Vuototecnica
Vuototecnica
SOLUTIONS
catalogue
INDEX
3 HISTORY OF THE CONCEPT OF A VACUUM
8 INTRODUCTION TO VACUUMS - BASIC PRINCIPLES
9 MEASURING PRESSURE
10 LEVELS OF VACUUM
11 MAIN CHARACTERISTICS OF VACUUMS
12 OPERATING PRINCIPLE OF VACUUM CUPS
13 BOILING TEMPERATURE OF WATER AT VARYING ABSOLUTE PRESSURES
15 PUMP AND VACUUM GENERATOR FLOW RATE AND RELATIVE UNIT OF
MEASUREMENT
MEASURING FLOW RATE
16 FLOW LOSS
ENERGY REQUIREMENTS BASED ON VACUUM PRODUCED
17 THE MAIN VACUUM GENERATORS
20 VACUUM UNIT OF MEASUREMENT CONVERSION TABLE
ABSOLUTE PRESSURE UNIT OF MEASUREMENT CONVERSION FACTORS
21 SOME EXAMPLES OF INDUSTRIAL VACUUM APPLICATION, TODAY
23 EVALUATION OF LIFTING FORCES - CALCULATION EXAMPLES
26 TECHNICAL DATA RELATED TO THE VACUUM CUPS IN THE CATALOGUE
FACTOR OF SAFETY
CHOOSING THE DIAMETER AND NUMBER OF VACUUM CUPS TO BE USED WITH A
LEVEL OF VACUUM HIGHER THAN -75KPA
27 CHOOSING THE DIAMETER OF THE VACUUM CUPS TO BE USED AT DIFFERENT
LEVELS OF VACUUM
28 LIFTING WITH VACUUM CUPS OVER SEA LEVEL
29 SPECIAL CASES OF LIFTING
ENERGY REQUIREMENTS AT DIFFERENT LEVELS OF VACUUM
CHOOSING THE VACUUM CUP SHAPE
30 CHOOSING THE VACUUM CUP COMPOUND
31 GENERAL CHARACTERISTICS OF RUBBER COMPOUNDS
34 TO ORDER VACUUM CUPS
VACUUM CUPS IN STOCK
CHOOSING VACUUM CUP HOLDERS
CHOOSING A PUMP OR VACUUM GENERATOR
36 CHOOSING CHECK VALVES, FILTERS, HOSES, SOLENOID VALVES AND
DISTRIBUTORS
VACUUM CUPS BASED ON BERNOULLI’S THEOREM
37 TECHNICAL MEMO
IP: DEGREE OF PROTECTION OF ENCLOSURES
INTRODUCTION TO VACUUMS
• BASIC PRINCIPLES OF PHYSICS
- What is a vacuum?
The term “vacuum” refers to the physical situation that occurs in an environment where the gas pressure is lower than the
atmospheric pressure.
Positive pressures are defined as all those with values higher than atmospheric pressure; negative is defined as all those with lower
values. To simplify, let's look at the diagram below:
Since pressure dimensionally represents a force per unit area, its unit of measure is the pascal (symbol Pa), which represents the
pressure that occurs when the force of a newton (symbol N) is exerted on the surface unit, measured square metres (symbol m²).
Therefore:
pascal = newton/metre2 ==> Pa = N/m2
The unit of measurement of pressure, adopted by the International System SI, is the pascal (symbol Pa).
In practice, through, alternative units of measurement are also used such as millibars (mbar), equal to 100 Pa, and Torr or mmHg,
which is equal to 133.322 Pa. The latter is a unit that is not consistent with the International System SI, but is tolerated for
measuring blood pressure.
8
Atmospheric pressure, measured in mbar, decreases as the altitude measured in m changes, as better specified in the diagram
below.
100000
Altitude above sea level (m)
10000
1000
100
0 200 400 600 800 1000 1200
MEASURING PRESSURE
The instruments commonly used for measuring positive pressure are called pressure gauges, while those intended for measuring
negative pressure are called vacuum gauges or vacuum metres.
Comparison of pressure values measured at sea level with the same values measured at different altitudes
mmHg mbar Altitude m -60 KPa -75 KPa -85 KPa -90 KPa -99 KPa
760 1013.25 0 60.0 75.0 85.0 90.0 99.0
750 999.9 111 58.7 73.7 83.7 88.7 97.7
740 986.6 200 57.3 72.3 82.3 87.3 96.3
730 973.3 275 56.0 71.0 81.0 86.0 95.0
720 959.9 467 54.7 69.7 79.7 84.7 93.7
710 946.6 545 53.3 68.3 78.3 83.3 92.3
700 933.3 655 52.0 67.0 77.0 82.0 91.0
690 919.9 778 50.7 65.7 75.7 80.7 89.7
671 894.6 1000 48.1 63.1 73.1 78.1 87.1
593 790.6 2000 37.7 52.7 62.7 67.7 76.7
9
LEVELS OF VACUUM
Depending on the pressure, slightly or much lower than the atmospheric pressure (that is 101325 Pa), the phenomena that occur
can be very different, as the means to obtain and measure that pressure can be very different.
Usually different levels of vacuum are distinguished and given a specific name in relation to the various sub-atmospheric
pressure ranges, as indicated in the following table:
The highest level of vacuum reached on earth differs considerably from the absolute vacuum value, which remains a purely
theoretical value.
There is a minimal presence of atoms even in space and therefore in the absence of atmosphere.
In industry, much more simply, vacuums are divided into three application areas, which depend on the level of vacuum required.
- Rough vacuum: Usually used in all those applications where a high intake
air flow and a level of vacuum lower than - 20 Kpa is required
- Industrial vacuum: “Industrial vacuums” are intended as a level of vacuum between - 20 and - 99.9 KPa.
This range covers most applications.
McLeod Digital
Mercury vacuum gauge Pirani vacuum metre
10
MAIN CHARACTERISTICS OF VACUUMS
If we take, for example, a bell jar and insert a lit candle, a bell and a glass of water inside it, we will notice that, as we create the
vacuum, the candle will slowly go out, the sound of the bell will fade until it disappears and the water, contained in the glass, will
begin to freeze when the degree of vacuum falls below 6.1 mbar absolute.
At the same time, the atmospheric pressure, acting on the whole surface of the bell jar and also on the underside of the support
surface, will compress it on the latter with a force that is directly proportional to the level of vacuum reached inside it.
The candle blowing out shows that no life is possible in the absence of air.
This characteristics is used in the food industry for food packaging: vacuums in fact preserve food from spores, bacteria and moulds.
The bell phenomenon shows that sound waves are not transmitted in a vacuum and therefore this characteristic can be
exploited in industry to improve sound insulation.
The water contained in the glass tends to cool down because its boiling temperature varies with the surrounding pressure, until it
freezes to below 6 mbar absolute.
Also this characteristic of vacuums, for example, has been used in the field of fruit and vegetable refrigeration. Finally, the
force exerted by the atmospheric pressure on the vacuum chamber is the same force that is used by vacuum cups for vacuum
handling.
11
OPERATING PRINCIPLE OF VACUUM CUPS
When a vacuum forms inside a vacuum cup, the atmospheric pressure that surrounds it exerts a force on it that makes it adhere
to the surface on which it rests.
This force, which is exercised in a uniform and opposite way between the vacuum cup and the external surface of the object on
which it rests, is higher the greater the level of vacuum reached within it.
P1=1013.25 mbar
∆P = Patm - P1
Where:
∆P = Pressure differential expressed in mbar
Patm = Atmospheric pressure = 1013 mbar at sea level
P1 = Absolute pressure reached inside the vacuum cup expressed in mbar
From the table inserted in the technical memo, relating to the pressure unit of measurement conversion factors, we note that it is
necessary to develop the following formula to transform the mbar into Kg/cm2,:
If we want to calculate, for example, the force exerted by the atmospheric pressure on a vacuum cup inside which a level of vacuum
was created of 250 mbar abs (-75 KPa), we would proceed as follows:
From the formulas above, it is easy to deduce that, for the same ∆P, the greater the gripping surface of the vacuum cup, the greater
the force exerted on it by atmospheric pressure.
To detach the vacuum cup from the gripping surface, you will need to exert a force on it that is equal and opposite to that exerted
by atmospheric pressure: in the vacuum handling or gripping sector, a part of this force is used, obtainable by dividing the whole
contrary force for a factor of safety that can vary from 2 to 4, depending on the conditions of the load to be gripped.
12
BOILING TEMPERATURE OF WATER AT VARYING
ABSOLUTE PRESSURES
The boiling temperature of the water varies with the surrounding pressure and therefore, also depending on the altitude.
The diagram below shows the relationship between absolute pressure in mbar and temperature in °C.
100
80
60
Temperature (°C)
40
20
0
-20
-40
-60
0.001 0.01 0.1 1 10 100 1000 10000
mbar
Working principle
For rapid and uniform cooling, the treated products must have a high surface/volume ratio (kale, cabbage, lettuce, etc.).
Cooling is based on the relationship between water temperature and vapour pressure.
When the level of vacuum is increased, the water evaporates at an increasingly lower temperature, removing heat from the product.
13
Vacuum and temperature values detected during the process
mbar °C
15 VACUUM
13
PRODUCT TEMPERATURE
10
12
9
7
10 END OF VACUUM
6
AUTOCLAVE DOOR OPENING
5
4
6.56 FINAL TEMPERATURE OF THE
3
PRODUCT BROUGHT
2 INTO THE COLD ROOM
1
Time in
minutes 0 5 10 15 20 25 30 35 40
The quantity of water evaporated represents about 1% for every 5-6 °C that the temperature is lowered.
The vacuum is obtained with a high vacuum pump and the vapour developed is condensed on a refrigerating coil. The level of
vacuum and the temperature must be detected by programmable precision instruments with direct reading to obtain the ideal
cooling cycle based on the product.
The temperature value must be detected by an auxiliary safety device, which will have the function of protecting the product from
the risk of frost.
These are just some of the features of vacuums commonly used in industry.
14
PUMP AND VACUUM GENERATOR FLOW RATE AND RELATIVE UNIT OF
MEASUREMENT
The volumetric quantity of fluid sucked in by the pump or vacuum generator, in the unit of time, is called the flow rate.
Definition: Q, q, = V/t (volume/time)
In the International System SI, the flow rate is measured in m3/s.
Current multiples of use are: l/min, l/s, m3/h.
The instruments commonly used for measuring the flow rate are called flowmeters.
Based on the same operating principle, asameters are very precise laboratory
instruments, which take their name from the company that produces them: the ASA
company.
Flowmeters and asameters are variable area meters for fluids based on the Bernoulli
principle.
Asameters consist of a glass tube and a body called a float.
The tube is tapered inside and calibrated with very tight tolerances. Inside the tube is
a suitably shaped float with a diameter slightly smaller than the minimum diameter
of the tube.
If we run a fluid with ascending motion through the system, the float moves into the
tube and stops at a certain height corresponding to a well-defined flow.
A scale engraved on the glass tube lets you read this flow rate at the point where the
float stops.
Flow
Tube
Glass
Float
Asameter operating
Flow diagram
15
Flow loss
The diagram shows the flow loss value through a 1 mm2 cross-section hole at different levels of vacuum, measured in Nl/s (Normal
litres per second, the unit of measurement of the flow rate referring to the normal atmospheric pressure level of the sea).
0.2
0.18
0.16
0.14
Flow rate (Nl/s)
0.12
0.1
0.08
0.06
0.04
0.02
0
0 20 40 60 80 100
Vacuum (-KPa )
To obtain the total loss, simply multiply the flow rate value indicated in the diagram, in correspondence with the available level of
vacuum, for the total loss section.
The diagram shows the increase in energy requirements as the level of vacuum increases.
As can be seen, the energy demand drastically increases above -90 Kpa; for this reason, it is advisable to stay below this value.
(Law by Robert Boyle 1627-1691)
100
90
80
70
Vacuum (-KPa)
60
50
40
30
20
10
0
0 10 100 1000 10000 100000 1000000
Energy requirements
16
THE MAIN VACUUM GENERATORS
In industry, much more simply, vacuums are divided into three application areas, which depend on the level of vacuum required.
- Rough vacuum: Used in all those applications where a high intake air flow and a level of vacuum lower than - 20 KPa is
required.
In this application area, impeller-type electromechanical pumps are usually used, such as centrifugal fans
and side channel blowers, pneumatic and similar flow generators.
Screen printing on fabrics, for example, is one of the typical applications that require a low level of vacuum.
Suction
or compression fitting
Electric motor
Impeller
fins
U
R
17
- Industrial vacuum: “Industrial vacuums” are intended as a level of vacuum between --20 KPa and -99.9 KPa. This range covers
most applications.
Industrial vacuums are mainly produced by rotary vane, liquid ring, piston, lobe, etc. vacuum pumps, all driven
by electric or petrol or hydraulic motors, and vacuum generators based on the Venturi principle, powered
by compressed air. Industrial vacuums are used from handling with vacuum cups to thermoforming, from
vacuum clamping to vacuum packaging, etc.
DELIVERY IMPELLER
IMPELLER
BODY
BODY
AXIS
AND LIQUID RNG. SUCT.
PLANE
P R
18
- Process vacuum: Vacuums exceeding -99.9 KPa.
The main generators of this level of vacuum are two-stage rotary vane pumps, eccentric rotor pumps,
Roots pumping units, turbomolecular pumps, diffusion pumps, cryogenic pumps, etc.
The most common applications are freeze-drying, metallisation and vacuum heat treatments. Those of a
scientific nature, however, include spatial simulations.
Roots pump
VACUUM
Diffusion pump
19
VACUUM UNIT OF MEASUREMENT CONVERSION TABLE
mbar torr. inch. Hg mmHg bar -KPa mbar
abs. abs. vacuum vacuum vacuum vacuum abs.
1000
1013,25
760
0
0
0
0
1000
1013,25
5
500 10
500 15 0,5 50 500
20 500
100
25
26
100 27 0,9 90 100
700
50 28
50 0,95 95 50
29
10 29,5
750
10 29,7 0,99 99 10
5 755
5 0,995 99,5 5
29,9
29,99
0,1 759,86
0,133 0,133
0,1 0,075 759,9 0,9999 99,99 0,1
29,997
0,05
0,05 0,99995 99,995 0,05
29,999
mbar x 1 10-3 0,75 2,95x 10-2 14,5 x 10-3 9,87 x 10-4 1,02 x 10-3 10,2 1,02 x 10-2 100,0
bar x 1000,0 1 750,0 29,53 14,6 0,987 1,02 10197,0 10,19 100000
torr x 1,33 1,33 x 10-3 1 3,94 x 10-2 1,93 x 10-2 1,316 x 10-3 1,359 x 10-3 13,59 1,359 x 10-3 133,32
inch. Hg x 33,9 33,9 x 10-3 25,4 1 0,491 3,34 x 10-2 3,45 x 10-2 345,0 0,345 3386,0
psi (lbf/in ) 2
x 68,9 6,89 x 10 -2
51,7 2,04 1 6,8 x 10 -2
7,03 x 10 -2
703 0,703 6897
atm x 1013,25 1,013 760,0 30,0 14,696 1 1,033 10332 10,332 101325,0
Kg/cm2 (at) x 981 0,981 735,6 28,96 14,2 0,968 1 10000 10 98067,0
mm H2O x 9,81 x 10-2 9,81 x 10-5 7,35 x 10-2 2,89 x 10-3 1,42 x 10-3 9,67 x 10-5 10-4 1 10-3 9,8067
m H2O x 98,067 9,81 x 10 -2
73,5 2,89 1,42 9,67 x 10 -2
10 10000 1 9806,7
Pa (N/m2) x 0,01 10-5 7,5 x 10-3 2,95 x 10-4 1,45 x 10-4 9,87 x 10-6 1,02 x 10-5 0,102 1,02 x 10-4 1
20
SOME EXAMPLES OF INDUSTRIAL VACUUM APPLICATION, TODAY
Vacuum cup handling of sheet metal, glass, marble, OCTOPUS vacuum gripping systems Transfer of powders, granulates, liquids, etc.
wood, etc.
Filling at constant volume Egg handling with vacuum cups Labelling - vacuum cup gripping
Bag opening with vacuum cups in the Packaging sector Vacuum impregnation Vacuum clamping for machining centres
21
SEALING PUMP
FOR
RESIN SUCTIONED VACUUM
FROM VACUUM
RESIN VACUUM BAG
MOULD
PUMP PUMP
FOR FOR
VACUUM VACUUM
SUCTION
VALVE
Typographic sector
The vacuum-aided handling and clamping sector is undoubtedly the one most gratifying to us and the one in which we have
developed our greatest expertise, in our over forty years of activity.
The description of vacuum cups, indispensable tools for vacuum handling, design notes, recommendations for choosing the best
pumps and accessories and the technical memo will aid even the least experienced sector designers in safely sizing handling
vacuum equipment.
22
EVALUATION OF LIFTING FORCES - CALCULATION EXAMPLES
For a correct dimensioning of a vacuum cup handler, it is firstly important to know and assess the features of the load to be
handled.
- Nature
- Dimensions and shape
- Mass
- Roughness and unevenness of the gripping surface
- Permeability
If we take, for example, a steel sheet with the following dimensions:
- Length 4.0 m
- Width 1.8 m
- Thickness 3.0 mm
Where:
m = Mass (kg)
A = Length (m)
B = Width (m)
C = Thickness (m)
Ps = Specific weight (for steel = 7860 Kg/m3)
Once the mass has been determined, the force of the vacuum cups required for move it is calculated by evaluating its direction and
the position of the vacuum cups with respect to the load, without disregarding the acceleration or deceleration forces acting on
the moving load and the friction that develops between the vacuum cups and the gripping surface.
The most common cases are:
F = m x (g + a) x η
23
Where:
F = Force of the vacuum cups (N)
m = Mass (Kg)
g = Force of terrestrial gravity (9.81 m/s2)
a = Acceleration or deceleration (5 m/s2, for this case)
η = Factor of safety (minimum 2 for our example; for materials with rough, irregular and
permeable surfaces, the value to be considered can vary from 2.5 to 3)
F = m x (g + a/μ) x η
Where:
F = Force of the vacuum cups (N)
m = Mass (Kg)
g = Force of terrestrial gravity (9.81 m/s2)
a = Acceleration or deceleration (5 m/s2, in this case)
μ = Coefficient of friction = 0.1 for oiled surfaces
= 0.2 - 0.3 for wet surfaces
= 0.5 for wood, glass, metal and marble
= 0.6 for rough surfaces
η = Factor of safety (minimum 2 for our example)
Note: The coefficients of friction indicated are purely indicative. During the design phase, the values relating to the materials of the
loads to be handled must be checked carefully.
24
3rd case - Vertical vacuum cups, vertical force.
F = (m/μ) x (g + a) x η
Where:
F = Force of the vacuum cups (N)
m = Mass (Kg)
μ = Coefficient of friction (0.5 in this case)
g = Force of terrestrial gravity (9.81 m/s2)
a = Acceleration or deceleration (5 m/s2, in this case)
η = Factor of safety (2 for our example)
As you can see, the third example is always the one that requires the greatest force and, therefore, the utmost attention is
recommended during the design phase for all the factors required.
25
TECHNICAL DATA RELATED TO THE VACUUM CUPS
IN THE CATALOGUE
For practical reasons and to simplify the choice of vacuum cups, all the lifting force values, shown in the table, are expressed in Kg
and calculated based on the following formula:
SxP
F=
η
Where:
F = Lifting force expressed in Kg
S = Vacuum cup gripping surface, expressed in cm2
P = Force exerted by atmospheric pressure, depending on the level of vacuum, expressed in Kg/cm2
η = Factor of safety
FACTOR OF SAFETY
Our vacuum cups have been designed to theoretically suspend a load equal to three times the force value indicated in the tables.
If we consider, for example, a vacuum cup ø 60 mm (item 08 60 10) whose gripping surface S is 28.26 cm2, we will obtain the
following by developing the formula shown above:
28.26 x 0.75
F= = Kg 7.06
3
which is the value shown in the table, next to the item of the vacuum cup used as an example.
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Example: Suppose we have to lift an oil drum weighing 140 kg with a single vacuum cup and with a level of vacuum available greater than
-75 KPa. From the tables relating to the vacuum cups, we find that those with Ø 300 mm (item 08 300 10) are suitable for solving our problem,
since their lifting force is 176.6 kg and therefore higher than the required weight of 140 kg.
26
If, on the other hand, the load to be lifted is a steel plate, the weight of which is also 140 kg, it will no longer be possible to use a
single vacuum cup, since the sheet would flex, but we will need to use at least 4 vacuum cups or, better yet 6, if we want to keep
the sheet perfectly taut.
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
If you want to use 4 vacuum cups, you will have to choose with a Ø 150 mm (item 08 150 10, 08 150 36, 08 150 74,08 150 15, etc.),
each having a lifting force of 45 kg, so together they are able to lift a maximum load of 180 kg.
If you instead want to use 6 vacuum cups, their diameter can be reduced to 110 mm (item 08 110 10, 08 110 24, 08 110 58, 08 110
15, etc.), with a lifting force of 23.7 kg each, so together they are able to lift a maximum load of 142.2 kg.
mxη
D = 113 x
Pxn
Where:
D = Diameter of the vacuum cup, expressed in mm
m = Mass of the load to be lifted, expressed in Kg
P = Level of vacuum, expressed in -KPa
η = Factor of safety, never less than 2
n = Number of vacuum cups to use
27
If we take the example described above, relating to the 140 kg sheet, considering the use of 6 vacuum cups at a level of vacuum of
-60 KPa and a factor of safety 3, we will obtain:
140 x 3
D = 113 x = 122 mm
60 x 6
6 vacuum cups with a diameter equal to or greater than 122 mm will be therefore be required to solve our problem.
∆P = Patm - P1
And again considering a level of vacuum equal to 250 mbar abs. (-75 KPa) inside the vacuum cup, the force exerted by the
atmospheric pressure on the vacuum cup, at an altitude of 1000 metres above sea level, will be:
As can be seen, from a force of 0.778 Kg/cm2 available at sea level, we have gone to 0.657 Kg/cm2 at 1000 metres of altitude. This
confirms that, with decreasing atmospheric pressure, the available force also decreases.
Therefore, in the design phase, always consider the altitude of the place where the vacuum cup lifting system will be installed.
28
SPECIAL CASES OF LIFTING
In all those cases where:
- The gripping surface of the vacuum cups is vertical
- The acceleration and deceleration of the load to be handled is greater than 10 m/s2
- The gripping surface is very rough or uneven
- The load to be supported is permeable
The factor of safety value must be increased according to each of these. Our technicians are at your disposal to define this value.
Cupped vacuum cups These are the most common vacuum cups, used in all industry sectors for the handling
of plastic objects, cardboard boxes, wood panels, thin sheets of metal or glass, etc.,
with very low weight and even rough or irregular surfaces.
They are available in different diameters starting from 4 mm and up to 100 mm.
They are not recommended for vertical handling of heavy objects.
Bellows vacuum cups The particular shape of these bellows cups allows them to quickly crumple up when
in contact with the surface of the load to be lifted and in presence of a vacuum. This
quick movement prevents the load below from remaining stuck to the surfaces or load
underneath. Thanks to this particular feature, these bellows cups are recommended for
handling paper and cardboard sheets, thin metal sheets, wooden panels, glass sheets
etc. Thanks to their great flexibility, they can also be used to compensate flatness errors
or for gripping on inclined surfaces. They are not suitable for vertical handling of heavy
loads.
Flat, round and rectangular vacuum cups Vacuum cups suitable for vertical or horizontal movement of large loads such as
marble or granite slabs.
29
Vacupredator vacuum cups For the gripping of bags, packs and flexible containers in paper or plastic, containing
powders, granulated products, loose or liquid products. These new vacuum cups
have been designed and manufactured to safely grip even the most difficult and
irregular packages.
Foam rubber vacuum cups These vacuum cups are suitable for handling and gripping loads with raw or very
rough surfaces such as sawn, bush-hammered or flamed marble, textured, non-slip
or profiled metal sheets, striped Plexiglass, raw cement manufactures, garden tiles
with fret, etc.
Maxigrip vacuum cups Vacuum cups with a high coefficient of friction, suitable for use in the handling in all
directions of oiled sheets, marble and wet glass, slabs and, in general, loads subject
to high acceleration and deceleration during movement. Especially recommended
for the AUTOMOTIVE sector. Available in various sizes, in round and elliptical flat and
round and elliptical bellows.
Circular rim cups These cups have been designed to meet the need of lifting objects with a central hole.
Their very thin lip allows them to grip very rough surfaces, such as grinding wheels
and discs. They are particularly recommended for CDs, perforated discs, toothed
wheels, pulleys and other similar objects.
Elliptical flat vacuum cups These are recessed on moulders in order to hold a side of the cardboard box during
the moulding process by means of traditional cups on the opposite side. Once
assembled with their support, however, they can be used for handling boxes, plastic
objects or anything with a limited gripping surface.
Special vacuum cups These cups have been designed to solve many of the gripping and handling problems
we have encountered in over forty years of activity. They differ from all the other cups
for the variety of their shapes. They are suited for gripping CDs, labels, bags, paper
or plastic sheets, stickers, chocolates, cardboard, tiles, small metal objects, plastic
objects, etc.
Further information is available on the catalogue pages relative to the vacuum cups listed.
30
GENERAL CHARACTERISTICS OF RUBBER COMPOUNDS
TRADE INTERN. VT POSITIVE NEGATIVE TEMPERATURE OF CHEMICAL FOOD
COLOUR HARDNESS USE
NAME CODE CODE CHARACTERISTICS CHARACTERISTICS USE RESISTANCE STANDARDS
31
32
TRADE INTERN. VT POSITIVE NEGATIVE TEMPERATURE OF CHEMICAL FOOD
COLOUR HARDNESS USE
NAME CODE CODE CHARACTERISTICS CHARACTERISTICS USE RESISTANCE STANDARDS
Fair resistance to
Excellent elastic yield and The softness of the foam rubber makes
sea water, acids Compound not
GERANIUM NR OF resistance to tearing. Poor resistance to Orange From -40 to + 80°C 25 - 30° Sh.A it possible to create vacuum cups for
and medium recommended for
FOAM RUBBER Exceptional elongation at ageing, oils and heat. gripping loads with raw or very rough
concentration food use.
break. surfaces.
alkalis.
The chemical
composition of
the compound
contains exclusively
Magnetic silicone vacuum cups are
Perfect performance at high Modest mechanical substances
Excellent resistance used in the food industry and have
and low temperatures. properties. Can leave authorised by
MAGNETIC ---- SMG Black From -50 to + 250°C 45 - 50° Sh.A to chlorinates, the characteristic of being easily
Highly conductive, marks on the gripping regulation FDA
SILICONE solvents, ozone, detectable by metal detectors used for
magnetically detectable surfaces of vacuum CFR 21: 177-
oxygen and U.V. food protection in case of breakage or
compound. cups if not stabilised. 2600 “ METAL
accidental detachment.
DETECTABLE
COMPOUND - HEAT
CONDUCTIVITY
COMPOUND “
TRADE INTERN. VT POSITIVE NEGATIVE TEMPERATURE OF CHEMICAL FOOD
COLOUR HARDNESS USE
NAME CODE CODE CHARACTERISTICS CHARACTERISTICS USE RESISTANCE STANDARDS
Excellent resistance
Excellent resistance to
to sunlight, flame and This compound is used to produce
chemical deterioration; perfect
Green high temperatures, to Production of non- vacuum cups that are highly qualified
FKM V for lubricants and heat. Poor resistance to From -20 to + 300°C 50 - 60° Sh.A
VITON® Brown aromatic and aliphatic toxic vacuum cups for the mechanical, oil, chemical,
Good compression alkalis and ketones.
hydrocarbons, to not recommended. pharmaceutical, aeronautical and
performance and elastic yield.
chemical agents and nuclear industries.
Does not leave marks.
chlorinated solvents.
Fair resistance to oils. Excellent resistance to Vacuum cups made with this
Poor elastic yield.
Excellent resistance to petroleum products, Production of non- compound are used in the electrical
CR NE Risk of permanent Black From -20 to + 120°C 50 - 70° Sh.A
NEOPRENE® ozone, sea water and ageing. sunlight, atmospheric toxic vacuum cups industry and on handling systems
deformation over
Good resistance to cutting, agents, ozone and not recommended. that operate outside, in contact with
time.
abrasion and combustion. flames. atmospheric agents.
33
TO ORDER VACUUM CUPS
When ordering, it is possible to add the Vuototecnica code related to the desired compound for the item of the vacuum cup you
have chosen. This code can be found in the attached tables in the column “VT CODE”. If, for example, we want to order a traditional
vacuum cup Ø 85 mm in oil-resistant rubber, at the end of the item 01 85 10, which defines the shape of the vacuum cup, we simply
add the letter "A", relative to the oil-resistant rubber, which can be found in the technical table of the compounds. The code thus
obtained, 01 85 10 A, defines both the shape of the vacuum cup and the compound with which it is made. This code does not need
any other description.
To order the same vacuum cup in silicone, simply replace the letter "A" with the letter "S" relative to silicone and you will get code
01 85 10 S. All vacuum cups can be ordered by following this criterion.
Vacuum cups made with different compounds, unless available in stock, are supplied only upon order and in minimum quantities,
to be defined according to their size.
34
VACUUM CUP DIAMETER MATERIAL TO BE GRIPPED
Steel sheet and glass Wood and cardboard
mm m3/h m3/h
4 ÷ 10 0,15 0,30
11 ÷ 20 0,30 0,60
21 ÷ 35 0,50 1,00
36 ÷ 50 1,00 2,00
51 ÷ 85 1,50 3,00
86 ÷ 110 2,00 4,00
111 ÷ 200 2,50 5,00
201 ÷ 300 3,00 6,00
301 ÷ 360 4,00 8,00
Example:
Marble slab 2500 x 1200 x 50 mm Mass 420 kg
6 x 2.5 = 15 m3/h
Note: The values shown in the table refer to the flow rate of rotary vane vacuum pumps. When vacuum generators based on the Venturi
principle are used, the value of the flow rates shown is doubled due to their lower suction efficiency.
COMPARISON BETWEEN PUMP item VTL5 AND VACUUM GENERATOR item 15 03 10 COMPARISON BETWEEN PUMP item RVP 40 AND VACUUM GENERATOR item PVP 40 M
VTL 5 Curve relative to the flow rate (referring to the suction pressure) RVP 40 Curve relative to the flow rate (referring to the suction pressure)
15 03 10 Curve relative to the flow rate (referring to the suction pressure) PVP 40 M Curve relative to the flow rate (referring to the suction pressure)
VACUUM VACUUM
mbar mbar
Therefore, for the same marble slab in the example shown above, the vacuum generator must be calculated as follows:
6 x 5 = 30 m3/h
35
CHOOSING CHECK VALVES, FILTERS, HOSES, SOLENOID VALVES AND
DISTRIBUTORS
All the accessories indicated in the title, necessary for construction of the system, must be chosen based on the suction connection
of the pump or vacuum generator. If, for example, the suction connection of the pump or the generator is G 1/2”, the check valve,
the suction filter, the hose, the vacuum interception solenoid valve and the distributor must have all G 1/2” connections. Vacuum
cup hoses, on the other hand, are already defined by the fitting installed on the vacuum cup holders or proportionate to their
support.
There are numerous applications of Bernoulli's theorem: this theorem explains how air suction occurs in common gas burners, it
accounts for the operation of instruments such as the Venturi tube or the Pitot tube, used for measuring the speed of fluids.
It is possible to explain many phenomena with this theorem, such as the lifting of a plane’s wing or of a light disc in front of a tube
end from which air flows out quickly.
This last phenomenon, seemingly paradoxical, can be explained as follows: the air flowing between the disc with which the duct ends
and the sustained disc moves at a certain speed v and the pressure that reigns in this hollow space has a certain value P1.
As the air flows away from the centre of the hollow space, its speed decreases, finally reducing to stillness at a greater or lesser
distance, in an area where atmospheric pressure obviously reigns P0.
The air below the sustained disc is subjected to this same pressure P0.
In these conditions, disregarding the height h and indicating the density of the fluid with ρ and the acceleration of gravity with g,
the expression relative to the Bernoulli theorem is written:
P1 v2 P0
+ =
ρ g ρ
This explains the subsistence of the disc, which is sucked from the hollow space with a force that overcomes the thrust exerted on
it by the air that flows from the tube, in addition to the weight of the disc.
This phenomenon is exploited for manufacturing vacuum gripping systems (vacuum cups) and handling, with no contact, fragile
objects, such as semiconductor plates, silica discs, solar cells, precious metal foils, films and whatever needs to be handled with
the greatest care.
Our cups based on Bernoulli’s principle are made with anodised aluminium, with stainless steel centre thrust disc.
The silicone rubber pins, located on the cup gripping plane, prevent transverse movements of the gripped object.
Further information on the vacuum accessories listed above can be found by consulting the catalogue on the pages relating to
each of them.
36
TECHNICAL MEMO
Unit of mass - Fundamental SI unit= Kilogram = Kg
(Avoid saying "weight" as the weight is the force deriving from the product of the mass due to the acceleration of local gravity).
Protection against bodies larger than 12.5 mm. Protection against water drops with max inclination
2 Protection against finger contact. 2 of 15°.
Protection against bodies larger than 2.5 mm. Rain protection, against water falling as a spray at
3 Protection against tool contact. 3 any angle up to 60°
Protection against bodies larger than 1 mm. Protection against water splashing from any
4 Protection against the ingress of cables. 4 direction.
6 Total protection against the ingress of dust. 6 Protection against waves or powerful water jets.
Derived from standards CEI 70-1 / IEC 144 / IEC 529 / UTE C 20-010 / DIN 40050
37
INDEX
1 VACUUM CUPS
5 SUCTION FILTERS
10 GRAPHIC DIVISION
11 SPECIAL PRODUCTS
VACUUM CUPS
VACUUM CUPS
Force Volume A B D E F H
Item
Kg mm3 Ø Ø Ø
01 04 10 * 0.03 16 3 1.5 4 6.0 7.0 7.5
01 05 10 * 0.05 23 3 1.5 5 6.0 7.0 8.0
01 06 10 * 0.07 26 3 1.5 6 6.0 7.0 8.0
01 07 07 * 0.10 40 5 2.0 7 6.0 6.0 7.0
01 08 10 * 0.12 66 5 2.5 8 6.0 7.0 8.0
01 09 07 * 0.15 56 5 2.0 9 5.5 6.0 7.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
Hex. 7
A B D E F G H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 01 M5 7 2.90 3 5 10 18 brass 01 04 10 4
01 05 10
01 06 10
00 08 02 M5 7 4.75 3 5 10 18 brass 01 07 07 4
01 08 10
01 09 07
These traditional cup-shaped vacuum cups are suited for gripping and handling
objects with flat, slightly concave or convex surfaces.
This range of widely used cups has diameters ranging from 10 to 45 mm
and are normally available in standard compounds: natural para rubber N,
3D drawings are available on vuototecnica.net
1
VACUUM CUPS
Force Volume A B D E F H
Item
Kg mm3 Ø Ø Ø
01 10 10 * 0.19 227 7 4.0 10 8.5 8.5 11.0
01 12 10 * 0.28 254 8 4.0 12 8.0 9.0 11.0
01 15 10 * 0.44 364 8 4.0 15 8.0 9.5 12.0
01 18 10 * 0.63 502 8 4.0 18 8.0 9.5 12.0
01 20 10 * 0.78 536 8 4.0 20 8.0 9.5 12.0
01 22 10 * 0.95 723 8 4.0 22 8.0 10.0 13.0
01 25 15 * 1.23 1628 12 6.0 25 10.0 11.5 16.0
01 30 15 * 1.76 2055 12 6.0 30 10.0 12.5 17.0
01 35 15 * 2.40 3292 15 10.0 35 10.0 11.5 16.0
01 40 15 * 3.14 4740 15 10.0 40 10.0 12.5 18.0
01 45 15 * 3.98 8553 15 10.0 45 10.0 14.5 23.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A D E F G H T Support For vacuum cup Weight
Item
Ø Ø material item g
Hex. T
00 08 03 G1/8” 5.5 5 8 7.0 20.0 12 brass 01 10 10 9
01 12 10
01 15 10
01 18 10
01 20 10
01 22 10
00 08 05 G1/8” 7.5 5 8 9.5 22.5 12 brass 01 25 15 10
01 30 15
00 08 20 G1/4” 12.0 8 14 10.0 32.0 17 aluminium 01 35 15 11
01 40 15
01 45 15
1
VACUUM CUPS
Force Volume A B D E F H
Item
Kg mm3 Ø Ø Ø
01 10 10 * 0.19 227 7 4.0 10 8.5 8.5 11.0
01 12 10 * 0.28 254 8 4.0 12 8.0 9.0 11.0
01 15 10 * 0.44 364 8 4.0 15 8.0 9.5 12.0
01 18 10 * 0.63 502 8 4.0 18 8.0 9.5 12.0
01 20 10 * 0.78 536 8 4.0 20 8.0 9.5 12.0
01 22 10 * 0.95 723 8 4.0 22 8.0 10.0 13.0
01 25 15 * 1.23 1628 12 6.0 25 10.0 11.5 16.0
01 30 15 * 1.76 2055 12 6.0 30 10.0 12.5 17.0
01 35 15 * 2.40 3292 15 10.0 35 10.0 11.5 16.0
01 40 15 * 3.14 4740 15 10.0 40 10.0 12.5 18.0
01 45 15 * 3.98 8553 15 10.0 45 10.0 14.5 23.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A D E F G H T Support For vacuum cup Weight
Item
Ø Ø material item g
Hex. T
00 08 04 G1/8” 5.5 13 10 7.0 20.0 12 brass 01 10 10 8.1
01 12 10
01 15 10
01 18 10
01 20 10
01 22 10
00 08 14 G1/8” 7.5 13 10 9.5 22.5 12 brass 01 25 15 9.8
01 30 15
00 08 21 G1/4” 12.0 17 13 10.0 27.0 17 aluminium 01 35 15 9.3
01 40 15
01 45 15
VACUUM CUPS
Force Volume A B D E F H
Item
Kg cm3 Ø Ø Ø
01 25 10 * 1.23 1.4 12 6 25 2 3.5 8
01 30 10 * 1.76 1.8 12 6 30 1 3.5 8
01 35 10 * 2.40 2.4 12 6 35 1 3.5 8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A E F H SW Support For vacuum cup Weight
Item
Ø material item g
00 08 08 M6 3.5 10 14.5 3 brass 01 25 10 2.7
01 30 10
01 35 10
00 08 60 G1/8” 4.0 10 14.5 4 brass 01 25 10 5.6
01 30 10
01 35 10
VACUUM CUPS
Force Volume A B C D E F G H I
Item
Kg cm3 Ø Ø Ø Ø
01 45 10 * 3.98 08.1 15 10 -- 45 5 9.5 -- 18 --
01 60 10 * 7.06 18.2 15 10 25 60 4 -- 10 22 2.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A E C Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 22 G1/4” 10 M8 aluminium 01 45 10 5.9
01 60 10
00 08 44 G1/8” -- -- aluminium 01 45 10 5.1
01 60 10
00 08 313 M6 -- -- brass 01 45 10 3.3
01 60 10
00 08 314 M8 -- -- brass 01 45 10 4.3
01 60 10
00 08 92 M10 -- -- brass 01 45 10 5.2
01 60 10
VACUUM CUPS
Force Volume A B C D E G H I
Item
Kg cm3 Ø Ø Ø Ø
01 85 10 * 14.18 54.8 25 15 25 85 16 23 41 4.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A D Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 28 G1/4” 25 aluminium 01 85 10 13.4
00 08 136 G1/8” 25 aluminium 01 85 10 9.2
00 08 91 M10x1,25 25 brass 01 85 10 38.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.06
VACUUM CUPS WITH SUPPORTS
VACUUM CUPS
Force Volume A B C D F G H I
Item
Kg cm3 Ø Ø Ø Ø
01 85 10 * 14.18 54.8 25 15 25 85 16 23 41 4.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B Support For Vacuum cup Weight
Item
Ø Ø material item g
00 08 29 15.5 M12 aluminium 01 85 10 6.6
00 08 46 15.5 G1/4” aluminium 01 85 10 6.5
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.07
VACUUM CUPS WITH VULCANISED SUPPORT
ADAPTERS
D d H Support Weight
Item
Ø Ø material g
00 08 130 G1/4” M10 14 steel 04.9
00 08 131 G3/8” M10 14 steel 12.8
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.08
VACUUM CUPS WITH VULCANISED SUPPORT
08 100 40 * 19.62 42.6 32 G3/8” -- 100 26.0 12 09.0 39.0 steel 78.3
08 100 50 * 19.62 70.6 32 G3/8” -- 100 30.5 12 15.0 43.5 steel 74.8
08 50 40 1/4” B 04.90 10.3 31 G1/4” -- 50 16.0 -- 06.5 29.0 steel 37.4
08 75 40 1/4” B 11.04 29.3 31 G1/4” -- 75 25.0 -- 09.0 38.0 steel 57.6
08 100 40 1/4” B 19.62 42.6 32 G1/4” -- 100 26.0 -- 09.0 39.0 steel 76.8
08 50 40 M10 B 04.90 10.3 31 M10 -- 50 16.0 -- 06.5 29.0 steel 32.7
08 100 50 M10 B 19.62 70.6 32 M10 -- 100 30.5 -- 15.0 43.5 steel 70.2
08 75 40 M14 B 11.04 29.3 31 M14 x 1.5 -- 75 25.0 -- 09.0 38.0 steel 54.9
08 100 50 M14 B 19.62 70.6 32 M14 x 1.5 -- 100 30.5 -- 15.0 43.5 steel 74.9
* Complete the code indicating the compound: B= BENZ rubber; N= natural para rubber; S = silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.09
VACUUM CUPS WITH
VULCANISED SUPPORT
These vacuum cups are very similar to those
described on the previous page: they differ only for
their round lip and their internal cleats.
These features allow them to be used even in the
3D drawings are available on vuototecnica.net
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.10
MAXIGRIP CUPS
These vacuum cups have been created as an alternative to the ordinary cups used
in the robot-automotive field. They offer an excellent solution to gripping and
handling problems that could arise on vacuum-driven handlers in every
industry sector.
VRS 40* 03.14 009.7 043 030 G1/4” 17 040 024 21.0 10 07.0 35.0 14 G1/8” steel 056.3
VRS 50* 04.90 015.6 053 040 G3/8” 22 050 034 21.0 10 07.0 36.0 15 G1/4” steel 077.6
VRS 60* 07.06 022.8 063 050 G3/8” 22 060 044 21.0 10 07.0 36.0 15 G1/4” steel 107.9
VRS 80* 12.56 047.3 083 070 G3/8” 22 080 064 23.0 10 09.0 38.0 15 G1/4” steel 205.9
VRS 100* 19.62 104.2 103 080 G3/8” 22 100 079 29.0 10 13.0 44.0 15 G1/4” steel 269.0
VRS 125* 30.66 202.5 128 105 G3/8” 22 125 100 32.5 10 16.5 47.5 15 G1/4” steel 464.2
* Complete the code indicating the compound: B= BENZ rubber; N= natural para rubber; S = silicone
Note: Height "C" available with NPT threading. Ordering example: VRS 80 NPT B
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.11
FLAT AND BELLOWS ELLIPTICAL VACUUM CUPS
3D drawings are available on vuototecnica.net
1 Sp
Sp
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.12
ADAPTERS FOR MAXIGRIP VACUUM CUPS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.13
ACCESSORIES FOR MAXIGRIP VACUUM CUPS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.14
ROUND FLAT VACUUM CUPS WITH SUPPORTS
The cups described on this page have been designed to solve most of
the gripping problems that can arise handling wooden or plastic panels,
thin glass or marble sheets, fragile metal sheets, ceramic or baked clay
tiles, etc.
VACUUM CUPS
Force Volume A B C D F G H M
Item 1
Kg cm3 Ø Ø Ø Ø Ø
01 76 24 * 11.33 15.8 54 35 16 76 4.5 10 24 36
01 90 24 * 15.89 19.5 64 35 16 90 4.5 10 24 36
01 110 24 * 23.74 27.2 79 35 16 110 4.5 10 24 36
01 150 36 * 45.00 75.8 98 70 16 150 6.0 17 36 70
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A C D E F G H I Support/ring nut For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 108 G1/4” 34 35 9 19.5 4.5 33.0 4.5 aluminium 01 76 24 31.2
01 90 24
01 110 24
00 08 110 G3/8” 34 35 9 19.5 4.5 33.0 4.5 aluminium 01 76 24 33.7
01 90 24
01 110 24
00 08 112 G3/8” 69 69 15 22.0 5.5 42.5 6.0 aluminium 01 150 36 132.1
Note: the ring nut is provided automatically when the support is ordered with its own item
VACUUM CUP
Force Volume A B C D F H
Item
Kg cm3 Ø Ø Ø Ø
01 56 15 * 6.15 7.1 56 48 44 56 11 15
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORT
A B C D F H Support For vacuum cup Weight
Item
Ø Ø Ø Ø material item g
00 08 83 48.5 M12 5 48.5 11 14.5 aluminium 01 56 15 67.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.16
ROUND FLAT VACUUM CUP WITH SUPPORTS
VACUUM CUP
Force Volume A B C D H M
Item
Kg cm3 Ø Ø Ø Ø Ø
01 80 20 * 12.56 27.2 58 54 45 80 20 17
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B D E H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 126 45 M12 54 3 10 aluminium 01 80 20 45.5
00 08 465 45 G1/4” 54 3 10 aluminium 01 80 20 41.5
00 08 193 45 G3/8” 54 3 10 aluminium 01 80 20 41.5
00 08 143 45 G1/2” 54 3 10 aluminium 01 80 20 41.5
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.17
ROUND FLAT VACUUM CUPS WITH SUPPORTS
These cups have been designed in particular for handling metal sheets,
glass, wooden panels, machined marble and granite and other similar
materials.
