Ericsson
rxbli:mo=rxots-xx-yy;
rxese:mo=rxots-xx-yy;
rxesi:mo=rxots-xx-yy;
rxlti:mo=rxots-xx-yy;
rxble:mo=rxots-xx-yy;
The Following 2 Users Say Thank You to roloramos For This Useful Post:
electron, kamnikot
2010-09-05, 01:03 AM #8
Join Date: 2010-05-16
zee86 Posts: 194
Member Rep Power: 1
Reputation:23
Credit: 292
Default Re: TS Fault sync in Ericsson
rxbli:mo=rxots-xx-yy-zz;
rxlti:mo=rxots-xx-yy-zz;
rxble:mo=rxots-xx-yy-zz;
also check what is fault code
rxasp:mo=rxots-xx-yy-zz;
rxmfp:mo=rxots-xx-yy-zz;
fault code list is attached without pass