The shape of their lips allows a firm grip of the surface of the load to be
3D drawings are available on vuototecnica.net
VACUUM CUPS
Force Volume A B C D E F H M N O
Item
Kg cm3 Ø Ø Ø Ø Ø Ø
01 65 15 * 8.29 9.1 68 63 59 65 3 7 17 -- 27 --
01 65 16 * 8.29 9.1 68 63 59 65 3 7 17 21 27 4.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B C D E H M For vacuum cup Support Weight
Item
Ø Ø Ø Ø item material g
00 08 32 60 M12 -- 64 3 10 -- 01 65 15 aluminium 80.6
00 08 424 60 G1/4” -- 64 3 10 -- 01 65 15 aluminium 80.6
00 02 36 60 M8 G1/4” 64 3 10 21 01 65 16 aluminium 78.1
00 06 13 60 M12 G1/4” 64 3 10 21 01 65 16 aluminium 77.1
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.18
ROUND FLAT VACUUM CUPS WITH SUPPORTS
VACUUM CUPS
Force Volume A B C D E F H M N O
Item
Kg cm3 Ø Ø Ø Ø Ø Ø
01 85 15 * 14.18 13.0 68 63 59 85 3 7 17 -- 27 --
01 85 16 * 14.18 13.0 68 63 59 85 3 7 17 21 27 4.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B C D E H M For vacuum cup Support Weight
Item
Ø Ø Ø Ø item material g
00 08 32 60 M12 -- 64 3 10 -- 01 85 15 aluminium 80.6
00 08 234 60 G1/2” -- 64 3 10 -- 01 85 15 aluminium 78.3
00 08 424 60 G1/4” -- 64 3 10 -- 01 85 15 aluminium 80.6
00 08 233 60 G3/4” -- 64 3 10 -- 01 85 15 aluminium 77.3
00 02 36 60 M8 G1/4” 64 3 10 21 01 85 16 aluminium 78.1
00 06 13 60 M12 G1/4” 64 3 10 21 01 85 16 aluminium 77.1
VACUUM CUP
Force Volume A B C D E F H N
Item
Kg cm3 Ø Ø Ø Ø Ø
01 110 10 * 23.74 24.9 96 91 87 114 3 8 17 54
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B C D E H M For vacuum cup Support Weight
Item
Ø Ø Ø Ø item material g
00 08 33 88 M12 -- 92 3 11 -- 01 110 10 aluminium 188.9
00 02 37 88 M8 G1/4” 92 3 11 26 01 110 10 aluminium 188.8
00 06 14 88 M12 G1/4” 92 3 11 26 01 110 10 aluminium 185.8
00 08 123 88 G3/8” -- 92 3 11 -- 01 110 10 aluminium 186.1
VACUUM CUP
Force Volume A B C D E F H N
Item
Kg cm3 Ø Ø Ø Ø Ø
01 150 10 * 45.00 75.7 133 125 118 154 4 11 23 64
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B C D E H M For vacuum cup Support Weight
Item
Ø Ø Ø Ø item material g
00 08 35 120 M12 -- 127 4 15 -- 01 150 10 aluminium 471.3
00 08 107 120 M12 G3/8” 127 4 15 30 01 150 10 aluminium 476.9
00 08 119 120 G3/8” -- 127 4 15 -- 01 150 10 aluminium 478.9
00 08 145 120 G3/8” G3/8” 127 4 15 27 01 150 10 aluminium 471.9
00 06 15 120 M12 G1/4” 127 4 15 30 01 150 10 aluminium 476.3
VACUUM CUP
Force Volume A B D H Compound
Item
Kg cm3 Ø Ø Ø
01 220 10 A 78.5 203.4 180 180 220 20 oil-resistant rubber
SUPPORT
A B C D H M Support For vacuum cup Weight
Item
Ø Ø Ø Ø material item Kg
00 08 37 180 M12 G3/8” 206 12 70 aluminium 01 220 10 A 0.95
NBR rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.22
ROUND FLAT VACUUM CUP WITH SUPPORT
VACUUM CUP
Force Volume A B C D E F H N
Item
Kg cm3 Ø Ø Ø Ø Ø
01 250 20 * 122.60 200.0 235 227 220 254 4 11 23 220
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORT
A B C D E H M For vacuum cup Support Weight
Item
Ø Ø Ø Ø item material Kg
00 08 115 223 M12 G3/8” 230 4 15 70 01 250 20 aluminium 1.65
These foam rubber cups are made with a special compound called GERANIUM, with a
density that allows them to grip even uneven and very rough surfaces maintaining their
elasticity also after many working cycles. They are provided with self-adhesive side for
a quick fixing to their support. This series of cups has been designed for handling loads
3D drawings are available on vuototecnica.net
with raw or very rough surfaces (sawn, bush-hammered or flamed marble, textured,
non-slip or profiled metal sheets, striped Plexiglass, raw cement manufactures, garden
tiles with fret, etc.) and in all those cases in which traditional cups
cannot be used.
In case of lubricated gripping surfaces, we recommend using
NF neoprene foam rubber. The working temperature range
is between -40°C and +80°C for OF GERANIUM foam rubber
and between -20°C and +80°C for NF neoprene.
Their supports are made with anodised aluminium and are
provided with a threaded hole in the centre for fastening them
to the automation. The larger ones, on the other hand, have a
side threaded hole for vacuum connection.
For the spare part, all you have to do is request the self-adhesive foam rubber cup
indicated in the table in the required compound.
1
VACUUM CUPS
Force Volume D d E
Item
Kg cm3 Ø Ø
01 42 15 * 0.78 04.7 40 20 15
01 64 15 * 3.5 18.8 64 40 15
01 92 15 * 8.5 48.2 92 64 15
* Complete the code indicating the compound: OF= geranium foam rubber; NF= neoprene foam rubber
Self-adhesive side
SUPPORTS
A B D F H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 147 40 M12 40 -- 10 aluminium 01 42 15 32.8
00 08 118 40 G1/4” 40 -- 10 aluminium 01 42 15 32.8
00 08 32 60 M12 64 3 10 aluminium 01 64 15 80.6
00 08 424 60 G1/4” 64 3 10 aluminium 01 64 15 80.6
00 08 33 88 M12 92 3 11 aluminium 01 92 15 188.9
00 08 123 88 G3/8” 92 3 11 aluminium 01 92 15 186.1
Self-adhesive side
VACUUM CUPS
Force Volume D d E
Item
Kg cm3 Ø Ø
01 127 15 * 17.5 99.6 127 92 15
01 180 15 * 38.5 230.7 180 140 15
01 220 15 * 63.6 381.5 220 180 15
* Complete the code indicating the compound: OF= geranium foam rubber; NF= neoprene foam rubber
SUPPORT
A B C D F H M Support For vacuum cup Weight
Item
Ø Ø Ø Ø material item Kg
00 08 107 120 M12 G3/8” 127 4 15 30 aluminium 01 127 15 0.48
00 08 58 160 M12 G3/8” 180 5 12 60 aluminium 01 180 15 0.74
The detail that sets these cups apart from the previously described cups is
its lip, made of nitrile rubber, combined with foam rubber in the GERANIUM
compound or neoprene compound. This shape allows for gripping on very
rough or even grooved surfaces. They are especially suitable for gripping and
3D drawings are available on vuototecnica.net
handling cement objects with surfaces finished with fret, marble and bush-
hammered or flamed granites.
The working temperature range is between -40°C and +80°C for OF
GERANIUM foam rubber and between -20°C and +80°C for NF neoprene.
The support is made with anodised aluminium and is provided with a threaded
hole in the centre for fastening them to the automation, and a side threaded
hole for vacuum connection. The cup is cold fitted on it without the use of
adhesives. To replace, simply request the single vacuum cup indicated in the
table in the desired compound.
VACUUM CUPS
Force Volume A B D H Compound
Item
Kg cm3 Ø Ø Ø
01 220 10 OF 63.6 585.0 180 180 220 35 geranium foam rubber
01 220 10 NF 63.6 585.0 180 180 220 35 neoprene foam rubber
SUPPORT
A B C D H M Support For vacuum cup Weight
Item
Ø Ø Ø Ø material item Kg
00 08 37 180 M12 G3/8” 206 12 70 aluminium 01 220 10 0.95
Oil-resistant
rubber
Foam rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.26
VACUPREDATOR VACUUM CUPS FOR GRIPPING BAGS, PACKS AND FLEXIBLE CONTAINERS
Slotted plate
Slotted plate
Air inlet connection (F)
Support
Support
Fastenings for Cap
the automation Cap
Spacers
Spacers
Vacuum Effective
connection Effective
gripping area (T)
gripping area (T) Cap
Cap
Foam rubber
Nitrile rubber combined
with foam rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.27
VACUPREDATOR VACUUM CUPS FOR GRIPPING BAGS,
PACKS AND FLEXIBLE CONTAINERS
3D drawings are available on vuototecnica.net
1
Slotted plate
Support
Cap
Fastenings for
the automation
Spacers
Cap
Vacuum Effective
connection gripping area (T)
Foam rubber
CODING EXAMPLE:
3 seats at 120°
for TCCE M4 screws
These cups have been designed for lifting and handling heavy
loads, both vertically and horizontally. They are vulcanised onto a
steel support and are provided with a central threaded hole for its
fastening to the automation and with a side threaded hole for vacuum
3D drawings are available on vuototecnica.net
connection.
These cups have a labyrinth graved face made with the same
compound as the cup, which allows gripping even the thinnest and
most fragile glass and marble sheets, with no bending in the gripping
area. The shape of its lip and the choice of the compound with which
they are made ensure a firm grip on uneven and corrugated surfaces.
The 08 .. 40 series, along with sharing the same features, has an
internal vertical lip which allows them to grip extremely rough
surfaces, such as embossed or profiled metal sheets, sawn marble or
granite, wooden boards, precast cement, etc.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.31
CIRCULAR RIM VACUUM CUPS WITH SUPPORTS
These cups have been designed to meet the need of lifting objects with
a central hole.
Their very thin lip allows them to grip very rough surfaces, such as
grinding wheels and discs.
3D drawings are available on vuototecnica.net
4 holes Ø 1 at 90°
VACUUM CUP
Force Volume A B D d F H
Item
Kg cm3 Ø Ø Ø Ø Ø
01 24 06 S 0.6 1.3 25.5 15.5 24 16.5 20 6
Compound: S= silicone
SUPPORT
A B D E F H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 232 15 G1/8” 30 10 4 14 aluminium 01 24 06 16.7
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.32
CIRCULAR RIM VACUUM CUP WITH SUPPORT
VACUUM CUP
Force Volume A B D d F H
Item
Kg cm3 Ø Ø Ø Ø Ø
01 31 06 S 1.25 2.0 31.5 21.5 31 18 24.5 6
Compound: S= silicone
SUPPORT
A B D E F H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 231 15 G1/8” 36 10 4 14 aluminium 01 31 06 24.9
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.33
CIRCULAR RIM VACUUM CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
VACUUM CUPS
Force Volume A B C D d E H M
Item
Kg cm3 Ø Ø Ø Ø Ø Ø
01 46 13 N 3.87 4.7 35 23 3 46 12 8.5 12.5 29
01 73 14 N 9.02 16.6 60 40 5 73 27 10.0 14.0 50
01 95 14 N 16.28 27.0 71 51 6 95 27 10.0 14.5 61
4 holes at 90°
Compound: N = natural para rubber
SUPPORTS
A B C D E F G H N Support For vacuum cup Weight
Item
Ø Ø Ø Ø Ø material item g
00 08 68 40 M12 23 35 7 10 18 25 20 aluminium 01 46 13 47.2
00 08 72 65 G3/8” 40 60 10 15 25 35 25 aluminium 01 73 14 169.1
00 08 73 76 G3/8” 51 71 10 15 27 37 25 aluminium 01 95 14 266.0
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.34
RECTANGULAR FLAT VACUUM CUPS WITH SUPPORTS
These cups are recommended for working surfaces for clamping wooden panels,
marble, granite, ceramic, glass and other similar surfaces. They are naturally also used
to handle these same materials. Their vertical and low lip allows for a firm grip on
the surface to be clamped or handled, eliminating any oscillations and considerably
VACUUM CUPS
Force Volume A B E F G H L M N O P Q
Item
Kg cm3
01 40 75 * 6.7 9.2 64 29 3 7.5 6.5 16.0 75 40 59 24 54 19
01 120 90 * 24.0 42.9 107 78 3 7.5 7.5 17.5 117 87 102 73 97 68
01 150 65 A 21.5 36.6 137 52 3 7.5 7.5 16.5 147 62 132 47 127 42
01 150 75 * 25.0 43.5 137 62 3 7.5 7.5 16.5 147 72 132 57 127 52
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
N O P Q Support For vacuum cup Weight
Item
material item g
00 08 31 60 25 55 20 aluminium 01 40 75 34.1
00 08 34 107 75 102 70 aluminium 01 120 90 215.5
00 08 144 135 50 130 45 aluminium 01 150 65 176.1
00 08 59 135 60 130 55 aluminium 01 150 75 218.4
VACUUM CUPS
Force Volume A B E F G H L M N O P Q
Item
Kg cm3
01 300 80 * 60.0 117.6 288 68 3 7.5 7.5 17.5 297 77 284 64 278 58
01 300 150 * 113.0 268.5 288 138 3 7.5 7.5 17.5 297 147 284 134 278 128
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
D N O P Q Support For vacuum cup Weight
Item
Ø material item Kg
00 08 116 G3/8” 290 68 284 62 aluminium 01 300 80 0.53
00 08 117 G1/2” 290 140 284 134 aluminium 01 300 150 1.13
These cups share the same technical and mechanical features with
the ones described above, but their support has a special non-slip
plastic coating that make them particularly suited for clamping glass
and smooth marble.
VACUUM CUP
Force Volume A B E F G H L M N O P Q
Item
Kg cm3
01 40 75 * 6.7 9.2 64 29 3 7.5 6.5 16.0 75 40 59 24 54 19
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Filter
O-ring
SUPPORT
N O P Q Support For vacuum cup Weight
Item
material item g
00 08 184 60 25 55 20 aluminium 01 40 75 38.7
VACUUM CUPS
Force Volume A B E F G H L M N O P Q
Item
Kg cm3
1 01 120 90 * 24.0 42.9 107 78 3 7.5 7.5 17.5 117 87 102 73 97 68
01 150 75 * 25.0 36.6 137 62 3 7.5 7.5 16.5 147 72 132 57 127 52
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Non-slip
plastic
coating
SUPPORTS
A B C H L M N O P Q Support For vacuum cup Weight
Item
material item g
00 08 256 82 50 2.5 16.2 30 56 107 75 102 70 aluminium 01 120 90 244.5
00 08 257 110 35 2.3 16.4 20 92 135 60 130 55 aluminium 01 150 75 247.9
These foam rubber cups are made with a special compound called GERANIUM, with
code OF, with a density that allows them to grip even uneven and very rough surfaces
maintaining their elasticity also after many working cycles.
They are provided with self-adhesive side for a quick fixing to their support.
Self-adhesive side
VACUUM CUPS
Force Volume A B C E
Item
Kg cm3
01 107 75 * 9.0 55.6 107 75 15 15
01 135 50 * 6.0 34.0 135 50 15 15
01 135 60 * 8.0 50.0 135 60 15 15
* Complete the code indicating the compound: OF= geranium foam rubber; NF= neoprene foam rubber
SUPPORTS
A B D E H M N Support For vacuum cup Weight
Item
material item g
00 08 34 107 75 70 3 11 102 70 aluminium 01 107 75 215.5
00 08 144 135 50 45 3 11 130 45 aluminium 01 135 50 176.1
00 08 59 135 60 55 3 11 130 55 aluminium 01 135 60 218.4
Self-adhesive side
VACUUM CUPS
Force Volume A B C E
Item
Kg cm3
01 290 68 * 25 152.6 290 68 15 15
01 290 140 * 72 434.5 290 140 15 15
* Complete the code indicating the compound: OF= geranium foam rubber; NF= neoprene foam rubber
SUPPORTS
A B D E H M N Support For vacuum cup Weight
Item
Ø material item Kg
00 08 116 290 68 G3/8” 3 11 284 62 aluminium 01 290 68 0.53
00 08 117 290 140 G1/2” 3 11 284 134 aluminium 01 290 140 1.13
2 seats
for TCCE M4 screws
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.41
ELLIPTICAL FLAT VACUUM CUPS WITH SUPPORTS
VACUUM CUP
Force Volume A B C D
Item
Kg cm3
01 12 20 * 0.52 0.3 15 11.5 17 20
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORT
B E F Support For vacuum cup Weight
Item
Ø material item g
00 08 70 G1/8” 8.5 6.5 aluminium 01 12 20 5.4
Note: Supplied automatically also with the fixing plate and the perforated
TSP screw when ordering item 00 08 70
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.42
ELLIPTICAL FLAT VACUUM CUPS WITH SUPPORTS
VACUUM CUPS
Force Volume A B C D
Item
Kg cm3
01 12 30 * 0.82 0.5 25 21.5 27 30
01 12 40 * 1.12 0.7 35 31.5 37 40
01 12 50 * 1.57 1.0 50 46.5 52 55
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B C E F Support For vacuum cup Weight
Item
Ø material item g
00 08 71 30 G1/8” 25 8.5 6.5 aluminium 01 12 30 7.8
00 08 75 40 G1/8” 35 8.5 6.5 aluminium 01 12 40 11.4
00 08 76 55 G1/8” 50 8.5 6.5 aluminium 01 12 50 15.5
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.43
FLAT AND BELLOWS ELLIPTICAL VACUUM CUPS WITH SUPPORTS
Complete range of flat elliptical vacuum cups, normally used for gripping, handling and
clamping cardboard cases and boxes, wood shingles, small ceramic or brick tiles, iron or
stainless steel profiles, sheets and anything else present on long, narrow gripping
surfaces.
3D drawings are available on vuototecnica.net
Instead, bellows elliptical vacuum cups, in addition to having the same function
as the flat cups described above, are able to adapt to the gripping plane, even if
not perfectly perpendicular to the axis of the vacuum cup, and can
recover evident unevenness of the loads to be lifted.
They are normally available in the three standard compounds but
can be supplied in special compounds listed on pg. 31 and in a
minimum amount to be defined in the order, upon request.
Both items can be supplied with or without automation fastening
support. Upon request, special non-rotating vacuum cup holders on
which to assemble them are able to prevent their rotation during use.
1 VACUUM CUPS
Force A B C D E F G H I L Volume
Item
Kg Ø Ø Ø cm3
VOP 08 24 SR * 0.44 12.2 7.3 2.5 24 11.2 5.5 0.8 12.0 6.7 8.0 0.191
VOP 10 30 SR * 0.69 12.2 7.3 4.5 30 11.3 5.5 0.7 12.0 7.0 10.0 0.214
VOP 12 36 SR * 0.98 12.0 7.3 5.0 36 12.1 5.5 0.9 13.0 6.4 12.0 0.498
VOP 15 45 SR * 1.56 16.4 13.0 4.0 45 20.1 8.8 1.9 22.0 14,3 15.0 1.203
VOP 20 60 SR * 2.73 18.0 13.0 8.0 60 20.0 9.0 1.5 21.5 10.0 20.0 2.026
VOP 25 75 SR * 4.30 17.8 13.0 8.0 75 19.1 9.0 2.2 21.3 7.6 25.0 5.026
VOP 28 85 SR * 5.53 18.6 13.0 8.0 85 18.9 9.7 2.8 21.7 8.7 28.0 6.761
VOP 35 100 SR * 8.09 18.8 13.0 8.0 100 18.9 9.7 3.3 22.2 8.7 35.0 11.989
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
MALE SUPPORTS
A B D E F G H Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 344 G1/8” 14 7.3 7 7 5.5 19.5 aluminium VOP 08 24 SR 18.5
Hex. B
VOP 10 30 SR
VOP 12 36 SR
00 08 346 G1/4” 17 13.0 8 8 9.0 25.0 aluminium VOP 15 45 SR 25.0 screw
00 08 404 G1/4” 17 13.0 8 8 9.0 25.0 aluminium VOP 20 60 SR 29.8 item 00 08 347 for supp.00 08 402
VOP 25 75 SR item 00 08 348 for supp.00 08 404
00 08 402 G1/4” 17 13.0 8 8 9.0 25.0 aluminium VOP 28 85 SR 30.7
VOP 35 100 SR Note: Supplied automatically also with the screw
when ordering the item relative to the support
Hex. B
FEMALE SUPPORTS
A B D E F G H Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 343 G1/8” 14 7.3 10 8.0 5.5 15.5 aluminium VOP 08 24 SR 16.8 Hex. B
VOP 10 30 SR
VOP 12 36 SR
00 08 345 G1/4” 17 13.0 12 8.5 9.0 21.0 aluminium VOP 15 45 SR 19.9 screw
00 08 405 G1/4” 17 13.0 12 8.5 9.0 21.0 aluminium VOP 20 60 SR 24.7 item 00 08 347 for supp.00 08 403
VOP 25 75 SR item 00 08 348 for supp.00 08 405
00 08 403 G1/4” 17 13.0 12 8.5 9.0 21.0 aluminium VOP 28 85 SR 25.6
VOP 35 100 SR Note: Supplied automatically also with the screw
when ordering the item relative to the support
Hex. B
VACUUM CUPS
Force A B C D E F G H L Volume
Item
Kg Ø Ø Ø bellows stroke cm3
VOS 08 25 * 0.51 10.0 7.3 1.3 25.0 12.4 6.0 3.0 18.4 8.0 0.852
VOS 15 45 * 1.56 17.2 13.0 4.0 45.0 18.6 10.0 6.5 28.6 15.0 4.978
VOS 25 75 * 4.30 17.2 13.0 9.0 75.0 25.2 9.0 8.5 34.2 25.0 23.083
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
screw
item 00 08 347 for supp.00 08 402
MALE SUPPORTS
A B D E F G H Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 344 G1/8” 14 7.3 7 7 5.5 19.5 aluminium VOS 08 25 18.5
00 08 346 G1/4” 17 13.0 8 8 9.0 25.0 aluminium VOS 15 45 25.0
00 08 402 G1/4” 17 13.0 8 8 9.0 25.0 aluminium VOS 25 75 30.7
Hex. B
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.46
ELLIPTICAL BELLOWS VACUUM CUPS WITH FEMALE SUPPORTS
VACUUM CUPS
Force A B C D E F G H L Volume
Item
Kg Ø Ø Ø bellows stroke cm3
VOS 08 25 * 0.51 10.0 7.3 1.3 25.0 12.4 6.0 3.0 18.4 8.0 0.852
VOS 15 45 * 1.56 17.2 13.0 4.0 45.0 18.6 10.0 6.5 28.6 15.0 4.978
VOS 25 75 * 4.30 17.2 13.0 9.0 75.0 25.2 9.0 8.5 34.2 25.0 23.083
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
screw
item 00 08 347 for supp.00 08 403
FEMALE SUPPORTS
A B D E F G H Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 343 G1/8” 14 7.3 10 8.0 5.5 15.5 aluminium VOS 08 25 16.8
00 08 345 G1/4” 17 13.0 12 8.5 9.0 21.0 aluminium VOS 15 45 19.9
00 08 403 G1/4” 17 13.0 12 8.5 9.0 21.0 aluminium VOS 25 75 25.6
Hex. B
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.47
ELLIPTICAL VACUUM CUPS WITH VULCANISED SUPPORT
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.48
CONCAVE VACUUM CUPS WITH VULCANISED SUPPORT
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.49
OF FOAM RUBBER SHEETS AND STRIPS
The foam rubber used for our cups can be provided in sheets or strips
of the sizes indicated in the table.
Both the OF foam rubber strips and the sheets have a self-adhesive
side which allows a quick and easy fixing to the metal support.
3D drawings are available on vuototecnica.net
These sheets and strips can be used to make cups of every shape and
to handle loads with raw or very rough surfaces. They can be supplied
in different sizes and density upon request and in quantities to be
defined in the order.
The working temperature ranges from -40°C to +80°C.
Excellent compressive and breaking strength, with elongation up to
350%. Poor resistance to oils, ozone and flame.
NOTE: OF foam rubber is obtained by the expansion of a natural
rubber, subjected to leavening through a chemical-thermal
treatment.
Surface porosity with the same density, therefore, can vary, not
compromising its effectiveness.
Self-adhesive side
OF FOAM RUBBER SHEETS
A B E
Item
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.50
SB EXTRA SOFT FOAM RUBBER SHEETS
1
SB EXTRA SOFT FOAM RUBBER SHEETS
Self-adhesive side
A B E
Item
A B E
Item
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.51
BELLOWS CUPS WITH SUPPORTS
FOR GRIPPING FLOW PACKS
Thanks to their specific conformation and flexibility,
the vacuum cups illustrated and described on
this page are especially suitable for installation
on automatic, high production machines in the
3D drawings are available on vuototecnica.net
VACUUM CUPS
Force Volume A B C D E F H Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
01 20 30 S 0.78 3.0 13 8 12 20 10 11.5 30 11
01 30 45 S 1.76 11.4 18 11 19 30 16 19.0 45 20
Compound: S= silicone
Hex. 17
SUPPORTS
D E F G H Support For vacuum cup Weight
Item
Ø material item g
00 08 18 9.5 8 14 10 32 aluminium 01 20 30 10.3
00 08 127 13.5 8 14 15 37 aluminium 01 30 45 11.5
Sp B
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.52
BELLOWS VACUUM CUPS WITH MALE AND FEMALE SUPPORTS
VACUUM CUPS
Force Volume A B C D E F H Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
01 20 23 * 0.78 3.4 14.5 5.0 14 20 5 4 23 16
01 30 32 * 1.76 11.4 20.0 6.5 21 30 7 5 32 22
01 40 42 * 3.14 33.0 20.0 6.5 28 40 7 5 42 32
01 50 53 * 4.90 53.3 27.0 10.5 35 50 10 6 53 32
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
MALE SUPPORTS
A B C D E F G H Support For vacuum cup Weight Sp B
Item
Ø Ø Ø material item g
00 08 133 14.5 13 G1/8” 8.5 5.5 8 5.0 18.5 aluminium 01 20 23 3.5
00 08 135 20.0 17 G1/4” 10.0 7.5 12 7.5 27.0 aluminium 01 30 32 9.5
01 40 42
00 08 142 27.0 22 G1/4” 14.0 7.5 12 9.5 29.0 aluminium 01 50 53 15.7
Sp B
VACUUM CUPS WITH MALE SUPPORT
Force A B C D E F G H Vacuum cup Support Weight
Item
Kg Ø Ø Ø item item g
08 20 23 * 0.78 14.5 13 G1/8” 20 5.5 8 23 36.5 01 20 23 00 08 133 5.3
08 30 32 * 1.76 20.0 17 G1/4” 30 7.5 12 32 51.5 01 30 32 00 08 135 15.1
08 40 42 * 3.14 20.0 17 G1/4” 40 7.5 12 42 61.5 01 40 42 00 08 135 21.1
08 50 53 * 4.90 27.0 22 G1/4” 50 7.5 12 53 72.5 01 50 53 00 08 142 40.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.53
BELLOWS VACUUM CUPS WITH FEMALE SUPPORTS
3D drawings are available on vuototecnica.net
VACUUM CUPS
Force Volume A B C D E F H Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
01 20 23 * 0.78 3.4 14.5 5.0 14 20 5 4 23 16
01 30 32 * 1.76 11.4 20.0 6.5 21 30 7 5 32 22
01 40 42 * 3.14 33.0 20.0 6.5 28 40 7 5 42 32
01 50 53 * 4.90 53.3 27.0 10.5 35 50 10 6 53 32
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
FEMALE SUPPORTS
A B C D E F G H Support For vacuum cup Weight Sp B
Item
Ø Ø Ø material item g
00 08 132 14.5 13 G1/8” 8.5 12 8 5.0 17.0 aluminium 01 20 23 3.8
00 08 134 20.0 17 G1/4” 10.0 14 10 7.5 21.5 aluminium 01 30 32 8.3
01 40 42
00 08 141 27.0 22 G1/4” 14.0 14 10 9.5 23.5 aluminium 01 50 53 19.7
Sp B
VACUUM CUPS WITH FEMALE SUPPORT
Force A B C D E F G H Vacuum cup Support Weight
Item
Kg Ø Ø Ø item item g
08 20 23 F * 0.78 14.5 13 G1/8” 20 12 8 23 35 01 20 23 00 08 132 5.6
08 30 32 F * 1.76 20.0 17 G1/4” 30 14 10 32 46 01 30 32 00 08 134 13.9
08 40 42 F * 3.14 20.0 17 G1/4” 40 14 10 42 56 01 40 42 00 08 134 19.9
08 50 53 F * 4.90 27.0 22 G1/4” 50 14 10 53 67 01 50 53 00 08 141 44.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
00 08 295 17 01 20 23
00 08 293 27 01 30 32
00 08 279 35 01 40 42
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.54
REINFORCED BELLOWS VACUUM CUPS
WITH MALE AND FEMALE SUPPORTS
VACUUM CUPS
Force Volume A B C D E F H Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
01 22 19 * 0.95 2.5 14.5 5.0 11.0 22 4 5.5 19 10
01 34 26 * 2.26 8.0 14.5 5.0 17.0 34 4 5.5 26 12
01 43 28 * 3.62 15.3 20.0 6.5 21.5 43 4 7.0 28 14
01 53 35 * 5.51 30.5 27.0 10.5 30.5 53 6 9.5 35 16
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
MALE SUPPORTS
Sp B
A B C D E F G H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 133 14.5 13 G1/8” 8.5 5.5 8 5.0 18.5 aluminium 01 22 19 3.5
01 34 26
00 08 135 20.0 17 G1/4” 10.0 7.5 12 7.5 27.0 aluminium 01 43 28 9.5
00 08 142 27.0 22 G1/4” 14.0 7.5 12 9.5 29.0 aluminium 01 53 35 15.7
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.55
REINFORCED BELLOWS VACUUM CUPS WITH FEMALE SUPPORTS
3D drawings are available on vuototecnica.net
VACUUM CUPS
Force Volume A B C D E F H Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
01 22 19 * 0.95 2.5 14.5 5.0 11.0 22 4 5.5 19 10
01 34 26 * 2.26 8.0 14.5 5.0 17.0 34 4 5.5 26 12
01 43 28 * 3.62 15.3 20.0 6.5 21.5 43 4 7.0 28 14
01 53 35 * 5.51 30.5 27.0 10.5 30.5 53 6 9.5 35 16
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
FEMALE SUPPORTS
A B C D E F G H Support For vacuum cup Weight Sp B
Item
Ø Ø Ø material item g
00 08 132 14.5 13 G1/8” 8.5 8 12 5.0 17.0 aluminium 01 22 19 3.8
01 34 26
00 08 134 20.0 17 G1/4” 10.0 10 14 7.5 21.5 aluminium 01 43 28 8.3
00 08 141 27.0 22 G1/4” 14.0 10 14 9.5 23.5 aluminium 01 53 35 19.7
Sp B
VACUUM CUPS WITH FEMALE SUPPORT
Force A B C D E F G H Vacuum cup Support Weight
Item
Kg Ø Ø Ø item item g
08 22 19 F * 0.95 14.5 13 G1/8” 22 8 12 19 31 01 22 19 00 08 132 6.5
08 34 26 F * 2.26 14.5 13 G1/8” 34 8 12 26 38 01 34 26 00 08 132 9.5
08 43 28 F * 3.62 20.0 17 G1/4” 43 10 14 28 42 01 43 28 00 08 134 17.3
08 53 35 F * 5.51 27.0 22 G1/4” 53 10 14 35 49 01 53 35 00 08 141 37.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.56
REINFORCED BELLOWS VACUUM CUPS WITH SUPPORTS
VACUUM CUP
Force Volume A B C D G H M Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø Ø mm
01 75 42 * 11.93 89.4 59 54 45 78 22.5 42 56 22.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B D E H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 126 45 M12 54 3 10 aluminium 01 75 42 45.5
00 08 465 45 G1/4” 54 3 10 aluminium 01 75 42 41.5
00 08 193 45 G3/8” 54 3 10 aluminium 01 75 42 41.5
00 08 143 45 G1/2” 54 3 10 aluminium 01 75 42 41.5
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.57
REINFORCED BELLOWS VACUUM CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
VACUUM CUPS
Force Volume A B C D G H M Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø Ø mm
01 110 58 * 23.70 281.9 75 70 61 110 33 58 74 33
01 150 74 * 45.00 726.1 112 107 98 150 49 74 103 49
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
SUPPORTS
A B C D E N H Support For vacuum cup Weight
Item
Ø Ø Ø Ø material item g
00 08 162 61 G1/2” G1/8” 70 3 23 10 aluminium 01 110 58 78.9
00 08 163 98 G1/2” G1/8” 107 3 35 10 aluminium 01 150 74 211.8
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.58
BELLOWS VACUUM CUPS FOR GLASS WITH SUPPORTS
This range of cups has been designed for vertically gripping stocked
glass sheets. By laying the cup on the glass surface and opening the
vacuum, the sheet will place itself orthogonally to the floor perfectly
adhering to the cup internal face. The glass sheet can then be
VACUUM CUPS
Force Volume A B C D G H M N Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø Ø Ø mm
01 150 55 * 45.00 471.6 78 70 58 150 33 55 120 125 33
01 210 60 * 86.50 1220.6 138 130 118 210 38 61 180 185 38
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber
SUPPORTS
A B C D E H Support For vacuum cup Weight
Item
Ø Ø Ø Ø material item g
00 08 280 35 G1/2” -- 70 12.5 22.5 aluminium 01 150 55 120
00 08 281 65 G1/2” -- 130 12.5 23.5 aluminium 01 210 60 465
00 08 286 35 --- 8 70 12.5 22.5 aluminium 01 150 55 125
00 08 287 65 --- 8 130 12.5 23.5 aluminium 01 210 60 470
Specifically designed vacuum cups for tripping and handling particularly heavy boxes and
cardboard packaging in general.
Their thick, sturdy lip absorbs tears and sudden accelerations, typical of robotised
movements. The double bellows enables improved adaptability to the gripping surface,
3D drawings are available on vuototecnica.net
even if not perfectly perpendicular to the axis of the vacuum cup, and can recover evident
unevenness of the loads to be lifted.
The supports, all made of anodised aluminium, are equipped with a male or female central
threaded pin to allow suctioning and clamping to the automation. The vacuum cups can
be fitted on them without the aid of adhesives.
To replace, simply request the single vacuum cup indicated in the table in the desired
compound.
1
VACUUM CUPS
Force Volume A B C D E F H L Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
01 35 27 * 2.26 7.3 20 7.5 34 37 11.5 6.2 27 15.5 13
01 52 40 * 5.31 25.2 27 11.5 52 55 16.0 8.2 39 23.0 20
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Sp B
MALE SUPPORTS
A B C D E F G H I L Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 394 20 17 G1/8” 11 6.0 8 7.2 21.2 M5 8 aluminium 01 35 27 6.2
00 08 395 27 20 G1/8” 15 7.5 8 9.2 24.7 M5 8 aluminium 01 52 40 13.2
00 08 366 20 17 G1/4” 11 6.0 8 7.2 21.2 M8 11 aluminium 01 35 27 6.2
00 08 364 27 20 G1/4” 15 7.5 8 9.2 24.7 M8 11 aluminium 01 52 40 13.2
Sp B
Sp B
FEMALE SUPPORTS
A B C D E F G H Support For vacuum cup Weight
Item
Ø Ø Ø material item g
00 08 396 20 17 G1/8” 11 14 8 7.2 21.2 aluminium 01 35 27 9.7
00 08 397 27 20 G1/8” 15 14 8 9.2 23.2 aluminium 01 52 40 20.0
00 08 392 20 17 G1/4” 11 14 10 7.2 21.2 aluminium 01 35 27 7.8
00 08 393 27 20 G1/4” 15 14 10 9.2 23.2 aluminium 01 52 40 18.1
Sp B
1
VACUUM CUPS
Force Volume A B C D E F H L Bellows stroke
Item
Kg cm3 Ø Ø Ø Ø mm
08 75 43 SR * 11.19 74.3 43.0 G1/4” 75.5 80.5 17.5 13.7 50 32.5 28
08 110 73 SR * 24.17 250.6 63.5 G3/8” 113.4 119.0 25.5 19.4 75 49.5 40
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
MALE SUPPORTS
B C D E F G H I L Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 373 8 G1/4” G1/4” 2 10 10 22 M8 11 aluminium 08 75 43 SR 4.1
00 08 372 8 G3/8” G1/4” 2 13 10 25 M8 11 aluminium 08 75 43 SR 7.4
00 08 376 8 G3/8” G3/8” 3 13 15.5 31.5 M8 11 aluminium 08 110 73 SR 14.1
00 08 375 8 G1/2” G3/8” 3 13 15.5 31.5 M8 11 aluminium 08 110 73 SR 15.5
Sp B
FEMALE SUPPORTS
B C D E F G H I L M Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 374 22 G3/8” G1/4” 1.5 14 10.0 25.5 M8 10 11 aluminium 08 75 43 SR 12.0
00 08 377 23 G1/2” G3/8” 3.0 17 15.5 35.5 M8 13 11 aluminium 08 110 73 SR 17.8
Sp B
Hex. 20
VACUUM CUPS WITH ONE BELLOWS WITH WITH VULCANISED FEMALE SUPPORT
Force Volume D E F G H Bellows stroke Support Weight
Item
Kg cm3 Ø mm material g
08 40 30 * 3.14 16.2 40 35 17 18 52 12 aluminium 32.4
08 50 30 * 4.90 27.9 50 37 17 20 54 13 aluminium 40.9
08 60 30 * 7.06 46.8 60 39 17 21 56 14 aluminium 53.6
08 85 30 * 14.08 107.2 85 50 17 31 67 21 aluminium 122.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 20
VACUUM CUPS WITH ONE BELLOWS WITH WITH VULCANISED MALE SUPPORT
Force D E F G H Support Weight
Item
Kg Ø material g
08 40 30 M * 3.14 40 35 13.5 18 56.5 aluminium 29.1
08 50 30 M * 4.90 50 37 13.5 20 58.5 aluminium 39.0
08 60 30 M * 7.06 60 39 13.5 21 60.5 aluminium 51.2
08 85 30 M * 14.08 85 50 13.5 31 71.5 aluminium 115.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.64
VACUUM CUPS WITH TWO BELLOWS WITH VULCANISED SUPPORT
1
Hex. 20
Hex. 20
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.66
SPECIAL VACUUM CUPS WITH SUPPORTS
The cups shown on this page and on the next have been
designed to solve many of the gripping and handling
problems we have encountered in over thirty years of
activity. They differ from all the other cups for the variety of
Hex. 8 1
Hex. 8
Force Volume Support Support Weight Vacuum cup wit upport Weight
Vacuum cup item
Kg mm3 item material g item g
01 07 13 * 0.10 19 00 08 236 brass 3 08 07 13 * 3.6
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 8
Hex. 8
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 08 07 * 0.13 31 00 08 237 brass 3 08 08 07 * 3.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12 Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 11 08 * 0.24 95 00 08 238 brass 7 08 11 08 * 7.6
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.67
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 12 Hex. 12
3D drawings are available on vuototecnica.net
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 14 09 * 0.38 220 00 08 239 brass 8.0 08 14 09 * 8.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12 Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 14 09 * 0.38 220 00 08 240 brass 7.0 08 14 09 F * 7.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12 Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 14 10 * 0.38 301 00 08 03 brass 9.0 08 14 10 * 9.4
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Hex. 12 Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 14 10 * 0.38 301 00 08 04 brass 8.1 08 14 10 F * 8.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.68
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 12
Hex. 12
Hex. 14
Hex. 14
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 14 15 * 0.38 270 00 08 64 brass 13.9 08 14 15 F * 14.4
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 14 32 * 0.38 397 00 08 03 brass 9.0 08 14 32 * 10.9
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.69
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 12
Hex. 12
3D drawings are available on vuototecnica.net
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
1 01 14 32 * 0.38 397 00 08 04 brass 8.1 08 14 32 F * 10.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 15 04 * 0.44 250 00 08 241 brass 1.5 08 15 04 * 1.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 15 15 * 0.03 14 00 08 05 brass 10.4 08 15 15 * 11.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.70
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 17
Hex. 17
Hex. 8 Hex. 8
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 17 12 * 0.60 213 00 08 06 brass 2.6 08 17 12 * 3.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 17 12 * 0.60 213 00 08 03 brass 9.0 08 17 13 * 9.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.71
SPECIAL VACUUM CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
Hex. 12 Hex. 12
1 Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 18 12 * 0.63 459 00 08 67 brass 11.4 08 18 12 * 12.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Hex. 14 Hex. 14
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 18 12 * 0.63 459 00 08 64 brass 13.9 08 18 12 F * 14.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Hex. 20
Hex. 20
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 19 31 * 0.70 5 532 00 08 09 aluminium 18.1 08 19 31 * 20.9
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.72
SPECIAL VACUUM CUPS WITH SUPPORTS
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 06 S 0.78 1068 00 08 243 brass 6.0 08 20 06 * 6.3
Compound: S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 08 * 0.78 804 00 08 60 brass 5.6 08 20 08 * 6.4
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Hex. 8
Hex. 8
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 11 S 0.78 784 00 08 245 brass 2.7 08 20 11 * 3.7
Compound: S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.73
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 12
Hex. 12
3D drawings are available on vuototecnica.net
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 12 * 0.78 314 00 08 146 brass 9.8 08 20 12 * 10.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
1
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 12 * 0.78 314 00 08 155 brass 9.1 08 20 12 F * 10.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 14 N 0.78 589 00 08 146 brass 9.8 08 20 14 * 11.3
Compound: N= orange colour natural rubber
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 14 N 0.78 589 00 08 155 brass 9.1 08 20 14 F * 10.6
Compound: N= orange colour natural rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.74
SPECIAL VACUUM CUPS WITH SUPPORTS
Force Volume Support Support Weight Vacuum cup with support Weight 1
Vacuum cup item
Kg mm3 item material g item g
01 20 15 * 0.78 599 00 08 146 brass 9.8 08 20 15 * 11.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 20 15 * 0.78 599 00 08 155 brass 9.1 08 20 15 F * 10.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 20 24 * 0.78 1.9 00 08 03 brass 9.0 08 20 24 * 10.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.75
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 12
Hex. 12
3D drawings are available on vuototecnica.net
1 Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 20 24 * 0.78 1.9 00 08 04 brass 8.1 08 20 24 F * 9.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 22 06 * 0.95 681 00 08 246 brass 5.0 08 22 06 * 5.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 22 24 * 0.95 7 1.3 00 08 10 aluminium 11.0 08 22 24 * 13.6
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.76
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 22 99 * 0.95 7 1.7 00 08 10 aluminium 11.0 08 22 99 * 13.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 25 08 * 1.23 1.1 00 08 60 brass 5.6 08 25 08 * 7.4
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.77
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 12 Hex. 12
3D drawings are available on vuototecnica.net
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 25 12 * 0.11 125 00 08 82 brass 11.2 08 25 12 * 12.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
1 Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 25 14 N 1.23 1.1 00 08 101 brass 10.8 08 25 14 * 12.6
Compound: N= green colour natural rubber
Hex. 12
Hex. 12
Hex. 12
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 25 28 * 1.23 3.4 00 08 04 brass 8.1 08 25 28 F * 9.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 26 10 * 1.33 1.1 00 08 60 brass 5.6 08 26 10 * 6.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.79
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 17
Hex. 17
3D drawings are available on vuototecnica.net
1
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 27 24 * 1.43 2.2 00 08 15 aluminium 12.3 08 27 24 * 15.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force A Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 30 24 * 1.76 3.0 2.2 00 08 15 aluminium 12.3 08 30 24 * 15.2
01 30 24 L * 1.76 1.5 1.8 00 08 15 aluminium 12.3 08 30 24 L * 15.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm3 item material g item g
01 31 12 S 1.89 991 00 08 249 brass 1.8 08 31 12 S 3.4
Compound: S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.80
SPECIAL VACUUM CUPS WITH SUPPORTS
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 32 30 * 2.00 11.4 00 08 250 aluminium 8.6 08 32 30 * 14.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 32 36 * 2.00 3.4 00 08 19 brass 22.7 08 32 36 * 27.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.81
SPECIAL VACUUM CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
1 01 35 12 * 2.40 2.9 00 08 244 brass 5.9 08 35 12 * 8.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 40 14 * 3.14 4.8 00 08 247 brass 8.4 08 40 14 * 12.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 40 18 * 3.14 8.2 00 08 81 aluminium 8.8 08 40 18 * 15.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.82
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 17
Hex. 17
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 40 25 * 3.14 3.4 00 08 127 aluminium 11.5 08 40 24 * 21.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Hex. 20
Hex. 20
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 40 70 * 3.14 6.3 00 08 09 aluminium 18.1 08 40 70 * 32.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.83
SPECIAL VACUUM CUPS WITH SUPPORTS
Hex. 17
Hex. 17
3D drawings are available on vuototecnica.net
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 44 30 * 3.80 6.7 00 08 127 aluminium 11.5 08 44 30 * 22.8
1 * Complete the code indicating the compound: N= natural para rubber; NG= yellow rubber
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 48 18 * 4.52 11.6 00 08 81 aluminium 8.8 08 48 18 * 17.5
* Complete the code indicating the compound: N= natural para rubber; S= silicone
Hex. 17 Hex. 17
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 50 20 * 4.90 7.0 00 08 24 aluminium 10.3 08 50 20 * 20.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.84
SPECIAL VACUUM CUPS WITH SUPPORTS
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 54 18 * 5.72 11.4 00 08 248 aluminium 5.8 08 54 18 * 16.4
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg cm3 item material g item g
01 65 28 * 8.20 21.0 00 08 24 aluminium 10.3 08 65 28 * 26.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; NG= yellow rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.85
SPECIAL BELLOWS CUPS WITH SUPPORTS
These bellows cups crumple up when in contact with surface to be gripped and in
presence of a vacuum, thus creating a quick lifting movement independently from the
automation. This rapid movement prevents the load beneath from remaining stuck to
the lifted one. Thanks to their great flexibility, they can also be used to compensate
3D drawings are available on vuototecnica.net
1
Hex. 8
Hex. 8
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 06 50 * 0.07 5 135 00 08 06 AVP 2.6 08 06 50 * 3.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 8
Hex. 8
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 08 50 * 0.12 5 155 00 08 06 AVP 2.6 08 08 50 * 3.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 8
Hex. 8
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 11 50 * 0.23 6 178 00 08 06 AVP 2.6 08 11 50 * 3.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.86
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 8
Hex. 8
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 11 16 * 0.23 6 319 00 08 03 brass 9.0 08 11 17 * 9.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 11 16 * 0.23 6 319 00 08 04 brass 8.1 08 11 17 F * 8.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.87
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 12
Hex. 12
3D drawings are available on vuototecnica.net
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
1 01 15 23 * 0.44 10 952 00 08 67 brass 11.4 08 15 23 * 12.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 15 23 * 0.44 10 952 00 08 64 brass 13.9 08 15 23 F * 15.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 15 23 * 0.44 10 952 00 08 65 brass 13.7 08 15 24 F * 15.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.88
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 14
Hex. 14
Hex. 8
Hex. 8
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 16 20 * 0.50 7 970 00 08 06 AVP 2.6 08 16 20 * 3.6
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
01 16 20 * 0.50 7 970 00 08 03 brass 9.0 08 16 21 * 10.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.89
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 12
Hex. 12
3D drawings are available on vuototecnica.net
Force Bellows stroke Volume support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm mm3 item material g item g
1 01 16 20 * 0.50 8 970 00 08 04 brass 8.1 08 16 21 F * 9.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 23 * 0.63 11 1.8 00 08 67 brass 11.4 08 18 23 * 12.9
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 23 * 0.63 11 1.8 00 08 64 brass 13.9 08 18 23 F * 15.4
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.90
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 14
Hex. 14
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 23 * 0.63 11 1.8 00 08 66 brass 13.5 08 18 26 F * 15.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 29 * 0.63 15 2.5 00 08 67 brass 11.4 08 18 29 * 13.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.91
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 14
Hex. 14
3D drawings are available on vuototecnica.net
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
1 01 18 29 * 0.63 15 2.5 00 08 64 brass 13.9 08 18 29 F * 15.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 29 * 0.63 15 2.5 00 08 65 brass 13.7 08 18 30 F * 15.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 29 * 0.63 15 2.5 00 08 66 brass 13.5 08 18 31 F * 15.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.92
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 12
Hex. 12
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 35 * 0.63 18 3.1 00 08 64 brass 13.9 08 18 35 F * 16.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 14
Hex. 14
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 35 * 0.63 18 3.1 00 08 65 brass 13.7 08 18 36 F * 16.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.93
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 14
Hex. 14
3D drawings are available on vuototecnica.net
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
1 01 18 35 * 0.63 18 3.1 00 08 66 brass 13.5 08 18 37 F * 15.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 50 * 0.63 5.5 1.1 00 08 07 brass 4.8 08 18 50 * 5.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 50 * 0.63 5.5 1.1 00 08 61 brass 6.5 08 18 51 * 7.2
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 18 50 * 0.63 5.5 1.1 00 08 62 brass 9.4 08 18 52 * 10.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.94
SPECIAL BELLOWS CUPS WITH SUPPORTS
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 19 17 * 0.70 8 1.9 00 08 60 brass 5.6 08 19 18* 6.9
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 20 60 * 0.78 28 5.4 00 08 07 brass 4.8 08 20 60 * 9.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.95
SPECIAL BELLOWS CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 20 60 * 0.78 28 5.4 00 08 61 brass 6.5 08 20 61 * 10.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 20 60 * 0.78 28 5.4 00 08 62 brass 4.4 08 20 62 * 8.6
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.96
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 17
Hex. 17
Vacuum cup with vulcanised support Force Bellows stroke Volume Support Weight
Item Kg mm cm3 material g
08 25 40 * 1.23 9 4.1 steel 13.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 30 50 * 1.76 14 6.5 00 08 18 aluminium 10.3 08 30 50 * 17.9
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.97
SPECIAL BELLOWS CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 30 50 * 1.76 14 6.5 00 08 50 aluminium 8.5 08 30 50 F * 16.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 30 99 * 1.76 14 6.5 00 08 18 aluminium 10.3 08 30 99 * 18.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.98
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 30 99 * 1.76 14 6.5 00 08 50 aluminium 8.5 08 30 99 F * 16.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 30 55 * 1.76 24 10.6 00 08 18 aluminium 10.3 08 30 55 * 23.1
* Complete the code indicating the compound: N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.99
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 17
3D drawings are available on vuototecnica.net
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 30 55 * 1.76 24 10.6 00 08 50 aluminium 8.5 08 30 55 F * 21.3
* Complete the code indicating the compound: N= natural para rubber; S= silicone
Vacuum cup with vulcanised support Force Bellows stroke Volume Support Weight
Item Kg mm cm3 material g
08 32 40 * 2.00 10 6.9 steel 14.0
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.100
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 12
Hex. 12
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 40 50 * 2.40 7 4.3 00 08 18 aluminium 10.3 08 40 50 * 14.9
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 40 50 * 2.40 7 4.3 00 08 50 aluminium 8.5 08 40 50 F * 13.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.101
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 12
3D drawings are available on vuototecnica.net
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 40 80 * 1.76 32 32.4 00 08 05 brass 10.0 08 40 80 * 38.7
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 40 80 * 1.76 32 32.4 00 08 14 brass 9.8 08 40 80 F * 38.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.102
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 42 90 * 3.00 13 34.6 00 08 05 brass 10.0 08 42 90 * 34.5
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 12
Hex. 12
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 42 90 * 3.00 13 34.6 00 08 14 brass 9.8 08 42 90 F * 34.3
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.103
SPECIAL BELLOWS CUPS WITH SUPPORTS
Sp20
3D drawings are available on vuototecnica.net
Sp20
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 50 70 * 4.90 28 32.2 00 08 148 aluminium 14.5 08 50 70 * 36.8
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.104
SPECIAL BELLOWS CUPS WITH SUPPORTS
3D drawings are available on vuototecnica.net
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 50 60 A 6.60 30 92.1 00 08 466 aluminium 56 08 50 60 * 82
Compound: A= oil-resistant rubber
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.104 -1
SPECIAL BELLOWS CUPS WITH SUPPORTS
Hex. 17
Hex. 17
Hex. 17
Hex. 17
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 75 30 * 11.04 24 62.9 00 08 127 aluminium 11.5 08 75 30 * 48.1
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Hex. 17
Hex. 20
Force Bellows stroke Volume Support Support Weight Vacuum cup with support Weight
Vacuum cup item
Kg mm cm3 item material g item g
01 75 31 * 11.04 24 63.1 00 08 09 aluminium 18.1 08 75 31 * 54.7
Compound: S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.105
SUPPORTS FOR VACUUM CUPS
Hex. 7
1
D E F G H Support For vacuum cup Weight
Item
Ø material item g
00 08 01 2.90 3 5 10 18 brass 01 04 10 4.0
01 05 10
01 06 10
00 08 02 4.75 3 5 10 18 brass 01 08 10 4.0
01 09 07
01 11 16
01 12 10
01 14 10
01 14 32
01 15 10
01 16 20
01 17 12
01 18 10
01 20 10
01 20 24
01 22 10
01 25 28
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.106
SUPPORTS FOR VACUUM CUPS
Hex. 12
Hex. 8
Item
D E F G H Support For vacuum cup Weight 1
Ø material item g
00 08 06 5.25 4.5 4 8.5 17 AVP 01 06 50 2.6
01 08 50
01 11 50
01 11 16
01 16 20
01 17 12
Hex. 20
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.107
SUPPORTS FOR VACUUM CUPS
Hex. 17
3D drawings are available on vuototecnica.net
1
Hex. 12
Hex. 17
Hex. 17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.108
SUPPORTS FOR VACUUM CUPS
Hex. 17
1
Hex. 17
Hex. 17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.109
SUPPORTS FOR VACUUM CUPS
Hex. 17
3D drawings are available on vuototecnica.net
Hex. 17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.110
SUPPORTS FOR VACUUM CUPS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.111
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.112
SUPPORTS FOR VACUUM CUPS
Hex. 17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.113
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
Hex. 12
Hex. 14
D E F G H Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 65 6.5 13 M5 7.5 20.5 brass 01 14 15 13.7
01 15 23
01 18 12
01 18 23
01 18 29
01 18 35
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.114
SUPPORTS FOR VACUUM CUPS
Hex. 14
Hex. 12
D E F G H Support For vacuum cup Weight
Item
Ø material item g
1
00 08 67 6.5 5 8 7.5 20.5 brass 01 14 15 11.4
01 15 23
01 18 12
01 18 23
01 18 29
01 18 35
Note: Supplied automatically also with the fixing plate and the perforated
TSP screw when ordering item 00 08 70
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.115
SUPPORTS FOR VACUUM CUPS
Note: Supplied automatically also with the fixing plate and the
TSP screws when ordering the item relative to the support
Hex. 12
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.116
SUPPORTS FOR VACUUM CUPS
Hex. 12
RING NUT
A B C D H Ring nut For support Weight
Item
Ø Ø Ø Ø material item g
00 08 109 G1/4” 2.5 25.5 34 4.5 aluminium 00 08 108 9.8
00 08 111 G3/8” 2.5 25.5 34 4.5 aluminium 00 08 110 8.7
00 08 113 G3/8” 4.0 45.0 69 6.0 aluminium 00 08 112 58.2
SUPPORT
A D E F G H Support For vacuum cup Weight
Item
Ø Ø material item g
00 08 108 G1/4” 35 9 19.5 4.5 33.0 aluminium 01 76 24 21.4
01 90 24
01 110 24
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.117
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.118
SUPPORTS FOR VACUUM CUPS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.119
SUPPORTS FOR VACUUM CUPS
Hex. 17
3D drawings are available on vuototecnica.net
1
Sp13
Sp13
Sp17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.120
SUPPORTS FOR VACUUM CUPS
Sp17
Sp22
Sp22
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.121
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
Hex. 12
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.122
SUPPORTS FOR VACUUM CUPS
Sp20
1
Hex. 12
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.123
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
Hex. 17
1
C E F G H Support For vacuum cup Weight
Item
Ø material item g
00 08 172 M8 8 14 15 37 aluminium 01 40 25 15.2
01 56 30
01 75 30
Hex. 13
C E F G H Support For vacuum cup Weight
Item
Ø material item g
00 08 173 5.5 5 8 7.5 20.5 aluminium 01 15 23 8.7
01 18 23
01 18 29
01 18 35
O-ring
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.124
SUPPORTS FOR VACUUM CUPS
Hex. 8
Hex. 8
D E F G H Support For vacuum cup Weight
Item
Ø material item g
00 08 237 6 5 5 4 14 brass 01 08 07 3.0
Hex. 12
Hex. 12
Hex. 12
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.125
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
Hex. 8
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.126
SUPPORTS FOR VACUUM CUPS
Non-slip
plastic
coating
Non-slip
plastic
coating
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.127
SUPPORTS FOR VACUUM CUPS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.128
SUPPORTS FOR VACUUM CUPS
Sp B
Sp B
Sp B
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.129
GAS - NPT ADAPTERS
threading.
Hex. T
Hex. T
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.130
THREADED GRUB SCREWS WITH CALIBRATED HOLE
ADAPTERS
MF ADAPTER
D d H Support Weight
Item
Ø Ø material g
00 08 130 G1/4” M10 14 steel 4.0
00 08 131 G3/8” M10 14 steel 12.0
00 08 230 G3/8” G1/4” 14 steel 6.0
00 08 254 1/4” NPT M10 14 steel 3.9
00 08 255 3/8” NPT M10 14 steel 11.9
00 08 258 3/8” NPT G1/4” 14 steel 5.9
Hex. 20
Hex. 20
MM AND MF ADAPTER
D d E F G H Adapter Weight
Item
Ø Ø material g
00 08 129 M12 G1/4” 15 14 11 40 brass 58.0
00 08 296 M12 G3/8” 18 -- 10 28 brass 34.0
00 08 297 G1/4” M12 16 -- 11 27 brass 40.0
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
1.131
VACUUM CUP ADAPTERS
3D drawings are available on vuototecnica.net
MF ADAPTER
D d F H SW Weight
Item
Ø Ø g
00 08 215 G3/8” G1/4” 8 14 6 11.5
MF ADAPTER
D d F H SW Weight
Item
Ø Ø g
00 08 216 G3/8” G1/4” 8 11.5 6 6.0
MM ADAPTER
D d E F SW Weight
Item
Ø Ø g
00 08 217 G1/4” G1/4” 15 10 6 16.7
00 08 218 G1/4” M10 x 1.5 15 12 6 10.2
00 08 219 G1/4” M14 x 1.5 15 12 6 16.0
00 08 220 G3/8” G1/4” 14 10 6 18.4
00 08 221 G3/8” M10 x 1.5 14 12 6 16.3
00 08 222 G3/8” M14 x 1.5 14 12 6 22.5
MM ADAPTER
D d E F SW Weight
Item
Ø Ø g
00 08 223 G1/4” G1/4” 11.5 10 6 13.9
00 08 224 G1/4” M10 x 1.5 13.0 12 6 10.1
00 08 225 G1/4” M14 x 1.5 13.0 12 6 15.8
00 08 226 G3/8” G1/4” 10.5 11 6 16.6
00 08 227 G3/8” M10 x 1.5 10.5 13 6 14.2
00 08 228 G3/8” M14 x 1.5 10.5 13 6 20.2
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.132
SELF-LOCKING VACUUM CUPS WITH TRACTION RELEASE
Vacuum
cup
Sp25
Sp25
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.133
SELF-LOCKING VACUUM CUPS WITH TRACTION RELEASE
3D drawings are available on vuototecnica.net
Vacuum
cup
Sp25
Sp25
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.134
BUILT-IN VACUUM CUPS WITH BALL VALVE
O-ring
Sp 30
Sp 17
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.135
BUILT-IN VACUUM CUPS WITH BALL VALVE
Vacuum
cup
Ring nuts
Sp 17
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.136
BUILT-IN VACUUM CUPS WITH BALL VALVE
Vacuum
cup
Ring
nuts
Sp 17
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.137
SPECIAL BUILT-IN VACUUM CUPS WITH BALL VALVE
Their main feature is that they open suction and therefore they
produce a vacuum, only when the load to be handled activates the
sealing ball.
Especially designed for the vacuum operated beds of woodworking
3D drawings are available on vuototecnica.net
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.138
SPECIAL BUILT-IN VACUUM CUPS WITH BALL VALVE
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.139
SPECIAL BUILT-IN VACUUM CUPS WITH BALL VALVE
3D drawings are available on vuototecnica.net
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.140
SPECIAL BUILT-IN VACUUM CUPS WITH BALL VALVE
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.141
SUPPORTS WITH RETRACTABLE STRIKING PIN
the vacuum while retracting and while remaining in its housing and
also by a stainless steel spring while coming out.
These supports are mechanically fixed to the work surface.
The striking pin is made of plastic material, while the support is made
of anodised aluminium.
They are supplied standard with a quick coupling for vacuum
connection.
Glass plate
Work Surface
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.142
ROUND VACUUM CUPS WITH SELF-LOCKING SUPPORT
Vacuum
cup
Gripping surface
O-ring
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.143
RECTANGULAR VACUUM CUPS WITH SELF-LOCKING SUPPORT
Vacuum
cup
Gripping surface
O-ring
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.144
ROUND VACUUM CUPS WITH BALL VALVE
AND SELF-LOCKING SUPPORT
These cups represent a true mobile clamping system. They are
composed of:
- A sturdy anodised aluminium support with a wide surface at the
base limited by a seal whose purpose is to fix it to the bearing
Vacuum
cup
Gripping surface
O-ring
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.145
RECTANGULAR VACUUM CUPS WITH BALL VALVE AND
SELF-LOCKING SUPPORT
These cups represent a true mobile clamping system. They are
composed of:
- A sturdy anodised aluminium support with a wide surface at the
base limited by a seal whose purpose is to fix it to the bearing
3D drawings are available on vuototecnica.net
surface.
- A standard rectangular flat cup which is cold fitted onto
the upper part of the support for gripping the load.
- A ball valve that opens up creating vacuum, only
when activated by the load to be gripped.
- Two quick couplings for vacuum connection.
The detection of vacuum, for gripping and releasing
the support, can be made via three-way vacuum
valves or solenoid valves.
All cups with self-locking support of this and other
ranges with the gripping plane at the same height can
be used simultaneously, even if they are of different types
or have different sizes.
Vacuum
cup
Gripping surface
O-ring
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.146
ROUND VACUUM CUPS WITH BALL VALVE
AND SELF-LOCKING SUPPORT
These cups represent a true mobile clamping system.
They are composed of:
- A sturdy aluminium support with a wide surface at the base limited by a seal whose
purpose is to fix it to the bearing surface.
Vacuum
Non-slip plastic coating cup
Gripping surface
O-ring
- A standard rectangular flat cup which is cold fitted onto the upper part of the
support for gripping the load.
- A ball valve that opens up creating vacuum, only when activated by the load to be
gripped.
- Two quick couplings for vacuum connection.
The gripping plane of these cups is covered with a special non-slip plastic coating,
which is particularly suited for clamping glass and smooth marble.
The detection of vacuum, for gripping and releasing the support, can be made via
three-way vacuum valves or solenoid valves.
All cups with self-locking support of this and other ranges with the gripping plane
at the same height can be used simultaneously, even if they are of different types
or have different sizes.
Note: Available with support for mechanical fixing with code 28, instead of 18.
O-ring
Vacuum
Non-slip plastic coating cup
Gripping surface
O-ring
ROUND VACUUM CUPS WITH BALL VALVE AND HIGH SELF-LOCKING SUPPORT
Force A B C D E F I L M Vacuum cup O-ring Weight
Item
Kg Ø Ø Ø item item Kg
18 110 10/160 MT * 24.0 88 125 51 114 17 30 1 155.5 12 01 110 10 M 00 16 07 2.986
18 150 10/160 MT * 45.0 120 165 68 154 23 30 1 155.5 12 01 150 10 M 00 16 08 5.042
18 250 20/160 MT * 122.6 223 270 121 254 23 33 1 155.5 15 01 250 20 00 18 09 12.634
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; BA= stain-resistant Biond
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.149
RECTANGULAR VACUUM CUPS WITH BALL VALVE AND
HIGH SELF-LOCKING SUPPORT
These cups also represent a true mobile clamping system. They differ from the above
cups for their exceptional height.
They are composed of:
- A sturdy, tall aluminium support with a wide surface at the base limited by a seal whose
3D drawings are available on vuototecnica.net
O-ring
ROUND VACUUM CUPS WITH BALL VALVE AND HIGH SELF-LOCKING SUPPORT
Force A B C D E F G H M N O P Vacuum cup O-ring Weight
Item
Kg item item Kg
18 120 90/160 MT * 24.0 90 120 98 128 17.5 102 12 30 49 51.0 35.0 35.0 01 120 90 00 16 10 3.450
18 150 75/160 MT * 25.0 75 150 83 144 16.5 130 12 30 57 43.5 27.5 27.5 01 150 75 00 16 10 3.262
18 300 80/160 MT * 60.0 80 300 90 310 17.5 284 15 33 140 47.0 31.0 31.0 01 300 80 00 18 10 7.906
18 300 150/160 MT * 113.0 150 300 160 310 17.5 284 15 33 140 83.0 67.0 67.0 01 300 150 00 18 11 13.110
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone; BA= stain-resistant Biond
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.150
ROUND VACUUM CUPS WITH BALL VALVE
AND HIGH SELF-LOCKING SUPPORT, FOR GLASS
Glass machinery manufacturers require increasingly accurate and
safe clamping machines. This has led us to the creation of this series
of cups.
The specially designed shape of this cup guarantees a firm grip.
Vacuum
cup
Gripping surface
O-ring
The other main feature is the utmost precision in the height, whose
nominal size has a tolerance of only five hundredths of millimetre.
They are composed of:
- A sturdy aluminium support with a wide surface at the base limited
by a seal whose purpose is to fix it to the bearing surface.
- A standard rectangular flat cup which is cold-assembled onto the
upper part of the support for gripping the load.
- A ball valve that opens up creating vacuum, only when activated by
the load to be gripped.
- Two quick couplings for vacuum connection.
The detection of vacuum, for gripping and releasing the support from
the bearing surface and for gripping and release of glass can be made
via three-way vacuum valves or solenoid valves.
Vacuum
cup
Gripping surface
O-ring
Vacuum
cup
Gripping surface
O-ring
Release button
VACUUM CUPS WITH BALL VALVE, SELF-LOCKING SUPPORT AND RELEASE BUTTON
Force A B C D G I L Vacuum cup O-ring Weight
Item
Kg Ø Ø Ø item item Kg
21 85 11/90 A 12.0 70 98 42 85 92.5 1 75 08 85 11 A 00 16 06 1.090
Compound: A = oil-resistant rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.153
ROUND VACUUM CUPS WITH BALL VALVE,
SELF-LOCKING SUPPORT AND RELEASE BUTTON, FOR GLASS
3D drawings are available on vuototecnica.net
Vacuum
cup
Gripping surface
O-ring
Release button
VACUUM CUPS WITH BALL VALVE, SELF-LOCKING SUPPORT AND RELEASE BUTTON
Force A B C D G I L M Vacuum cup O-ring Weight
Item
Kg Ø Ø Ø item item Kg
21 150 11/90 A 42.7 129 165 73 150 92.5 1 75 15 08 150 11 A 00 16 08 3.938
Compound: A = oil-resistant rubber
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.154
ROUND VACUUM CUPS WITH BALL VALVE,
SELF-LOCKING SUPPORT AND RELEASE BUTTON
These cups represent a true mobile clamping system.
They are composed of:
- A sturdy anodised aluminium support with a wide surface at the base limited
by a seal whose purpose is to fix it to the bearing surface.
Vacuum
cup
Gripping surface
VACUUM CUPS WITH BALL VALVE, SELF-LOCKING SUPPORT AND RELEASE BUTTON
Force A B C D E G H L M Vacuum cup O-ring Weight
Item
Kg Ø Ø Ø item item Kg
21 110 10 * 24 88 125 58 114 17 56.0 54.5 50.0 10 01 110 10 M 00 16 07 1.148
21 150 10 * 45 120 165 76 154 23 57.5 54.5 49.5 28 01 150 10 M 00 16 08 2.042
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.155
RECTANGULAR VACUUM CUPS WITH BALL VALVE,
SELF-LOCKING SUPPORT AND RELEASE BUTTON
These cups represent a true mobile clamping system.
They are composed of:
- A sturdy anodised aluminium support with a wide surface at the base
limited by a seal whose purpose is to fix it to the bearing surface.
3D drawings are available on vuototecnica.net
- A standard rectangular flat cup which is cold fitted onto the upper part of
the support for gripping the load.
- A ball valve that opens up creating vacuum, only when activated by the
load to be gripped.
- A release button that allows placing the support even with the vacuum
inserted.
- Two quick couplings for vacuum connection.
The detection of vacuum for gripping and releasing the support from the
bearing surface and gripping and releasing the load can be made via three-
way vacuum valves or solenoid valves.
All cups with self-locking support of this and other ranges with the gripping
plane at the same height can be used simultaneously, even if they are of
different types or have different sizes.
Release button
Vacuum
cup
Gripping surface
O-ring
Item 21 40 75 PP
Vacuum
cup
Gripping surface
VACUUM CUPS WITH BALL VALVE, SELF-LOCKING SUPPORT AND RELEASE BUTTON
Force A B C G H L M N Vacuum cup O-ring Weight
Item
Kg item item Kg
21 40 75 PL * 6.7 41 55 7 56.5 54.5 51 45.5 12 01 40 75 00 05 16 0.460
21 40 75/84 PL * 6.7 41 55 7 86.5 84.0 81 45.5 12 01 40 75 00 05 16 0.702
21 40 75 PP * 6.7 41 55 25 56.5 54.5 51 45.5 45 01 40 75 00 05 16 0.460
21 40 75/ 84 PP * 6.7 41 55 25 86.5 84.0 81 45.5 45 01 40 75 00 05 16 0.702
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.156
RECTANGULAR VACUUM CUPS WITH BALL VALVE,
SELF-LOCKING SUPPORT AND RELEASE BUTTON
Vacuum
cup
Gripping surface
Release O-ring
button
VACUUM CUPS WITH BALL VALVE, SELF-LOCKING SUPPORT AND RELEASE BUTTON
Force A B C D F G H L M N O P Q T Vacuum cup O-ring Weight
Item
Kg item item Kg
21 120 90 * 24 90 120 56 102 17.5 57.0 54.5 50 98 128 70 24 25 49 01 120 90 00 16 10 1.320
21 150 75 * 25 75 120 48 130 16.5 57.0 54.5 50 83 144 55 25 32 57 01 150 75 00 16 10 1.236
21 150 75/84 * 25 75 150 48 130 16.5 86.5 84.0 80 83 144 55 25 32 57 01 150 75 00 16 10 1.924
* Complete the code indicating the compound: A= oil-resistant rubber; N= natural para rubber; S= silicone
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.157
VACUUM CUPS BASED ON BERNOULLI’S THEOREM
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.158
VACUUM CUPS BASED ON BERNOULLI’S THEOREM
Max Transverse Operating Consumption Level Weight Fitting Spare rubber pad
Item force force pressure of air of noise included spacer
g g bar Nl/s dB(A) g item item
BEC 20 220 145 5 2.3 66 21 00 BEC 13 00 BEC 10
Note: BEC vacuum cups must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
For Ø 4 mm ext. hose
Max Transverse Operating Consumption Level Weight Fitting Spare rubber pad
Item force force pressure of air of noise included spacer
g g bar Nl/s dB(A) g item item
BEC 30 380 250 5 2.5 72 31 00 BEC 13 00 BEC 10
Note: BEC vacuum cups must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.159
VACUUM CUPS BASED ON BERNOULLI’S THEOREM
3D drawings are available on vuototecnica.net
Max Transverse Operating Consumption Level Weight Fitting Spare rubber pad
Item force force pressure of air of noise included spacer
g g bar Nl/s dB(A) g item item
BEC 40 680 450 5 3.0 74 51 00 BEC 14 00 BEC 09
Note: BEC vacuum cups must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
Max Transverse Operating Consumption Level Weight Fitting Spare rubber pad
Item force force pressure of air of noise included spacer
g g bar Nl/s dB(A) g item item
BEC 60 900 600 5 4.4 75 121 00 BEC 14 00 BEC 09
Note: BEC vacuum cups must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
1.160
VACUUM CUP QUESTIONNAIRE Company
7) Which position must the vacuum cups have with respect to the lifting force?
Horizontal vacuum cups, vertical force Horizontal vacuum cups, horizontal force
%
1.161
VACUUM CUP QUESTIONNAIRE
1
8) What is the temperature of the object to be lifted?
10) At which height above sea level is the vacuum cup handler to be installed?
Manufacturer Country
Manufacturer Code
We can perform free tests for gripping and handling on samples of products supplied by you. Alternatively, you can request samples of
vacuum cups to perform your own tests.
16) Contact
1.162
VACUUM CUP HOLDERS
VERSION 20 80 05 L
Sp13 Sp10
Sp13 Sp13
VERSION 20 80 05
VERSION 20 80 05 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
d E F L Weight
Item
Ø Ø g
20 80 05 M5 10 M10 x 0.75 73.5 20
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
For Ø 3 ext. hose
Stroke 10 Stroke 10
Sp13 Sp13
VERSION 20 80 05 SR VERSION 20 80 05 RR
d E F L Weight
Item
Ø Ø g
20 80 05 SR M5 10 M10 x 0.75 56 14
20 80 05 RR M5 10 M10 x 0.75 63 16
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.01
MINI VACUUM CUP HOLDERS
series.
They are composed of:
- A brass stem for fastening the cup
- A threaded sleeve equipped with nuts, for mounting the
vacuum up holder on the automation
- A spring to cushion the impact of the cup and to, at the same
time, keep pressure with the load to be lifted
- A quick coupling for connection with the suction hose
Vacuum
cup
2
Support
VERSION 20 . . 30 L
For Ø 4 int. hose
Support
Sp17
VERSION 20 . . 30
VERSION 20 . . 30 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force d D E F L For vacuum cup Support included Weight
Item
Kg Ø Ø Ø item item g
20 04 30 0.03 2.90 4.0 21.0 M12 x 1.25 109.0 01 04 10 00 08 01 74
20 05 30 0.05 2.90 5.0 21.5 M12 x 1.25 109.5 01 05 10 00 08 01 74
20 06 30 0.07 2.90 6.0 21.5 M12 x 1.25 109.5 01 06 10 00 08 01 74
20 08 30 0.12 4.75 8.0 21.5 M12 x 1.25 109.5 01 08 10 00 08 02 74
20 09 30 0.15 4.75 9.0 20.5 M12 x 1.25 108.5 01 09 07 00 08 02 74
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.02
MINI VACUUM CUP HOLDERS
VERSION 20 . . . . L
For Ø 4 int. hose
Sp17
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø Ø Ø item g
20 10 30 0.19 7.0 5.5 10.0 11.0 M12 x 1.25 99.0 01 10 10 70.0
20 12 30 0.28 7.0 5.5 12.0 11.0 M12 x 1.25 99.0 01 12 10 70.6
20 14 15 0.38 7.5 6.5 14.0 15.0 M12 x 1.25 103.0 01 14 15 70.5
20 14 30 0.38 7.0 5.5 14.0 10.0 M12 x 1.25 98.0 01 14 10 70.4
20 15 30 0.44 7.0 5.5 15.0 12.0 M12 x 1.25 100.0 01 15 10 70.7
20 17 30 0.60 7.0 5.5 17.0 11.0 M12 x 1.25 99.0 01 17 12 70.7
20 18 12 0.63 7.5 6.5 18.0 10.0 M12 x 1.25 98.0 01 18 12 70.8
20 18 30 0.63 7.0 5.5 18.0 12.0 M12 x 1.25 100.0 01 18 10 70.7
20 20 30 0.78 7.0 5.5 20.0 12.0 M12 x 1.25 100.0 01 20 10 70.8
20 22 30 0.95 7.0 5.5 22.0 13.0 M12 x 1.25 101.0 01 22 10 71.2
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.03
MINI VACUUM CUP HOLDERS
3D drawings are available on vuototecnica.net
Vacuum
2 cup
VERSION 20 . . 15 L
For Ø 4 int. hose
Sp17
VERSION 20 . . 15
VERSION 20 . . 15 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø Ø Ø item g
20 25 15 1.23 10 7.5 25 16 M12 x 1.25 104 01 25 15 76.0
20 30 15 1.76 10 7.5 30 17 M12 x 1.25 105 01 30 15 76.7
20 35 15 2.40 10 12.0 35 16 M12 x 1.25 104 01 35 15 76.6
20 40 15 3.14 10 12.0 40 18 M12 x 1.25 106 01 40 15 77.1
20 45 15 3.98 10 12.0 45 23 M12 x 1.25 111 01 45 15 80.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.04
MINI VACUUM CUP HOLDERS
Screw
VERSION 20 . . 30 L
For Ø 4 int. hose
Vacuum
cup Stroke 25.5 Sp19 Sp10
Sp17
Screw
VERSION 20 . . 30
VERSION 20 . . 30 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force D E F L For vacuum cup Screw included Weight
Item
Kg Ø Ø item item g
20 25 30 1.23 25.0 8 M12 x 1.25 96 01 25 10 00 20 12 75.2
20 30 30 1.76 30.0 8 M12 x 1.25 96 01 30 10 00 20 12 75.9
20 35 30 2.40 35.0 8 M12 x 1.25 96 01 35 10 00 20 12 76.4
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.05
MINI VACUUM CUP HOLDERS
3D drawings are available on vuototecnica.net
2
Vacuum
cup
VERSION 20 . . 24 L
For Ø 4 int. hose
Sp17
VERSION 20 . . 24
VERSION 20 . . 24 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force D E F L For vacuum cup Weight
Item
Kg Ø Ø item g
20 27 24 1.43 27.0 24 M12 x 1.25 112 01 27 24 76.8
20 30 24 1.76 30.0 24 M12 x 1.25 112 01 30 24 76.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.06
MINI VACUUM CUP HOLDERS
Screw
VERSION 20 . . 30 L
For Ø 4 int. hose
Vacuum
cup
Stroke 25.5 Sp19 Sp10
Sp17
Screw
VERSION 20 . . 30
VERSION 20 . . 30 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force D E F L For vacuum cup Screw included Weight
Item
Kg Ø Ø item item g
20 45 30 3.98 45 18 M12 x 1.25 106 01 45 10 00 20 13 80.7
20 60 30 7.06 60 22 M12 x 1.25 110 01 60 10 00 20 13 88.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.07
MINI VACUUM CUP HOLDERS
3D drawings are available on vuototecnica.net
Vacuum
cup
2
Screw
VERSION 20 . . . . L
For Ø 4 int. hose
Vacuum
cup
Stroke 25.5 Sp19 Sp10
Sp17
Screw
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force D E F L For vacuum cup Screw included Weight
Item
Kg Ø Ø item item g
20 50 20 4.90 50 20 M12 x 1.25 108 01 50 20 00 20 14 82.0
20 65 28 8.20 65 28 M12 x 1.25 116 01 65 28 00 20 14 89.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.08
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
VERSION 20 . . . . L
For Ø 4 int. hose
Sp17
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø Ø Ø item g
20 06 50 0.07 7 5.5 6 15 M12 x 1.25 103 01 06 50 70.4
20 08 50 0.12 7 5.5 8 15 M12 x 1.25 103 01 08 50 70.5
20 11 16 0.23 7 5.5 11 20 M12 x 1.25 108 01 11 16 70.7
20 11 50 0.23 7 5.5 11 15 M12 x 1.25 103 01 11 50 70.6
20 16 30 0.50 7 5.5 16 20 M12 x 1.25 108 01 16 20 71.0
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.09
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
3D drawings are available on vuototecnica.net
2 Vacuum
cup
VERSION 20 . . . . L
For Ø 4 int. hose
Sp17
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø item g
20 15 23 0.44 7.5 6.5 15 23 M12 x 1.25 111 01 15 23 71.3
20 18 23 0.63 7.5 6.5 18 23 M12 x 1.25 111 01 18 23 71.5
20 18 29 0.63 7.5 6.5 18 29 M12 x 1.25 117 01 18 29 71.8
20 18 35 0.63 7.5 6.5 18 35 M12 x 1.25 123 01 18 35 72.3
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.10
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum Support
cup
VERSION 20 . . . . L
For Ø 4 int. hose
Support Sp17
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Support included Weight
Item
Kg Ø Ø Ø item item g
20 18 50 0.63 9 12 18 21.5 M12 x 1.25 109.5 01 18 50 00 08 07 82.7
20 20 62 0.78 9 12 20 56.5 M12 x 1.25 144.5 01 20 60 00 08 07 86.2
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.11
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
3D drawings are available on vuototecnica.net
Vacuum
cup
Screw
VERSION 20 19 17 L
For Ø 4 int. hose
Vacuum Sp17
cup
VERSION 20 19 17
VERSION 20 19 17 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force D E F L For vacuum cup Screw included Weight
Item
Kg Ø Ø item item g
20 19 17 0.70 19 17 M12 x 1.25 105 01 19 17 VERSION00
2020. .12. . T 75.3
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.12
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
VERSION 20 . . . . L
For Ø 4 int. hose
Vacuum
Stroke 25.5 Sp19 Sp10
cup
Sp17
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø Ø Ø item g
20 20 23 0.78 5 8.5 20 23 M12 x 1.25 111 01 20 23 73.8
20 22 19 0.95 5 8.5 22 19 M12 x 1.25 107 01 22 19 74.7
20 34 26 2.26 5 8.5 34 26 M12 x 1.25 114 01 34 26 77.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.13
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
3D drawings are available on vuototecnica.net
2
Vacuum
cup
VERSION 20 25 35 L
For Ø 4 int. hose
Sp17
VERSION 20 25 35
VERSION 20 25 35 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force D E F L For vacuum cup Weight
Item
Kg Ø item g
20 25 35 1.23 25 24 M12 x 1.25 112 01 25 35 79
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.14
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
VERSION 20 . . . . L
Vacuum
cup Stroke 25.5 Sp19 Sp10
Sp17
VERSION 20 . . . .
VERSION 20 . . . . T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø Ø Ø item g
20 30 32 1.76 7.5 10 30 32 M12 x 1.25 120 01 30 32 79.6
20 40 42 3.14 7.5 10 40 42 M12 x 1.25 130 01 40 42 85.6
20 43 28 3.62 7.5 10 43 28 M12 x 1.25 116 01 43 28 83.0
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.15
MINI VACUUM CUP HOLDERS FOR BELLOWS CUPS
3D drawings are available on vuototecnica.net
2 Vacuum
cup
VERSION 20 . . 50 L
For Ø 4 int. hose
Sp17
VERSION 20 . . 50
VERSION 20 . . 50 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force C d D E F L For vacuum cup Weight
Item
Kg Ø Ø Ø item g
20 30 50 1.76 10 9.5 30 38 M12 x 1.25 126 01 30 50 81.6
20 40 50 3.14 10 9.5 40 23 M12 x 1.25 111 01 40 50 78.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.16
MINI VACUUM CUP HOLDERS WITH MALE AND FEMALE THREADED CONNECTORS
Sp17
VERSION 20 . . . . VERSION 20 . . .. T 2
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
d D E F L Weight
Item
Ø Ø Ø g
20 06 35 M5 7.0 3.5 M12 x 1.25 91.5 74
20 07 35 M8 12.0 9 M12 x 1.25 97 76
20 10 38 G1/8” 14.0 9 M12 x 1.25 97 78
20 10 48 G1/4” 16.5 9 M12 x 1.25 97 78
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
For Ø 4 int. hose
Sp17
VERSION 20 10 . . M
VERSION 20 10 . . M T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
D E F L Weight
Item
Ø Ø g
20 10 38 M G1/8” 8 M12 x 1.25 96 78
20 10 48 M G1/4” 10 M12 x 1.25 98 76
20 10 58 M G3/8” 10 M12 x 1.25 98 76
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.17
MINI VACUUM CUP HOLDERS WITH FEMALE THREADED CONNECTORS
Sp19
Stroke 25.5
3D drawings are available on vuototecnica.net
VERSION 20 80 25
Sp10
For Ø 4 int. hose
VERSION 20 80 25 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
d D E F L Weight
Item
Ø Ø Ø g
2 20 80 25 G1/8” 15 15 M12 x 1.25 83.5
. 82
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
For a further bulk and weight reduction, as well as to meet the requirements of discharge automations for
plastic moulding press manufacturers, these cup holders are made with a built-in spring and an anodised
aluminium cup fixing stem. Also these cup holders allow for the installation of cups with male threaded
support only. The particular shape of the brass drive bush for fastening the cup holder to the automation
prevents any rotation of the stem and, therefore, of the cup.
The vacuum connection is radial.
VERSION 20 80 . .
Sp10
VERSION 20 80 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
B C d D F L Weight
Item
stroke Ø Ø Ø g
20 80 15 22 15 G1/8” 15 M10 x 0.75 72 26
20 80 20 32 20 G1/8” 15 M15 x 1.00 87 42
Note: To order chrome-plated iron, add the letters FC to the item.
To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.18
MINI VACUUM CUP HOLDERS WITH COMPACT STROKE
The shorter stroke and their particular shape allow for further
bulk and weight reduction of these cup holders, with respect to
the previous mini vacuum cup holders.
The components are practically the same, only the vacuum
VERSION 20 07 13
Cap 00 20 69
2
Vacuum
cup
Fitting 00 20 61
Sp17 Sp19
Vacuum
cup
VERSION 20 . . 13 DR
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.19
MINI VACUUM CUP HOLDERS WITH COMPACT STROKE
3D drawings are available on vuototecnica.net
VERSION 20 . . 10
Vacuum Cap 00 20 69
cup
2
Fitting 00 20 61
VERSION 20 . . 10 DR
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.20
MINI VACUUM CUP HOLDERS WITH COMPACT STROKE
Cap 00 20 69
2
Vacuum
cup
Fitting 00 20 61
VERSION 20 . . 10 DR
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.21
MINI VACUUM CUP HOLDERS WITH BUILT-IN BUSH
The reduced size and the particular shape of these cup holders
allow them to be directly assembled to the vacuum manifold,
saving time and eliminating pipes and fittings.
The hexagonal threaded bush for cup holder assembly with the
3D drawings are available on vuototecnica.net
2
VERSION 20 . . 11
Vacuum
cup
Stroke 16.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.22
MINI VACUUM CUP HOLDERS WITH BUILT-IN BUSH
Vacuum
cup
Vacuum
cup
Sp17 Sp20
Stroke 16.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.23
VACUUM CUP HOLDERS WITH BUILT-IN BUSH,
WITH FEMALE THREADED CONNECTOR
3D drawings are available on vuototecnica.net
VERSION 20 . . 11
Sp17 Sp20
Stroke 16.4
2
d D E F L Weight
Item
Ø Ø Ø g
20 08 11 G1/8” 14.0 9 G3/8” 67 74
20 10 11 G1/4” 16.5 9 G3/8” 67 73
VERSION 20 . . 11 M
Sp17 Sp20
Stroke 16.4
d E F L Weight
Item
Ø Ø g
20 08 11 M G1/8” 8 G3/8” 66 75
20 10 11 M G1/4” 10 G3/8” 68 74
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1,130
25.4 453.6 0.4536
2.24
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE
Vacuum 2
cup
VERSION 20 . . 60 L
For Ø 4 int. hose
Vacuum
cup
VERSION 20 . . 60
VERSION 20 . . 60 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force B C D E F L M For vacuum cup Weight
Item
Kg Ø Ø item g
20 12 60 0.28 4.5 8.5 12 11 M12 x 1.25 118 2 01 12 10 78.6
20 15 60 0.44 4.5 8.5 12 12 M12 x 1.25 119 1 01 15 10 78.7
20 18 60 0.63 4.5 8.5 12 12 M12 x 1.25 119 1 01 18 10 78.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.25
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE
3D drawings are available on vuototecnica.net
2 Vacuum
cup
VERSION 20 . . 60 L
For Ø 4 int. hose
Vacuum
VERSION 20 . . 60
cup
VERSION 20 . . 60 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force B C D E F L M For vacuum cup Weight
Item
Kg Ø Ø item g
20 20 60 0.78 5.5 8.5 20 12 M12 x 1.25 119 2 01 20 10 80.8
20 22 60 0.95 5.5 8.5 22 13 M12 x 1.25 120 1 01 22 10 81.2
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.26
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE
VERSION 20 25 60 L
For Ø 4 int. hose
Vacuum
VERSION 20 25 60
cup
VERSION 20 25 60 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force B C D E F L For vacuum cup Weight
Item
Kg Ø Ø item g
20 25 60 1.23 6 11 25 16 M12 x 1.25 123 01 25 15 84
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.27
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE
3D drawings are available on vuototecnica.net
2
Vacuum
cup
VERSION 20 30 60 L
For Ø 4 int. hose
Vacuum VERSION 20 30 60
cup
VERSION 20 30 60 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force B C D E F L For vacuum cup Weight
Item
Kg Ø Ø item g
20 30 60 1.76 7 11 30 17 M12 x 1.25 124 01 30 15 86.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.28
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE
VERSION 20 . . 60 L
For Ø 4 int. hose
Vacuum VERSION 20 . . 60
cup
VERSION 20 . . 60 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force B C D E F L M For vacuum cup Weight
Item
Kg Ø Ø item g
20 35 60 2.40 7 11 35 16 M12 x 1.25 123 2 01 35 15 90.6
20 40 60 3.14 7 11 40 18 M12 x 1.25 125 0 01 40 15 91.1
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.29
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE AND BUILT-IN BUSH
2
VERSION 20 . . 65
Vacuum
cup
Stroke 16.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.30
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE AND BUILT-IN BUSH
VERSION 20 . . 65
Vacuum
cup
Stroke 16.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.31
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE AND BUILT-IN BUSH
3D drawings are available on vuototecnica.net
2
VERSION 20 25 65
Vacuum
cup
Stroke 16.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.32
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE AND BUILT-IN BUSH
Vacuum
cup
Stroke 16.4
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.33
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE AND BUILT-IN BUSH
3D drawings are available on vuototecnica.net
VERSION 20 . . 65
Vacuum
cup
Sp12 Sp20
Stroke 16.4
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.34
MINI VACUUM CUP HOLDERS WITH PLUNGER VALVE WITH NO SPRINGING
VERSION 20 . . 61
Vacuum
cup
Vacuum Sp12
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.35
MINI VACUUM CUP HOLDERS WITH NO SPRINGING
3D drawings are available on vuototecnica.net
VERSION 20 . . 61
Vacuum
cup
Vacuum Sp12
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.36
MINI VACUUM CUP HOLDERS WITH NO SPRINGING
VERSION 20 25 61
Vacuum
cup
Vacuum Sp12
cup
20 25 61 1.23 6 11 25 16 G1/8” 48 01 25 15 26
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.37
MINI VACUUM CUP HOLDERS WITH NO SPRINGING
3D drawings are available on vuototecnica.net
VERSION 20 30 61
Vacuum
cup
Sp12
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.38
MINI VACUUM CUP HOLDERS WITH NO SPRINGING
VERSION 20 . . 61
Vacuum
cup
Sp12
Vacuum
cup
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.39
MINI VACUUM CUP HOLDERS WITH BUILT-IN SHUT-OFF VALVE
VERSION 20 99 35 L
For Ø 4 int. hose
Sp13
VERSION 20 99 35
VERSION 20 99 35 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
A C D E F L Weight
Item
Ø Ø g
20 99 35 17.5 35.5 G1/8” 24 M12 x 1.25 107 84
Minimum trigger flow = 1.5 m3/h Minimum a level of vacuum = -250 mbar
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.40
MINI ANTI-ROTATION VACUUM CUP HOLDERS
The technical features are the same as for the mini vacuum
cup holders, with their distinctive features being their brass
stem with hexagonal section and the steel drive bush with
hexagonal hole. This prevents the stem from rotating on
VERSION 20 95 08 L
For Ø 4 int. hose
Stroke 25.5
VERSION 20 95 08
VERSION 20 95 08 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
A B C D E F L Weight
Item
Ø Ø g
20 95 08 17.5 30 35.5 M8 6 M12 x 1.25 89 58
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.41
MINI ANTI-ROTATION VACUUM CUP HOLDERS
3D drawings are available on vuototecnica.net
VERSION 20 95 28 L
For Ø 4 int. hose
VERSION 20 95 28
VERSION 20 95 28 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
A B C D E F G L Weight
Item
Ø Ø g
20 95 28 17.5 30 35.5 G1/8” 8 M12 x 1.25 5 96 60
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.42
MINI ANTI-ROTATION VACUUM CUP HOLDERS
VERSION 20 95 38 L
For Ø 4 int. hose
VERSION 20 95 38
VERSION 20 95 38 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
A B C D E F L Weight
Item
Ø Ø g
20 95 38 17.5 30 35.5 G1/8” 16 M12 x 1.25 99 68
Note: To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.43
MINI VACUUM CUP HOLDERS WITH MAGNETIC SENSOR
Vacuum
cup
Magnetic sensor
VERSION 20 99 02 L
For Ø 4 int. hose
Magnetic sensor
VERSION 20 99 02
Vacuum
cup VERSION 20 99 02 T
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
Force A D F G H I M For vacuum cup Weight
Item
Kg Ø Ø item g
20 99 02 0.70 17 19 M12 x 1.25 18 20 10 28 01 19 17 163.3
1.23 16 25 M12 x 1.25 18 20 10 28 01 25 15 161.3
20 99 03
1.76 17 35 M12 x 1.25 18 20 10 28 01 30 15 162.0
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L or T fittings, add the letter L or T to the code.
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.44
MINI VACUUM CUP HOLDERS FIX
2
Sp8
Sp12
VERSION 20 70 01 VERSION 20 70 01 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
D E F L Weight
Item
Ø Ø g
20 70 01 M5 6 G1/8” 46 19
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
For Ø 4 int. hose
Sp10
Sp19
VERSION 20 70 05 VERSION 20 70 05 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 4 X 6
D E F L Weight
Item
Ø Ø g
20 70 05 M5 6 M12 x 1.25 46 45
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.45
BASIC VACUUM CUP HOLDERS
2
Vacuum
cup
screw
For Ø 6 int. hose
Sp17
VERSION 02 . . 10 VERSION 02 . . 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Screw included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 25 10 1.23 28 25 23 M20 123 01 25 10 00 20 12 213.2 253.2 280.2
02 30 10 1.76 28 30 23 M20 123 01 30 10 00 20 12 213.9 253.9 280.9
02 35 10 2.40 28 35 23 M20 123 01 35 10 00 20 12 214.4 254.4 281.4
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.46
BASIC VACUUM CUP HOLDERS
Sp17
VERSION 02 . . 15 VERSION 02 . . 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 25 15 1.23 28 25 31 M20 131 01 25 15 216.0 270.0 287.0
02 30 15 1.76 28 30 32 M20 132 01 30 15 216.7 270.7 287.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.47
BASIC VACUUM CUP HOLDERS
Vacuum
2 cup
Sp17
VERSION 02 . . 24 VERSION 02 . . 24 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 27 24 1.43 28 27 39 M20 139 01 27 24 216.8 228.8 287.8
02 30 24 1.76 28 30 39 M20 139 01 30 24 216.9 228.9 287.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.48
BASIC VACUUM CUP HOLDERS
Sp17
VERSION 02 32 36 VERSION 02 32 36 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 32 36 2.00 28 32 51 M20 151 01 32 36 221.1 269.1 289.1
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.49
BASIC VACUUM CUP HOLDERS
Vacuum
cup For Ø 6 int. hose
Sp17
VERSION 02 . . 15 VERSION 02 . . 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 35 15 2.40 28 35 31 M20 131 01 35 15 218.6 266.6 293.6
02 40 15 3.14 28 40 33 M20 133 01 40 15 219.1 267.1 294.1
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.50
BASIC VACUUM CUP HOLDERS
Screw
For Ø 6 int. hose
Screw Sp20
VERSION 02 . . 10 VERSION 02 . . 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Screw included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 45 10 3.98 28 45 33 M20 133 01 45 10 00 20 13 222.7 270.7 336.7
02 60 10 7.06 28 60 37 M20 137 01 60 10 00 20 13 230.9 278.9 344.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.51
BASIC VACUUM CUP HOLDERS
Vacuum
cup
For Ø 6 int. hose
Sp20
VERSION 02 45 15 VERSION 02 45 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 45 15 3.98 28 45 38 M20 138 01 45 15 222.6 272.6 295.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.52
BASIC VACUUM CUP HOLDERS
Screw
For Ø 6 int. hose
Screw Sp20
VERSION 02 . . . . VERSION 02 . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Screw included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 50 20 4.90 28 50 35 M20 135 01 50 20 00 20 14 226.0 277.0 300.0
02 65 28 8.29 28 65 43 M20 143 01 65 28 00 20 14 231.7 282.7 305.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.53
BASIC VACUUM CUP HOLDERS
2 Vacuum
cup
Sp20
VERSION 02 . . . . VERSION 02 . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 50 40 4.90 28 50 41.0 M20 141.0 08 50 40 258.5 288.5 320.5
02 75 40 11.04 28 75 50.0 M20 150.0 08 75 40 277.9 307.9 339.9
02 100 40 19.62 28 100 51.0 M20 151.0 08 100 40 298.3 328.3 360.3
02 100 50 19.62 28 100 55.5 M20 155.5 08 100 50 294.8 324.8 356.8
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.54
BASIC VACUUM CUP HOLDERS
Support
Vacuum
For Ø 6 int. hose
cup
Sp30 Sp17
Sp20
Support
VERSION 02 56 15 VERSION 02 56 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 56 15 6.15 28 56 34 M20 134 01 56 15 00 08 83 305.0 352.6 379.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.55
BASIC VACUUM CUP HOLDERS
Vacuum
cup
Support
Vacuum
cup
For Ø 6 int. hose
Sp30 Sp17
Sp20
Support
VERSION 02 65 15 VERSION 02 65 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 65 15 8.29 28 65 32 M20 132 01 65 15 00 08 32 346.1 384.4 410.4
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.56
BASIC VACUUM CUP HOLDERS
Vacuum
cup
For Ø 6 int. hose
Ring nut
Sp30 Sp17
Sp20
Support
VERSION 02 . . 24 VERSION 02 . . 24 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Ring nut included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
02 76 24 11.33 28 76 49 M20 149 01 76 24 00 08 110 00 08 111 298 338 361
02 90 24 15.89 28 90 49 M20 149 01 90 24 00 08 110 00 08 111 323 363 390
02 110 24 23.74 28 110 49 M20 149 01 110 24 00 08 110 00 08 111 373 413 439
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.57
BASIC VACUUM CUP HOLDERS
Vacuum
cup
Support
Vacuum
cup
For Ø 6 int. hose
Sp30 Sp17
Sp20
Support
VERSION 02 80 20 VERSION 02 80 20 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 80 20 12.56 28 80 35 M20 135 01 80 20 00 08 126 296.4 334.3 361.8
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.58
BASIC VACUUM CUP HOLDERS
Screw
For Ø 6 int. hose
Vacuum
cup
Sp30 Sp17
Screw Sp20
VERSION 02 85 10 VERSION 02 85 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Screw included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 85 10 14.18 28 85 56 M20 156 01 85 10 00 20 13 318.0 347.9 369.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.59
BASIC VACUUM CUP HOLDERS
Vacuum
cup
Support
Vacuum
cup
For Ø 6 int. hose
Sp30 Sp17
Sp20
Support
VERSION 02 85 15 VERSION 02 85 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 85 15 14.18 28 85 32 M20 132 01 85 15 00 08 32 334 371 399
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.60
BASIC VACUUM CUP HOLDERS
Support
Vacuum
cup
For Ø 6 int. hose
Sp30 Sp17
Sp20
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 110 10 23.74 28 114 32 M20 132 01 110 10 00 08 33 456 494 521
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.61
BASIC VACUUM CUP HOLDERS
Vacuum Cap
cup
Cap
For Ø 6 int. hose
Sp30 Sp17
Sp20
Vacuum
cup
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Cap included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 110 15 23.74 28 110 41 M20 141 08 110 15 00 11 06 571 608 636
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.62
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum Sp30
Sp30 Sp17
cup
Sp20
VERSION 02 20 23 VERSION 02 20 23 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 20 23 0.78 28 20 38 M20 138 01 20 23 213.8 256.8 283.8
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.63
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
2
Vacuum
cup
Sp17
VERSION 02 . . . . VERSION 02 . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 22 19 0.95 28 22 34 M20 134 01 22 19 214.7 257.7 284.7
02 34 26 2.26 28 34 41 M20 141 01 34 26 217.7 260.7 287.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.64
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
Sp17
VERSION 02 25 35 VERSION 02 25 35 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 25 35 1.23 28 25 50 M20 150 01 25 35 219 231 290
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.65
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
2
cup
Sp20
VERSION 02 . . . . VERSION 02 . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 30 32 1.76 28 30 47 M20 147 01 30 32 219.6 264.6 294.6
02 40 42 3.14 28 40 57 M20 157 01 40 42 215.6 270.6 300.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.66
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Sp17
VERSION 02 30 . . VERSION 02 30 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 30 50 1.76 28 30 53 M20 153 01 30 50 221.6 258.6 285.6
02 30 99 1.76 28 30 53 M20 153 01 30 99 222.2 259.2 286.2
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.67
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
2 Vacuum
cup
Sp17
VERSION 02 30 55 VERSION 02 30 55 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 30 55 1.76 28 30 70 M20 170 01 30 55 226.8 263.8 290.8
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.68
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Sp20
VERSION 02 . . 30 VERSION 02 . . 30 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 40 30 3.14 28 40 67 M20 167 08 40 30 256.4 296.4 325.4
02 50 30 4.90 28 50 69 M20 169 08 50 30 264.9 304.9 333.9
02 60 30 7.06 28 60 71 M20 171 08 60 30 277.6 317.6 346.6
02 85 30 14.18 28 85 82 M20 182 08 85 30 346.0 386.0 415.0
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.69
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
2
Sp17
VERSION 02 40 50 VERSION 02 40 50 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 40 50 3.14 28 40 38 M20 138 01 40 50 220.6 255.6 282.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.70
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Sp20
VERSION 02 . . . . VERSION 02 . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 40 60 3.14 28 40 84 M20 184 08 40 60 265.6 304.6 334.6
02 50 50 4.90 28 50 87 M20 187 08 50 50 275.6 314.6 344.6
02 60 50 7.06 28 60 91 M20 191 08 60 50 248.4 337.4 367.4
02 85 50 14.18 28 85 110 M20 210 08 85 50 394.0 433.0 463.0
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.71
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
2 Vacuum
cup
Sp20
VERSION 02 43 28 VERSION 02 43 28 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 43 28 3.62 28 43 43 M20 143 01 43 28 225 269 299
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.72
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Sp30 Sp17
Sp20
Vacuum
cup
VERSION 02 50 53 VERSION 02 50 53 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 50 53 4.90 28 50 68 M20 168 01 50 53 247.4 286.4 315.4
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.73
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
Sp20
VERSION 02 52 50 VERSION 02 52 50 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 52 50 5.30 28 52 57 M20 157 01 52 50 248.7 298.7 325.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.74
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
For Ø 6 int. hose
Sp30 Sp17
Sp20
Vacuum
cup
VERSION 02 53 35 VERSION 02 53 35 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 53 35 5.51 28 53 41 M20 141 01 53 35 241.6 279.6 308.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.75
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
2 Vacuum
cup
Sp30 Sp17
Sp17
Vacuum
cup
VERSION 02 . . 30 VERSION 02 . . 30 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 56 30 6.15 28 56 33 M20 133 01 56 30 236.0 243.0 264.0
02 75 30 11.04 28 75 69 M20 169 01 75 30 255.6 262.6 283.6
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.76
BASIC VACUUM CUP HOLDERS FOR BELLOWS CUPS
Support
For Ø 6 int. hose
Sp20
Vacuum
cup
VERSION 02 75 42 VERSION 02 75 42 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 75 42 11.04 28 75 57 M20 157 01 75 42 00 08 126 317.8 355.8 382.8
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.77
BASIC VACUUM CUP HOLDERS WITH MALE AND FEMALE THREADED CONNECTORS
These basic vacuum cup holders also have the same characteristics and offer the same
performance as those previously described. Their distinctive feature is the brass stem
with a threaded male or female end for fixing the cup.
The cups to be assembled onto these vacuum cup holders must be equipped with the
3D drawings are available on vuototecnica.net
VERSION 02 08 . . VERSION 02 08 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 08 28 32 40 28 G1/8” 15 M20 115 207
02 08 65 32 40 65 G1/8” 15 M20 152 243
02 08 95 32 40 95 G1/8” 15 M20 182 272
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
VERSION 02 08 . . M VERSION 02 08 . . M L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 08 28 M 32 40 28 G1/8” 15 M20 123 216
02 08 65 M 32 40 65 G1/8” 15 M20 160 252
02 08 95 M 32 40 95 G1/8” 15 M20 190 282
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.78
BASIC VACUUM CUP HOLDERS WITH MALE AND FEMALE THREADED CONNECTORS
VERSION 02 10 . . VERSION 02 10 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 10 28 32 40 28 G1/4” 20 M20 120 224
02 10 65 32 40 65 G1/4” 20 M20 157 262
02 10 95 32 40 95 G1/4” 20 M20 187 289
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
VERSION 02 10 . . M VERSION 02 10 . . M L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 10 28 M 32 40 28 G1/4” 15 M20 124 225
02 10 65 M 32 40 65 G1/4” 15 M20 161 266
02 10 95 M 32 40 95 G1/4” 15 M20 191 295
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.79
BASIC VACUUM CUP HOLDERS WITH MALE AND FEMALE THREADED CONNECTORS
2
VERSION 02 11 . . VERSION 02 11 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 11 28 32 40 28 M12 20 M20 120 226
02 11 65 32 40 65 M12 20 M20 157 264
02 11 95 32 40 95 M12 20 M20 187 291
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
VERSION 02 11 . . M VERSION 02 11 . . M L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 11 28 M 32 40 28 M12 15 M20 124 223
02 11 65 M 32 40 65 M12 15 M20 161 264
02 11 95 M 32 40 95 M12 15 M20 191 293
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.80
BASIC VACUUM CUP HOLDERS WITH MALE AND FEMALE THREADED CONNECTORS
2
VERSION 02 12 . . VERSION 02 12 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 12 28 32 40 28 G3/8” 25 M20 125 220
02 12 65 32 40 65 G3/8” 25 M20 162 259
02 12 95 32 40 95 G3/8” 25 M20 192 285
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
VERSION 02 12 . . M VERSION 02 12 . . M L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 12 28 M 32 40 28 G3/8” 15 M20 125 237
02 12 65 M 32 40 65 G3/8” 15 M20 162 274
02 12 95 M 32 40 95 G3/8” 15 M20 192 303
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.81
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
Screw Vacuum
cup
For Ø 6 int. hose
Screw
VERSION 03 45 10 VERSION 03 45 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Screw included Weight Weight Weight
Item
Kg Ø Ø item item g g g
03 45 10 3.98 28 45 70 M20 170 01 45 10 00 20 13 344.7 381.7 415.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.82
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
Vacuum
cup Sp22 Sp22 Sp30 Sp17
Screw
Disc
VERSION 03 60 10 VERSION 03 60 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Screw included Disc included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
03 60 10 7.06 28 60 74 M20 172 01 60 10 00 20 13 00 03 22 361.9 399.9 432.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.83
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
2 Vacuum
cup
Disc
Support
For Ø 6 int. hose
Vacuum
cup
Sp22 Sp22 Sp30 Sp17
Support
Disc
VERSION 03 65 15 VERSION 03 65 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Disc included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
03 65 15 8.29 28 65 70 M20 170 01 65 15 00 08 32 00 03 22 459.4 497.4 530.4
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.84
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
Support
Disc
For Ø 6 int. hose
Vacuum
cup
Sp22 Sp22 Sp30 Sp17
Support
Disc
VERSION 03 80 20 VERSION 03 80 20 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Disc included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
03 80 20 12.56 28 80 73 M20 173 01 80 20 00 08 126 00 03 22 432.2 470.2 503.2
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.85
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
2
Vacuum
cup
Screw
Disc
For Ø 6 int. hose
Vacuum
cup
Sp22 Sp22 Sp30 Sp17
Screw
Disc
VERSION 03 85 10 VERSION 03 85 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Disc included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
03 85 10 14.18 28 85 92 M20 192 01 85 10 00 20 13 00 03 22 420.9 462.9 483.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.86
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
Disc Support
For Ø 6 int. hose
Vacuum
cup
Sp22 Sp22 Sp30 Sp17
Support
Disc
VERSION 03 85 15 VERSION 03 85 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Disc included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
03 85 15 14.18 28 85 70 M20 170 01 85 15 00 08 32 00 03 22 477.7 515.7 548.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.87
BASIC VACUUM CUP HOLDERS WITH PLUNGER VALVE
Vacuum
cup
2
Support
Disc
Vacuum
cup
For Ø 6 int. hose
Support
Disc
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force *C D E F L For vacuum cup Support included Disc included Weight Weight Weight
Item
Kg Ø Ø item item item g g g
03 110 10 23.74 28 114 70 M20 170 01 110 10 00 08 33 00 03 22 618.3 549.3 683.3
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.88
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
Vacuum
cup
Screw
Vacuum
cup Sp22 Sp22
Screw
VERSION 03 45 11
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.89
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
3D drawings are available on vuototecnica.net
Vacuum
cup
Disc Screw
Vacuum
cup
Sp22 Sp22
Screw
Disc
VERSION 03 60 11
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.90
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
Disc
Support
Vacuum
cup
Sp22 Sp22
Support
Disc
VERSION 03 65 16
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.91
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
3D drawings are available on vuototecnica.net
2
Vacuum
cup
Support
Disc
Vacuum
cup
Sp22 Sp22
Support
Disc
VERSION 03 80 21
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.92
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
Vacuum
cup
Screw
Disc
Vacuum
cup
Sp22 Sp22
Screw
Disc
VERSION 03 85 11
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.93
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
3D drawings are available on vuototecnica.net
Vacuum
cup
2
Disc Support
Vacuum
cup
Sp22 Sp22
Support
Disc
VERSION 03 85 16
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.94
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
Support
Disc
Vacuum
cup
Sp22 Sp22
Support
Disc
VERSION 03 110 11
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.95
BASIC VACUUM CUP HOLDERS WITH NO SPRINGING
3D drawings are available on vuototecnica.net
Vacuum
cup
2
Sp20
Vacuum
cup
VERSION 03 . . . .
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.96
BASIC VACUUM CUP HOLDERS WITH BUILT-IN SHUT-OFF VALVE
Along with all the other features they share with the other basic
vacuum cup holders, these have a built-in shut-off valve.
The function of the shut-off valve is to automatically close
suction when the cup is not in contact with the surface of the
VERSION 02 99 . . VERSION 02 99 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F L Weight
Item
Ø Ø g
02 99 28 32 40 28 G1/4” 30 M20 130 256
02 99 65 32 40 65 G1/4” 30 M20 167 301
02 99 95 32 40 95 G1/4” 30 M20 197 333
Minimum trigger flow = 4 m3/h Minimum level of vacuum = -250 mbar
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.97
BASIC ARTICULATED VACUUM CUP HOLDERS
Vacuum Support
cup
Vacuum Support
cup
Sp17 Sp10
Sp30
For Ø 6 int. hose
VERSION 02 65 20
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 65 20 8.29 21 37 28 65 M20 52 130 01 65 16 00 02 36 382.4 431.4 461.4
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.98
BASIC ARTICULATED VACUUM CUP HOLDERS
Vacuum
cup
Support
Sp17 Sp10
Sp30
For Ø 6 int. hose
VERSION 02 85 20
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 85 20 14.18 21 37 28 85 M20 52 130 01 85 16 00 02 36 400.7 449.7 479.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.99
BASIC ARTICULATED VACUUM CUP HOLDERS
Vacuum Support
cup
Vacuum
cup
Support
Sp17 Sp10
Sp30
For Ø 6 int. hose
VERSION 02 110 20
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight Weight
Item
Kg Ø Ø item item g g g
02 110 20 23.74 26 37 28 114 M20 52 130 01 110 10 00 02 37 540.3 587.3 614.3
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.100
BASIC ARTICULATED VACUUM CUP HOLDERS
Vacuum
cup
Sp17 Sp10
Sp30
For Ø 6 int. hose
VERSION 02 110 22
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 65 mm C = 95 mm
Force A B *C D F G L For vacuum cup Weight Weight Weight
Item
Kg Ø Ø item g g g
02 110 22 23.74 26 46 28 110 M20 61 139 08 110 40 M8 603 654 683
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 65 mm and 95 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.101
BASIC ANTI-ROTATION VACUUM CUP HOLDERS
VERSION 02 95 . . VERSION 02 95 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D E F G L Weight
Item
Ø Ø g
02 95 28 32 40 28 M12 15 M20 x 1 10 125 180
02 95 65 32 40 65 M12 15 M20 x 1 10 162 225
02 95 95 32 40 95 M12 15 M20 x 1 10 192 246
02 95 28 1/4” 32 40 28 G1/4” 15 M20 x 1 10 125 181
02 95 65 1/4” 32 40 65 G1/4” 15 M20 x 1 10 162 226
02 95 95 1/4” 32 40 95 G1/4” 15 M20 x 1 10 192 247
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.102
BASIC VACUUM CUP HOLDERS FIX
VERSION 02 91 01 VERSION 02 91 01 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
D E F L Weight
Item
Ø Ø g
02 91 01 G1/4” 10 M20 x 1 74 162
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
For Ø 6 int. hose
Sp17
Ring nut KM4
VERSION 02 91 . . VERSION 02 91 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
D E F L Weight
Item
Ø Ø g
02 91 05 G1/4” 10 M20 x 1 84 170
02 91 06 G3/8” 10 M20 x 1 84 174
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
2.103
SPECIAL VACUUM CUP HOLDERS
Vacuum
2 cup
Support
Vacuum
For Ø 6 int. hose
cup
Sp17
VERSION 06 85 10 VERSION 06 85 10 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item g g
06 85 10 14.18 46 39 55 85 M35 x 1.5 50 190 01 85 10 00 08 29 731.9 853.9
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.104
SPECIAL VACUUM CUP HOLDERS
Support
Vacuum
For Ø 6 int. hose
cup
Sp17
VERSION 06 85 15 VERSION 06 85 15 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item g g
06 85 15 14.18 22 39 55 85 M35 x 1.5 50 166 01 85 15 00 08 32 779.7 899.7
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.105
SPECIAL VACUUM CUP HOLDERS
Vacuum
cup
2
Vacuum
For Ø 6 int. hose
cup
Sp17
Ring nut
Ring nut KM7
Support
VERSION 06 90 24 VERSION 06 90 24 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Ring nut included Weight Weight
Item
Kg Ø Ø item item item g g
06 90 24 15.89 29 39 55 90 M35 x 1.5 50 173 01 90 24 00 08 110 00 08 111 852.8 974.8
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.106
SPECIAL VACUUM CUP HOLDERS
Vacuum
cup
Sp17
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Weight Weight
Item
Kg Ø Ø item g g
06 100 40 19.62 31 39 55 100 M35 x 1.5 50 175 08 100 40 736 858
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.107
SPECIAL VACUUM CUP HOLDERS
2 Vacuum
cup
Vacuum
cup
Sp17
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Weight Weight
Item
Kg Ø Ø item g g
06 100 50 19.62 35.5 39 55 100 M35 x 1.5 50 179.5 08 100 50 732 854
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.108
SPECIAL VACUUM CUP HOLDERS
Support
Vacuum
cup
For Ø 6 int. hose
Sp17
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item g g
06 110 10 23.74 22 39 55 114 M35 x 1.5 50 166 01 110 10 00 08 33 912.3 1034.3
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.109
SPECIAL VACUUM CUP HOLDERS
Vacuum
cup
2
Cap
Vacuum
cup
For Ø 6 int. hose
Sp17
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Cap included Weight Weight
Item
Kg Ø Ø item item g g
06 110 15 23.74 31 39 55 110 M35 x 1.5 50 175 08 110 15 00 11 06 980 1100
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.110
SPECIAL VACUUM CUP HOLDERS
Vacuum
cup
Sp17
Ring nut
Ring nut KM7
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Ring nut included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 110 24 23.74 29 39 55 110 M35 x 1.5 50 173 01 110 24 00 08 110 00 08 111 1.07 1.19
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.111
SPECIAL VACUUM CUP HOLDERS
Vacuum
cup
Support
Vacuum
cup
For Ø 6 int. hose
Sp17
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 150 10 45.00 28 39 55 154 M35 x 1.5 50 172 01 150 10 00 08 35 1.32 1.45
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.112
SPECIAL VACUUM CUP HOLDERS
Support
Ring nut
Vacuum
cup
For Ø 6 int. hose
Sp17
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Ring nut included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 150 36 45.00 41 39 55 150 M35 x 1.5 50 185 01 150 36 00 08 112 00 08 113 1.39 1.52
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.113
SPECIAL VACUUM CUP HOLDERS
Vacuum
cup
Vacuum
cup
VERSION 06 . . . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 150 15 45.00 26 40.0 55 150 M35 x 1.5 50 144 08 150 15 1.51 1.64
06 200 10 78.50 28 47.5 55 200 M35 x 1.5 52 146 08 200 10 2.42 2.54
06 250 10 122.60 28 72.5 55 250 M35 x 1.5 52 146 08 250 10 3.68 3.80
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.114
SPECIAL VACUUM CUP HOLDERS
Vacuum Support
cup
VERSION 06 220 10 . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 10 OF 63.6 35 70 55 220 M35 x 1.5 61 153 01 220 10 OF 00 08 37 1.87 1.99
06 220 10 NF 63.6 35 70 55 220 M35 x 1.5 61 153 01 220 10 NF 00 08 37 1.86 1.98
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.115
SPECIAL VACUUM CUP HOLDERS
Vacuum Support
cup
Vacuum
cup
Support
VERSION 06 220 10 A
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 10 A 78.5 20 70 55 220 M35 x 1.5 44 138 01 220 10 A 00 08 37 1.81 1.94
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.116
SPECIAL VACUUM CUP HOLDERS
VERSION 06 . . . 10
VACUUM CUP HOLDERS WITH HOSE-END FITTING FOR PLASTIC HOSE Ø 16 X 18 C = 110 mm
Force A B *C D F G L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 300 10 176.6 31 89 55 300 M35 x 1.5 61 149 08 300 10 5.42 5.56
06 350 10 240.0 31 89 55 350 M35 x 1.5 61 149 08 350 10 7.30 7.43
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.117
SPECIAL VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
Vacuum
cup
Sp19
Support
VERSION 06 75 42 VERSION 06 75 42 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 75 42 11.93 42 45 55 78 M35 x 1.5 50 197 01 75 42 00 08 143 0.76 0.87
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.118
SPECIAL VACUUM CUP HOLDERS FOR BELLOWS CUPS
Cap
Vacuum
For Ø 9 int. hose
cup
Sp19
Cap
Ring nut KM7
VERSION 06 . . . 30 VERSION 06 . . . 30 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Cap included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 110 30 23.74 45 45 55 110 M35 x 1.5 50 200 08 110 30 00 11 44 0.97 1.08
06 150 30 45.00 60 45 55 150 M35 x 1.5 50 215 08 150 30 00 11 44 1.09 1.20
06 180 30 63.50 70 45 55 180 M35 x 1.5 50 225 08 180 30 00 11 44 1.45 1.56
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.119
SPECIAL VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum Support
cup
Cap
For Ø 9 int. hose
Support
Sp19
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Cap included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 110 58 23.74 58 45 55 110 M35 x 1.5 50 213 01 110 58 00 08 162 00 11 44 0.93 1.04
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.120
SPECIAL VACUUM CUP HOLDERS FOR BELLOWS CUPS
Cap
For Ø 9 int. hose
Support
Sp19
Vacuum
cup
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Support included Cap included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 150 74 45.00 74 45 55 150 M35 x 1.5 50 229 01 150 74 00 08 163 00 11 44 1.34 1.45
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.121
SPECIAL VACUUM CUP HOLDERS FOR BELLOWS CUPS
Vacuum
cup
Cap
For Ø 9 int. hose
Sp19
Vacuum
cup
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F G L For vacuum cup Cap included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 250 30 122.60 100 45 55 250 M35 x 1.5 50 255 08 250 30 00 18 33 2.20 2.31
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.122
SPECIAL VACUUM CUP HOLDERS WITH MALE AND FEMALE THREADED CONNECTORS
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
*C F L Weight
Item
Ø Kg
06 12 55 M 55 M35 x 1.5 160 0.63
06 12 110 M 110 M35 x 1.5 215 0.77
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
Sp17
VERSION 06 12 . . VERSION 06 12 . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
*C F L Weight
Item
Ø Kg
06 12 55 55 M35 x 1.5 164 0.62
06 12 110 110 M35 x 1.5 219 0.75
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.123
SPECIAL VACUUM CUP HOLDERS WITH MALE THREADED CONNECTORS
VERSION 06 . . . . M VERSION 06 . . . . M L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE
A *C F L M Int. hose Weight
Item
Ø Ø Kg
06 11 55 M M12 55 M35 x 1.5 159 G1/4” 6 0.63
06 11 110 M M12 110 M35 x 1.5 214 G1/4” 6 0.77
06 13 55 M G1/2” 55 M35 x 1.5 159 G3/8” 9 0.63
06 13 110 M G1/2” 110 M35 x 1.5 214 G3/8” 9 0.77
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
VERSION 06 . . . . M
A *C F L Weight
Item
Ø Kg
06 14 55 M M16 55 M35 x 1.5 129 0.52
06 14 110 M M16 110 M35 x 1.5 184 0.65
06 15 55 M M12 55 M35 x 1.5 129 0.52
06 15 110 M M12 110 M35 x 1.5 184 0.65
Note: The vacuum cup holder is not equipped with an axial vacuum passage
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.124
SPECIAL VACUUM CUP HOLDERS WITH PLUNGER VALVE
They share the same mechanical features at the special vacuum cup
holders. The addition of a plunger valve solidly connected to a conical
spear valve, which activates suction, and therefore creates vacuum,
only when the cup comes into contact with the load to be lifted.
Vacuum
cup
2
Screw
Disc
For Ø 6 int. hose
Vacuum
cup
Sp22 Sp17
Screw
Ring nut KM7
Disc
VERSION 06 85 20 VERSION 06 85 20 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Screw included Disc included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.125
SPECIAL VACUUM CUP HOLDERS WITH PLUNGER VALVE
Vacuum
cup
2
Disc Support
For Ø 6 int. hose
Vacuum
cup
Sp22 Sp17
VERSION 06 85 22 VERSION 06 85 22 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Disc included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 85 22 14.18 65 55 85 M35 x 1.5 209 01 85 15 00 08 32 00 03 22 0.89 1.01
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.126
SPECIAL VACUUM CUP HOLDERS WITH PLUNGER VALVE
Disc Support
Vacuum
For Ø 6 int. hose
cup
Sp22 Sp17
Support
Disc
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Disc included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 110 20 23.74 65 55 114 M35 x 1.5 209 01 110 10 00 08 33 00 03 22 1.02 1.14
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.127
SPECIAL VACUUM CUP HOLDERS WITH PLUNGER VALVE
Vacuum
cup
Cap
Vacuum
cup
For Ø 6 int. hose
Sp22 Sp17
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Cap included Weight Weight
Item
Kg Ø item item Kg Kg
06 110 22 23.74 74 55 110 M35 x 1.5 218 08 110 15 00 11 06 1.48 1.56
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.128
SPECIAL VACUUM CUP HOLDERS WITH PLUNGER VALVE
Disc Support
Vacuum
cup
For Ø 6 int. hose
Sp22 Sp17
Support
Disc
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Disc included Weight Weight
Item
Kg Ø Ø item item item Kg Kg
06 150 20 45.00 71 55 154 M35 x 1.5 215 01 150 10 00 08 35 00 03 22 1.43 1.52
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.129
SPECIAL VACUUM CUP HOLDERS WITH PUSH VALVE
They share the same technical and mechanical features at the special
vacuum cup holders. Their distinctive feature is the push valve on the
cup support, which activates suction, and therefore creates vacuum,
only when the cup is in contact with the load to be lifted.
3D drawings are available on vuototecnica.net
Vacuum
cup
Item 19 02 10
Vacuum
cup
Sp17
VERSION 06 . . . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 150 22 45.0 26 40.0 55 150 M35 x 1.5 144 08 150 15 1.68 1.80
06 200 20 78.5 28 47.5 55 200 M35 x 1.5 146 08 200 10 2.58 2.71
06 250 20 122.6 28 72.5 55 250 M35 x 1.5 146 08 250 10 3.84 3.97
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.130
SPECIAL VACUUM CUP HOLDERS WITH PUSH VALVE
Item 19 03 10
Vacuum
cup
Ring
nut KM7
For Ø 9 int. hose
Sp17
VERSION 06 . . . 20
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 300 20 176.6 31 89 55 300 M35 x 1.5 149 08 300 10 5.56 5.69
06 350 20 240.0 31 89 55 350 M35 x 1.5 149 08 350 10 7.42 7.55
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.131
SPECIAL VACUUM CUP HOLDERS WITH BUILT-IN SHUT-OFF VALVE
Along with all the other features they share with the other special cup
holders, these also have a built-in shut-off valve.
The purpose of the shut-off valve is to automatically close suction
when the cup is not in contact with the surface of the load to be
3D drawings are available on vuototecnica.net
Sp17
VERSION 06 . . . . . VERSION 06 . . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8
A B C D F L Weight
Item
Ø Ø Kg
06 99 55 16 11 55 G3/8” M35 x 1.5 160 0.63
06 99 110 16 11 110 G3/8” M35 x 1.5 215 0.77
Minimum trigger flow = 4 m3/h Minimum level of vacuum = -250 mbar
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.132
SPECIAL ARTICULATED VACUUM CUP HOLDERS
Vacuum Support
cup
Vacuum
cup
Support
Sp12
Sp19
VERSION 06 110 12
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 110 12 23.74 26 77 55 114 M35 x 1.5 195 01 110 10 00 06 14 1.15 1.27
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.133
SPECIAL ARTICULATED VACUUM CUP HOLDERS
2
Vacuum
cup
Vacuum
cup
Sp12
Sp19
For Ø 6 int. hose
VERSION 06 110 17
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 110 17 23.74 26 86 55 110 M35 x 1.5 204 08 110 15 1.22 1.34
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.134
SPECIAL ARTICULATED VACUUM CUP HOLDERS
Vacuum
cup
Support
Sp12
Sp19
Ring nut KM7
For Ø 6 int. hose
VERSION 06 150 12
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 150 12 45.00 30 83 55 154 M35 x 1.5 201 01 150 10 00 06 15 1.56 1.69
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.135
SPECIAL ARTICULATED VACUUM CUP HOLDERS
Vacuum
cup
2
Vacuum
cup
Sp12
Sp19
Ring nut KM7
For Ø 9 int. hose
VERSION 06 . . . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 150 17 45.00 40.0 86 55 150 M35 x 1.5 204 08 150 15 1.73 1.85
06 200 12 78.50 47.5 88 55 200 M35 x 1.5 206 08 200 10 2.63 2.75
06 250 12 122.60 72.5 88 55 250 M35 x 1.5 206 08 250 10 3.89 4.02
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.136
SPECIAL ARTICULATED
VACUUM CUP HOLDERS
The actual springing stroke is:
- For height C= 55 mm 37 mm
- For height C= 110 mm 84 mm
Support
Vacuum
cup
Sp12
Sp19
Ring nut KM7
For Ø 9 int. hose
VERSION 06 220 12 . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 12 OF 63.60 70 97 55 220 M35 x 1.5 215 01 220 10 OF 00 08 37 2.08 2.21
06 220 12 NF 63.60 70 97 55 220 M35 x 1.5 215 01 220 10 NF 00 08 37 2.07 2.20
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.137
SPECIAL ARTICULATED
VACUUM CUP HOLDERS
The actual springing stroke is:
- For height C= 55 mm 37 mm
- For height C= 110 mm 84 mm
3D drawings are available on vuototecnica.net
Vacuum Support
cup
Support
Vacuum
cup Sp12
Sp19
Ring nut KM7
For Ø 9 int. hose
VERSION 06 220 12 A
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 12 A 78.50 70 80 55 220 M35 x 1.5 198 01 220 10 A 00 08 37 2.03 2.16
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.138
SPECIAL ARTICULATED
VACUUM CUP HOLDERS
The actual springing stroke is:
- For height C= 55 mm 37 mm
- For height C= 110 mm 84 mm
Vacuum
cup
Sp19
Sp30
VERSION 06 . . . 12
VACUUM CUP HOLDERS WITH HOSE-END FITTING FOR PLASTIC HOSE Ø 16 X 18 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 300 12 176.6 89 115 55 300 M35 x 1.5 233 08 300 10 6.09 6.22
06 350 12 240.0 89 115 55 350 M35 x 1.5 233 08 350 10 7.95 8.08
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.139
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITHOUT GS ARTICULATED JOINT
Vacuum Support
cup
Vacuum
cup
Sp22
se
. ho
int Ring nut KM7
6
rØ
Fo
VERSION 06 110 32
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 110 32 23.74 33 42.5 55 114 M35 x 1.5 160.5 01 110 10 00 06 62 1.15 1.27
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.140
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITHOUT GS ARTICULATED JOINT
Support 2
Vacuum
cup
Sp22 e
os
t.h
in Ring nut KM7
6
rØ
Fo
Support
VERSION 06 150 32
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 150 32 45.00 39 48.5 55 154 M35 x 1.5 166.5 01 150 10 00 06 49 1.63 1.76
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.141
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH COMPACT STROKE
Marble and glass sheets are usually handled with cups that take them
from a horizontal plane and place them vertically or vice-versa.
These special cup holders with compact stroke have been designed to
minimise the lever forces between the cup and the automation fixing bush
3D drawings are available on vuototecnica.net
during the rotation of the sheets, as well as their sliding on the cups.
They share all the technical features of the other previously described
special cup holders but their overall dimensions are reduced to minimum
by housing the articulated joint in the cup support, thus reducing the steel
stem and the spring stroke length and modifying the brass bush, in order
to allow it to be screwed directly onto the automation.
Moreover, a special non-slip plastic coating fixed onto the cup support
prevents the lifted load from slipping.
The actual springing stroke is:
- For height C= 29 mm 13 mm
Vacuum
cup
Support
2
Swivel L fitting
G1 / 8 “
Non-slip
coating For Ø 6 ext. hose
Vacuum
cup
Support
Sp30
VERSION 06 110 42
Non-slip
coating
Support
2
Swivel L fitting
G1 / 8 “
Vacuum
cup
Support
Sp30
VERSION 06 127 42
Vacuum
cup
Support
Swivel L fitting
G1 / 8 “
Non-slip
For Ø 6 ext. hose
coating
Vacuum
cup
Support
Sp30
VERSION 06 150 42
Hex. 16
Sp22 Sp22
VERSION 06 . . . . . VERSION 06 . . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE
A B C D d E F L M N O RL RM Weight
Item
Ø Ø Ø Ø g
06 55 80 13 34 55 G1/4” 6 G1/4” M25 x 1.5 142 21.0 32.0 18.5 G1/4” G1/4” 318
06 55 81 15 40 55 G3/8” 9 G3/8” M25 x 1.5 150 21.5 35.5 22.0 G3/8” G3/8” 330
06 55 82 15 34 55 G3/8” 6 G1/4” M25 x 1.5 144 21.0 32.0 18.5 G1/4” G1/4” 320
06 110 80 13 34 110 G1/4” 6 G1/4” M25 x 1.5 197 21.0 32.0 18.5 G1/4” G1/4” 386
06 110 81 15 40 110 G3/8” 9 G3/8” M25 x 1.5 205 21.5 35.5 22.0 G3/8” G3/8” 398
06 110 82 15 34 110 G3/8” 6 G1/4” M25 x 1.5 199 21.0 32.0 18.5 G1/4” G1/4” 388
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.145
SPECIAL ANTI-ROTATION VACUUM CUP HOLDERS WITH MALE THREADED
CONNECTOR
The actual springing stroke is:
- For height C= 55 mm 37 mm
- For height C= 110 mm 84 mm
3D drawings are available on vuototecnica.net
Hex. 16
Sp22 Sp22
VERSION 06 . . . . . VERSION 06 . . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE
A B C D d E F L M N O RL RM Weight
Item
Ø Ø Ø Ø g
06 55 90 15 34 55 G1/4” 6 G1/4” M25 x 1.5 144 21.0 32.0 18.5 G1/4” G1/4” 314
06 55 91 15 34 55 G3/8” 6 G1/4” M25 x 1.5 144 21.0 32.0 18.5 G1/4” G1/4” 320
06 55 92 15 40 55 G3/8” 9 G3/8” M25 x 1.5 150 21.5 35.5 22.0 G3/8” G3/8” 330
06 55 93 15 40 55 G1/2” 9 G3/8” M25 x 1.5 150 21.5 35.5 22.0 G3/8” G3/8” 332
06 55 94 15 34 55 M12 6 G1/4” M25 x 1.5 144 21.0 32.0 18.5 G1/4” G1/4” 318
06 55 95 15 40 55 M12 9 G3/8” M25 x 1.5 150 21.5 35.5 22.0 G3/8” G3/8” 328
06 55 96 15 40 55 M16 9 G3/8” M25 x 1.5 150 21.5 35.5 22.0 G3/8” G3/8” 330
06 110 90 15 34 110 G1/4” 6 G1/4” M25 x 1.5 199 21.0 32.0 18.5 G1/4” G1/4” 374
06 110 91 15 34 110 G3/8” 6 G1/4” M25 x 1.5 199 21.0 32.0 18.5 G1/4” G1/4” 380
06 110 92 15 40 110 G3/8” 9 G3/8” M25 x 1.5 205 21.5 35.5 22.0 G3/8” G3/8” 390
06 110 93 15 40 110 G1/2” 9 G3/8” M25 x 1.5 205 21.5 35.5 22.0 G3/8” G3/8” 392
06 110 94 15 34 110 M12 6 G1/4” M25 x 1.5 199 21.0 32.0 18.5 G1/4” G1/4” 378
06 110 95 15 40 110 M12 9 G3/8” M25 x 1.5 205 21.5 35.5 22.0 G3/8” G3/8” 388
06 110 96 15 40 110 M16 6 G3/8” M25 x 1.5 205 21.5 35.5 22.0 G3/8” G3/8” 390
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.146
SPECIAL ANTI-ROTATION VACUUM CUP HOLDERS WITH SPHERICAL SWIVEL
SUPPORT
In addition the characteristics of the previously described
special anti-rotation vacuum cups, these cup holders are
provided with a nylon spherical swivel support which allows to
place and keep the cup in the desired place.
Sp22
Hex. 16
Sp22
VERSION 06 . . . . . VERSION 06 . . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE
A B C D d E L M N O RL RM Weight
Item
Ø Ø Ø g
06 55 100 13 34 55 G1/4” 6 G1/4” 142 21.0 32.0 18.5 G1/4” G1/4” 338
06 55 101 15 40 55 G3/8” 9 G3/8” 150 21.5 35.5 22.0 G3/8” G3/8” 350
06 55 102 15 34 55 G3/8” 6 G1/4” 144 21.0 32.0 18.5 G1/4” G1/4” 340
06 110 100 13 34 110 G1/4” 6 G1/4” 197 21.0 32.0 18.5 G1/4” G1/4” 406
06 110 101 15 40 110 G3/8” 9 G3/8” 205 21.5 35.5 22.0 G3/8” G3/8” 418
06 110 102 15 34 110 G3/8” 6 G1/4” 199 21.0 32.0 18.5 G1/4” G1/4” 408
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.147
SPECIAL ANTI-ROTATION VACUUM CUP HOLDERS WITH SPHERICAL SWIVEL
SUPPORT
The actual springing stroke is:
- For height C= 55 mm 37 mm
- For height C= 110 mm 84 mm
3D drawings are available on vuototecnica.net
Sp22
Hex. 16
Sp22
VERSION 06 . . . . . VERSION 06 . . . . . L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE
A B C D d E L M N O RL RM Weight
Item
Ø Ø Ø g
06 55 110 15 34 55 G1/4” 6 G1/4” 144 21.0 32.0 18.5 G1/4” G1/4” 334
06 55 111 15 34 55 G3/8” 6 G1/4” 144 21.0 32.0 18.5 G1/4” G1/4” 340
06 55 112 15 40 55 G3/8” 9 G3/8” 150 21.5 35.5 22.0 G3/8” G3/8” 350
06 55 113 15 40 55 G1/2” 9 G3/8” 150 21.5 35.5 22.0 G3/8” G3/8” 352
06 55 114 15 34 55 M12 6 G1/4” 144 21.0 32.0 18.5 G1/4” G1/4” 338
06 55 115 15 40 55 M12 9 G3/8” 150 21.5 35.5 22.0 G3/8” G3/8” 348
06 55 116 15 40 55 M16 9 G3/8” 150 21.5 35.5 22.0 G3/8” G3/8” 350
06 110 110 15 34 110 G1/4” 6 G1/4” 199 21.0 32.0 18.5 G1/4” G1/4” 394
06 110 111 15 34 110 G3/8” 6 G1/4” 199 21.0 32.0 18.5 G1/4” G1/4” 400
06 110 112 15 40 110 G3/8” 9 G3/8” 205 21.5 35.5 22.0 G3/8” G3/8” 410
06 110 113 15 40 110 G1/2” 9 G3/8” 205 21.5 35.5 22.0 G3/8” G3/8” 412
06 110 114 15 34 110 M12 6 G1/4” 199 21.0 32.0 18.5 G1/4” G1/4” 398
06 110 115 15 40 110 M12 9 G3/8” 205 21.5 35.5 22.0 G3/8” G3/8” 408
06 110 116 15 40 110 M16 9 G3/8” 205 21.5 35.5 22.0 G3/8” G3/8” 410
Note: To order vacuum cup holders with L fittings, add the letter L to the code.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.148
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
cup
2
Support
For Ø 6 int. hose
Vacuum
cup
Sp17
Support
VERSION 06 85 13 VERSION 06 85 13 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 85 13 14.18 46 55 85 M35 x 1.5 245 01 85 10 00 08 29 0.87 0.99
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.149
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
cup
Support
For Ø 6 int. hose
Vacuum
cup
Sp17
Support
Ring nut KM7
VERSION 06 85 17 VERSION 06 85 17 L
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 85 17 14.18 22 55 85 M35 x 1.5 221 01 85 15 00 08 32 0.90 1.04
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.150
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Support
Vacuum
For Ø 6 int. hose
cup
Sp17
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 110 13 23.74 22 55 114 M35 x 1.5 221 01 110 10 00 08 33 1.05 1.18
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.151
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
2 cup
cap
For Ø 6 int. hose
Vacuum
cup
Sp17
Cap
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Cap included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 110 16 23.74 31 55 110 M35 x 1.5 230 08 110 15 00 11 06 1.12 1.25
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.152
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Support
Vacuum
cup
For Ø 6 int. hose
Sp17
Support
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 150 13 45.00 28 55 154 M35 x 1.5 227 01 150 10 00 08 35 1.46 1.58
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
To order vacuum cup holders with L fittings, add the letter L to the code.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.153
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
2 Vacuum
cup
Vacuum
cup
Ring
nut KM7
For Ø 9 int. hose
VERSION 06 . . . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 150 18 45.0 26 40.0 55 150 M35 x 1.5 199 08 150 15 1.65 1.79
06 200 13 78.5 28 47.5 55 200 M35 x 1.5 201 08 200 10 2.55 2.69
06 250 13 122.6 28 72.5 55 250 M35 x 1.5 201 08 250 10 3.82 3.96
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.154
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum Support
cup
Ring
nut KM7
For Ø 9 int. hose
VERSION 06 220 13 . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 13 OF 63.6 35 70 55 220 M35 x 1.5 208 01 220 10 OF 00 08 37 2.01 2.15
06 220 13 NF 63.6 35 70 55 220 M35 x 1.5 208 01 220 10 NF 00 08 37 2.00 2.14
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.155
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum Support
cup
Vacuum Support
cup
VERSION 06 220 13 A
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 13 A 78.5 20 70 55 220 M35 x 1.5 193 01 220 10 A 00 08 37 1.96 2.09
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.156
SPECIAL VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
cup
Ring
nut KM7
For Ø 16 int. hose
VERSION 06 . . . 13
VACUUM CUP HOLDERS WITH HOSE-END FITTING FOR PLASTIC HOSE Ø 16 X 18 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 300 13 176.6 31 89 55 300 M35 x 1.5 204 08 300 10 5.57 5.70
06 350 13 240.0 31 89 55 350 M35 x 1.5 204 08 350 10 7.43 7.57
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.157
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
2 cup
Vacuum
cup
Support
Sp12
Sp19
Ring nut KM7
For Ø 6 int. hose
VERSION 06 110 14
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 110 14 23.74 26 77 55 114 M35 x 1.5 250 01 110 10 00 06 14 1.29 1.39
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.158
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
cup
Sp12
Sp19
Ring nut KM7
For Ø 6 int. hose
VERSION 06 110 18
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 110 18 23.74 26 86 55 110 M35 x 1.5 259 08 110 15 1.36 1.46
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.159
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum Support
cup
Vacuum
cup
Support
Sp12
Sp19
Ring nut KM7
For Ø 6 int. hose
VERSION 06 150 14
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 6 X 8 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 150 14 45.00 30 83 55 154 M35 x 1.5 256 01 150 10 00 06 15 1.71 1.81
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.160
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
cup
Sp12
Sp19
Ring nut KM7
For Ø 9 int. hose
VERSION 06 . . . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D E F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 150 19 45.00 40.0 86 55 150 50 M35 x 1.5 259 08 150 15 1.86 1.97
06 200 14 78.50 47.5 88 55 200 52 M35 x 1.5 261 08 200 10 2.77 2.87
06 250 14 122.60 72.5 88 55 250 52 M35 x 1.5 261 08 250 10 4.03 4.14
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.161
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum Support
cup
Support
Vacuum
cup
Sp12
Sp19
VERSION 06 220 14 . . .
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 14 OF 63.6 70 97 55 220 M35 x 1.5 270 01 220 10 OF 00 08 37 2.22 2.32
06 220 14 NF 63.6 70 97 55 220 M35 x 1.5 270 01 220 10 NF 00 08 37 2.21 2.31
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.162
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Support
Vacuum
cup
Sp12
Sp19
VERSION 06 220 14 A
VACUUM CUP HOLDERS WITH STRAIGHT QUICK COUPLER FOR PLASTIC HOSE Ø 9 X 12 C = 110 mm
Force A B *C D F L For vacuum cup Support included Weight Weight
Item
Kg Ø Ø item item Kg Kg
06 220 14 A 78.5 70 80 55 220 M35 x 1.5 253 01 220 10 A 00 08 37 2.17 2.27
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.163
SPECIAL ARTICULATED VACUUM CUP HOLDERS WITH DOUBLE SPRINGING
Vacuum
cup
Vacuum
cup
Sp19
Sp30
VERSION 06 . . . 14
VACUUM CUP HOLDERS WITH HOSE-END FITTING FOR PLASTIC HOSE Ø 16 X 18 C = 110 mm
Force A B *C D F L For vacuum cup Weight Weight
Item
Kg Ø Ø item Kg Kg
06 300 14 176.6 89 115 55 300 M35 x 1.5 288 08 300 10 6.24 6.63
06 350 14 240.0 89 115 55 350 M35 x 1.5 288 08 350 10 8.10 8.22
Note: The vacuum cups are not integral parts of the cup holders and, therefore, must be ordered separately.
* Also available with height C of 110 mm
Note: The force of the vacuum cups indicated in the table represents 1/3 of the value of the theoretical force calculated at a level of vacuum of -75 KPa and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.164
SPHERICAL ARTICULATED JOINTS
2
A B C D E F L Weight
Item
Ø Ø g
GSM8 15 5 25 M8 4.5 M8 49.5 55
Sp12 Sp19
Hex. 30
A B C D E F L Weight
Item
Ø Ø g
GSM12 21 6.5 34.5 M12 8.5 M12 70.5 220
Sp19 Sp30
Sp41
A B C D E F L Weight
Item
Ø Ø g
GSM16 26.5 8 53 M16 10 M16 97.5 670
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.165
BALL JOINT COUPLINGS WITH AXIAL VACUUM CONNECTION
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
2.166
POSITIONABLE BALL JOINT COUPLINGS WITH AXIAL VACUUM CONNECTION
GSV 1/8” 40 20 -- G1/8” G1/8” 11.5 10 24.5 51.5 20 7 aluminium 18.24 77.6
GSV 1/4” 45 25 -- G1/4” G1/4” 14.5 12 28.5 60.5 25 7 aluminium 23.54 126.7
GSV 3/8” 50 30 -- G3/8” G3/8” 14.0 12 34.5 69.5 25 10 aluminium 33.91 171.2
GSVF 1/8” 40 20 15 G1/8” G1/8” 11.5 10 24.5 51.5 20 7 aluminium 18.24 80.4
GSVF 1/4” 45 25 20 G1/4” G1/4” 14.5 12 28.5 60.5 25 7 aluminium 23.54 129.2
GSVF 3/8” 50 30 21 G3/8” G3/8” 17.0 12 34.5 69.5 25 10 aluminium 33.91 167.6
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
2.167
VACUUM CUP HOLDER FIXING SUPPORTS
Hex. 16
Item Item
Item
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.168
VACUUM CUP HOLDER FIXING SUPPORTS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.169
VACUUM CUP HOLDER FIXING SUPPORTS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
2.170
VACUUM MEASUREMENT, CONTROL AND ADJUSTMENT
INSTRUMENTS
3
CONVERSION TABLES
3.00
VACUUM AND PRESSURE GAUGES
The measurement method of our vacuum gauges is based on the principle of the Bourdon
spring (Eugène Bourdon, France, 1808 – 1884).
It is made using section tubes in special copper alloy, one end is welded to the threaded
pin of the vacuum-pressure gauge, thus forming a single body with it, while the
Sp14
3
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Weight
Item
KPa scale error use material g
09 03 15 0 ÷ -100 -- 2.5% -10 °C ÷ +50 °C dry Black plastic 52
Sp14
PRESSURE GAUGES
Scale Double Scale Admissable Temperature of Notes Case Weight
Item
bar scale error use material g
09 03 20 0 ÷ 1.6 0 ÷ 23 psi 2.5% -10 °C ÷ +50 °C dry Black plastic 54
09 03 25 0 ÷ 10 0 ÷ 1.0 MPa 2.5% -10 °C ÷ +50 °C dry Black plastic 54
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.01
VACUUM GAUGES
3D drawings are available on vuototecnica.net
Sp14
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Weight
Item
3 mbar KPa scale error use material g
09 03 10 0 ÷ -1000 0 ÷ -100 2.5% -10 °C ÷ +50 °C dry black plastic 134
3 holes Ø 3.5
at 120°
Sp14
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Flange Weight
Item
mbar KPa scale error use material material g
09 01 10 0 ÷ -1000 0 ÷ -100 2.5% -10 °C ÷ +50 °C dry black plastic chrome-plated steel 162
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.02
VACUUM GAUGES
Sp14
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Flange Weight
Item
mbar KPa scale error use material material g 3
09 01 16 0 ÷ -1000 0 ÷ -100 1.6% -10 °C ÷ +50 °C in glycerine bath Die-cast brass chrome-plated steel 348
3 holes Ø 4.5
at 120°
Sp14
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case and flange Weight
Item
mbar KPa scale error use material g
09 02 10 0 ÷ -1000 0 ÷ -100 1% -10 °C ÷ +50 °C dry black steel 346
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.03
VACUUM GAUGES
3D drawings are available on vuototecnica.net
Sp14
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Weight
Item
3 mbar KPa scale error use material g
09 05 10 0 ÷ -1000 0 ÷ -100 2.5% -10 °C ÷ +50 °C dry black plastic 136
Sp14
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Weight
Item
mbar KPa scale error use material g
09 05 16 0 ÷ -1000 0 ÷ -100 1.6% -10 °C ÷ +50 °C in glycerine bath stainless steel 218
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.04
VACUUM GAUGE WITH STEEL PUNCH
This vacuum gauge with punch has been designed to allow the immediate
detection of the level of vacuum inside tin cans and food containers in
general.
The glycerine bath vacuum gauge item 09 05 16 used for this application
Sp14
Vacuum gauge
item 09 05 16 Sp17
Punch
item 00 08 152
Vacuum cup
item 01 40 15s
VACUUM GAUGE
Scale Double Scale Admissable Temperature of Notes Case Weight
Item
mbar KPa scale error use material g
09 05 99 0 ÷ -1000 0 ÷ -100 1.6% -10 °C ÷ +50 °C in glycerine bath stainless steel 250
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
3.05
MINI PNEUMATIC VACUUM SWITCHES
Adjustment screw
Vacuum
connection
Item 12 01 30 12 02 30
Adjustment range mbar abs. 930 ÷ 50 900 ÷ 40
Fixed differential mbar 50 ÷ 80 150 ÷ 180
Repeatability mbar ±5 ±5
Signal at rest NC NO
Supply pressure bar 2÷8 2÷8
Pneumatic microvalve item 00 12 17 00 12 18
Max flow rate of the microvalve at 6 bar NI / s 1.2 1.2
Operating temperature °C -10 ÷ +60 -10 ÷ +60
Weight g 104 102
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.06
MINI ELECTROMECHANICAL VACUUM SWITCH
Adjustment screw
NBR rubber
protection
Vacuum
connection
Item 12 02 10
Adjustment range mbar abs. 930 - 10
Fixed differential mbar abs. from 50 to 60
Repeatability mbar ±1.5
Maximum overpressure bar 5
Microswitch item 00 12 12
Contacts one in commutation
Flow rate of contacts A 10.1 at 250 VAC
Electrical connections Type 110 fast-on terminals
Operating temperature °C -25 - +80
Protection IP 55
Weight g 102
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.07
MICRO DIGITAL VACUUM SWITCHES
A red LED near the screw indicates the digital output signal commutation
status.
The pressure differential (hysteresis) between the set maximum value and
the value of reset of the rest signal is 2% of the set value and cannot be
adjusted.
They are composed of a polycarbonate enclosure, which includes the
sensor and the electric circuit, and of a coupler or a small aluminium
manifold with the vacuum connections.
Item 12 05 10 can also be rotated freely to place the display in the desired
position, without having to unscrew it from the vacuum connection. The
vacuum connection can be carried out via male or female M5 connectors,
while the electrical connection is made via a three-connector cable with
which they are equipped. Mini digital vacuum switches are suited for
controlling dry air and non-corrosive gasses. They are recommended in all
those cases that require a signal when a certain level of vacuum is reached,
for safety, for starting a cycle, for checking the cup grip, etc.
Item 12 05 10 *
Vacuum Seal
connection Hex. 8
3
Fitting (nickel-plated Body (polycarbonate)
brass)
Red LED
Three-pole shielded cable Ø 3.2 L=1500 mm
Adjustment screw
Item 12 05 11 *
Manifold (anodised aluminium)
Body (polycarbonate)
Red LED
Three-pole shielded cable Ø 3.2 L=1500 mm
Adjustment screw
Vacuum connection
* Complete the code indicating the electrical type of the output: P = PNP; N = NPN
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
3.08
MICRO DIGITAL VACUUM SWITCHES
Indicator
Vacuum
Positive pole
Sensor
Main load
circuit
Output signal
Negative pole
Hysteresis
Vacuum 3
Sensor Positive pole
Main
circuit Output signal
load
Negative pole
3.09
ANALOGUE VACUUM SWITCH
Electrical
connection
Vacuum
connection
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.10
ANALOGUE VACUUM SWITCH
2 M4x20 screws
Accessories
Electrical connection cable With axial connector, 5 m - PUR M8 x 1x 0.25 mm - Item 00 12 20
Electrical connection cable With radial connector, 5 m - PUR M8 x 1x 0.25 mm - Item 00 12 21
Wall fixing kit Support with o-ring and screws - Item 00 12 22
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.11
DIGITAL VACUUM AND PRESSURE SWITCHES
Electrical
connection
Vacuum and
compressed
air connection
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.12
DIGITAL VACUUM AND PRESSURE SWITCHES
2 M4x20 screws
Accessories
Electrical connection cable With axial connector, 5 m - PUR M8 x 1x 0.25 mm - Item 00 12 20
Electrical connection cable With radial connector, 5 m - PUR M8 x 1x 0.25 mm - Item 00 12 21
Wall fixing kit Support with o-ring and screws - Item 00 12 22
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.13
DIGITAL VACUUM SWITCHES
Item 12 30 10
Vacuum M8 connection
connection - 4 pin
Item 12 30 10 A
Vacuum
connection
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.14
DIGITAL VACUUM SWITCHES
WIRING DIAGRAMS
MAIN COMMUTATION
Analogue OUT
orange
CIRCUIT
Load
Load
Load
Load
DC Blue DC Blue
Item 12 30 10 A Item 12 30 10
3.15
DIGITAL VACUUM AND PRESSURE SWITCHES
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.16
DIGITAL VACUUM AND PRESSURE SWITCHES
WIRING DIAGRAMS
MAIN COMMUTATION
Load
Load
OUT 1 Black OUT 1 Black
Load
CIRCUIT
Load
DC Blue DC Blue
Accessories
Fixing kit wall - Item 00 12 30
table - Item 00 12 31
panel - Item 00 12 32
Note: Add the letter N after the item (for example 12 20 10 N) for NPN and non PNP commutation output.
3.17
DIGITAL VACUUM AND PRESSURE SWITCHES WITH TWO-COLOUR DISPLAY
These devices are also enclosed within a robust ABS container. They are carefully
calibrated and at compensated temperature, ensuring high-precision measurement
values. Detected values are viewed on the main two-colour (red and green) display and
programmable by the user to set different conditions. Setting values are easily viewable
3D drawings are available on vuototecnica.net
on a secondary display within the command panel. Two luminous indicators pertaining
to outlets 1 and 2 indicate the switching status of both digital and the analogue output
signals.
The switching outputs are completely independent.
The switching points within the scale values, including hysteresis, are easily
programmable via the buttons located on the control panel. Additional functions are also
programmable, such as comparison between two values, NO and NC contacts, choice of
measurement unit, programmed value and function blocking, etc. The connection to the
vacuum may be established by means of a male G 1/8" or female M5 double threading
connection. It is possible to establish an electric connection by means of a removable,
rapid installation data cable, supplied as standard.
Digital vacuum and pressure switches are suitable for measuring and controlling dry
air and non-corrosive gases. They are recommended in all those cases that require
a signal when a certain level of vacuum is reached set for safety, for starting a cycle,
for checking the cup grip, etc. Moreover, the hysteresis function allows managing the
vacuum generator compressed air supply, allowing considerable energy saving.
Sp12
Vacuum and
compressed
air connection
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.18
DIGITAL VACUUM AND PRESSURE SWITCHES WITH TWO-COLOUR DISPLAY
WIRING DIAGRAMS
MAIN COMMUTATION
Analogue OUT
orange
OUT 1 Black
Load
OUT 2 White
CIRCUIT
Load
Load
DC Blue
Accessories
Fixing kit wall - Item 00 12 40
table - Item 00 12 41
panel - Item 00 12 42
panel + protection - Item 00 12 43
3.19
ACCESSORIES FOR ANALOGUE AND DIGITAL VACUUM AND PRESSURE SWITCHES
ITEM 12 20 10P and 12 35 10P
FIXING KIT
3D drawings are available on vuototecnica.net
Wall Item 00 12 30
2 M4x6 screws
Table Item 00 12 31
2 M4x6 screws
Panel Item 00 12 32
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
3.20
ACCESSORIES FOR ANALOGUE AND DIGITAL VACUUM AND PRESSURE SWITCHES
ITEM 12 40 10, 12 40 12 and 12 40 20
FIXING KIT
Wall Item 00 12 40
2 M3x0.5 screws
Panel Item 00 12 42
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
3.21
ACCESSORIES FOR ANALOGUE AND DIGITAL VACUUM AND PRESSURE SWITCHES
Item Description
Electrical connection cable with M8 - 4 pin axial connector
00 12 20 for digital vacuum and pressure switches
Cable length 5 m
Item Description
Electrical connection cable with M8 - 4 pin radial connector
00 12 21 for digital vacuum and pressure switches
Cable length 5 m
3
2 M4x20 screws
O-ring 2043
Item Description
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.22
VACUUM ADJUSTMENT VALVES
Sp1
Sp1
Sp
Sp1
Sp
Sp
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.23
VACUUM REGULATORS
Adj. screw
Cap
Vacuum gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.24
REGULATORS FOR ROUGH VACUUM LEVELS
3
Adj. screw
Cap
Vacuum gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.25
VACUUM REGULATORS WITH PNEUMATIC ADJUSTMENT
Vacuum regulators with pneumatic adjustment differ from the previous ones for the way they adjust the
level of vacuum; in fact, instead of acting manually on the adjustment screw, it is necessary to act on the
pneumatic cylinder compressed air supply: the higher the pressure, and the higher the level of vacuum
and vice-versa.
3D drawings are available on vuototecnica.net
Vacuum regulators are used to adjust the pre-set level of vacuum and keep it constant (secondary
vacuum), regardless of the pump vacuum level or the vacuum level (primary vacuum).
Unlike the vacuum adjusting valves, regulators do not introduce atmospheric air into the circuit,
thus producing more gripping points with different vacuum values, from only one vacuum
source.
Their operating principle is based on the contrasting action between a pneumatic
cylinder with short stroke and a fluctuating piston driven by the pressure differential
existing between the secondary vacuum and the atmospheric pressure.
Technical features
- Operation: membrane-piston regulator
- Supply pressure: from 0 to 3 bar for regulators item 11 .. 30;
from 0 to 5 bar for regulators item 11 .. 80.
- Adjustable working pressure: from 800 to 1 mbar abs. for regulators item 11 .. 30;
from 980 to 1 mbar abs. for regulators item 11 .. 80:
- Flow rate: from 2 to 160 m3/h.
- Room temperature: from -10 to +80 °C
- Installation position: any
Usage
Vacuum regulators are mainly used on centralised plants where, regardless of the plant level of vacuum, each
grip can be adjusted within that value. Moreover, they are necessary whenever the working vacuum must be
lower than the primary vacuum and kept constant. Vacuum regulators with pneumatic adjustment can be
installed away from the control point, since it is sufficient to have a pressure regulator on the control panel to
act on them.
3
Cap
Vacuum gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
3.26
DIAGRAMS REFERRING TO THE LEVEL OF VACUUM ACCORDING TO THE SERVO-
CONTROL SUPPLY PRESSURE
100
100
80
90
70
80
60 11 01 30
11 02 30
70 11 03 30
-Kpa
50
11 04 30
11 05 30
60 11 01
06 30
40
11 02 30
11 03 30
-Kpa
50
30 11 04 30
11 05 30
40 11 06 30
20
30
10
20
0
3
0 0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2,5 2,75
10
bar
0
100
0 0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2,5 2,75
90 bar
100
80
90
70
80
60
70 11 03 80
-Kpa
50 11 05 80
11 06 80
60
40
11 03 80
-Kpa
50 11 05 80
30
11 06 80
40
20
30
10
20
0
0 0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2,5 2,75 3 3,25 3,5 3,75 4 4,25 4,5
10
bar
0
0 0,25 0,5 0,75 1 1,25 1,5 1,75 2 2,25 2,5 2,75 3 3,25 3,5 3,75 4 4,25 4,5
bar
Note: The values shown in the tables are purely indicative as they depend on atmospheric pressure, the flow rate of the vacuum source and the quality of the compressed air supply
3.27
SEALING KIT FOR VACUUM REDUCERS
3D drawings are available on vuototecnica.net
Vacuum regulator
Item
item
00 11 113 11 01 10
00 11 114 11 02 10
00 11 115 11 03 10
00 11 116 11 04 10
00 11 117 11 05 10
00 11 118 11 06 10
00 11 119 11 03 50
00 11 120 11 04 50
00 11 121 11 05 50
00 11 122 11 01 30
00 11 123 11 02 30
00 11 124 11 03 30
00 11 125 11 04 30
00 11 126 11 05 30
00 11 127 11 06 30
00 11 128 11 03 80
00 11 129 11 05 80
00 11 130 11 06 80
3.28
VACUUM VALVES AND SOLENOID
VALVES
Quick coupling
fitting
Two-way Fitting
manual valve for TPR hose 4
Sp
Coupler
Sealing gasket
Distributor
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.01
SUCTION VALVES FOR RESIN INFUSION MOULDS
MOULD
Quick coupling
fitting
4
Two-way Fitting
manual valve for TPR hose
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.02
PLUNGER VALVES
Sp22
Sp22
Nylon disc
Sp22
Sp22
Nylon disc
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.03
MECHANICALLY OPERATED VALVES
Sp30
A B C D E F G H I Weight
Item
Ø Ø Ø Ø g
19 02 30 112 80 23 35 9 G3/8” 63 8 M20 x 1 252
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.04
VALVES WITH BALL SHUTTER
Valves with ball shutters activate suction, creating vacuum in the cups on which they are
applied, only when the load to be held activates the sealing shutter.
They are made of an anodised aluminium body, a nylon ball shutter, a calibrated thrust
spring and a threaded brass closing plug.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
4.05
SHUT-OFF VALVES
These are special one-way valves that, when properly calibrated, allow a certain
quantity of fluid to go through; afterwards, if the fluid continues to go through,
they automatically close.
These shut-off valves have been specially designed to be applied on the cups
3D drawings are available on vuototecnica.net
Hex. 13
A B C D D1 E Weight
Item
Ø Ø g
14 01 05 32 26 6 G1/8” G1/8” 8 8
Minimum trigger flow = 1.5 m3/h Minimum level of vacuum = -250 mbar
Hex. 20
A B C D D1 E Weight
Item
Ø Ø g
14 01 10 45 30 15 G1/4” G3/8” 14 28
Minimum trigger flow = 4 m /h3
Minimum level of vacuum = -250 mbar
Hex. 20
A B C D D1 E Weight
Item
Ø Ø g
14 01 15 45 30 15 G1/4” G1/4” 14 29
Minimum trigger flow = 4 m3/h Minimum level of vacuum = -250 mbar
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.06
SHUT-OFF VALVES
A D D1 E Weight
Item
Ø Ø g
14 02 10 59 G1/4” G1/4” 14 42
Minimum trigger flow = 4 m /h3
Minimum level of vacuum = -250 mbar
Hex. 20
A B C D D1 E Weight
Item
Ø Ø g
14 03 10 59 47 12 G3/8” G1/4” 14 36
Minimum trigger flow = 4 m /h3
Minimum level of vacuum = -250 mbar
Hex. 20
A B C D D1 E Weight
Item
Ø Ø g
14 05 10 59 47 12 G3/8” G1/4” 14 34
4
Minimum trigger flow = 4 m /h3
Minimum level of vacuum = -250 mbar
A B C D D1 E Weight
Item
Ø Ø g
Sp.22
14 06 10 50 38 12 G3/8” G3/8” 14 38
Minimum trigger flow = 4 m3/h Minimum level of vacuum = -250 mbar
These are based on the same operating principle as the previously described shut-off valves. They differ only
in the sealing shutter which, even when completely closed, allows the vacuum source a minimum of suction.
This feature helps pick up the vacuum cup that has not gripped the object, for example, due to early activation
of the suction, to recreate the vacuum inside it and then to grip without having to repeat the work cycle. If,
on the other hand, the vacuum cup does not grip because there is no object to be gripped, the valve does not
prevent the lowering of the level of vacuum on the remaining vacuum cups, but the small size of the loss is
easily controllable and therefore, recoverable.
Fully made with anodised aluminium.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.07
CHECK VALVES
These one-way valves are made with bronze and brass with a seal in
NBR nitrile rubber or, upon request, in Viton®, only for series 10 ... 11.
To ensure a practical assembly they are available in two versions:
horizontal and vertical.
3D drawings are available on vuototecnica.net
HORIZONTAL
Sp
R Sp H L Weight
Item
Ø Kg
10 02 10 G3/8” 27 49 43 0.19
10 03 10 G1/2” 27 49 43 0.17
10 04 10 G3/4” 34 58 52 0.27
10 05 10 G1” 42 66 62 0.43
4 10 06 10 G1” 1/4 50 75 72 0.59
10 07 10 G1” 1/2 57 86 80 0.79
10 08 10 G2” 69 99 94 1.08
Sp
VERTICAL
R Sp D H Weight
Item
Ø Ø Kg
10 01 11 G1/4” 21 28 47 0.10
10 02 11 G3/8” 25 35 59 0.17
10 03 11 G1/2” 26 35 58 0.12
10 04 11 G3/4” 33 42 65 0.28
10 05 11 G1” 40 48 74 0.42
10 06 11 G1” 1/4 50 61 82 0.64
10 07 11 G1” 1/2 55 71 92 0.87
10 08 11 G2” 70 87 100 2.70
Note: To order valves with seals in Viton®, add the letter V to the item (example: 10 02 11 V)
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.08
MEMBRANE CHECK VALVES
Sp
R Sp D H Weight
Item
Ø Ø g
10 01 15 G1/4” 20 30 42 46
10 02 15 G3/8” 24 35 50 74
10 03 15 G1/2” 24 37 55 86
10 04 15 G3/4” 33 42 64 110
10 05 15 G1” 40 49 74 162
4
MANUAL 2-WAY MINIATURE VACUUM VALVES
Sp
D Mouth Sp E F H Weight
Item
Ø Ø g
13 01 11 G1/4” 8 21 7 32 39 80
13 02 11 G3/8” 8 21 10 30 40 74
13 03 11 G1/2” 10 25 12 33 45 110
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.09
MANUAL 2-WAY AND 3-WAY VACUUM VALVES
These manual valves are used for intercepting vacuum in all those
plants where solenoid valves cannot be installed.
They feature a die-cast nickel-plated brass body, a chromed brass
ball shutter and Teflon® seals to guarantee perfect seal even at high
3D drawings are available on vuototecnica.net
temperatures.
A lever on the ball shutter, manually rotated 90°, allows opening or
closing the valve precisely and with no effort.
Hex. G
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.10
MANUAL 3-WAY VACUUM VALVES
Hex. G
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.11
SERVO-CONTROLLED 3-WAY VACUUM VALVES
between the vacuum pump suction and the air inlet into the circuit for
a quick restoration of the atmospheric pressure.
They are composed of an anodised aluminium body, two Vulkollan®
shutters assembled onto a stainless steel stem, a membrane for
servo-control made with special compounds and a thrust spring for
the shutter return.
These valves allow reducing frictions and internal dynamic stresses to
the minimum. The result being a high response speed and a guarantee
of long lasting duration.
Technical features
Operating pressure: from 0.5 to 3000 absolute mbar
Servo-control pressure: see table
Temperature of suctioned fluid: from -5 to +60°C
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 01 31 G1/4” 6 1000 0.5 5 10 8.5 56.8 4÷7 0,32
07 02 31 G3/8” 10 1000 0.5 5 10 11.5 103.8 4÷7 0,31
Note: Valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.12
SERVO-CONTROLLED 3-WAY VACUUM VALVES
4
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-en. Ø mm2 *bar Kg
07 03 31 G1/2” 20 1000 0.5 6 15 15.0 176 6÷8 0.490
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 04 31 G3/4” 40 1000 0.5 7 16 20 314 6÷8 1.060
07 05 31 G1” 90 1000 0.5 7 16 25 490 6÷8 0.964
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.13
SERVO-CONTROLLED 3-WAY VACUUM VALVES
3D drawings are available on vuototecnica.net
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 06 31 G1” 1/2 230 1000 0.5 65 30 40 1256 6÷8 4.456
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.14
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES, FOR LARGE FLOW RATES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 08 31 G2” 390 1000 0.5 110 70 52 2123 4÷8 5.5
Note: Valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.15
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES, FOR LARGE FLOW RATES
3D drawings are available on vuototecnica.net
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 09 31 G3” 750 1000 0.5 132 84 80 5024 4÷8 11.4
Note: Valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.16
2-WAY AND 3-WAY VACUUM SOLENOID PILOT VALVES
Electric coil
Connector
P = Pump
A = Use
R = Discharge
3-WAY SOLENOID PILOT VALVES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of B E H I Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 g
07 01 16 G1/4” 4 1000 0.5 15 8 6 28.3 73 86 25 67 248
Note: The coil and the connector are not integral parts of the solenoid pilot valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.17
3-WAY VACUUM SOLENOID PILOT VALVES
3D drawings are available on vuototecnica.net
Electric coil
Connector
P = Pump
A = Use
R = Discharge
3-WAY SOLENOID PILOT VALVES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of B E H I Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 g
07 02 16 G3/8” 8 1000 0.5 22 10 10 78.5 85 98 35 79 392
07 03 16 G1/2” 10 1000 0.5 28 10 12 113.0 85 98 35 79 377
Note: The coil and the connector are not integral parts of the solenoid pilot valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.18
2-WAY VACUUM SOLENOID PILOT VALVES
Connector
P = Pump
A = Use
2-WAY SOLENOID PILOT VALVES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of B E H I Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 g
07 01 20 G1/4” 4 1000 0.5 15 8 6 28.3 73 86 25 67 244
Note: The coil and the connector are not integral parts of the solenoid pilot valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.19
2-WAY VACUUM SOLENOID PILOT VALVES
3D drawings are available on vuototecnica.net
4
Electric coil
Connector
P = Pump
A = Use
2-WAY SOLENOID PILOT VALVES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of B E H I Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 g
07 02 20 G3/8” 8 1000 0.5 22 10 10 78.5 85 98 35 79 384
07 03 20 G1/2” 10 1000 0.5 28 10 12 113.0 85 98 35 79 372
Note: The coil and the connector are not integral parts of the solenoid pilot valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.20
DIRECT DRIVE 2-WAY VACUUM SOLENOID VALVES
These state of the art solenoid valves feature minimal overall dimensions and
high volumetric efficiency and high response speed at any level of vacuum.
They are the result of an attentive choice of materials, state of the art
constructive techniques and of the in-depth knowledge of our technicians. This
Electric coil
4
Connector
P = Pump
A = Use
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of B C D E F G Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Kg
DDN 14 G1/2” 20 1000 0.5 30 15 14 154 127 35 110 30 63 75 0.83
DDN 25 G1” 90 1000 0.5 55 33 25 490 142 50 128 43 82 90 1.56
Note: The coil and the connector are not integral parts of the solenoid pilot valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.21
DIRECT DRIVE 2-WAY VACUUM SOLENOID VALVES
These direct drive two-way, two-position vacuum solenoid valves in the new series feature
a conical shutter servo-controlled by the vacuum.
They are normally closed, but they can be supplied normally open upon request.
They are composed of an anodised aluminium body where the connections are located,
3D drawings are available on vuototecnica.net
a conical silicon shutter assembled onto a stainless steel stem and a membrane in
a special rubberised and coated compound. An actuator activated by an electric coil
manages the vacuum at the servo-control. The operating principle of these solenoid
valves is based on the pressure differential between the vacuum pump or generator and
the pressure of the suctioned air. By addressing this “differential pressure” to the servo-
control via the actuator, the shutter can be controlled without compressed air or springs.
Due to their operating principle, they are not recommended on plants with rough vacuum
levels (below 850 absolute mbar, equal to 15% vacuum).
The lack of springs, frictions and internal dynamic stresses favours a high response
speed and guarantees long lasting operation of the solenoid valve.
The standard electric coil is fully plasticised with synthetic resin, tight execution,
insulation class F (up to 155°C) compliant with VDE standards, with 6.3 mm three-
terminal electrical connections in compliance with EN 175301-803 (ex-DIN 43650).
Protection degree IP 54, IP 65 with connector inserted.
Tolerance permitted on the nominal voltage value: ± 10%.
Maximum absorption: 20 V.A. with AC and 18 W with DC.
The electric coil can be rotated 360°. The connector can be rotated 180° on the coil
and can be supplied, upon request, with LED light, anti-interference circuit and/or with
protection devices against overvoltage and polarity reversal.
This series of solenoid valves can be used on vacuum systems without compressed air
and in all applications where suction has to be controlled separately from the air inlet into
circuit, such as degasifiers, autoclaves, vacuum thermo-welders, etc. The solenoid valve
must be always chosen according to the flow rate and, therefore, to the vacuum pump or
generator suction connection.
Technical features
Operating pressure: from 0.5 to 850 absolute mbar
Temperature of suctioned fluid: from – 5 to + 60°C
4
Connector
Electric coil
A = Use
P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
EGN 40 NC G1” 1/2 230 850 0.5 75 50 40 1256 M8 4.07
70 60
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.02
4.21-1
DIRECT DRIVE 2-WAY VACUUM SOLENOID VALVES
Connector
A = Use
P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
EGN 40 NO G1” 1/2 230 850 0.5 75 50 40 1256 M8 4.07
70 60
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.22-1
4.03
DIRECT DRIVE 2-WAY VACUUM SOLENOID VALVES
3D drawings are available on vuototecnica.net
Connector
4
Electric coil
A = Use
P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
EGN 52 NC G2” 390 850 0.5 75 50 52 2123 M8 6.70
70 60
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.04
4.23-1
DIRECT DRIVE 2-WAY VACUUM SOLENOID VALVES
A = Use
P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
EGN 52 NO G2” 390 850 0.5 75 50 52 2123 M8 6.70
70 60
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.24-1
4.05
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
The three-way vacuum solenoid valves in this series are two-position valves with
pneumatically servo-controlled conical shutters.
They can be used normally either closed or open.
They are composed of an anodised aluminium body, two Vulkollan® shutters assembled
3D drawings are available on vuototecnica.net
onto a stainless steel stem, a membrane for servo-control made with special compounds
and a thrust spring for the shutter return; an actuator activated by an electric coil
managed the compressed air supply.
These valves allow reducing frictions and internal dynamic stresses to the minimum.
The result being a high response speed and a guarantee of long lasting duration.
The standard electric coil is fully plasticised with synthetic resin, tight execution,
insulation class F (up to 155°C) compliant with VDE standards, with 6.3 mm three-
terminal electrical connections in compliance with EN 175301-803 (ex DIN 43650).
Protection degree IP 54; IP 65 with connector inserted.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum absorption: 20 V.A. with AC and 18 W with DC.
The electric coil can be rotated 360°. The connector can be rotated 180° on the coil
and can be supplied, upon request, with LED lights, anti-interference circuit and/or with
protection devices against overvoltage and polarity reversal.
The three-way vacuum solenoid valves are used for vacuum interception on power supply
units and suction palletisers, robots, feeders, bag opening units and in all those cases
where rapid exchange between pump suction for vacuums and air supply into the circuit
is necessary for quick restoration of atmospheric pressure.
Technical features
Operating pressure: from 0.5 to 3000 absolute mbar
Servo-control pressure: see table
Temperature of suctioned fluid: from -5 to +60°C
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 01 11 G1/4” 6 1000 0.5 16 27 8.5 56.8 4÷7 0.56
07 02 11 G3/8” 10 1000 0.5 16 27 11.5 103.8 4÷7 0.54
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.22
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 03 11 G1/2” 20 1000 0.5 16 40 15.0 176 6÷8 0.73
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.23
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
3D drawings are available on vuototecnica.net
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 04 11 G3/4” 40 1000 0.5 16 40 20 314 6÷8 1.25
07 05 11 G1” 90 1000 0.5 18 42 25 490 6÷8 1.16
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.24
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
Electric coil
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 06 11 G1” 1/2 230 1000 0.5 60 38 40 1256 6÷8 4.79
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.25
3-WAY VACUUM SOLENOID VALVES, PILOT-OPERATED FOR LARGE CAPACITIES
Strengthened by our constant desire for research and innovation and our experience, acquired over more
than forty years of operations in the vacuum sector, we have made these new solenoid valves using
absolutely innovative technologies, to guarantee exceptionally low intervention times, almost negligible
pressure drops, and minimal dimensions compared to the large connections with which they are equipped.
3D drawings are available on vuototecnica.net
Furthermore, we have obtained them from aluminium block to eliminate even the slightest chance of loss
due to transpiration, as perhaps could occur with a fusion.
This new series of solenoid valves for vacuums are three-way, two-position and are composed of:
- An anodised aluminium body set with attachment connections
- Two conical Vulkollan® shutters fitted on the aluminium pistons, pneumatically powered with spring
return
- An actuator, powered by an electrical coil to manage compressed air supply
The composition of these valves, especially the original Teflon® slide system that the pistons have been
equipped with, help minimise friction and internal dynamic stress, deriving high response speed and
ensuring enduring operation.
They can be used normally either closed or open.
The standard electric coil of the actuator is fully plastic-coated in synthetic resin, watertight,
insulation class F (up to 155°C) as per standard VDE, with 6.3 mm three-terminal electrical
connections for connectors in compliance with EN 175301-803.
Degree of protection IP 54;
IP 65 with connector inserted.
Tolerance permitted on the nominal voltage value: ± 10%.
Maximum absorption: 20 VA in AC and 18 W in DC.
The electric coil can be rotated 360°. The connector can be rotated 180° on the coil and can be
supplied, upon request, with LED lights, anti-interference circuit and/or with protection devices against
overvoltage and polarity reversal.
The three-way solenoid valves are used for vacuum interception on power supply units and suction
palletisers, vacuum thermoformers, vacuum packaging units, robots, feeders, bag opening units and in all
those cases where rapid exchange between pump suction for vacuums and air supply into the circuit is
necessary for quick restoration of atmospheric pressure.
Technical features
Operating pressure: from 0.5 to 1000 absolute mbar
Servo-control pressure: from 4 to 8 bar
4 Temperature of suctioned fluid: from – 5 to + 60°C
Connector
Electric coil
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 08 11 G2” 390 1000 0.5 78 50 52 2123 4÷8 5.87
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.26
3-WAY VACUUM SOLENOID VALVES, PILOT-OPERATED FOR LARGE CAPACITIES
Electric coil
4
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 09 11 G3” 750 1000 0.5 132 84 80 5024 4÷8 11.8
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.27
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH TWO ELECTRIC COILS
These solenoid valves have the same function and the same structure as the
previously described three-way valves.
Even their structure is the same, but their distinctive features are the two coils
that with a simple electric impulse exchange the shutter positions and keep
3D drawings are available on vuototecnica.net
them in this position till the next impulse even in absence of compressed air at
the servo control and of electric current.
This is the reason why their use is especially recommended in all those cases
requiring maximum connection security at the vacuum source, even in the
absence of electrical and pneumatic power supply.
The standard electric coils are fully plastic-coated in synthetic resin, watertight,
insulation class F (up to 155°C) as per standard VDE, with 6.3 mm three-terminal
electrical connections for connectors in compliance with EN 175301-803
(ex DIN 43650). Protection degree IP 54; IP 65 with connector inserted.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum absorption: 8 - 20 V.A. with AC and 6.5 - 18 W with DC.
The electric coils can be rotated 180°. The connectors can be rotated 180° on
the coils and can be supplied, upon request, with LED lights, anti-interference
circuit and/or with protection devices against overvoltage and polarity reversal.
Technical features
Operating pressure: from 0.5 to 3000 absolute mbar
Servo-control pressure: see table
Temperature of suctioned fluid: from -5 to +60°C
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 01 51 G1/4” 6 1000 0.5 16 27 8.5 56.8 4÷7 0.59
07 02 51 G3/8” 10 1000 0.5 16 27 11.5 103.8 4÷7 0.58
Note: The coils and the connectors are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.28
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH TWO ELECTRIC COILS
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 03 51 G1/2” 20 1000 0.5 16 40 15.0 176 6÷8 0.97
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: The coils and the connectors are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.29
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH TWO ELECTRIC COILS
3D drawings are available on vuototecnica.net
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 04 51 G3/4” 40 1000 0.5 16 40 20 314 6÷8 1.51
07 05 51 G1” 90 1000 0.5 18 42 25 490 6÷8 1.41
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: The coils and the connectors are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.30
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH TWO ELECTRIC COILS
Electric coil
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 06 51 G1” 1/2 230 1000 0.5 60 38 40 1256 6÷8 5.24
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: The coils and the connectors are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.31
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH TWO ELECTRIC COILS, FOR LARGE CAPACITIES
The innovative construction technology of these solenoid valves and
their conformation are the same as those previously described. What
differentiates them are the two simple electrical impulse coils that
exchange the shutter positions and keep them in position until the
3D drawings are available on vuototecnica.net
Connector
4
Electric coil
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 08 51 G2” 390 1000 0.5 78 50 52 2123 4÷8 6.0
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.32
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH TWO ELECTRIC COILS, FOR LARGE CAPACITIES
Electric coil
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 09 51 G3” 750 1000 0.5 132 84 80 5024 4÷8 11.8
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.33
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES
These direct drive three-way, two-position vacuum solenoid valves feature conical shutters
servo-controlled by the vacuum.
They are normally closed as standard, but they can be supplied normally open upon request.
They are composed of an anodised aluminium body where the connections are located, two
3D drawings are available on vuototecnica.net
silicone shutters assembled onto a stainless steel stem and a membrane in special reinforced
compound. An actuator activated by an electric coil manages the vacuum at the servo-control.
The operating principle of these solenoid valves is based on the pressure differential between
the vacuum pump or generator and the pressure of the suctioned air.
By addressing this “differential pressure” to the servo-control via the actuator, the shutters can
be controlled without compressed air or springs.
Due to their operating principle, they are not recommended on plants with rough vacuum
levels (below 850 absolute mbar, equal to 15 % vacuum).
The lack of springs, frictions and internal dynamic stresses favours a high response speed and
guarantees long lasting operation.
The standard electric coil is fully plasticised with synthetic resin, tight execution, insulation
class F (up to 155°C) compliant with VDE standards, with 6.3 mm three-terminal electrical
connections in compliance with EN 175301-803 (ex DIN 43650). Protection degree IP 54; IP 65
with connector inserted.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum absorption: 20 V.A. with AC and 18 W with DC.
The electric coil can be rotated 360°. The connector can be rotated 180° on the coil and can be
supplied, upon request, with LED lights, anti-interference circuit and/or with protection devices
against overvoltage and polarity reversal.
The solenoid valves in this series, along with the uses described for the 07 .. 11 series, can be
used on plants with no compressed air.
The solenoid valve must be always chosen according to the flow rate and, therefore, to the
vacuum pump or generator suction connection.
Technical features
Operating pressure: from 0.5 to 850 absolute mbar
Temperature of suctioned fluid: from -5 to +60°C
4
Connector Electric coil
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 03 40 NC G1/2” 20 850 0.5 30 15 15 176 6.5 1.53
07 03 40 NO 20 18
07 04 40 NC G3/4” 40 850 0.5 30 15 20 314 6.5 1.50
07 04 40 NO 20 18
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.34
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 05 40 NC G1” 90 850 0.5 38 18 25 490 6.5 1.91
07 05 40 NO 25 20
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.35
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES
3D drawings are available on vuototecnica.net
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 06 40 NC G1” 1/2 230 850 0.5 75 50 40 1256 10.5 5.90
07 06 40 NO 70 60
Note: The coil and the connector are not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.36
SOLENOID VALVE ACCESSORIES AND SPARE PARTS
Electric coils
Electric coils are windings of copper wire on nylon coils fully
plasticised in synthetic resin which activate the electromagnetic
actuators with which the solenoid valves are provided. Crossed by an
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
4.37
SOLENOID VALVE ACCESSORIES AND SPARE PARTS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
4.38
SOLENOID VALVE ACCESSORIES AND SPARE PARTS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
4.39
SOLENOID VALVE ACCESSORIES AND SPARE PARTS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
4.40
VACUUM VALVE AND SOLENOID VALVE SEALING KIT
Sealing kits are composed of a membrane, shutters and standard O-rings installed on our compressed air
and vacuum three-way valves and solenoid valves.
In the presence of very hot fluids (up to 250°C) or corrosive fluids, we can supply sealing kits in special
compounds. Please contact our technical department.
4.41
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH LOW ABSORPTION ELECTRIC COIL
The three-way vacuum solenoid valves in this series are two-position valves with
pneumatically servo-controlled conical shutters.
They can be used normally either closed or open.
They are composed of an anodised aluminium body, two Vulkollan® shutters
3D drawings are available on vuototecnica.net
assembled onto a stainless steel stem, a membrane for servo-control made with special
compounds and a thrust spring for the shutter return; a solenoid pilot valve activated by
a built-in electric coil managed the compressed air supply.
These valves allow reducing frictions and internal dynamic stresses to the minimum.
The result being a high response speed and a guarantee of long lasting duration.
The electric coils of the solenoid pilot valve are fully plastic-coated in synthetic resin,
watertight, insulation class F (up to 155°C) as per standard VDE, with 3 mm two-terminal
electrical connections for connectors in compliance with EN 175301-803
(ex DIN 43650) - C. Protection degree IP 54; IP 65 with connector inserted.
Available for voltages 12-24V/50-60Hz and 12-24VDC.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum electric power: 2 W
The connector can be rotated 180° on the coil and can be supplied, upon request, with
LED lights, anti-interference circuit and/or with protection devices against overvoltage
and polarity reversal.
A push-button device, built-in the solenoid pilot valve, allows manually opening and
closing the solenoid valve.
The 3-way vacuum solenoid valves are used for vacuum interception on power supply
units and suction palletisers, robots, feeders, bag opening units and in all those cases
where rapid exchange between pump suction for vacuums and air supply into the circuit
is necessary for quick restoration of atmospheric pressure.
Technical features
Operating pressure: from 0.5 to 3000 absolute mbar
Servo-control pressure: see table
Temperature of suctioned fluid: from -5 to +60°C
Connector
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 01 13 G1/4” 6 1000 0.5 16 27 8.5 56.8 4÷7 0.44
07 02 13 G3/8” 10 1000 0.5 16 27 11.5 103.8 4÷7 0.43
Note: Specify the voltage of the electric coil when ordering. (Example: 07 01 13 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.42
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH LOW ABSORPTION ELECTRIC COIL
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 03 13 G1/2” 20 1000 0.5 16 40 15.0 176 6÷7 0.52
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Specify the voltage of the electric coil when ordering. (Example: 07 03 13 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.43
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH LOW ABSORPTION ELECTRIC COIL
3D drawings are available on vuototecnica.net
Connector
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 04 13 G3/4” 40 1000 0.5 16 40 20 314 6÷7 1.00
07 05 13 G1” 90 1000 0.5 18 42 25 490 6÷7 0.94
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Specify the voltage of the electric coil when ordering. (Example: 07 04 13 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.44
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES
WITH LOW ABSORPTION ELECTRIC COIL
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 06 13 G1”1/2 230 1000 0.5 60 38 40 1256 6÷8 4.50
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Specify the voltage of the electric coil when ordering. (Example: 07 06 13 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.45
3-WAY VACUUM SOLENOID VALVES, PILOT-OPERATED FOR LARGE CAPACITIES WITH
LOW ABSORPTION ELECTRIC COIL
The growing demand by automatic machine manufacturers in the packaging sector and the lack of high-speed three-way
vacuum solenoid valves on the market for capacities above 200 m3/h have led us to design and implement this new series of
solenoid valves that are able to meet these needs.
Strengthened by our constant desire for research and innovation and our experience, acquired over more than forty years
3D drawings are available on vuototecnica.net
of operations in the vacuum sector, we have made these new solenoid valves using absolutely innovative technologies, to
guarantee exceptionally low intervention times, almost negligible pressure drops, and minimal dimensions compared to the
large connections and minimum electrical absorption for their powering with which they are equipped.
Furthermore, we have obtained them from aluminium block to eliminate even the slightest chance of loss due to
transpiration, as perhaps could occur with a fusion.
This new series of solenoid valves for vacuums are three-way, two-position and are composed of:
- An anodised aluminium body set with attachment connections
- Two conical Vulkollan® shutters fitted on the aluminium pistons, pneumatically powered with spring return
- A solenoid pilot valve powered by a low absorption fitted electrical coil which managed compressed air supply
The composition of these valves, especially the original Teflon® slide system that the pistons have been equipped
with, help minimise friction and internal dynamic stress, deriving high response speed and ensuring enduring
operation.
They can be used normally either closed or open.
The electric coils of the solenoid pilot valve are fully plastic-coated in synthetic resin, watertight, insulation class F (up
to 155°C) as per standard VDE, with 3 mm two-terminal electrical connections for connectors in compliance with EN
175301-803. Degree of protection IP 54;
IP 65 with connector inserted.
Available for voltages 12-24V/50-60Hz and 12-24VDC.
Tolerance permitted on the nominal voltage value: ± 10%.
Maximum electric power: 2 W
The connector can be rotated 180° on the coil and can be supplied, upon request, with LED lights, anti-interference
circuit and/or with protection devices against overvoltage and polarity reversal.
A push-button device, built-in the solenoid pilot valve, allows manually opening and closing the solenoid valve.
The three-way solenoid valves are used for vacuum interception on power supply units and suction palletisers, vacuum
thermoformers, vacuum packaging units, robots, feeders, bag opening units and in all those cases where rapid exchange
between pump suction for vacuums and air supply into the circuit is necessary for quick restoration of atmospheric
pressure.
Technical features
4 Working pressure: from 0.5 to 1000 absolute mbar
Servo-control pressure: from 4 to 8 bar
Suctioned fluid temperature: from – 5 to + 60°C
Connector
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 08 13 G2” 390 1000 0.5 78 50 52 2123 4÷8 5.87
Note: Specify the voltage of the electric coil when ordering. (Example: 07 08 13 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.46
3-WAY VACUUM SOLENOID VALVES, PILOT-OPERATED FOR LARGE CAPACITIES WITH
LOW ABSORPTION ELECTRIC COIL
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 09 13 G3” 750 1000 0.5 132 84 80 5024 4÷8 11.80
Note: Specify the voltage of the electric coil when ordering. (Example: 07 09 13 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.47
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE
SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
These solenoid valves have the same function and the same structure as the
previously described three-way valves.
Even their structure is the same; what differentiates them are the bistable
impulse solenoid pilot valve powered by a low absorption fitted electrical coil
3D drawings are available on vuototecnica.net
which, with a simple electrical impulse, exchanges the shutter positions and
keeps them there even in absence of electricity, until it receives a new impulse of
opposite polarity. For this reason, they can only be supplied with direct current
electric coils.
Their use is especially recommended in all those cases requiring maximum
connection security at the vacuum source, even in the absence of electrical
power supply.
The electric coils of the solenoid pilot valve are fully plastic-coated in synthetic
resin, watertight, insulation class F (up to 155°C) as per standard VDE, with 3
mm two-terminal electrical connections for connectors in compliance with EN
175301-803
(ex DIN 43650) - C. Protection degree IP 54; IP 65 with connector inserted.
Available for voltages 12-24VDC.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum electric power: 1 W
The connector can be rotated 180° on the coil and can be supplied, upon
request, with LED lights, anti-interference circuit and/or with protection devices
against overvoltage and polarity reversal.
The push-button device for their manual activation cannot be installed on these
solenoid valves.
Technical features
Operating pressure: from 0.5 to 3000 absolute mbar
Servo-control pressure: see table
Temperature of suctioned fluid: from -5 to +60°C
Connector
4
Solenoid pilot valve
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 01 53 G1/4” 6 1000 0.5 16 27 8.5 56.8 4÷7 0.44
07 02 53 G3/8” 10 1000 0.5 16 27 11.5 103.8 4÷7 0.43
Note: Specify the voltage of the electric coil when ordering. (Example: 07 01 53 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.48
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE
SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
Solenoid pilot
valve
4
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 03 53 G1/2” 20 1000 0.5 16 40 15.0 176 6÷7 0.52
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Specify the voltage of the electric coil when ordering. (Example: 07 03 53 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.49
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE
SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
3D drawings are available on vuototecnica.net
Connector
Solenoid pilot
valve
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 04 53 G3/4” 40 1000 0.5 16 40 20 314 6÷7 1.00
07 05 53 G1” 90 1000 0.5 18 42 25 490 6÷7 0.94
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Specify the voltage of the electric coil when ordering. (Example: 07 04 53 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.50
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE
SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
Interface
Quick valve
discharge
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 *bar Kg
07 06 53 G1”1/2 230 1000 0.5 60 38 40 1256 6÷8 4.50
* Add the letters LP to the item for servo-controlled pressures 4 - 6 bar.
Note: Specify the voltage of the electric coil when ordering. (Example: 07 06 53 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.51
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE
SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
FOR LARGE CAPACITIES
The innovative construction technology of these solenoid valves and their conformation
are the same as those previously described. What differentiates them are the bistable
impulse pilot valve powered by a low absorption fitted electrical coil which, with a
3D drawings are available on vuototecnica.net
simple electrical impulse, exchanges the shutter positions and keeps them there even
in absence of electricity, until it receives a new impulse of opposite polarity. For this
reason, they can only be supplied with direct current electric coils. This is the reason
why their use is recommended in all those cases requiring maximum connection
security at the vacuum source, even in the absence of an electrical power supply.
The electric coil of the pilot valve is fully plastic-coated in synthetic resin, watertight,
insulation class F (up to 155°C) as per standard VDE, with 3 mm two-terminal electrical
connections for micro connectors in compliance with EN 175301-803 (ex DIN 43650)
– C. Degree of protection IP 54; IP 65 with connector inserted. Available for voltages
12 – 24VDC.
Tolerance permitted on the nominal voltage value: ± 10%.
Maximum electric power: 1W
The connector can be rotated 180° on the coil and can be supplied upon request
with LED lights, with anti-interference circuit and/or with protection devices against
overvoltage. The push-button device for their manual activation cannot be installed on
these solenoid valves.
Technical features
Operating pressure: from 0.5 to 1000 absolute mbar
Servo-control pressure: from 4 to 8 bar
Temperature of suctioned fluid: from – 5 to + 60°C
Connector
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 08 53 G2” 390 1000 0.5 78 50 52 2123 4÷8 5.87
Note: Specify the voltage of the electric coil when ordering. (Example: 07 08 53 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.52
SERVO-CONTROLLED 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE
SOLENOID PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
FOR LARGE CAPACITIES
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of Pressure at Weight
Item abs. mbar msec passage servo-controlled
Ø m3/h min max energ. de-energ. Ø mm2 bar Kg
07 09 53 G3” 750 1000 0.5 132 84 80 5024 4÷8 11.80
Note: Specify the voltage of the electric coil when ordering. (Example: 07 09 53 V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
Solenoid valve servo-controlled power must be supplied with non-lubricated compressed air, 5 micron filtration, according to standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.53
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES
WITH LOW ABSORPTION ELECTRIC COIL
These direct drive three-way, two-position vacuum solenoid valves feature conical
shutters servo-controlled by the vacuum.
They are normally closed as standard, but they can be supplied normally open upon
request.
3D drawings are available on vuototecnica.net
They are composed of an anodised aluminium body where the connections are located,
two silicone shutters assembled onto a stainless steel stem and a membrane in
special reinforced compound. A solenoid pilot valve activated by a built-in electric coil
manages the vacuum at the servo-control. The operating principle of these solenoid
valves is based on the pressure differential between the vacuum pump or generator
and the pressure of the suctioned air. By addressing this “differential pressure” to the
servo-control via the solenoid pilot valve, the shutters can be controlled without
compressed air or springs.
Due to their operating principle stated above, they are not recommended on plants
with rough vacuum levels (below 850 absolute mbar, equal to 15 % vacuum).
The lack of springs, frictions and internal dynamic stresses favours a high response
speed and guarantees long lasting operation.
The electric coils of the solenoid pilot valve are fully plastic-coated in synthetic resin,
watertight, insulation class F (up to 155°C) as per standard VDE, with 3 mm two-
terminal electrical connections for connectors in compliance with EN 175301-803 (ex
DIN 43650) - C.
Protection degree IP 54; IP 65 with connector inserted.
Available for voltages 12-24V/50-60Hz and 12-24VDC.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum electric power: 2 W
The connector can be rotated 180° on the coil and can be supplied, upon request, with
LED lights, anti-interference circuit and/or with protection devices against overvoltage
and polarity reversal. A push-button device, built-in the solenoid pilot valve, allows
manually opening and closing the solenoid valve.
The solenoid valves in this series, along with the uses described for the 07 .. 11 series,
can be used on plants with no compressed air.
The solenoid valve must be always chosen according to the flow rate and, therefore, to
the vacuum pump or generator suction connection.
4 Technical features
Operating pressure: from 0.5 to 850 absolute mbar
Temperature of suctioned fluid: from -5 to +60°C
Connector
Manual drive
Solenoid pilot
valve
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 03 43 NC G1/2” 20 850 0.5 33 17 15 176 6.5 1.35
07 03 43 NO 22 20
07 04 43 NC G3/4” 40 850 0.5 33 17 20 314 6.5 1.30
07 04 43 NO 22 20
Note: Specify the voltage of the electric coil when ordering. (Example: 07 03 43 NC V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.54
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES
WITH LOW ABSORPTION ELECTRIC COIL
Solenoid pilot
valve
4
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 05 43 NC G1” 90 850 0.5 42 20 25 490 6.5 1.65
07 05 43 NO 28 22
Note: Specify the voltage of the electric coil when ordering. (Example: 07 05 43 NC V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.55
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE SOLENOID
PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
These solenoid valves have the same function and the same structure as the
previously described three-way valves.
Even their structure is the same; what differentiates them are the bistable
impulse pilot valve powered by a low absorption fitted electrical coil which, with
3D drawings are available on vuototecnica.net
a simple electrical impulse, exchanges the shutter positions and keeps them
there even in absence of electricity, until it receives a new impulse of opposite
polarity. For this reason, they can only be supplied with direct current electric
coils.
Their use is especially recommended in all those cases requiring maximum
connection security at the vacuum source, even in the absence of electrical
power supply.
The electric coils of the solenoid pilot valve are fully plastic-coated in synthetic
resin, watertight, insulation class F (up to 155°C) as per standard VDE, with 3
mm two-terminal electrical connections for connectors in compliance with EN
175301-803
(ex DIN 43650) - C. Protection degree IP 54; IP 65 with connector inserted.
Available for voltages 12-24VDC.
Tolerance permitted on the nominal voltage value: ±10%.
Maximum electric power: 1 W
The connector can be rotated 180° on the coil and can be supplied, upon
request, with LED lights, anti-interference circuit and/or with protection devices
against overvoltage and polarity reversal.
The push-button device for their manual activation cannot be installed on these
solenoid valves.
Technical features
Operating pressure: from 0.5 to 850 absolute mbar
Temperature of suctioned fluid: from -5 to +60°C
Connector
4
Solenoid pilot
valve
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 03 63 NC G1/2” 20 850 0.5 33 17 15 176 6.5 1.35
07 03 63 NO 22 20
07 04 63 NC G3/4” 40 850 0.5 33 17 20 314 6.5 1.30
07 04 63 NO 22 20
Note: Specify the voltage of the electric coil when ordering. (Example: 07 03 63 NC V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.56
DIRECT DRIVE 3-WAY VACUUM SOLENOID VALVES WITH BISTABLE IMPULSE SOLENOID
PILOT VALVE AND WITH LOW ABSORPTION ELECTRIC COIL
4
Solenoid pilot
valve
R = Pump R = Discharge
A = Use A = Use
P = Discharge P = Pump
A Max flow rate Level of vacuum Reaction time Mouth Cross-section of F Weight
Item abs. mbar msec passage
Ø m3/h min max energ. de-energ. Ø mm2 Ø Kg
07 05 63 NC G1” 90 850 0.5 42 20 25 490 6.5 1.65
07 05 63 NO 28 22
Note: Specify the voltage of the electric coil when ordering. (Example: 07 05 63 NC V24-CC)
The connector is not integral parts of the solenoid valve and, therefore, must be ordered separately (See accessories for solenoid valves).
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.57
SOLENOID VALVES - SPECIAL PRODUCTS UPON REQUEST
MULTI-FUNCTION MODULES WITH BUILT-IN VACUUM SOLENOID VALVES
The needs of technical designers in the packaging sector and in the automation sector in general to have
more vacuum combined with different functions in the smallest possible space has led us to design and
implement this new series of multi-function modules.
Each module has two internal solenoid valves built inside it. Their ducts house the seats for the flow
3D drawings are available on vuototecnica.net
control valves, which can be operated externally by means of special knobs. Various connections made
at different points allow for connection of the module to instruments for reading and checking the level of
vacuum, such as vacuum gauges, vacuum switches, transducers, etc.
There are three modules currently available:
- Module A: The basic module with two integrated 1”1/2 and 1” solenoid valves, two flow regulators and
several additional connections.
- Module B: With two integrated 1/2 "and 1" solenoid valves and two flow regulators. Can be combined with
modules A and C.
- Module C: Module with two integrated 1/2” solenoid valves, a flow regulator and an additional connection.
Can be combined with module A or B.
The combination of modules A, B and C, feasible using special stainless steel tie-rods, allows for the
application of various functions from a single source of vacuum, as well as allowing for the elimination of
numerous pipes and fittings, often causing leaks. The multi-function modules are supplied already tested
to a guaranteed final level of vacuum of 0.5 mbar and perfectly sealed.
The technical characteristics are those of the pneumatically actuated three-way vacuum solenoid valves:
- Servo-control pressure: 6-7 bar; 4-6 bar for version LP, with non-lubricated compressed air, 5 micron
filtration, according to standard ISO 8573-1 class 4
- Operating pressure: from 0.5 to 3000 absolute mbar
- Electric coils: fully plastic-coated in synthetic resin, watertight, insulation class F (up to 155°C) as per
standard VDE, with 3 mm two-terminal electrical connections for connectors in compliance with EN
175301-803
- Protection degree IP 54; IP 65 with connector inserted.
- Tolerance permitted on the nominal voltage value: ± 10%
- Electrical power of the coils: from 1 to 2 W, depending on the electrical voltage
- Temperature of suctioned fluid: from – 5 to + 60°C
The ideal use of these multi-function modules is on vacuum thermoformers and vacuum thermo-welders,
but they are also widely used on packaging and filling machines in the packaging sector and in all those
cases where it is necessary to manage the vacuum at different points and times. Upon request, the
4 modules can be customised and implemented with solenoid valves up to 3” gas. Contact our technical
department for further information.
4.58
SOLENOID VALVES - SPECIAL PRODUCTS UPON REQUEST
MULTI-FUNCTION MODULES WITH BUILT-IN VACUUM SOLENOID VALVES
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
4.59
SOLENOID VALVE ACCESSORIES AND SPARE PARTS
WITH LOW ABSORPTION ELECTRIC COIL
Solenoid pilot valves with built-in low absorption electrical coil
The solenoid valves are small three-way valves, driven by a built-in
electric coil, capable of managing compressed air or vacuum, for driving
solenoid valves.
3D drawings are available on vuototecnica.net
M an u a l
The electric coils of the solenoid pilot valves are fully plastic-coated a c t i va t i o n
in synthetic resin, watertight, insulation class F (up to 155°C) as per
standard VDE, with 3 mm two-terminal electrical connections for
connectors in compliance with EN 175301-803
(ex DIN 43650) - C.
Protection degree IP 54; IP 65 with connector inserted.
Tolerance permitted on the nominal voltage value: ±10%
Tolerance permitted on the frequency value: ±5%
Room temperature: from -10 to +45°C
Fluid temperature: from -10 to +95°C
Electrical power: from 1 to 2 W
BISTABLE IMPULSE SOLENOID PILOT VALVES WITH BUILT-IN LOW ABSORPTION ELECTRICAL COIL
Service Power Electrical voltage Pressure (bar) Weight
Item
ED W Volt min max g
00 07 309 100% 1 12 / DC 0 8 30
00 07 310 100% 1 24 / DC 0 8 30
For solenoid valves item
07 01 53 - 07 02 53 - 07 03 53 - 07 04 53 - 07 05 53 - 07 06 53 - 07 08 53 - 07 09 53
07 03 53 LP - 07 04 53 LP - 07 05 53 LP - 07 06 53 LP
00 07 311 100% 1 12 / DC 0 1 30
00 07 366 100% 1 24 / DC 0 1 30
For solenoid valves item
07 03 63 - 07 04 63 - 07 05 63
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
4.60
SOLENOID VALVE SEALING KIT
WITH LOW ABSORPTION ELECTRIC COILS
Sealing kits are composed of a membrane, shutters and standard
O-rings installed on our compressed air and vacuum three-way
solenoid valves.
In the presence of very hot fluids (up to 250°C) or corrosive fluids,
3D drawings are available on vuototecnica.net
4.62
SUCTION FILTERS
FCL IN-LINE SUCTION FILTERS, WITH PAPER CARTRIDGE PG. 5.01 ÷ 5.02
PAPER FILTERING CARTRIDGES FOR FCL FILTERS PG. 5.02
5
5
3D drawings are available on vuototecnica.net
FCL IN-LINE SUCTION FILTERS, WITH PAPER CARTRIDGE
These small in-line filters retain impurities and very fine dust, interfering
with the flow rate in a negligible manner. Thanks to their reduced size, they
can be directly installed onto vacuum piping, close to the utilities (vacuum
cups, vacuum clamping systems, etc.) for a fractionated filtration and a
Filter
cartridge
Filter
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.01
FCL IN-LINE SUCTION FILTERS, WITH PAPER CARTRIDGE
3D drawings are available on vuototecnica.net
Filter
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.02
FB SUCTION FILTER WITH METAL CARTRIDGE
Filter
cartridge 5
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.03
FB SUCTION FILTER WITH METAL CARTRIDGE
3D drawings are available on vuototecnica.net
M6 hex screw
Filter
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.04
FB SUCTION FILTER WITH METAL CARTRIDGE
Filter
cartridge
Condensation
drain
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.05
FB SUCTION FILTER WITH METAL CARTRIDGE
3D drawings are available on vuototecnica.net
M6 hex screw
Filter
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.06
FB SUCTION FILTER WITH METAL CARTRIDGE
Filter
cartridge
Condensation
drain
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.07
FB SUCTION FILTER WITH METAL CARTRIDGE
3D drawings are available on vuototecnica.net
M8 hex screw
Filter
cartridge
Condensation
drain
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.08
FB SUCTION FILTER WITH METAL CARTRIDGE
Filter
cartridge
Condensation
drain
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.09
FB SUCTION FILTER WITH METAL CARTRIDGE
3D drawings are available on vuototecnica.net
Filter
cartridge
Condensation
drain
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.10
STAINLESS STEEL MESH FILTERING CARTRIDGES FOR FB FILTERS
The cartridges described on this page are suited for FB suction filters.
The standard ones are made with profiled stainless steel mesh with a
filtering degree equal to 60 μ.
Upon request, the same cartridges can be supplied with a filtering
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.11
FC SUCTION FILTERS WITH PAPER CARTRIDGE
These filters have been designed to allow vacuum pumps to operate even in very
dusty environments. Installed onto the pump suction inlet, they are able to retain
fine and impalpable dust interfering with the flow rate in a negligible manner.
The filtering cartridge is made with a special treated paper with a filtering degree
3D drawings are available on vuototecnica.net
Seal
Filter
Seal
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.12
FC SUCTION FILTERS WITH PAPER CARTRIDGE
Filter
Seal
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.13
FC SUCTION FILTERS WITH PAPER CARTRIDGE
3D drawings are available on vuototecnica.net
Seal
Filter
Seal
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.14
FC SUCTION FILTERS WITH PAPER CARTRIDGE
Filter
Seal
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.15
PAPER FILTERING CARTRIDGES FOR FC FILTERS
The cartridges described on this page are suited for FC suction filters.
They are made with a special treated paper with a filtering degree
equal to 5 - 7 μ, which is pleated to increase its surface and is
contained in a double perforated sheet steel enclosure.
3D drawings are available on vuototecnica.net
They are recommended for retaining fine and impalpable dust, but not
in presence of water and oil vapours and condensation.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.16
PAPER FILTERING CARTRIDGES FOR FC FILTERS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.17
FO OIL-BATH SUCTION FILTERS
The main feature of these filters is the ability to retain the smallest and most impalpable
dust particles, without reducing the vacuum pump suction flow rate.
Oil-bath filters are composed of a sheet steel head and container coupled with an
interposed seal and clamped by release clamps.
Inside, besides the oil bowl, there are two steel wool filtering cartridges, one of which is
detachable and washable, while the other is fixed. The release clamps guarantee easy
access for cleaning operations.
They can be used with any kind of oil, even drain oil, as long as it has a minimum
viscosity degree. The ideal oil is the same one used for the pump.
Oil-bath suction filters are not recommended for dry vacuum pumps.
They are currently available for capacities up to 300 m3/h.
Technical features
Operating pressure: from 0.5 to 2000 absolute mbar
Fluid temperature: from -20 to +90 °C
Level of filtration: ≤1 μ
Seal
Fixed
cartridge
Mobile
Oil
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.18
STEEL WOOL FILTERING CARTRIDGES FOR FO FILTERS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.19
FO LONG OPERATION AUTONOMY OIL-BATH SUCTION FILTERS
In presence of fine or impalpable dust, the traditional suction filter would require
a cartridge with a filtering degree so high that, along with reducing its operation
autonomy, it would also reduce the vacuum pump suction flow rate.
Oil-bath suction filters have been studied in order to overcome this problem.
3D drawings are available on vuototecnica.net
The main feature of these filters, in addition to their high autonomy, is their
ability to retain the finest suctioned impalpable dusts without reducing the
suction flow rate of the pump.
Oil-bath filters are composed of a sheet steel head and container coupled with
an interposed seal and clamped by release clamps.
Inside, besides the oil bowl, there are two steel wool filtering cartridges, one of
which is detachable and washable, while the other is fixed. The release clamps
guarantee easy access for cleaning operations.
Two visual indicators allow monitoring of the oil level and the degree of clogging.
They can be used with any kind of oil, even drain oil, as long as it has a minimum
viscosity degree. The ideal oil is the same one used for the pump.
Oil-bath suction filters are not recommended for dry vacuum pumps.
They are currently available for 200 and 300 m3/h capacities.
Technical features
Operating pressure: from 0.5 to 2000 absolute mbar
Temperature of fluid: from -20 to +90°C
Level of filtration: ≤1 μ
Quantity of oil: FO 160 - 6.3 L
FO 300 - 12.5 L
5
Filter
cartridge
Seal
Visual level
indicators
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.20
FS SYPHON SUCTION FILTERS
These filters retain impurities and liquids extracted through vacuum cups or vacuum clamping systems,
preventing them from entering into the vacuum pumps.
They are composed of:
- A transparent Plexiglas cylindrical container with an extractable lid to allow inspection and cleaning
Vacuum
gauge
Seal
Magnetic
Filter sensor 5
cartridge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.21
SYPHON FILTER SYSTEMS WITH AUTOMATIC BY-PASS FS 50 BP and FS 60 BP
The system, composed of two siphon filters, operates initially with suction through filter 1 and with filter 2 excluded. When the suctioned liquid
reaches the float on the level switch, automatically by means of the 1” 1/2 three-way vacuum interception solenoid valve for item FS 50 BP and 2” for
item FS 60 BP, an exchange is made and suction passes through filter 2.
The input of atmospheric air into filter 1 via the ½” three-way solenoid valve installed on its lid, accumulated liquid is allowed to discharge
3D drawings are available on vuototecnica.net
automatically through the check valve with tap on the bottom of the filter. Once liquid has been discharged, after a pre-set time (this operation can be
timed), the solenoid valve returns to its initial position, thus allowing recreation of a vacuum inside the filter through a small flexible hose connected
to the main vacuum piping.
With this arrangement, there will not be any decrease in the level of vacuum for use when the suction exchange will be carried out between the two
filters. This exchange will take place when the liquid reaches the level switch float on filter 2 and, from that moment, the operations described above
will be repeated.
The filter system is composed of:
- 2 Plexiglas siphon filters with aluminium lids and complete with accessories, with a flow rate of 38 L each
- 2 1” 1/2 gas three-way servo-operated vacuum solenoid valves, item 07 06 13 for item FS 50 BP
and 2” gas servo-operated vacuum solenoid valves, item 07 08 13 for item FS 60 BP
- 2 ½” gas three-way servo-operated vacuum solenoid valves, item 07 03 13.
- 4 1” 1/2 gas two-way manual valves for vacuum interception, item 13 07 10 for item FS 50 BP
and 2” gas for vacuum interception, item 13 08 10 for item FS 60 BP
- 2 Manual ½” gas two-way valves, for atmospheric air input, item 13 03 10
- 1 Switchgear enclosed in a special watertight metal box, for single phase electrical voltage Volt 230/ 50 Hz
- 1 Coated profile steel frame to mount all above-described components
The siphon filter system with automatic by-pass is recommended in all those cases in which there is a strong presence of liquid in suction fluids and
where machine shut-down for the discharge of liquids suctioned by traditional siphon filters is not allowed.
Technical features
Operating pressure: from 0.5 to 2000 absolute mbar
Fluid temperature: from -5 to +50°C
Level of filtration: 60 μ
Switchgear
For Ø8 ext. hose
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.22
SPECIAL FILTERS
2FS50BPM1
GAFL01M1
3D drawings are available on vuototecnica.net
5.23
5
FP SERIES FILTERING CARTRIDGE CONTAINERS WITH COMPRESSION SEALING
The containers of the FP series are suited for the filtering cartridges with compression
sealing and are composed of a transparent plastic container and a blue plastic head
screwed together with an interposed seal. The number after the item indicates the
length in inches of the necessary filtering cartridge.
3D drawings are available on vuototecnica.net
4 holes for
Ø 4.2 for fixing
Spanner Item NP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.24
FILTERING CARTRIDGES WITH COMPRESSION SEALING
Seal
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.25
FM SERIES QUICK COUPLING FILTERING CARTRIDGE CONTAINERS
The containers of the FM series are suited for quick coupling filtering cartridges and are composed of a
transparent SAN (Styrene-acrylic nitrile) container and a head with a reinforced polypropylene ring nut,
coupled together with an interposed seal.
The number after the item indicates the length in inches of the necessary filtering cartridge.The cartridge can
3D drawings are available on vuototecnica.net
be chosen in various materials: pleated paper, pleated polypropylene mesh and AISI 304 stainless steel
mesh. The quick coupling filtering cartridges are described on page 5.28, with all the indications regarding
dimensions, materials and filtering degree of each one of them.
Technical features
Operating pressure: from 0.5 to 9000 absolute mbar
Temperature of suctioned fluid: from -10 to 45°C
4 holes for
self-threading screws
Spanner Item NP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.26
FK SERIES QUICK COUPLING FILTERING CARTRIDGE CONTAINERS
The containers of the FK series are suited for quick coupling filtering cartridges and are
composed of a transparent PET (Polyethylene terephthalate) container and a head with
a brass ring nut coupled together with an interposed seal.
The number after the item indicates the length in inches of the necessary filtering
4 holes for
Spanner Item NK
Ø 4.2 for fixing
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
5.27
QUICK COUPLING FILTERING CARTRIDGES
They are produced with different materials that can be identified with
the following abbreviations:
- Series RP. Pleated paper quick coupling filtering cartridge with
double O-ring.
- Series RS. Pleated polypropylene mesh quick coupling filtering
cartridge with double O-ring.
- Series RA. AISI 304 stainless steel mesh quick coupling filtering
cartridge with double O-ring.
The number after the item indicates the length in inches of the
filtering cartridge.
Seal
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
5.28
VACUUM FITTINGS AND HOSES
6
6
3D drawings are available on vuototecnica.net
HOSE ENDS
Hex. C
d A C D E F G H Material Weight
Item
Ø Ø Ø g
RS 1/4” G1/4” 9 17 5 5 18 12 35 nickel-plated brass 20
RS 3/8” G3/8” 13 19 9 5 20 8 33 nickel-plated brass 30
RS 1/2” G1/2” 16 23 12 5 25 10 40 nickel-plated brass 50
RS 3/4” G3/4” 21 28 16 8 35 12 55 nickel-plated brass 90
RS 1” G1” 27 36 22 8 35 12 55 nickel-plated brass 130
RS 1” 1/4 G1” 1/4 35 44 28 10 42 15 67 nickel-plated brass 270
RS 1” 1/2 G1” 1/2 40 50 33 10 45 15 70 nickel-plated brass 320
RS 3” G3” 76 100 66 10 60 30 100 nickel-plated iron 1450
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
6.01
FITTINGS AND CAPS
Hex. C
Bush
MALE FITTING
d A B C D E L Fitting Bush Weight
Item
Ø Ø int. hose Ø material material g
RM M5 M5 5.0 3.5 10 4 10 19.5 tropicalised iron anodised aluminium 6
RM 1/8” G1/8” 7.0 4.5 14 4 13 24.5 anodised aluminium anodised aluminium 6
RM 1/4” G1/4” 8.5 5.0 17 6 15 27.0 anodised aluminium anodised aluminium 10
RM 3/8” G3/8” 10.5 5.0 19 9 20 32.5 anodised aluminium anodised aluminium 18
Hex. C
Fitting Bush
FEMALE FITTING
d A C D E L Fitting Bush Weight
Item
Ø Ø int. hose Ø material material g
RF 1/8” G1/8” 14 14 4 13 27.0 anodised aluminium anodised aluminium 8
RF 1/4” G1/4” 16 17 6 15 30.0 anodised aluminium anodised aluminium 12
RF 3/8” G3/8” 20 19 9 20 32.5 anodised aluminium anodised aluminium 16
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
6.02
FITTINGS AND CAPS
T-FITTING
d A E L Fitting Weight
Item
Ø material g
RT M5 M5 4.5 10 15.0 anodised aluminium 1
RT 1/8” G1/8” 7.0 16 24.0 anodised aluminium 9
RT 1/4” G1/4” 9.0 22 30.0 anodised aluminium 21
RT 3/8” G3/8” 11.0 25 32.5 anodised aluminium 29 6
Hex. C
O-ring
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
6.03
ROTATING QUICK COUPLING FITTINGS
Quick coupling fittings are composed of a jack with hose end connector and a threaded
male coupler which connects itself to the jack.
They are fixed by a ball ring pushed by a spring. A nitrile rubber seal guarantees a perfect
vacuum seal.
3D drawings are available on vuototecnica.net
The structure of this type of fitting allows the two components to rotate freely at a low
speed and to rapidly couple and disconnect by manually acting on the jack reeded ring
nut. These fittings are fully made with brass and are available in various sizes.
The two components of the fittings are quick coupling and are not self-retaining.
These fittings are made entirely of brass and are available in various sizes.
Hose end
Coupler
Hex. C
Sp N
Coupler
Sp T
Sp C
Fitting
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
6.04
COMPRESSED AIR AND VACUUM FLEXIBLE HOSES AND RELATIVE FITTINGS
TPL flexible hoses are made with Polyamide 11 of vegetable derivation and are suited for compressed air
and vacuum for internal diameters up to 9 mm, as well as for compressed air only.
They feature a good flexibility and are lightweight, very low water absorption and excellent mechanical
performance. They also feature an excellent resistance to low and high temperatures, chemical agents,
TPL HOSE
d D Bending Weight Package Material Standard
Item
Ø int. Ø ext. radius g/m m colour
TPL 2 2.5 4 20 8.0 100 polyamide 11 light blue
TPL 4 4.0 6 30 19.5 100 polyamide 11 light blue
TPL 6 6.0 8 40 20.5 100 polyamide 11 light blue
TPL 8 8.0 10 60 24.0 100 polyamide 11 light blue
TPL 9 9.0 12 70 28.0 50 polyamide 11 light blue 6
TPL 12 12.0 15 95 67.0 50 polyamide 11 light blue
TPL 16 16.0 18 130 56.0 50 polyamide 11 light blue
TPL 18 18.0 22 300 133.0 50 polyamide 11 light blue
Operating temperature: -40° / +70°C Other colours upon request
TPR HOSE
d D Bending Weight Package Material Standard
Item
Ø int. Ø ext. radius g/m m colour
TPR 3/8” 12.7 17.8 60 150 30 pvc grey
TPR 1/2” 16.2 21.1 80 170 30 pvc grey
TPR 3/4” 21.3 26.4 105 230 30 pvc grey
TPR 1” 27.0 33.1 135 370 30 pvc grey
TPR 1” 1/4 35.7 41.8 175 500 30 pvc grey
TPR 1” 1/2 40.6 47.8 200 630 30 pvc grey
TPR 2” 51.9 59.8 260 900 30 pvc grey
Operating temperature: -10° / +60 °C
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
6.05
TPR FLEXIBLE HOSE FITTINGS
3D drawings are available on vuototecnica.net
RTPR FITTINGS
d A B C D E G H L Material Colour Weight
Item
Ø Ø g
RTPR 3/8” G3/8” 14.5 8.5 26 12.0 23.5 6 28 46.5 pvc grey 12
RTPR 1/2” G1/2” 14.5 9.0 28 15.5 26.5 7 33 50.0 pvc grey 18
RTPR 3/4” G3/4” 14.0 10.5 35 20.8 26.5 9 38 51.0 pvc grey 26
RTPR 1” G1” 16.0 9.0 41 26.5 32.5 10 44 57.5 pvc grey 36
Operating temperature: -10° / +60 °C
RTPR FITTINGS
d A B D E H L Material Weight
Item
Ø Ø g
RTPR 1” 1/4 G1” 1/4 11 6 34.5 28.5 52 45.5 nickel-plated brass 340
RTPR 1” 1/2 G1” 1/2 14 7 39.5 34.0 60 55.0 nickel-plated brass 530
RTPR 2” G2” 14 7 50.0 33.0 74 54.0 nickel-plated brass 596
Operating temperature: -20° / +60 °C
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
6.06
VACUUM PUMPS AND PUMP SETS
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t 1=
6
V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve relative to the emptying time of a 6-litre volume t : time obtained in the table (sec)
7.01
MEMBRANE VACUUM MINI PUMPS
H 35 M - H 35 M 110 60
3D drawings are available on vuototecnica.net
H 40 DM - H 40 DM 110 60
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.02
MEMBRANE VACUUM MINI PUMPS,
WITH DC MOTOR
The mini pumps on this page are the same as described above,
with a DC motor rather than an AC.
The performances are also almost the same.
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t 1=
6
V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 6-litre volume t : time obtained in the table (sec)
7.03
MEMBRANE VACUUM MINI PUMPS,
WITH DC MOTOR
H 35 M CC - H 35 M 12 CC
3D drawings are available on vuototecnica.net
H 40 DM CC - H 40 DM 12 CC
7
Item H35 M CC H35 M 12 CC H40 DM CC H40 DM 12 CC
Nominal flow rate:
Connection in series l / 1’ 8.5 8.5
Parallel connection l / 1’ = 8.5 + 8.5
Final pressure:
Connection in series mbar abs. 200 60
Parallel connection mbar abs. = 200
Maximum pressure bar 2 2
Motor performance volt 24 VDC 12 VDC 24 VDC 12 VDC
Motor power watt 12 22
Rotation speed g/min-1 3000 3000
Noise level dB(A) ≤ 50 ≤ 50
Max weight Kg 0.62 1.19
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.04
ROTARY VANE VACUUM PUMPS - GENERAL DESCRIPTION
Working principle
The rotor rotates eccentrically inside a stator and it has grooves in
which the vanes move freely and are pushed against the stator inside
Rotor housing
In smaller and more compact pumps, the rotor is cantilevered on the
crankshaft extension (fig.1), while in the versions with high installed 1.
power or with frequent start-ups, the rotor is supported by bearings on
both sides (fig. 2).
In this case, the pump and the electric motor are two independent units
and the two shafts are coupled together by an elastic transmission joint.
2.
Lubrication system
The main lubrication systems used by us are vacuum with oil
recirculation or waste oil for vacuum pumps in the VTL series and an oil
bath for pumps in the RVP series.
In oil recirculation lubrication (fig.1), the oil sucked into the working
chamber through the adjustable oilers that dose the flow is discharged
together with the air sucked into the recovery tank and, through a special 7
filter contained in it, is separated from the air and put back into the cycle.
With disposable oil lubrication (fig.2), the lubrication oil is contained in
a special transparent container, controlled by a magnetic level switch,
and follows the same route previously described but is collected in the
recovery tank without being put back into the cycle. This lubrication
system is recommended when there are water condensates, solvent
vapours or anything else that can pollute the oil in the intake air.
With oil-bath lubrication (fig.3), the oil is sucked into the working
chamber directly from the recovery tank through calibrated pipes that
measure the quantity and is held and separated from the air during
discharge by special dehydrating microfibre cartridges, contained in the 1. 2.
tank itself.
In this lubrication system, the quantity of oil in circulation is significantly
higher than that of the two systems described above. This leads to a
better seal between the stator and the rotor and lower friction between
the rotating and fixed parts, with a resulting increase in the degree of
vacuum, less heating and less noise.
3.
7.05
ROTARY VANE VACUUM PUMPS - GENERAL DESCRIPTION
lubrication.
Use of these pumps is not recommended when the fluid to be suctioned contains
vapours or water or oil condensation.
Cooling
The pump cooling system we use is the surface air type. The heat developed by the
vacuum pump is dispersed from the external, specially finned surface by the fan of
the electric motor on smaller pumps and by a radial fan keyed on the pump shaft on
larger pumps. Pumps with capacities from 100 m3/h upwards are also equipped with
a serpentine radiator (1). In this case, the lubricating oil, passing through the radiator
before entering the working chamber, is cooled by the radial fan, which sucks the cooling
air through the radiator itself, allowing a further reduction of the heat developed by the
pump.
1. 2. 3.
Materials used
The stator and the flanges of the pumps are made of spheroidal cast iron, the
transmission shaft and the rotor are made of carbon steel, while the vanes are in carbon
fibre or glass for lubricated pumps and in graphite for dry pumps.
Electric motors
All vacuum pumps with flow rate up to 21 m3/h can be supplied either with three-phase
or single-phase electric motors; for those with higher flow rates, only three-phase.
All the pumps are equipped as standard with multi-voltage electric motors, according
7
to EC regulations. Upon request, they can be supplied with UL-CSA compliant motors or
with special voltages and frequencies.
The pumps are driven by an electric motor, in compliance with IEC International
Standard 60034 requirements for rotating machines and European Directives for Low
Voltage (LV) 2006/95/EC, for Electromagnetic Compatibility (EMC) 2004/108/EC, for
the limitation of use of hazardous substances RoHS 2011/65/EC and Machine Directive
2006/42/EC for CE marking.
With the exception of electric motors with power lower than 0.75 KW, the efficiency
class corresponds to IE3 = Premium Efficiency, with protection degree IP 55, Tolerance
of nominal Voltage ± 10% and Class of Insulation F.
Certifications
The design and construction of our vacuum pumps comply with European safety
directives. The "CE" mark is in fact reported along with the technical characteristics of
the pumps on all the identification plates and the instructions for use and maintenance
that accompany them are always provided with a Declaration of Compliance with
Machinery Directive 2006/42/EC and subsequent changes.
7.06
VACUUM PUMPS VTL 2 and 4
These small vacuum pumps have a suction flow rate of 2 and 4 m3/h.
They feature a wick lubrication with oil recirculation, while the rotor,
which is cantilevered-fitted on the motor shaft, allows reducing the
overall dimensions to the minimum.
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.07
VACUUM PUMPS VTL 2 and 4
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.08
VACUUM PUMPS VTL 5 and 10
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.09
VACUUM PUMPS VTL 5 and 10
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.10
VACUUM PUMPS VTLP 5 and 10
WITH DISPOSABLE LUBRICATION
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.11
VACUUM PUMPS VTLP 5 and 10
WITH DISPOSABLE LUBRICATION
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.12
VACUUM PUMPS VTL 10/FG, 15/FG and 20/FG
These vacuum pumps have a suction flow rate of 10, 15 and 20 m3/h.
The vacuum lubrication with oil recirculation is adjusted via two oilers
located in correspondence of the support bearings.
The rotor is cantilevered-fitted on the motor shaft and supported by
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.13 -1
VACUUM PUMPS VTL 10/FG, 15/FG and 20/FG
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.14 -1
VACUUM PUMPS VTLP 10/FG, 15/FG and 20/FG,
WITH DISPOSABLE LUBRICATION
These vacuum pumps have a suction flow rate of 10, 15 and 20 m3/h.
The vacuum with disposable oil lubrication is adjusted via two oilers located in
correspondence of the support bearings.
The rotor is cantilevered-fitted on the motor shaft and supported by independent
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.15 -1
VACUUM PUMPS VTLP 10/FG, 15/FG and 20/FG,
WITH DISPOSABLE LUBRICATION
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.16 -1
VACUUM PUMPS VTL 25/FG, 30/FG and 35/FG
These vacuum pumps have a suction flow rate of 25, 30 and 35 m3/h.
The vacuum lubrication with oil recirculation is adjusted via two oilers
located in correspondence of the support bearings.
The rotor is cantilevered-fitted on the motor shaft and supported by
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.17
VACUUM PUMPS VTL 25/FG, 30/FG and 35/FG
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.18
VACUUM PUMPS VTLP 25/FG, 30/FG and 35/FG
WITH DISPOSABLE LUBRICATION
These vacuum pumps have a suction flow rate of 25, 30 and 35 m3/h.
The vacuum with disposable oil lubrication is adjusted via two oilers located in correspondence
of the support bearings.
The rotor is cantilevered-fitted on the motor shaft and supported by independent bearings
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.19
VACUUM PUMPS VTLP 25/FG, 30/FG and 35/FG
WITH DISPOSABLE LUBRICATION
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.20
VACUUM PUMPS VTL 40/G1 - 105/G1
These vacuum pumps have a suction flow rate of 40, 50, 65, 75, 90
and 105 m3/h.
The vacuum lubrication with oil recirculation is adjusted via two oilers
located in correspondence of the support bearings.
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.21
VACUUM PUMPS VTL 40/G1, 50/G1 and 65/G1
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.22
VACUUM PUMPS VTL 75/G1, 90/G1 and 105/G1
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.23
VACUUM PUMPS VTL 75/G1, 90/G1 and 105/G1
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.24
VACUUM PUMPS VTLP 40/G1 - 105/G1
WITH DISPOSABLE LUBRICATION
These vacuum pumps have a suction flow rate of 40, 50, 65, 75, 90 and 105 m3/h.
The vacuum with disposable oil lubrication is adjusted via two oilers located in
correspondence of the support bearings.
The rotor is cantilevered-fitted on the motor shaft and supported by independent
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.25
VACUUM PUMPS VTLP 40/G1, 50/G1 and 65/G1
WITH DISPOSABLE LUBRICATION
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.26
VACUUM PUMPS VTLP 75/G1, 90/G1 and 105/G1
WITH DISPOSABLE LUBRICATION
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.27
VACUUM PUMPS VTLP 75/G1, 90/G1 and 105/G1
WITH DISPOSABLE LUBRICATION
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.28
LUBRICATED ROTARY VANE VACUUM PUMPS, RVP SERIES - GENERAL DESCRIPTION
The pumps in this new series are single-stage, rotary vane and with oil-bath lubrication
with recycling. The implementation of cutting edge construction techniques and the use
of hi-tech, latest generation materials has allowed for the achievement of high standards
of quality, performance, duration and low cost of use. The resulting technical features
7.29
OIL-BATH VACUUM PUMP RVP 15
3D drawings are available on vuototecnica.net
RVP 15
Flow rate Time
RVP 15
Vacuum mbar
Vacuum mbar
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.30
OIL-BATH VACUUM PUMP RVP 15
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.31
OIL-BATH VACUUM PUMP RVP 21
3D drawings are available on vuototecnica.net
RVP 21 RVP 21 Z
Vacuum mbar
Vacuum mbar
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.32
OIL-BATH VACUUM PUMP RVP 21
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.33
OIL-BATH VACUUM PUMP RVP 40
3D drawings are available on vuototecnica.net
Vacuum mbar
Vacuum mbar
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.34
OIL-BATH VACUUM PUMP RVP 40
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.35
OIL-BATH VACUUM PUMP RVP 60
3D drawings are available on vuototecnica.net
Vacuum mbar
Vacuum mbar
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.36
OIL-BATH VACUUM PUMP RVP 60
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.37
OIL-BATH VACUUM PUMP RVP 100
3D drawings are available on vuototecnica.net
Vacuum mbar
Vacuum mbar
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.38
OIL-BATH VACUUM PUMP RVP 100
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.39
OIL-BATH VACUUM PUMPS RVP 160 and RVP 200
3D drawings are available on vuototecnica.net
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.40
OIL-BATH VACUUM PUMPS RVP 160 and RVP 200
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.41
OIL-BATH VACUUM PUMPS RVP 250 and RVP 300
3D drawings are available on vuototecnica.net
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.42
OIL-BATH VACUUM PUMPS RVP 250 and RVP 300
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.43
LUBRICATED VACUUM PUMP
ACCESSORIES AND SPARE PARTS
3D drawings are available on vuototecnica.net
7.44
LUBRICATED VACUUM PUMP
ACCESSORIES AND SPARE PARTS
00 RVP 15 06 1 RVP15
00 RVP 21 06 1 RVP21
00 RVP 40 06 1 RVP40
00 RVP 60 06 1 RVP60
00 RVP 100 06 1 RVP100
00 RVP 160 06 1 RVP160
00 RVP 200 06 1 RVP200
00 RVP 250 06 1 RVP250
00 RVP 300 06 1 RVP300
7.45
LUBRICATED VACUUM PUMP
ACCESSORIES AND SPARE PARTS
3D drawings are available on vuototecnica.net
FC 10 1 VTL 4
VTL 5 - VTLP 5
FC 20 1 VTL 10 - VTLP 10
VTL 10/F - VTLP 10/F
VTL 10/FG - VTLP 10/FG
VTL 15/F - VTLP 15/F
VTL 15/FG - VTLP 15/FG
VTL 20/F - VTLP 20/F
VTL 20/FG - VTLP 20/FG
RVP15
FC RVP21
FC 25 1 VTL 25/FG - VTLP 25/FG
VTL 30/FG - VTLP 30/FG
VTL 35/FG - VTLP 35/FG
FC 30 1 VTL 40/G1 - VTLP 40/G1
VTL 50/G1 - VTLP 50/G1
VTL 65/G1 - VTLP 65/G1
FC 35 1 RVP40
7 RVP60
RVP100
FC 40 1 VTL 75/G1 - VTLP 75/G1
VTL 90/G1 - VTLP 90/G1
FC 50 1 VTL 105/G1 - VTLP 105/G1
FC 60 1 RVP160
RVP200
RVP250
RVP300
7.46
LUBRICATED VACUUM PUMP
ACCESSORIES AND SPARE PARTS
7.47
DRY VACUUM PUMPS VTS 2 and 4
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.48
DRY VACUUM PUMPS VTS 2 and 4
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.49
DRY VACUUM PUMPS VTS 6 and 10
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.50
DRY VACUUM PUMPS VTS 6 and 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.51
DRY VACUUM PUMPS VTS 10/FG - 35/FG
lubrication.
The pump rotor is cantilevered-fitted on the motor shaft and
supported by independent bearings housed in the two pump flanges.
The pump and the electric motor are, therefore, two independent units
and fixed onto a special support and connected to each other via an
elastic transmission joint.
All this allows using standard electric motors, in the shapes and sizes
indicated in the table.
The pump is surface cooled. Heat is dispersed from the outer surface,
suitably finned, by means of a radial fan placed between motor and
pump.
A filter that functions as a silencer is installed on the suction inlet.
We strongly recommend installing a filter on the suction inlet against
possible impurities. These pumps are not recommended when the
fluid to be sucked contains water or oil vapours or condensations.
Also this range of pumps can be supplied with single-phase electric
motors.
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.56
DRY VACUUM PUMPS VTS 10/FG, 15/FG and 20/FG
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.57
DRY VACUUM PUMPS VTS 25/FG, 30/FG and 35/FG
3D drawings are available on vuototecnica.net
t x V1
To calculate the emptying time of a volume of V 1, use the following formula: t1=
100
Curve relative to the flow rate (referring to the suction pressure) V1 : Volume to be emptied ( l )
Curve relative to the flow rate (referring to a 1013 mbar pressure) t1 : time to be calculated (sec)
Curve regarding the emptying time of a 100-litre volume t : time obtained in the table (sec)
7.58
DRY VACUUM PUMPS VTS 25/FG, 30/FG and 35/FG
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = cfm= m3/h x 0.588; inch Hg= mbar x 0.0295; psi= bar x 14.6
25.4 453.6 0.4536
7.59
DRY VACUUM PUMP
ACCESSORIES AND SPARE PARTS
3D drawings are available on vuototecnica.net
7.60
DRY VACUUM PUMP
ACCESSORIES AND SPARE PARTS
FC 10 1 VTS 10
FC 20 1 VTS 10/F
VTS 15/F
VTS 20/F
VTS 10/FG
VTS 15/FG
VTS 20/FG
FC 25 1 VTS 25/F
VTS 25/FG
FC VTS 30/FG
VTS 35/FG
7.61
MINI PUMP SETS - GENERAL DESCRIPTION
Mini pump sets are small independent vacuum-producing units with reduced size.
They are composed of:
- A small welded sheet steel tank with perfect vacuum seal.
- A low-flow rate dry or lubricated rotating vane vacuum pump.
3D drawings are available on vuototecnica.net
- A mini digital vacuum switch for adjusting the maximum level of vacuum.
- A vacuum gauge for reading the level of vacuum.
- Switchgear enclosed in a special casing.
- A manual valve for vacuum interception.
- A cock for condensation drainage.
The level of vacuum, preset via the digital vacuum switch is automatically maintained in
the tank.
Mini pump sets can also be supplied with single-phase or DC electric motors and they
are suited for equipping fixed or mobile working units that require vacuum, such as:
- Trolleys with vacuum cups for fixing and transporting glass and crystals.
- Vacuum clamping systems for ski maintenance, marble processing and for polishing
copper, pewter or silver objects.
- Hoists with vacuum cups for lifting television sets and household appliances for glass
installation in door and window frames, for laying ceramic tiles, for feeding sheet metal
into presses, etc.
7.62
MINI PUMP SETS DO 06V ... and DO 10V ... WITH DRY VACUUM PUMPS
Handle
DO 10V VTS 2 10 VTS 2 3 ~ 230/400-50Hz DO 06 97V 100 180 175 221 360 19.0 FB 10 / FC 10
DO 10V VTS 2 M 10 VTS 2 M 1 ~ 230-50Hz DO 06 98V 100 180 175 221 360 19.2 FB 10 / FC 10
DO 10V VTS 4 10 VTS 4 3 ~ 230/400-50Hz DO 06 97V 100 203 175 231 360 20.5 FB 10 / FC 10
DO 10V VTS 4 M 10 VTS 4 M 1 ~ 230-50Hz DO 06 98V 100 203 175 231 360 20.7 FB 10 / FC 10
DO 10V VTS 6 10 VTS 6 3 ~ 230/400-50Hz DO 06 97V 100 270 175 256 360 25.5 FB 10 / FC 10
DO 10V VTS 6 M 10 VTS 6 M 1 ~ 230-50Hz DO 06 98V 100 270 175 256 360 25.7 FB 10 / FC 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.63
MINI PUMP SETS DO 06V ... and DO 10V ... WITH LUBRICATED VACUUM PUMPS
3D drawings are available on vuototecnica.net
Check valve
Handle
DO 10V VTL 2 10 VTL 2 3 ~ 230/400-50Hz DO 06 97V 100 250 175 238 360 19.4 FB 10 / FC 10
DO 10V VTL 2 M 10 VTL 2 M 1 ~ 230-50Hz DO 06 98V 100 250 175 238 360 19.7 FB 10 / FC 10
DO 10V VTL 4 10 VTL 4 3 ~ 230/400-50Hz DO 06 97V 100 280 175 238 360 21.0 FB 10 / FC 10
DO 10V VTL 4 M 10 VTL 4 M 1 ~ 230-50Hz DO 06 98V 100 280 175 238 360 21.2 FB 10 / FC 10
DO 10V VTL 5 10 VTL 5 3 ~ 230/400-50Hz DO 06 97V 100 260 175 350 360 28.2 FB 10 / FC 10
DO 10V VTL 5 M 10 VTL 5 M 1 ~ 230-50Hz DO 06 98V 100 260 175 350 360 28.7 FB 10 / FC 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.64
MINI PUMP SETS DO 20V ...
Handle
Cock for
Tank condensation drainage
Item 13 02 11
Note: All RVP pumps .. are equipped as standard with an FC filter .. suitable for the size of their suction connection.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.65
HORIZONTAL PUMP SETS - GENERAL DESCRIPTION
As a standard, these pump sets are built with various capacities and they are composed of:
- A horizontal welded sheet steel tank with perfect vacuum seal.
- A rotary vane vacuum pump to be selected according to the required suction
flow rate and level of vacuum.
3D drawings are available on vuototecnica.net
- A digital vacuum switch for adjusting the level of vacuum within which to operate.
- A vacuum gauge for a direct reading of the level of vacuum in the tank.
- A switchgear enclosed in a special plastic casing for tanks from 25 to 50 litres
and in a watertight metal casing for tanks of 100 litres upwards.
- A manual valve for vacuum interception.
- A cock for condensation drainage.
The level of vacuum, preset via the digital vacuum switch is automatically maintained in the tank.
The pump operation can be both continuous or automatic.
Pump sets are normally used for handling particularly heavy or valuable loads since, in case of electricity
failure, they allow the vacuum cups to maintain the grip for a certain amount of time, according to the tank
capacity.
These pump sets are recommended for multi-point applications, to centralise vacuum.
These pump sets offer many advantages in energy consumption, since the pump operates only when
required by the machine.
7.66
HORIZONTAL PUMP SETS DO 25V ...
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.67
HORIZONTAL PUMP SETS DO 100V ...
Vacuum
cut-off valve
Item 13 05 10
Vacuum
cut-off valve
Item 13 05 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.68
HORIZONTAL PUMP SETS DO 300V ...
Vacuum
cut-off valve
Item 13 07 10
Vacuum
cut-off valve
Item 13 08 10
7
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.69
HORIZONTAL PUMP SETS DO 1000V ...
3D drawings are available on vuototecnica.net
Vacuum
cut-off valve
Item 13 09 10
DO 1000V RVP 200 1000 RVP 200 3 ~ 400/690-50Hz DO 100 97V 1615 1250 G3” 443 FC 80
DO 1000V RVP 250 1000 RVP 250 3 ~ 400/690-50Hz DO 100 97V 1615 1250 G3” 448 FC 80
DO 1000V RVP 300 1000 RVP 300 3 ~ 400/690-50Hz DO 100 97V 1615 1250 G3” 464 FC 80
Note: All RVP pumps .. are equipped as standard with an FC filter .. suitable for the size of their suction connection.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.70
HORIZONTAL SAFETY PUMP SETS – GENERAL DESCRIPTION
Safety pump sets have been designed to centralise vacuum in all work environments such as hospitals,
laboratories, etc. where vacuum must be guaranteed 24/7.
They are essentially composed of:
- A horizontal welded sheet steel tank with perfect vacuum seal.
7.71
HORIZONTAL SAFETY PUMP SETS DSO 300V ...
Item 09 05 10 valve
Vacuum gauge
Vacuum
cut-off valve
Item 13 07 10
Vacuum
cut-off valve
Item 13 08 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.72
HORIZONTAL SAFETY PUMP SETS DSO 1000V ...
Vacuum pump
Pump exclusion valve
Item 09 05 10
Vacuum cut-off
valve Item 13 09 10
7
Cock for
condensation
drainage
Item 13 03 11
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.73
VERTICAL PUMP SETS - GENERAL DESCRIPTION
As a standard, these pump sets are built with various capacities and they are composed of:
- A vertical welded sheet steel tank with perfect vacuum seal.
- A rotary vane vacuum pump to be selected according to the required suction
flow rate and level of vacuum.
3D drawings are available on vuototecnica.net
- A digital vacuum switch for adjusting the level of vacuum within which to operate.
- A vacuum gauge for a direct reading of the level of vacuum in the tank.
- Switchgear enclosed in a special metal watertight casing.
- A manual valve for vacuum interception.
- A cock for condensation drainage.
The level of vacuum, preset via the mini vacuum switch is automatically maintained in
the tank. The pump operation can be both continuous or automatic.
The level of vacuum, preset via the mini vacuum switch is automatically maintained in
the tank. The pump operation can be both continuous or automatic. These pump sets
are normally used for interconnecting several vacuum-operated machines and, for safety
reasons, for vacuum handlers since, in case of electricity failure, they allow the vacuum
cups to maintain the grip for an amount of time proportional to the tank capacity.
As for energy consumption, in both cases these pump sets offer many advantages,
since the pump operates only to restore vacuum in the tank within the preset values and
its interventions depend exclusively on the quantity of air that is actually sucked at the
service.
7.74
VERTICAL PUMP SETS DV 150V ...
Vacuum gauge
Vacuum pump Item 09 03 10
Vacuum gauge
Item 09 03 10
Vacuum pump
Switchgear
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.75
VERTICAL PUMP SETS DV 500V ...
Vacuum gauge
3D drawings are available on vuototecnica.net
Item 09 03 10
Switchgear
Vacuum
cut-off valve
Item 13 08 10
Vacuum gauge
Item 09 03 10
Vacuum pump
Switchgear Vacuum
7 cut-off valve
Item 13 09 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.76
VERTICAL SAFETY PUMP SETS – GENERAL DESCRIPTION
Safety pump sets have been designed to centralise vacuum in all work environments such as hospitals,
laboratories, etc. where vacuum must be guaranteed 24/7.
They are essentially composed of:
- A vertical welded sheet steel tank with perfect vacuum seal.
7.77
VERTICAL SAFETY PUMP SETS DSV 150V ..
Vacuum pump
Vacuum gauge
Item 09 03 10
Switchgear
Vacuum
cut-off valve
Item 13 05 10
Cock for condensation
drainage Item 13 05 10
Vacuum pump
Vacuum gauge
Item 09 03 10
Switchgear
Vacuum
cut-off valve
Item 13 08 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.78
VERTICAL SAFETY PUMP SETS DSV 500V ..
Vacuum gauge
Item 09 03 10
Switchgear
Vacuum
cut-off valve
Item 13 08 10
Cock for condensation
drainage Item 13 05 10
Vacuum pump
Vacuum gauge
Item 09 03 10
7
Switchgear
Vacuum
cut-off valve
Item 13 09 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.79
VERTICAL SAFETY PUMP SETS DSV 2000V ..
3D drawings are available on vuototecnica.net
Vacuum
cut-off valve
Item 13 09 10
Pump exclusion valve
Switchgear
Vacuum pump
Vacuum gauge
Item 09 03 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.80
SPECIAL PUMP SET PRODUCTS
DS3V500VRVP100
7.81
SPECIAL PUMP SET PRODUCTS
3D drawings are available on vuototecnica.net
DO50VRVP40
DO500RVP200FS
7.82
SUPPORT FRAMES FOR TWO VACUUM PUMPS
AND SWITCHGEAR
This frame is made with profiled steel and varnished with special
weather-resistant paints.
It is suited for assembling two vacuum pumps and their switchgear.
This frame is made with profiled steel and varnished with special
weather-resistant paints.
It is suited for assembling two vacuum pumps.
Fitted for
Item Weight 2 Pumps
Kg Mod.
00 DSV 18 117 RVP 160 - RVP 200 - RVP 250 - RVP 300
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.83
SUPPORT FRAMES FOR THREE VACUUM PUMPS
AND SWITCHGEAR
This frame is made with profiled steel and varnished with special
weather-resistant paints.
It is suited for assembling three vacuum pumps and their switchgear.
3D drawings are available on vuototecnica.net
This frame is made with profiled steel and varnished with special
weather-resistant paints.
It is suited for assembling three vacuum pumps.
Fixing plates for electrical power
outlets for pumps
Fitted for
Item Weight 3 Pumps
Kg Mod.
00 DSV 22 197 RVP 160 - RVP 200 - RVP 250 - RVP 300
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.84
SUPPORTS FOR SWITCHGEAR
Fitted for
Item Weight A B C D E F G H I switchgear
Kg item
00 DV 16 1.5 300 256 22 300 256 22 3 10 200 DO 100 98V - DO 100 97V
00 DSV 08 5.5 400 380 10 700 502 49 5 10 300 D2V 150 95V - DSO 300 97V
00 DSV 33 7.0 500 480 10 700 602 49 5 10 400 DSO 300 98V - DSV 2000 99V
4 SLOTS
Fitted for
Item Weight A B switchgear
Kg item
00 DSO 07 7.5 850 250 DSO 300 97V
00 DSO 08 9.0 920 430 DSO 300 97V
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.85
VACUUM PUMP AND PUMP SET MANIFOLDS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.86
VACUUM PUMP AND PUMP SET MANIFOLDS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
7.87
MINI PUMP SET SWITCHGEAR
The mini pump set switchgear is enclosed in a special plastic casing. It can automatically manage a vacuum pump with a maximum power of
5.5 KW with AC and can also maintain the level of vacuum in the tank, set with the digital vacuum switch installed on the control panel.
It is equipped with a remote control switch with thermal protection, a fuse, digital vacuum switch, a transformer for low voltage auxiliary
command, a selector for automatic or manual pump operation, an emergency button and signalling lamps.
3D drawings are available on vuototecnica.net
SWITCHGEAR
FOR PUMP SETS WITH ONE PUMP
The pump set switchgear is enclosed in a special watertight metal casing and can manage a vacuum pump with a power up to 7.5 KW as well
as maintain the level of vacuum in the tank, set with the digital vacuum switch.
It is equipped with a remote control switch with thermal protection, fuses, a transformer for low voltage auxiliary command power supply, a line
switch, a changeover switch for the automatic or manual pump operation, an easily-programmable digital vacuum switch suitable for setting
and controlling all vacuum functions, an hour-counter for measuring the actual pump operation time and signalling lamps.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.88
SWITCHGEAR FOR PUMP SETS WITH TWO PUMPS
The pump set switchgear is enclosed in a special watertight metal casing and can manage two vacuum pumps, each with a power up to 7.5
KW as well as maintain the level of vacuum in the tank, set with the digital vacuum switch.
It is equipped with two remote control switches with thermal protection, fuses, a transformer for low voltage auxiliary command power supply,
a line switch, a changeover switches for the automatic or manual pump operation, an easily-programmable digital vacuum switch suitable for
SWITCHGEAR
FOR SAFETY PUMP SET WITH 2 PUMPS
The pump set switchgear, is enclosed in a special watertight metal casing andautomatically manages two vacuum pumps, each with a power up to 7.5
KW and maintains the level of vacuum in the tank, set with the two easily-programmable digital vacuum switches, suitable for setting and controlling all
vacuum functions.
It is equipped with two remote control switches with thermal protection, fuses, a transformer for low voltage auxiliary command power supply, a line
switch, a changeover switches for the automatic or manual pump operation, two digital vacuum switches, two hour-counters for measuring the actual
pump operation time, an alarm siren with acoustic and lit signalling, a key selector for any necessary exclusion of the siren, test buttons and signalling
lamps.
The switchgear is normally provides for the operation of one pump with subsequent automatic insertion of the second one for larger consumptions and
when, for whatever reason, the plant level of vacuum goes under the preset value.
The automatic timed inverter precisely alternates priority pump start-up of the services so that they are subjected to equal mechanical wear. The
switchboard and remote alarm systems operate when the plant level of vacuum is below the set safety value.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.89
SWITCHGEAR FOR SAFETY PUMP SETS WITH THREE PUMPS
The pump set switchgear, is enclosed in a special watertight metal casing andautomatically manages three vacuum pumps, each with a power up to 7.5 KW
and maintains the level of vacuum in the tank, set with the two easily-programmable digital vacuum switches, suitable for setting and controlling all vacuum
functions.
It is equipped with three remote control switches with thermal protection, fuses, a transformer for low voltage auxiliary command power supply, a line switch, a
3D drawings are available on vuototecnica.net
changeover switches for the automatic or manual pump operation, three digital vacuum switches, two hour-counters for measuring the actual pump operation
time, an alarm siren with acoustic and lit signalling, a key selector for any necessary exclusion of the siren, test buttons and signalling lamps. The switchgear is
normally provides for the operation of one pump with subsequent automatic insertion of the other two for larger consumptions and when, for whatever reason,
the plant level of vacuum goes under the preset value.
The automatic timed inverter precisely alternates priority pump start-up of the services so that they are subjected to equal mechanical wear. The switchboard
and remote alarm systems operate when the plant level of vacuum is below the set safety value.
SWITCHGEAR
FOR SAFETY PUMP SET WITH FOUR PUMPS
The safety pump set switchgear is enclosed in a special watertight metal casing and it automatically manages four vacuum pumps, each with
a power up to 7.5 KW, and maintains the level of vacuum in the tank, set with the two easily-programmable digital vacuum switches, suitable
for setting and controlling all vacuum functions. It is equipped with four remote control switches with thermal protection, fuses, a transformer
for low voltage auxiliary command power supply, a line switch, a changeover switches for the automatic or manual pump operation, two digital
vacuum switches, four hour-counters for measuring the actual pump operation time, an alarm siren with acoustic and lit signalling, a key selector
for any necessary exclusion of the siren, test buttons and signalling lamps.
These switchgears normally provide for the operation of two pumps and the subsequent automatic insertion of the other two for larger
consumptions and when, for whatever reason, the plant level of vacuum goes below the preset value.
The automatic timed inverter precisely alternates priority pump start-up of the services so that they are subjected to equal mechanical wear.
The switchboard and remote alarm systems operate when the plant level of vacuum is below the set safety value.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.90
SWITCHGEAR FOR SINGLE PUMP
The need to use the same vacuum pump in various spots in the work environment,
such as, for example, a shipyard, has led us to creating this mobile switchgear that
allows for polarity reversal in presence of current, as well as for time setting pump
operation and the automatic start-up restoration in case of accidental black-out.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.91
SWITCHGEAR EQUIPPED WITH TOUCH SCREEN OPERATOR PANEL AND
PLC FOR PUMP SETS AND SAFETY PUMP SETS WITH TWO OR MORE PUMP
The new electrical equipment consists of a touch screen, which is a special electronic device that is the result of combining a screen and a digitizer that
allow the user to interact with a graphical interface using their fingers or specific objects.
The touch screen operator panels installed on our Pump sets are human machine interface systems, or rather devices that allow people to control our
equipment very easily.
SCHEDULED MAINTENANCE
ALARM MESSAGES
PRODUCTS
LANGUAGES
7.91 -1
SWITCHGEAR EQUIPPED WITH
TOUCH SCREEN OPERATOR PANEL AND PLC FOR PUMP SETS
Pump set switchgear with a 7” touch screen operator panel is able to automatically manage
a vacuum pump with a maximum power of 7.5 KW in AC and can also maintain the level of
vacuum in the tank.All settings are managed by the Operator Panel and PLC. All settings are
managed from the Operator Panel and PLC.
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
7.92 -1
VACUUM PUMP QUESTIONNAIRE Company
Telephone Fax
Dry air Moist air Air with water Air with oil vapours
Aggressive gases Air with abrasive dust
Fluid temperature °C
7
7.93
VACUUM PUMP QUESTIONNAIRE
8) When the pump stops, does the air return in the vacuum system need to be prevented?
Yes No
The seal is ensured by the check valves, whose use is:
3D drawings are available on vuototecnica.net
Does the vacuum need to be maintained for a specific time? (for example, to support a suspended load with vacuum cups, in case of
a blackout) Yes No
If yes, for how long? s
13) Contact
7
%
7.94
VACUUM GENERATORS AND PNEUMATIC PUMP SETS
TABLE REGARDING THE QUANTITY OF AIR SUCKED BY GENERATORS, AT DIFFERENT LEVELS OF VACUUMS PG. 8.01 ÷ 8.02
TABLE REGARDING VACUUM GENERATOR EVACUATION TIME, AT DIFFERENT LEVELS OF VACUUMS PG. 8.03 ÷ 8.04
ADJUSTABLE CONVEYOR VACUUM GENERATORS PVR 100 and PVR 200 PG. 8.113 ÷ 8.114
CARTRIDGE VACUUM GENERATORS PVR 1 and PVR 4 PG. 8.115
3D drawings are available on vuototecnica.net
8
TABLE REGARDING THE QUANTITY OF AIR SUCKED BY GENERATORS,
AT DIFFERENT LEVELS OF VACUUMS
8.01
TABLE REGARDING THE QUANTITY OF AIR SUCKED BY GENERATORS,
AT DIFFERENT LEVELS OF VACUUMS
3D drawings are available on vuototecnica.net
8.02
TABLE REGARDING VACUUM GENERATOR EVACUATION TIME,
AT DIFFERENT LEVELS OF VACUUMS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.05
SINGLE-STAGE VACUUM GENERATORS 15 01 10, 15 01 10 LP and 15 01 15 LP
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
150110 portata FVG5 portata
FVG3 portata
15 01 10 15 01 10 LP 15 01 15 LP
3D drawings are available on vuototecnica.net
0,7 0,7
1,2
0,6 0,6
1
0,5 0,5
Nl/s
Nl/s
0,8
Nl/s
0,4 0,4
FVG3 portata FVG5 portata
0,6
0,3 0,3
Nl/s
0,8
Nl/s
5000 10000
0,2
0 10 20 30 40 50 5000
0,4 60 70 80 -KPa
0,3
15 01 10 6.0 0.9 9000
0,1 0.80 0.66 0.61 0.55 0.44 0.29 4500
0,20.19 0.09 -- 85
4000
0,2
15 01 10 LP 4.0 1.2 8000
0
0.83 0.67 0.63 0.56 0.49 0.414000
0
0.34 0.18 0.08 85
0,1 15 01 15 LP 4.0 2.2 7000 01.3910 1.2230
20 1.11
40 50 1.00
60 70 0.90
80 0.693500 0.44
0 10 0.30
20 30 0.16
40 50 60 8570 80
3000
ms/l
-Kpa -Kpa
0 6000 3000
0 10 20 30 40 50 60 70 80
ms/l
2500
ms/l
150110 temp
Evacuation rates (ms/l =s/m 3
) at different levels of vacuums (-KPa) at2000
4000
optimal supply pressure
FVG3 temp FVG5 temp
1000 3000 1500
6000
15 01 10 2000
10000
15 01 10 LP 1000
5000
15 01 15 LP
0
10 20 30 40 50 60 70 80 1000
9000 500
4500
-Kpa
5000 0
0
8000 4000
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
7000 -Kpa 3500 -Kpa
4000
6000 3000
ms/l
2500
ms/l
3000 5000
ms/l
4000 2000
2000
3000 1500
2000 1000
1000
1000 500
0 0 0
10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 01 10 6.0 0.9 139 278 472 727 1171 1628 2720 4928 -- 85
15 01 10 LP 4.0 1.2 130 260 510 740 1070 1510 2430 4400 8740 85
15 01 15 LP 4.0 2.2 70 160 260 410 620 910 1500 2620 4490 85
8
ACCESSORIES UPON REQUEST
Silencer item SSX 1/4’’
8.06
SINGLE-STAGE VACUUM GENERATOR 15 03 10
8
P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION
Item 15 03 10
Intake air flow rate m /h3
4.8 5 5
Maximum level of vacuum -KPa 62 78 85
Final pressure mbar abs. 380 220 150
Supply pressure bar 4 5 6
Optimal supply pressure bar 6
Air consumption Nl/s 1.1 1.3 1.6
Operating temperature °C -20 / +80
Noise level at
optimal supply pressure dB(A) 79
Weight g 179
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.07
SINGLE-STAGE VACUUM GENERATOR 15 03 10
1,6
3D drawings are available on vuototecnica.net
1,4
1,2
150310 portata
Nl/s
0,8
0,6
1,6
0,4
1,4
0,2
1,2
0
0 10 20 30 40 50 60 70 80
1
-Kpa
Nl/s
0,8
150310 temp
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
0,6
at optimal supply pressure
item bar Nl/s 4500
0,4 0 10 20 30 40 50 60 70 80 -KPa
4000
15 03 10 6.0 1.6 0,2 1.39 1.30 1.15 1.00 0.89 0.77 0.69 0.44 0.04 85
3500
0
3000 0 10 20 30 40 50 60 70 80
-Kpa
Evacuation rates (ms/l 2500
=s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
ms/l
150310 temp
2000
1500
4500
1000
4000
500
3500
0
3000 10 20 30 40 50 60 70 80 85
-Kpa
2500
ms/l
2000
1500
1000
500
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 03 10 6.0 1.6 77 154 261 403 649 902 1506 2730 3876 85
8.08
SINGLE-STAGE VACUUM GENERATORS 15 05 08 SX, 15 05 10 SX and 15 07 10 SX
The operation of these single-stage vacuum generators is also based on the Venturi
principle. It differs from the generators described above for its increased suction flow
rate, lower supply air pressure, lower than 4 bar to obtain the best performance, and for
the SSX silencer ... with high acoustic dampening, installed as standard on the R exhaust
Vacuum
connection
Silencer
Compressed air
connection
Spare parts 15 05 08 SX 15 05 10 SX
Silencer item SSX 3/8” SSX 3/8”
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.09
SINGLE-STAGE VACUUM GENERATORS 15 05 08 SX and 15 05 10 SX
150518SX portata
3D drawings are available on vuototecnica.net
15 05 08 SX 15 05 10 SX
3 4
3,5
2,5
2
2,5
150518SX portata
Nl/s
Nl/s
1,5 2 portata
150510
1,5
1
3 41
0,5
0,5
3,5
2,5
0 30
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
2 -Kpa -Kpa
2,5
Nl/s
Nl/s
ms/l
1000
1000
15 05 08 SX 15 05 10 SX
3000 2500
500
500
2500
2000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
2000
-Kpa -Kpa
1500
ms/l
ms/l
1500
1000
1000
8 500
500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 05 08 SX 3.5 4.3 35 75 120 190 290 490 920 1530 2730 90
15 05 10 SX 3.5 5.5 25 54 90 140 220 320 570 980 2012 90
8.10
SINGLE-STAGE VACUUM GENERATOR 15 07 10 SX
Silencer
Compressed air
connection
Spare parts 15 07 10 SX
Silencer item SSX 1/2”
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.11
SINGLE-STAGE VACUUM GENERATOR 15 07 10 SX
150710SX portata
3D drawings are available on vuototecnica.net
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
4
Nl/s
150710SX portata
1
6
0
5 0 10 20 30 40 50 60 70 80
-Kpa
4
150710SX temp
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
Nl/s
3
1400
item bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
15 07 10 SX 3.5 8.5
2
1200 5.55 5.00 4.44 4.16 3.83 3.00 1.97 1.56 0.85 90
1000
1
800
0
ms/l
0 10 20 30 40 50 60 70 80
600 -Kpa
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
400
150710SX temp
200
1400
0
1200 10 20 30 40 50 60 70 80 85
- Kpa
1000
800
ms/l
600
400
8
200
0
10 20 30 40 50 60 70 80 85
- Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 07 10 SX 3.5 8.5 18 37 62 92 140 210 410 770 1220 90
8.12
SINGLE-STAGE VACUUM GENERATORS VG 03, VG 03 LP and VG 05 LP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.13
SINGLE-STAGE VACUUM GENERATORS VG 03, VG 03 LP and VG 05 LP
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
150110 portata FVG5 portata
FVG3 portata
VG 03 VG 03 LP VG 05 LP
3D drawings are available on vuototecnica.net
0,7 0,7
1,2
0,6 0,6
1
0,5 0,5
Nl/s
Nl/s
0,8
Nl/s
0,4 0,4
FVG3 portata FVG5 portata
0,6
0,3 0,3
150110 portata
0,4
0,2 0,2
0,9 1,6
0,1 0,2
0,1 0,8 1,4
0,9
0 0
0,7 0
0,8 0 10 20 30 40 50 60 70 80 1,2 0 10 20 30 40 50 60 70 80
0 10 20 30 40 50 60 70 80
-Kpa 0,6 -Kpa -Kpa
0,7 1
150110 temp
0,5
0,6
Nl/s
0,8
Nl/s
0,4 Air flow rate (Nl/s) at differentFVG5levels of vacuums (-KPa) Max vacuum
0,5 Generator Supp. press. Air consumption temp
FVG3 temp
6000 at optimal supply pressure 0,6
Nl/s
0,2
10000
0 10 20 30 40 500,4 60 70 80 -KPa
5000 5000
0,3
VG 03 6.0 0.9 9000
0,1 0.80 0.66 0.61 0.55 0.44 0.29
0,2
4500 0.19 0.09 -- 85
0,2
4000 VG 03 LP 4.0 1.2 8000
0
0.83 0.67 0.63 0.56 0.49 0.41
4000
0
0.34 0.18 0.08 85
0,1 VG 05 LP 4.0 2.2 7000
0 1.39
10 201.2230 1.1150
40 1.00 70
60 0.90
80 0.69
3500
00.4410 0.3030
20 0.1650
40 60 85
70 80
-Kpa -Kpa
3000
ms/l
0
6000 3000
0 10 20 30 40 50 60 70 80
-Kpa
Evacuation rates (ms/l =s/m5000
) at different levels of vacuums (-KPa) at optimal
ms/l
3 2500 supply pressure
ms/l
2000
150110 temp FVG3 4000temp FVG5 temp
2000
VG 03 VG 03 LP VG 05 LP
1000 3000 1500
2500
ms/l
3000 5000
ms/l
4000 2000
2000
3000 1500
2000 1000
1000
1000 500
0 0 0
10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
VG 03 6.0 0.9 139 278 472 727 1171 1628 2720 4928 -- 85
VG 03 LP 4.0 1.2 130 260 510 740 1070 1510 2430 4400 8740 85
VG 05 LP 4.0 2.2 70 160 260 410 620 910 1500 2620 4490 85
8
ACCESSORIES UPON REQUEST
Silencer item SSX 3/8’’ R
8.14
SINGLE-STAGE VACUUM GENERATORS
WITH EJECTOR 15 02 10, 15 02 10 LP, 15 02 15 LP and 15 04 10
This single-stage vacuum generator operation is based on the
Venturi principle. When the generator is supplied with compressed
air in P, the vacuum will be generated at connection U and the
supply air with the suctioned air will be discharged in R. During the
Spare parts 15 02 10 15 02 10 LP 15 02 15 LP
Sealing kit item 00 15 500 00 15 500 00 15 500
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.15
SINGLE-STAGE VACUUM GENERATORS
WITH EJECTOR 15 02 10, 15 02 10 LP and 15 02 15 LP
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
150210 portata
FVG3 portata FVG5 portata
15 02 10 15 02 10 LP 15 02 15 LP
3D drawings are available on vuototecnica.net
0,7 0,7
1,2
0,6 0,6
1
0,5 0,5
Nl/s
0,8
Nl/s
Nl/s
0,4 0,4
FVG3 portata FVG5 portata
150210 portata 0,6
0,3 0,3
0,4
0,2 0,2
0,9 1,6
0,8
0 0
0,7 0
0 10 20 30 40 50 60 70 80 1,2 0 10 20 30 40 50 60 70 80
0 10 20 30 40 50 60 70 80
0,7 -Kpa 0,6 -Kpa -Kpa
1
0,6 0,5
150210 temp
Nl/s
0,8
Nl/s
0,5
0,4 Air flow rate (Nl/s) at different FVG5
levelstemp
of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
FVG3 temp
Nl/s
0,3 10000
0,2
0 10 20 30 40 50 5000
0,4 60 70 80 -KPa
5000
0,2 15 02 10 6.0 0.9 9000
0,1 0.80 0.66 0.61 0.55 0.44 0.294500
0,2 0.19 0.09 -- 85
0,1 15 02 10 LP 4.0 1.2 8000
0
0.83 0.67 0.63 0.56 0.49 0.414000
0
0.34 0.18 0.08 85
4000
0
15 02 15 LP 4.0 2.2 7000
01.3910 1.2230
20 1.11
40 50 1.00
60 70 0.90
80 0.693500 0.44
0 10 0.30
20 30 0.16
40 50 60 8570 80
-Kpa -Kpa
0 10 20 30 40 50 60 70 80
6000 3000
ms/l
3000 -Kpa
ms/l
Evacuation rates (ms/l =s/m5000
3
) at different levels of vacuums (-KPa) at optimal
2500 supply pressure
ms/l
150210 temp
2000 FVG3 4000temp FVG5 temp
2000
1000 15 02 10 3000
10000
15 02 10 LP 1500
5000
15 02 15 LP
6000 2000 1000
9000
1000 4500
500
0
5000 10 20 30 40 50 60 70 80 8000
0 4000
0
-Kpa 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
7000 3500
4000 -Kpa -Kpa
6000 3000
ms/l
ms/l
2500
ms/l
3000 5000
4000 2000
2000
3000 1500
2000 1000
1000
1000 500
0 0 0
10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 02 10 6.0 0.9 139 278 472 727 1171 1628 2720 4928 -- 85
15 02 10 LP 4.0 1.2 130 260 510 740 1070 1510 2430 4400 8740 85
15 02 15 LP 4.0 2.2 70 160 260 410 620 910 1500 2620 4490 85
8.16
SINGLE-STAGE VACUUM GENERATOR WITH EJECTOR 15 04 10
Spare parts 15 04 10
Sealing kit item 00 15 501
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.17
SINGLE-STAGE VACUUM GENERATOR WITH EJECTOR 15 04 10
150410 portata
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
3D drawings are available on vuototecnica.net
1,6
1,4
150410 portata
1,2
1,6
Nl/s
0,8
1,4
0,6
1,2
0,4
1
0,2
Nl/s
0,8
0
0 10 20 30 40 50 60 70 80
0,6 -Kpa
0,4
150410 temp Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
0,2 at optimal supply pressure
item bar Nl/s
0 0 10 20 30 40 50 60 70 80 -KPa
0 10 20 30 40 50 60 70 80
15 04 10 6.0 1.64500 1.39 1.30 -Kpa 1.15 1.00 0.89 0.77 0.69 0.44 0.04 85
4000
150410 temp
2500
4500
ms/l
2000
4000
1500
3500
1000
3000
500
2500
ms/l
0
2000 10 20 30 40 50 60 70 80 85
-Kpa
1500
1000
500
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 04 10 6.0 1.6 77 154 261 403 649 902 1506 2730 3876 85
8.18
SINGLE-STAGE VACUUM GENERATOR WITH EJECTOR 15 06 08 SX and 15 06 10 SX
Vacuum
connection
Screw-type flow
regulator Blow off
Compressed air
connection
Spare parts 15 06 08 SX 15 06 10 SX
Sealing kit item 00 15 414 00 15 414
Silencer item SSX 3/8” SSX 3/8”
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.19
SINGLE-STAGE VACUUM GENERATOR WITH EJECTOR 15 06 08 SX and 15 06 10 SX
MSVE 8 portata
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
3D drawings are available on vuototecnica.net
150610 portata
3
15 06 08 SX 15 06 10 SX
4
2,5 3,5
3
2
2,5
Nl/s
MSVE 8 portata
1,5
Nl/s
2
150610 portata
1,5
1
1
3 4
0,5
0,5
3,5
2,5
0 0
0 10 20 30 40 50 60 70 80 3 0 10 20 30 40 50 60 70 80 88
-Kpa -Kpa
2
2,5
Nl/s
Nl/s
1,5 150610
2 temp
MSVE 8 temp Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
1,5
item1 bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
3000 2500
1
15 06 08 SX 3.5 4.3 2.44 2.27 2.11 1.94 1.72 1.46 0.98 0.50 0.04 90
0,5
15 06 10 SX 3.5 5.5 3.47 3.24 2.86 0,5 2.49 2.22 1.92 1.72 1.20 0.65 90
2500
2000
0 0
2000 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 88
-Kpa -Kpa
1500
ms/l
1500
ms/l
15 06 08 SX 15 06 10 SX
3000 500
2500
500
2500
0 0
2000
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 88
-Kpa -Kpa
2000
1500
ms/l
ms/l
1500
1000
1000
8 500
500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 88
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
15 06 08 SX 3.5 4.3 35 75 120 190 290 490 920 1530 2730 90
15 06 10 SX 3.5 5.5 25 54 90 140 220 320 570 980 2012 90
8.20
SINGLE-STAGE VACUUM GENERATORS WITH EJECTOR FVG 3 and FVG 5
2 M4
fixing holes
2 M5
fixing holes
Silencer
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.21
SINGLE-STAGE VACUUM GENERATORS WITH EJECTOR FVG 3 and FVG 5
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
3D drawings are available on vuototecnica.net
0,9
FVG 3 1,6
FVG 5
0,8 1,4
0,7
1,2
0,6
1
0,5
Nl/s
0,8
Nl/s
0,9 0,4
1,6
0,2
0,8
0,1 0,2
1,4
0,7
0 0
1,2
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
0,6 -Kpa -Kpa
1
0,5
Nl/s
0,8
Nl/s
0,4
FVG3 temp AirFVG5
flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption temp
0,6
0,3 at optimal supply pressure
item bar Nl/s
0 10 20 0,4 30 40 50 60 70 80 -KPa
0,2
10000 5000
FVG 3 4.0 1.2 0.83 0.67 0.63 0.56 0.49 0.41 0.34 0.18 0.08 85
0,2
FVG
0,15
9000 4.0 2.2 1.39 1.22 1.114500 1.00 0.90 0.69 0.44 0.30 0.16 85
0
8000 0
4000
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
7000 -Kpa 3500 -Kpa
6000 3000
ms/l
5000
vacuums (-KPa) at optimal supply pressure
FVG3 temp FVG5 temp
4000 2000
3000
10000
FVG 3 1500
5000
FVG 5
2000 1000
9000 4500
1000 500
8000 4000
0 0
7000 10 20 30 40 50 60 70 80 85 3500 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
6000 3000
ms/l
2500
ms/l
5000
4000 2000
3000 1500
8 2000 1000
1000 500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
FVG 3 4.0 1.2 130 260 510 740 1070 1510 2430 4400 8740 85
FVG 5 4.0 2.2 70 160 260 410 620 910 1500 2620 4490 85
8.22
SINGLE-STAGE VACUUM GENERATORS WITH EJECTOR FVG 8 and FVG 12
2 M4 fixing holes
2 M5
fixing holes
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.21-1
8.21
SINGLE-STAGE VACUUM GENERATORS WITH EJECTOR FVG 8 and FVG 12
150518SX portata
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
3D drawings are available on vuototecnica.net
150510 portata
FVG 8 FVG 12
3 4
3,5
2,5
2
2,5
150518SX portata
Nl/s
Nl/s
1,5 2 portata
150510
1,5
1
3 41
0,5
0,5
3,5
2,5
0 30
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
2 -Kpa -Kpa
2,5
Nl/s
Nl/s
ms/l
1000
1000
FVG 8 FVG 12
3000 2500
500
500
2500
2000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
2000
-Kpa -Kpa
1500
ms/l
ms/l
1500
1000
1000
8 500
500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
FVG 8 3.5 4.3 35 75 120 190 290 490 920 1530 2730 90
FVG 12 3.5 5.5 25 54 90 140 220 320 570 980 2012 90
8.22-1
8.22
IN-LINE SINGLE-STAGE VACUUM GENERATOR PVP 1
This new range of vacuum generators also makes use of the Venturi
principle.
Their distinctive feature compared with traditional vacuum generators
are the two air and vacuum supply connections located in-line on the
Sp17
Sp17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.23
IN-LINE SINGLE-STAGE VACUUM GENERATOR PVP 1
3D drawings are available on vuototecnica.net
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
PVP1 portata
0,3
0,25
0,2
Nl/s
PVP1 portata
0,15
0,1
0,3
0,05
0,25
0
0,2
0 10 20 30 40 50 60 70 80
-Kpa
Nl/s
0,15
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air 0,1
consumption
PVP1 temp 25000 at optimal supply pressure
item bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
PVP 1 5.0 0,050.45 0.27 0.25 0.22 0.18 0.12 0.07 0.06 0.03 -- 85
20000
0
0 10 20 30 40 50 60 70 80
15000
-Kpa
Evacuation rates (ms/l =s/m ) at different levels of vacuums (-KPa) at optimal supply pressure
3
ms/l
10000
5000
20000
0
10 20 30 40 50 60 70 80 85
15000 -Kpa
ms/l
10000
8 5000
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 1 5.0 0.45 393 786 1336 2057 3312 4605 7690 13935 19787 85
8.24
IN-LINE SINGLE-STAGE VACUUM GENERATORS GV 1, GV 2 and GV 3
Hex. 17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.25
IN-LINE SINGLE-STAGE VACUUM GENERATORS GV 1, GV 2 and GV 3
3D drawings are available on vuototecnica.net
GV (Nl/s)portata
Air flow rate at different level of vacuum (-KPa) at optimal supply pressure
0,3
0,25
GV portata
0,2
0,3
0,15
Nl/s
0,25
0,1
0,2
0,05
0,15
Nl/s
0
0 10 20 30 40 50 60 70 80
-Kpa
0,1
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air0,05
consumption
GV temp at optimal supply pressure
item bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
0
GV1 - GV2 - GV3 5.0 0.45 0 10
0.27
20
0.23
30
0.20 50 0.1760
40
0.13
70
0.06
80
0.05 0.03 -- 85
25000 -Kpa
20000
GV (ms/ltemp
Evacuation rates =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
15000
ms/l
25000
10000
20000
5000
15000
ms/l
0
10 20 30 40 50 60 70 80 85
10000
-Kpa
8 5000
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
GV1 - GV2 - GV3 5.0 0.45 394 788 1339 2063 3322 4617 7711 13973 19841 85
8.26
SINGLE-STAGE VACUUM GENERATORS PVP 05, PVP 2 and PVP 3
With their extremely reduced size and high performance, these single-
stage vacuum generators operate making use of the Venturi principle.
Supplying the generator with compressed air in P, vacuum will be
generated at connection U, while both the supply and the sucked air will
8
P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION
Item PVP 05
Intake air flow rate m /h3
0.36 0.42 0.42 0.47 0.50 0.50
Maximum level of vacuum -KPa 22 33 42 48 61 82
Final pressure mbar abs. 780 670 580 520 390 180
Supply pressure bar 1 2 3 4 5 6
Optimal supply pressure bar 6
Air consumption Nl/s 0.13 0.20 0.27 0.34 0.40 0.50
Operating temperature °C -20 / +80
Noise level at
optimal supply pressure dB(A) 70
Weight g 14
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.27
SINGLE-STAGE VACUUM GENERATOR PVP 05
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
PVP 05 portata
3D drawings are available on vuototecnica.net
0,14
0,12
0,1
0,08
PVP 05 portata
Nl/s
0,14
0,06
0,12
0,04
0,1
0,02
0,08
0
Nl/s
0 10 20 30 40 50 60 70
0,06 -Kpa
0,04 Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
PVP 05 temp
at optimal supply pressure
item bar Nl/s
30000
0,02
0 10 20 30 40 50 60 70 80 -KPa
PVP 05 6.0 0.5 0 0.13 0.11 0.10 0.08 0.06 0.03 0.02 0.01 -- 82
25000 0 10 20 30 40 50 60 70
-Kpa
PVP 05 temp
15000
30000
10000
25000
5000
20000
0
ms/l
15000 10 20 30 40 50 60 70 80
-Kpa
10000
5000
0
10 20 30 40 50 60 70 80
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 -KPa
PVP 05 6.0 0.5 786 1572 2678 4126 6644 9210 15420 27870 82
8
ACCESSORIES UPON REQUEST
Silencer filter item FB 1
8.28
SINGLE-STAGE VACUUM GENERATOR PVP 2
8
P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION
Item PVP 2
Intake air flow rate m /h3
2.8 2.9 3.0
Maximum level of vacuum -KPa 60 70 85
Final pressure mbar abs. 400 300 150
Supply pressure bar 4 5 6
Optimal supply pressure bar 6
Air consumption Nl/s 0.7 0.8 0.9
Operating temperature °C -20 / +80
Noise level at
optimal supply pressure dB(A) 78
Weight g 70
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.29
SINGLE-STAGE VACUUM GENERATOR PVP 2
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
PVP 2 portata
3D drawings are available on vuototecnica.net
0,9
PVP 2 portata
0,8
0,7
0,9
0,6
0,8
0,5
0,7
Nl/s
0,4
0,6
0,3
Nl/s 0,5
0,2
0,4
0,1
0,3
0
0,2
0 10 20 30 40 50 60 70 80
-Kpa
0,1
0
0 10 20 Air30flow40
rate (Nl/s)
50 at different
60 70 levels of vacuums (-KPa)
80 Max vacuum
Generator Supp. press. Air consumption
-Kpa at optimal supply pressure
item bar PVP 2Nl/s temp
0 10 20 30 40 50 60 70 80 -KPa
PVP 2 6.0 0.9 0.83 0.70 0.65 0.52 0.37 0.23 0.13 0.07 -- 85
PVP 2 temp
7000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
6000
7000
5000
6000
4000
ms/l
5000
3000
4000
2000
ms/l
3000
1000
2000
0
10 20 30 40 50 60 70 80 85
1000 -Kpa
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 2 6.0 0.9 128 257 438 675 1087 1511 2523 4572 6492 85
8
ACCESSORIES UPON REQUEST
Silencer item SSX 1/8’’
8.30
SINGLE-STAGE VACUUM GENERATOR PVP 3
8
P=COMPRESSED AIR CONNECTION R=EXHAUST U=VACUUM CONNECTION
Item PVP 3
Intake air flow rate m /h3
3.4 3.5 3.7
Maximum level of vacuum -KPa 60 70 85
Final pressure mbar abs. 400 300 150
Supply pressure bar 4 5 6
Optimal supply pressure bar 6
Air consumption Nl/s 1.0 1.1 1.3
Operating temperature °C -20 / +80
Noise level at
optimal supply pressure dB(A) 80
Weight g 100
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.31
SINGLE-STAGE VACUUM GENERATOR PVP 3
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
PVP 3 portata
3D drawings are available on vuototecnica.net
1,2
PVP 3 portata
1
1,2
0,8
1
Nl/s
0,6
0,8
0,4
Nl/s
0,6
0,2
0,4
0
0 10 20 30 40 50 60 70 80
0,2
-Kpa
0
Air30flow 40
rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. AirPVP
consumption
3 0
temp 10 20 50 60 70 80
-Kpa at optimal supply pressure
item bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
PVP 3 6.0 PVP 31.3 temp 1.03 0.82 0.72 0.61 0.41 0.24 0.15 0.08 -- 85
6000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
5000
6000
4000
5000
ms/l
3000
4000
2000
ms/l
3000
1000
2000
0
10 20 30 40 50 60 70 80 85
1000
-Kpa
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 3 6.0 1.3 104 207 353 544 857 1217 2033 3684 5232 85
8
ACCESSORIES UPON REQUEST
Silencer item SSX 1/8’’
8.32
SINGLE-STAGE VACUUM GENERATORS PVP 2 M, PVP 2 MM1,
PVP 2 MM2 and PVP 2 MM3
The vacuum generators on this page are based on the same Venturi
principle of those previously described and provide the same technical
performance. They however differ in their structure.
The vacuum connection U is in fact threaded to allow for assembly
Item
Item
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.33
SINGLE-STAGE VACUUM GENERATORS PVP 2 M, PVP 2 MM1, PVP 2 MM2 and PVP 2 MM3
PVP 2 M
Air flow rate (Nl/s) at differentportata
level of vacuum (-KPa) at optimal supply pressure
0,9
3D drawings are available on vuototecnica.net
0,8
0,7
0,6
0,5
Nl/s
0,4
PVP 2 M portata
0,3
0,9
0,2
0,8
0,1
0,7
0
0,6
0 10 20 30 40 50 60 70 80
-Kpa
0,5
Nl/s
0,4
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
PVP
0,3 2 M temp at optimal supply pressure
item bar Nl/s
0,2
7000
0 10 20 30 40 50 60 70 80 -KPa
PVP 2 M 6.0 0,9 0,1 0.83 0.70 0.65 0.52 0.37 0.23 0.13 0.07 -- 85
PVP 2 MM1 6.0 0,9 6000 0.83 0.70 0.65 0.52 0.37 0.23 0.13 0.07 -- 85
0
PVP 2 MM2 6.0 0,9 5000 0 0.83
10 20 0.70
30 0.65 50
40 0.52
60 70 0.37
80 0.23 0.13 0.07 -- 85
-Kpa
PVP 2 MM3 6.0 0,9 0.83 0.70 0.65 0.52 0.37 0.23 0.13 0.07 -- 85
4000
ms/l
7000
2000
6000
1000
5000
0
10 20 30 40 50 60 70 80 85
4000 -Kpa
ms/l
3000
2000
1000
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 2 M 6.0 0,9 128 257 438 675 1087 1511 2523 4572 6492 85
PVP 2 MM1 6.0 0,9 128 257 438 675 1087 1511 2523 4572 6492 85
PVP 2 MM2 6.0 0,9 128 257 438 675 1087 1511 2523 4572 6492 85
PVP 2 MM3 6.0 0,9 128 257 438 675 1087 1511 2523 4572 6492 85
8.34
SINGLE-STAGE VACUUM GENERATORS PVP 7 SX / SXLP,
PVP 14 SX / SXLP and PVP 18 SX / SXLP
Vacuum generators PVP ... SX/SXLP, operate
making use of the previously described Venturi
principle.
A special new generation silencer installed on
Additional vacuum
connection
Vacuum Silencer
gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.35
SINGLE-STAGE VACUUM GENERATORS PVP 7 SX / SXLP,
PVP 14 SX / SXLP and PVP 18 SX / SXLP
portata Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
3D drawings are available on vuototecnica.net
PVP 7 SX
PVP 7 SXLP
portata
3,5
2,5 5
3
2 4
2,5
Nl/s
Nl/s
1,5
Nl/s
2 3
1,5
1 2
1
0,5 1
0,5
0 0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 7 SX -Kpa PVP 14 SX -Kpa PVP 18 SX -Kpa
portata
PVP 7 SXLP PVP 14 SXLP PVP 18 SXLP
PVP 7 SX
temp
PVP 7 SXLP
temp
PVP 7 SX temp
PVP 7 SXLP PVP 14 SX
PVP 14 SXLP 2000
PVP 18 SX
3 portata
Air flow rate (Nl/s) at different levels1600
of vacuums (-KPa)
PVP 18 SXLP Max vacuum
Generator Supp. press. Air consumption
1800
3000
portata
at optimal supply pressure
PVP 18 SX
6
2,5 item bar PVP 14 SX
Nl/s 1600
4
PVP 18 SXLP
1400
PVP 14 SXLP
0 10 20 30 40 50 60 70 80 -KPa
1400 1200
2500 3,5 5
2 PVP 7 SX 6.0 3.2 1200
2.58 2.38 2.19 2.02 1.44 0.97 0.86 0.54 0.05 85
PVP 14 SX 6.0 4.8 3 3.75 3.46 3.19 2.95 2.19 1.47
1000
1.29 0.80 0.07 85
ms/l
2000 1000 4
1,5 PVP 18 SX 6.0 6.4 5.00 4.62 4.25 3.93 2.92 1.97 1.75 1.10 0.10 85
ms/l Nl/s
Nl/s ms/l
800
2,5
800
1500 3
600
PVP 7 SXLP 3.0 4.5 600
2.44 2.25 2.07 1.91 1.42 0.95 0.84 0.52 0.04 88
Nl/s
1 2
1000PVP 14 SXLP 3.0 6.9 3.77 3.48 3.20 2.96 2.20 1.48 1.31 0.82 0.07 88
400 400
1,5 2
0,5
PVP 18 SXLP 3.0 8.6 200 4.86 4.48 4.12 3.80 2.82 1.90
200
1.68 1.05 0.09 88
1
500 0 1
0 10 20 30 40 50 60 70 80 85 0
0 10 20 30 40 50 60 70 80 0,5 PVP 14 SX -Kpa 10 20 30 40 50 60 70 80 85
0 PVP 7 SX -Kpa PVP 14 SXLP 0 PVP 18 SX -Kpa
10 PVP
20 7 SXLP
30 40 50 60 70 80 85 0 0 PVP
1018 SXLP
20 30 40 50 60 70 80
PVP 7 SX Evacuation
-Kpa rates (ms/l =s/m3) at0 different
10 20 levels
30 40of vacuums
50 60 70 (-KPa)
80 at optimal supply pressure
-Kpa PVP 18 SX
temp
PVP 7 SXLP PVP 14 SX -Kpa PVP 18 SXLP
PVP 7 SX PVP 14 SXLP
PVP 7 SXLP
temp
temp
3000
PVP 7 SX PVP 7 SXLP PVP 14 SX
2000
PVP 14 SX PVP 14 SXLP PVP 18 SX PVP 18 SX PVP 18 SXLP
PVP 14 SXLP PVP 18 SXLP 1600
1800
1400
2500
1600
1200
1400
2000
1200 1000
ms/l
ms/l
1000
ms/l
1500 800
800
600
1000
600
400
400
500
200 200
0 0 0
8 10 20
PVP 7 SX
30 40 50
-Kpa
60 70 80 85 10 20
PVP 14 SX
30 40 50
-Kpa
60 70 80 85 10 20 30
PVP 18 SX
40
-Kpa
50 60 70 80 85
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 7 SX 6.0 3.2 33 70 115 173 289 492 796 1418 2532 85
PVP 14 SX 6.0 4.8 23 49 80 120 200 340 550 980 1750 85
PVP 18 SX 6.0 6.4 18 38 62 93 155 264 420 750 1340 85
PVP 7 SXLP 3.0 4.5 34 74 121 200 315 487 760 1348 2410 88
PVP 14 SXLP 3.0 6.9 24 52 85 140 220 340 530 940 1680 88
PVP 18 SXLP 3.0 8.6 18 39 64 105 165 255 398 706 1260 88
8.36
ACCESSORIES FOR SINGLE-STAGE VACUUM GENERATORS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.37
FIXING SUPPORTS FOR SINGLE-STAGE VACUUM GENERATORS
The supports illustrated and described on this page are made in anodised aluminium as a
standard but, upon request, they can be supplied in the stainless steel version.
These supports are for fixing the multi-stage vacuum generators to the machine via a
cylindrical slotted pin or a ball pin housed in the machine itself.
3D drawings are available on vuototecnica.net
They are suited for robotic gripping systems and they allow for easy vacuum generator
installation on the profiles used in the automotive sector.
By Material Weight
Item
generators g
FCH 01 PVP 2 aluminium 60
PVP 3
FCH 01 INOX PVP 2 stainless steel 180
PVP 3
By Material Weight
Item
generators g
8
FCH 02 15 01 10 aluminium 72
15 02 10
15 03 10
15 04 10
15 05 10
15 06 10
15 07 10
FCH 02 INOX 15 01 10 stainless steel 220
15 02 10
15 03 10
15 04 10
15 05 10
15 06 10
15 07 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
8.38
FIXING SUPPORTS FOR SINGLE-STAGE VACUUM GENERATORS
By Material Weight
Item
generators g
8
FCH 04 15 01 10 aluminium 52
15 02 10
15 03 10
15 04 10
15 05 10
15 06 10
15 07 10
FCH 04 INOX 15 01 10 stainless steel 156
15 02 10
15 03 10
15 04 10
15 05 10
15 06 10
15 07 10
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
8.39
SINGLE-STAGE AND MULTI-FUNCTION VACUUM GENERATORS, MSVE SERIES
The vacuum generators of this new series can fully drive a negative pressure gripping system. By means of coaxial
shutters, the original compressed air supply system feeds large quantities of air to both the ejectors and the ejection
system, thereby ensuring faster gripping and release of the load. These vacuum generators are equipped with single-
stage ejectors, are powered by low pressure (max. 4 bar), and feature an extremely high emptying speed in
3D drawings are available on vuototecnica.net
relation to their suction flow rate. All this allows for increasingly faster high-performance work
cycles. Two micro solenoid valves manage the compressed air supply to the vacuum
ejector and adjustable discharge blow off. The intensity and duration of the latter are
managed through a screw-type flow regulator. The check valve built into the suction
connector maintains the vacuum in the event of a power outage. A digital vacuum
switch, equipped with a display and commutation LED, manages the compressed
air supply and provides a signal to start a cycle under safety conditions. An anodised
aluminium distributor with vacuum connectors has an integrated suction filter that can be
easily inspected. By activating the compressed air power micro solenoid valve, the generator
creates vacuum for use. As soon as the set maximum value is reached, the digital vacuum switch acts on
the electric coil of the micro solenoid valve and stops the air supply, reactivating it when the vacuum falls
below the minimum level. 2 Solenoid valves
Besides maintaining the vacuum level within set safety values (hysteresis), this modulation with manual drive
allows for considerable compressed air savings. A second signal from the vacuum switch
(also adjustable and independent with respect to the first) can be used to start
the cycle when the vacuum level reached is suitable for use. Once the
work cycle is completed, the micro solenoid valve that supplies
compressed air to the generator is deactivated while, at the
same time, the ejection solenoid valve is activated for quick
restoration of the atmospheric pressure upon use. The
MSVE vacuum generators can be installed in any position Silencer
and are suitable for suction gripping systems, handling
metal sheets, glass, marble, ceramics, plastic, cardboard, Screw-type
wood, etc. and, in particular, for the industrial robotics flow regulator
Blow off
sector, where equipment with excellent performance and
limited weight and bulk are increasingly required.
0,9
MSVE 3 MSVE 5
1,6
0,8
1,4
0,7
1,2
0,6
1
0,5 FVG5 portata
FVG3 portata
Nl/s
Nl/s
0,8
0,4
0,6
1,6
0,9
0,3
0,8 0,4
1,4
0,2
0,7
0,1 0,2
1,2
0,60 0
1
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
0,5 -Kpa -Kpa
Nl/s
0,8
Nl/s
0,4
0,6
0,3
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator
FVG3 temp Supp. press. Air consumption FVG5 temp
at
0,4optimal supply pressure
item
0,2 bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
0,2
0,1
MSVE
10000 3 4.0 1.2 0.83 0.67 0.63 50000.56 0.49 0.41 0.34 0.18 0.08 85
MSVE
0 5
9000 4.0 2.2 1.39 1.22 1.11 0 1.00
4500
0.90 0.69 0.44 0.30 0.16 85
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
8000 -Kpa 4000 -Kpa
7000 3500
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
6000 3000
FVG3 temp FVG5 temp
ms/l
ms/l
5000 2500
2500
ms/l
5000
4000 2000
3000 1500
2000 1000
1000 500 8
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MSVE 3 4.0 1.2 130 260 510 740 1070 1510 2430 4400 8740 85
MSVE 5 4.0 2.2 70 160 260 410 620 910 1500 2620 4490 85
8.41
SINGLE-STAGE AND MULTI-FUNCTION VACUUM GENERATORS MSVE 8 and MSVE 12
3D drawings are available on vuototecnica.net
Screw-type
flow regulator
Blow off
3
MSVE 8 4
MSVE 12
3,5
2,5
3
2
MSVE 8 portata
2,5
Nl/s
Nl/s
1,5 MSVE 12 portata
2
1,5
3
1
2,5 4
0,5
0,5
3,5
2
0 0
0 10 20 30 40 50 60 70 80 3 0 10 20 30 40 50 60 70 80
-Kpa -Kpa
Nl/s
1,5
2,5
MSVE 12 temp
Nl/s
1
2
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
MSVE 8 temp Generator Supp. press. Air consumption
at optimal supply pressure
2500
item bar Nl/s 1,5
0 10 20 30 40 50 60 70 80 -KPa
0,5
3000
MSVE 8 3.5 4.3 2.44 2.27 2.11 1 1.94
2000
1.72 1.46 0.98 0.50 0.04 90
MSVE 12 3.5 5.5 3.47 2.88 2.72 2.50 2.27 1.83 1.16 0.60 0.05 90
0 0,5
2500 0 10 20 30 40 50 60 70 80
-Kpa 1500
0
2000 0 10 20 30 40 50 60 70 80
ms/l
-Kpa
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
1000
ms/l
1000
MSVE 8 500
MSVE 12
3000 2500
500
2500 0
2000
10 20 30 40 50 60 70 80 85
-Kpa
0
2000
10 20 30 40 50 60 70 80 85
1500
-Kpa
ms/l
ms/l
1500
1000
1000
500
500
8
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MSVE 8 3.5 4.3 35 75 120 190 290 490 920 1530 2730 90
MSVE 12 3.5 5.5 27 57 100 150 230 350 740 1200 2150 90
8.43
SINGLE-STAGE AND MULTI-FUNCTION VACUUM GENERATORS MSVE 20
3D drawings are available on vuototecnica.net
Screw-type
flow regulator
Blow off
150710SX portata
4
Nl/s
150710SX portata
1
6
0
5 0 10 20 30 40 50 60 70 80
-Kpa
4
150710SX temp
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
Nl/s
3
1400
item bar Nl/s
0 10 20 30 40 50 60 70 80 -KPa
MSVE 20 4 82
1200 5.55 5.00 4.44 4.16 3.83 3.00 1.97 1.56 0.85 90
1000
1
800
0
ms/l
0 10 20 30 40 50 60 70 80
600 -Kpa
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
400
150710SX temp
200
1400
0
1200 10 20 30 40 50 60 70 80 85
- Kpa
1000
800
ms/l
600
400
8
200
0
10 20 30 40 50 60 70 80 85
- Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MSVE 20 4 8 18 37 62 92 140 210 410 770 1220 90
8.45
ACCESSORIES AND SPARE PARTS FOR MULTI-STAGE AND MULTI-FUNCTION VACUUM
GENERATORS, SERIES MSVE
3D drawings are available on vuototecnica.net
Blowing Red
Blue
va lve
Connector for blowing sol enoid va lve
Suction
va lve
Connector for
vacuum switch
8
Digital
vacuum switch
8.45-1
ACCESSORIES AND SPARE PARTS FOR MULTI-STAGE AND
MULTI-FUNCTION VACUUM GENERATORS, SERIES MSVE
WHITE
DIGITAL OUTPUT (+24) DIGITAL VACUUM SWITCH
PNP ITEM 121010 (C)
BROWN
POSITIVE POLE +24
Item Description
00 15 203 Set of cables with built-in energy saving device for connection to:
- Digital vacuum switch
- NC micro supply solenoid valve
- NC micro ejection solenoid valve
Cable length - 5 m
Connector
Item Description
00 15 157 Connector with LED for micro solenoid valves
Item Description
00 12 20 Electrical connection cable with M8 - 4 pin axial connector 8
for digital vacuum switch length 5 m
Item Description
00 12 21 Electrical connection cable with M8 - 4 pin radial connector
for digital vacuum switch length 5 m
8.46-1
ACCESSORIES AND SPARE PARTS FOR MULTI-STAGE AND
MULTI-FUNCTION VACUUM GENERATORS, SERIES MSVE
3D drawings are available on vuototecnica.net
M an u a l
a c t i va t i o n
Item Description
00 07 304 NO micro solenoid valves with built-in low absorption electrical coil and interface
M an u a l
a c t i va t i o n
Item Description
00 15 447 NC micro solenoid valves with built-in low absorption electrical coil and interface
8
Digital vacuum switch
Item Description
12 30 10 Digital vacuum switch
8.47-1
SINGLE-STAGE AND MULTI-FUNCTION VACUUM GENERATORS SERIES AVG - GENERAL
DESCRIPTION
These generators are independent vacuum units capable of driving a vacuum gripping system They have
been specially designed for the AUTOMOTIVE sector and they are equipped with single ejectors that, given
the same flow rate as the multi-ejector generators, allow for a quicker grip.
They are provided as standard with a built-in pneumatic energy-saving device.
3D drawings are available on vuototecnica.net
They are composed of an anodised aluminium mono-block structure, inside of which are installed the
ejectors, the servo-controlled slide valve for the compressed air supply and are contained the vacuum
chambers as well as the various connections.
The following are instead installed on the outside:
- A bistable impulse solenoid valve for controlling the slide valve.
- A solenoid valve for blowing the ejected compressed air.
- A flow regulator for dosing the ejected compressed air.
- Two silencers for removing noise from the ejected air.
- An aluminium manifold provided with vacuum connections with built-in:
• A pneumatic vacuum switch for managing the compressed air supply according to the set level of
vacuum (energy saving).
• A check valve for maintaining the vacuum in case of electricity or compressed air failure.
• A suction filter, easy to inspect through the transparent polycarbonate lid.
OPERATION
By providing an electric impulse to the two-position solenoid valve, the compressed air supply slide valve
will be activated and vacuum will be created at the application. Once the preset maximum value has been
reached, the pneumatic vacuum switch acts on the servo-controlled valve and interrupts the compressed
air supply, restoring it when the value returns below the minimum value.
Besides maintaining the level of vacuum within preset safety values, this modulation also allows a
considerable saving of compressed air and occurs even in the absence of electricity. Once the work cycle
is completed, the power supply solenoid valve is deactivated by means of an electrical pulse while, at the
same time, the ejection solenoid valve is activated for quick restoration of the atmospheric pressure of use.
AVG vacuum generators are fitted for the installation of a digital vacuum switch. Also these vacuum
generators can be installed in any position.
SECTORS OF USE
AVG vacuum generators are suitable for suction gripping systems, for the handling of metal sheets, glass,
marble, ceramics, plastic, cardboard, wood, etc. and, in particular, for the AUTOMOTIVE sector, where
equipment with excellent performance and limited size and weight are increasingly required.
8.46
SINGLE-STAGE AND MULTI-FUNCTION VACUUM GENERATORS AVG 18 and AVG 25
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.47
SINGLE-STAGE AND MULTI-FUNCTION VACUUM GENERATORS AVG 18 and AVG 25
AVG 18 AVG 25
3D drawings are available on vuototecnica.net
6 8
7
AVG18
5 portata AVG25 portata
4
5
6 8
Nl/s
Nl/s
3 4
7
5
3
2 6
4 2
5
1
1
Nl/s
Nl/s
3 4
0 0
0 10 20 30 40 50 60 70 80 3 0 10 20 30 40 50 60 70 80
2 -Kpa
-Kpa
2
1 AVG25 tempi
AVG18 temp Air flow rate (Nl/s)1 at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item0 bar Nl/s 0
0 10 20 30 40 50 60 70 0
80 10 20 30 0 40
10 2050 30 60
40 50 70 60 80
70 80 -KPa
-Kpa -Kpa
AVG 18 6.0 6.4 4.83 4.58 4.04 3.58 2.72 1.90 1.68 1.07 0.10 85
AVG 25 6.0 9.6 7.00 6.63 5.86 5.18 3.94 2.76 2.44 1.54 0.15 85
AVG25 tempi
AVG18
1200 temp 900
800
1000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
700
800
1200
AVG 18 600
AVG 25
900
500
ms/l
ms/l
600
800
400
1000
400 700
300
800 600
200
200
500
100
ms/l
ms/l
600
400
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
400 300
-Kpa -Kpa
200
200
100
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
8
AVG 18 6.0 6.4 22 44 75 115 185 258 430 798 1107 85
AVG 25 6.0 9.6 15 30 52 80 128 178 297 538 764 85
8.48
ACCESSORIES AND SPARE PARTS FOR SINGLE-STAGE AND MULTI-FUNCTION VACUUM
GENERATORS, SERIES AVG
Supply solenoid
valve
Silencer
Pneumatic
vacuum switch
8.49
ACCESSORIES AND SPARE PARTS FOR SINGLE-STAGE AND MULTI-FUNCTION VACUUM
GENERATORS, SERIES AVG
3D drawings are available on vuototecnica.net
Item Description
12 05 11 * Digital micro vacuum switch
* Complete the code indicating the electrical type of the output: P = PNP; N = NPN
Connector
Item Description
00 15 157 Connector with LED for solenoid valves
Item Description
00 15 297 Bistable supply solenoid valve
NC solenoid valve
Item Description
00 15 175 NC blowing solenoid valve
8
Silencer
Item Description
SSX 3/4” R Exhaust silencer
8.50
MULTI-STAGE VACUUM GENERATORS - GENERAL DESCRIPTION
Our multi-stage vacuum generators produce a maximum vacuum of 90%, equal to a final
level of vacuum of 100 mbar abs., with different suction capacities. They operate by use
of compressed air from 1 to 6 bar.
Working principle
8.51
MULTI-STAGE VACUUM GENERATORS SERIES M
Spare parts M3 M7
Sealing kit and reed valves item 00 KIT M 3 00 KIT M 7
Exhaust silencer item 00 15 150 00 15 150
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.52
MULTI-STAGE VACUUM GENERATORS M 3 and M 7
M3 portata
M7 portata
M3 M7
1,2
M3 M7
2
1,8
1
1,6
M3 portata 1,4
0,8
M7 portata
1,2
Nl/s
Nl/s
0,6
M3 1
1,2 0,8 M7
0,4 2
0,6
1 1,8
0,4
0,2
1,6
0,2
0,8
1,4
0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
1,2
-Kpa -Kpa
Nl/s
0,6 Nl/s
1
M3 tempi
M7 tempi
0,4 0,8
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption 0,6
at optimal supply pressure
item
0,2 bar Nl/s
0 10 20 0,4 30 40 50 60 70 80 -KPa
M7
M3
0
5.0 M3 0.8 1.00 0.83 0.61 0,20.34
7000
0.18 0.12 0.10 0.07 0.03 85
M7 0 10 5.0
20 30 40 501.4 60 70 1.7280 1.28 0.89 0
0.50 0.37 0.27 0.16 0.11 0.05 85
12000
-Kpa 0 10 20 30 40 50 60 70 80
6000 -Kpa
M3 tempi
10000
5000M7 tempi
8000
Evacuation rates (ms/l =s/m3) at different levels of4000
vacuums (-KPa) at optimal supply pressure
ms/l
ms/l
6000
M3 3000 M7
M3 7000
M7
12000
4000 2000
6000
10000 1000
2000
5000
0
8000
0 10 20 30 40 50 60 70 80 85
10 20 30 40 50 60 70 80 85 4000 -Kpa
ms/l
ms/l
6000 -Kpa
3000
4000
2000
2000
8
1000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
M3 5.0 0.8 106 244 491 969 1642 2398 4004 7128 10122 85
M7 5.0 1.4 61 142 285 563 954 1394 2328 4144 5885 85
8.53
MULTI-STAGE VACUUM GENERATORS M 10, M 14 and M 18
3D drawings are available on vuototecnica.net
Spare parts M 10 M 14 M 18
Sealing kit and reed valves item 00 KIT M 10 00 KIT M 14 00 KIT M 18
Exhaust silencer item N°2 00 15 150 N°2 00 15 150 N°3 00 15 150
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.54
MULTI-STAGE VACUUM GENERATORS M 10, M 14 and M 18
3
MM10
10 4
MM14
14 6
MM1818
3,5
2,5 5
3
2 4
2,5
1,5 Nl/s 2 3
Nl/s
Nl/s
1,5
1 2
1
M18 portata
0,5 1
0,5
M10 portata M14 portata
0 0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
-Kpa -Kpa M18
-Kpa
M10 M14 6
M10 temp M18 temp
3 4 temp
M14
5
3,5
2,5
Air flowM14
3
M10 4
rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
2 Generator Supp. press. Air consumption M18
4500
3500
2,5 at optimal supply pressure
item bar Nl/s 3
Nl/s
0 10 20 30 40 50
2500
60 70 80 -KPa
Nl/s
1,5 2
Nl/s
4000 3000
0,5
ms/l
1500 0
2000
ms/l
0 0 10 20 30 40 50 60 70 80
0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 1000 -Kpa
1500
-Kpa 1000
-Kpa M18 temp
1000
M10 temp 3
) at different levels of vacuums (-KPa) at500optimal supply pressure
Evacuation rates (ms/l =s/m500
500 M14 temp
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
0
-Kpa -Kpa 10 20 30 40 50 60 70 80 85
4500
MM10
10 3500
MM14
14 2500
M18
M 18
-Kpa
4000
3000
2000
3500
2500
3000
1500
2000
2500
ms/l
ms/l
ms/l
2000 1500
1000
1500
1000
1000 500
500
500
8
0 0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
M 10 5.0 1.9 40 93 188 371 629 918 1534 2731 3878 85
M 14 5.0 2.5 30 69 140 276 469 685 1144 2036 2892 85
M 18 5.0 3.6 21 48 98 193 327 478 799 1423 2020 85
8.55
MULTI-STAGE VACUUM GENERATORS SERIES M.. SSX
These vacuum generators share the same technical features as the others of the M
series described above. Their distinctive feature is their silent operation.
In fact, along with the built-in silencer, they also have an external SSX silencer for a
further noise reduction.
3D drawings are available on vuototecnica.net
These generators are particularly recommended in work environments where the noise
level must be kept within very low values.
Silencer
Intake air flow rate m3/h 3.0 3.4 3.6 5.4 5.8 6.2
Maximum level of vacuum -KPa 62 82 85 62 82 85
Final pressure mbar abs. 380 180 150 380 180 150
Supply pressure bar 3 4 5 3 4 5
Optimal supply pressure bar 5 5
Air consumption Nl/s 0.5 0.7 0.8 0.8 1.2 1.4
Operating temperature °C -10 / +80 -10 / +80
Noise level at
optimal supply pressure dB(A) 52 58
8
Weight g 109 111
A 24.5 25.5
B 9 10
C 4.5 4.5
E Ø 20 29
F 11 12
G Ø G1/4” G3/8”
H 74.5 97.5
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.56
MULTI-STAGE VACUUM GENERATORS M 3 SSX and M 7 SSX
M3 SSX M7 SSX
M 3 SSX M 7 SSX
1,2 2
1,8
1
1,6
1,4
0,8
1,2
Nl/s
0,6 1
Nl/s
M3 SSX portata
M7 SSX
0,8 portata
0,4
M3 SSX 0,6
1,2 0,4
M7 SSX
0,2
2
0,2
1 1,8
0 0
0 10 20 30 40 50 60 70 80 1,6 0 10 20 30 40 50 60 70 80
-Kpa -Kpa
0,8 1,4
M7 SSX
1,2 temp
Nl/s
M30,6
SSX temp
1
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Nl/s
8000
4000
M7 SSX temp
M3 SSX temp
Evacuation rates (ms/l =s/m ) at different levels of vacuums (-KPa) at optimal supply pressure
3
ms/l
ms/l
6000 3000
4000 2000
M3 SSX M7 SSX
M 3 SSX 1000
M 7 SSX
12000 7000
2000
0
6000
10000 10 20 30 40 50 60 70 80 85
0
10 20 30 40 50 60 70 80 85 -Kpa
-Kpa 5000
8000
4000
ms/l
6000
ms/l
3000
4000
2000
2000
8
1000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
M 3 SSX 5.0 0.8 106 244 491 969 1642 2398 4004 7128 10122 85
M 7 SSX 5.0 1.4 61 142 285 563 954 1394 2328 4144 5885 85
8.57
MULTI-STAGE VACUUM GENERATORS M 10 SSX, M 14 SSX and M 18 SSX
3D drawings are available on vuototecnica.net
Silencer
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.58
MULTI-STAGE VACUUM GENERATORS M 10 SSX, M 14 SSX and M 18 SSX
3
M M10 SSX
10 SSX MM14 SSX
14 SSX 6
MM18
18 SSX
SSX
4
3,5
2,5 5
2 4
2,5
Nl/s
Nl/s
Nl/s
1,5 2 3
1,5
1 2
0,5 1
0,5
M14 SSX portata M18 SSX portata
M10 SSX portata
0 0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
M10-KpaSSX M14-KpaSSX M18-KpaSSX
3 4 6
M18 SSX tempi
M10 SSX tempi M14 SSX tempi
3,5
2,5 5
3
2
Air flow rate (Nl/s) at different levels of4 vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
2,5
M10 SSX M14 SSXat optimal supply pressure M18 SSX
item bar Nl/s
Nl/s
Nl/s
1,5
Nl/s
2 3
4500 3500 0 10 20 30 40 50
2500 60 70 80 -KPa
1,5
4000
1 M 10 SSX 5.0 1.9 3000 2.61 2.00 1.55 0.80 0.64 0.502 0.29 0.19 0.09 85
3500 M 14 SSX 5.0 2.5 1 3.50 2.33 1.72 1.00 0.89 0.67
2000 0.35 0.24 0.11 85
0,5 M 18 SSX 5.0 3.6 2500 5.00 3.50 2.78 2.02 1.02 0.751 0.44 0.30 0.14 85
3000 0,5
1500
2000
2500
0 0 0
ms/l
ms/l
ms/l
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
2000 -Kpa 1500 -Kpa -Kpa
1000
1500 M18 SSX tempi
M10 SSX tempi M14 SSX
1000 tempi
1000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
500
500
500
0 0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
10 20 30
M10
40
SSX
50 60 70 80 85
4500
M 10 SSX-Kpa
3500
M14-KpaSSX
M 14 SSX 2500
MM18
18 SSX
SSX
-Kpa
4000
3000
2000
3500
2500
3000
1500
2500 2000
ms/l
ms/l
ms/l
2000 1500
1000
1500
1000
1000
500
500
500 8
0 0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
M 10 SSX 5.0 1.9 40 93 188 371 629 918 1534 2731 3878 85
M 14 SSX 5.0 2.5 30 69 140 276 469 685 1144 2036 2892 85
M 18 SSX 5.0 3.6 21 48 98 193 327 478 799 1423 2020 85
8.59
FIXING SUPPORTS FOR MULTI-STAGE VACUUM GENERATORS, SERIES M
The supports illustrated and described on this page are made in anodised aluminium as
a standard but, upon request, they can be supplied in the stainless steel version.
These supports are for fixing the multi-stage vacuum generators of the series M to the
machine via a cylindrical slotted pin or a ball pin housed in the machine itself.
3D drawings are available on vuototecnica.net
They are suited for robotic gripping systems and they allow for easy vacuum generator
installation on the profiles used in the automotive sector.
By Material Weight
Item
generators g
00 FCH 23 M 3 - M 7 - M 10 - M 14 - M 18 aluminium 63
00 FCH 22 M 3 - M 7 - M 10 - M 14 - M 18 stainless steel 191
By Material Weight
Item
generators g
00 FCH 13 M 3 - M 7 - M 10 - M 14 - M 18 aluminium 85
00 FCH 12 M 3 - M 7 - M 10 - M 14 - M 18 stainless steel 256
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
8.60
MULTI-STAGE AND MULTI-FUNCTION VACUUM GENERATORS SERIES MVG - GENERAL
DESCRIPTION
These generators are true independent vacuum units that can control an entire vacuum
gripping system. Their distinctive features are their compact size and great suction flow
rate.
They are composed of a mono-block anodised aluminium structure onto which are
8.61
MULTI-STAGE AND MULTI-FUNCTION VACUUM GENERATORS MVG 3 and MVG 7
3D drawings are available on vuototecnica.net
Screw-type
flow regulator
Blow off
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.62
MULTI-STAGE AND MULTI-FUNCTION VACUUM GENERATORS MVG 3 and MVG 7
MVG3 portata
MVG7 portata
Air flow rate (Nl/s) at different level of vacuum (-KPa) at optimal supply pressure
MVG 3 MVG 7
MVG 3 MVG 7
MVG3
0,9 portata 1,8
MVG7 portata
0,8 1,6
0,7
MVG 3 1,4 MVG 7
1
0,6 2
1,2
Nl/s
Nl/s
0,9
0,5 1,81
0,8
0,4 1,6
0,8
0,7
0,3 1,4
0,6
0,6
0,2 1,2
0,4
Nl/s
Nl/s
0,5
0,1 1
0,2
0,4
0 0,80
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
0,3 -Kpa 0,6 -Kpa
0,2 0,4
MVG7 temp
MVG3 temp Air flow rate (Nl/s)0,2at different levels of vacuums (-KPa) Max vacuum
Generator
0,1
Supp. press. Air consumption
at optimal supply pressure
item 0 bar Nl/s 0
0 10 20 30 40 50 60 70 80 0 10 20 30 0 4010 2050 30 60
40 50 70 60 80
70 80 -KPa
-Kpa -Kpa
MVG 3 5.0 0.8 0.89 0.69 0.41 0.23 0.18 0.12 0.10 0.07 0.03 85
MVG 3 MVG 70.11
MVG 7 5.0 1.3 1.83 1.44 1.11 0.63
MVG7 0.41
temp 0.25 0.16 0.05 85
MVG3 temp
12000 6000
10000 5000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
MVG 3 MVG 7
8000
12000
MVG 3 4000
6000
MVG 7
ms/l
ms/l
6000 3000
10000 5000
4000 2000
8000 4000
2000 1000
ms/l
ms/l
6000 3000
0 0
4000 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
2000
-Kpa -Kpa
2000 1000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MVG 3 5.0 0.8 119 274 552 1088 1845 2694 4499 8009 11373 85
MVG 7 5.0 1.3 58 133 268 529 897 1310 2188 3895 5531 85
8
ACCESSORIES AND SPARE PARTS UPON REQUEST
Item MVG 3 MVG 7
Sealing kit and reed valves item 00 KIT MVG 3 00 KIT MVG 7
Exhaust silencer item 00 15 150
Electrical connection cable with axial connector, for vacuum switch item 00 12 20
Electrical connection cable with radial connector, for vacuum switch item 00 12 21
Set of electrical connection cables, with built-in
NO energy saving device and connectors item 00 15 202
Set of electrical connection cables, with built-in
NC energy saving device and connectors item 00 15 203
Digital vacuum switch item 12 10 10
NO supply solenoid valve item 00 15 436
NC supply solenoid valve item 00 15 437
8.63
MULTI-STAGE AND MULTI-FUNCTION VACUUM GENERATORS MVG 10 and MVG 14
3D drawings are available on vuototecnica.net
Screw-type
flow regulator
Blow off
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.64
MULTI-STAGE AND MULTI-FUNCTION VACUUM GENERATORS MVG 10 and MVG 14
MVG10 portata
Air flow rate (Nl/s) at different level of vacuum (-KPa)
MVG14 at optimal supply pressure
portata
MVG 10 MVG 14
MVG 10 MVG 14
MVG10 portata
3,5
2,5 MVG14 portata
MVG 10 3 MVG 14
2
3 2,5
4
Nl/s
1,5
Nl/s
2
3,5
2,5
1,5
3
1
2
1
2,5
0,5
0,5
Nl/s
1,5
Nl/s
2
0 0
1,5
1 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
-Kpa -Kpa
1
0,5
MVG10 temp
Air flow rate (Nl/s)0,5at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal
MVG14 tempsupply pressure
item 0 bar Nl/s 0
0 10 20 30 40 50 60 70 80 0 10 20 30 0 4010 2050 30 60
40 50 70 60 80
70 80 -KPa
-Kpa -Kpa
MVG 10 5.0 1.7 2.55 1.85 1.30 0.75 0.64 0.48 0.30
MVG 140.20 0.09 85
MVG 14 5.0
MVG 10 2.1 3.40 2.45 1.84 1.05 0.88 0.61 0.36 0.24 0.11 85
MVG10 temp
4000
3000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
3500
MVG 10 2500
MVG 14
3000
4500
MVG 10 3500
MVG 14
2500 2000
ms/l
ms/l
4000
2000 3000
1500
3500
1500 2500
3000 1000
1000
2500 2000
500
500
ms/l
ms/l
2000 1500
0 0
1500 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa 1000 -Kpa
1000
500
500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MVG 10 5.0 1.7 41 95 192 379 642 938 1567 2790 3962 85
MVG 14 5.0 2.1 31 71 144 284 482 704 1175 2092 2971 85
8
ACCESSORIES AND SPARE PARTS UPON REQUEST
Item MVG 10 MVG 14
Sealing kit and reed valves item 00 KIT MVG 10 00 KIT MVG 14
Exhaust silencer item N°2 00 15 150
Electrical connection cable with axial connector, for vacuum switch item 00 12 20
Electrical connection cable with radial connector, for vacuum switch item 00 12 21
Set of electrical connection cables, with built-in
NO energy saving device and connectors item 00 15 202
Set of electrical connection cables, with built-in
NC energy saving device and connectors item 00 15 203
Digital vacuum switch item 12 10 10
NO supply solenoid valve item 00 15 436
NC supply solenoid valve item 00 15 437
8.65
ACCESSORIES AND SPARE PARTS FOR MULTI-STAGE AND MULTI-FUNCTION VACUUM
GENERATORS, SERIES MVG
Blowing
3D drawings are available on vuototecnica.net
Connector for
vacuum switch
Digital
vacuum switch
WHITE
DIGITAL OUTPUT (+24) DIGITAL VACUUM SWITCH
PNP ITEM 121010
BROWN
POSITIVE POLE +24
Item Description
00 15 202 Set of cables with built-in energy saving device for connection to:
- Digital vacuum switch
- NO micro supply solenoid valve
- NC micro ejection solenoid valve
Cable length - 5 m
8.66
ACCESSORIES AND SPARE PARTS FOR MULTI-STAGE AND
MULTI-FUNCTION VACUUM GENERATORS, SERIES MVG
WHITE
DIGITAL OUTPUT (+24) DIGITAL VACUUM SWITCH
PNP ITEM 121010
BROWN
POSITIVE POLE +24
Item Description
00 15 203 Set of cables with built-in energy saving device for connection to:
- Digital vacuum switch
- NC micro supply solenoid valve
- NC micro ejection solenoid valve
Cable length - 5 m
Connector
Item Description
00 15 157 Connector with LED for micro solenoid valves
Item Description
00 12 20 Electrical connection cable with M8 - 4 pin axial connector 8
for digital vacuum switch length 5 m
Item Description
00 12 21 Electrical connection cable with M8 - 4 pin radial connector
for digital vacuum switch length 5 m
8.67
ACCESSORIES AND SPARE PARTS FOR MULTI-STAGE AND
MULTI-FUNCTION VACUUM GENERATORS, SERIES MVG
3D drawings are available on vuototecnica.net
Item Description
00 15 436 NO micro solenoid valves with built-in low absorption electrical coil and interface
Micro solenoid
valve
Manual drive
Item Description
00 15 437 NC micro solenoid valves with built-in low absorption electrical coil and interface
Micro solenoid
valve
Manual drive
Item Description
00 15 178 Replacement plate for micro blowing solenoid valve
Item Description
12 10 10 Digital vacuum switch
8.68
MULTI-STAGE, MULTI-FUNCTION AND MODULAR VACUUM GENERATORS, SERIES
GVMM - GENERAL DESCRIPTION
Modular multi-function vacuum generators are true independent vacuum units that offer
an entire vacuum control system.
They feature a reduced thickness and weight compared to their suction flow rate and
they have been designed to be assembled with screws to one or more intermediate
8.69
MULTI-STAGE, MULTI-FUNCTION AND MODULAR VACUUM GENERATORS,
GVMM 3 and GVMM 7
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.70
MULTI-STAGE, MULTI-FUNCTION AND MODULAR VACUUM GENERATORS,
GVMM 3 and GVMM 7
GVMM3 portata Air flow rate (Nl/s) at different level of vacuum GVMM7
(-KPa) portata
at optimal supply pressure
GVMM 3 GVMM 7
GVMM 3 GVMM 7
0,8 1,8
GVMM7 portata
GVMM3 portata
1,6
0,7
GVMM 3 GVMM 7
1,4
0,6
0,9 2
1,2
0,5
Nl/s
Nl/s
0,8 1,8
1
0,4
1,6
0,8
0,7
0,3
1,4
0,6
0,6
0,2 1,2
0,4
0,5
0,1
Nl/s
Nl/s
1
0,2
0,4
0 0,8
0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
0,3
-Kpa 0,6 -Kpa
0,2
0,4
GVMM3 temp
0,1 Air flow rate (Nl/s)0,2at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal
GVMM7 supply pressure
tempi
item 0 bar Nl/s 0
0 10 20 30 40 50 60 70 80 0 10 20 30 0 4010 2050 30 60
40 50 70 60 80
70 80 -KPa
-Kpa -Kpa
GVMM 3 5.0
GVMM 30.8 0.83 0.66 0.38 0.20 0.16 0.11 GVMM 0.06
0.09 7 0.02 85
GVMM
GVMM37 temp 5.0 1.3 1.78 1.30 0.98 0.56 0.44 0.29 0.20 0.14 0.06 85
14000 6000
GVMM7 tempi
12000
5000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
GVMM 3 GVMM 7
10000
14000
GVMM 3 4000
6000
GVMM 7
8000
ms/l
ms/l
3000
12000
6000 5000
10000 2000
4000 4000
8000 1000
2000
ms/l
ms/l
3000
6000
0 0
10 20 30 40 50 60 70 80 85 2000 10 20 30 40 50 60 70 80 85
4000 -Kpa -Kpa
1000
2000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
GVMM 3 5.0 0.8 128 294 592 1167 1978 2889 4824 8588 12195 85
GVMM 7 5.0 1.3 59 137 275 543 921 1344 2245 3997 5676 85
8
ACCESSORIES AND SPARE PARTS UPON REQUEST
Item GVMM 3 GVMM 7
Sealing kit and reed valves item 00 KIT GVMM 3 00 KIT GVMM 7
Exhaust silencer item 00 15 150
Electrical connection cable with axial connector, for vacuum switch item 00 12 20
Electrical connection cable with radial connector, for vacuum switch item 00 12 21
Set of electrical connection cables, with built-in
NO energy saving device and connectors item 00 15 202
Set of electrical connection cables, with built-in
NC energy saving device and connectors item 00 15 203
Digital vacuum switch item 12 10 10
NO supply solenoid valve item 00 15 176
NC supply solenoid valve item 00 15 175
8.71
MULTI-STAGE, MULTI-FUNCTION AND MODULAR VACUUM GENERATORS,
GVMM 10 and GVMM 14
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.72
MULTI-STAGE, MULTI-FUNCTION AND MODULAR VACUUM GENERATORS,
GVMM 10 and GVMM 14
GVMM10 portata
GVMM14 portata
GVMM
Air flow rate 10 at different level of vacuum (-KPa) at optimal supply pressure
(Nl/s)
GVMM 10 GVMM 14
2
3 2,5
4
Nl/s
Nl/s
1,5 2
3,5
2,5
1,5
3
1
2
1
2,5
0,5
0,5
Nl/s
Nl/s
1,5 2
0 0
1,5
1 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
-Kpa -Kpa
1
4000
3000
3500
GVMM
Evacuation rates (ms/l10
=s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
GVMM 14
2500
3000
4500
GVMM 10 3500
GVMM 14
2500 2000
ms/l
ms/l
4000
3000
2000 1500
3500
1500 2500
3000 1000
1000
2500 2000
500
ms/l
ms/l
500
2000 1500
0 0
1500 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa 1000 -Kpa
1000
500
500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
GVMM 10 5.0 1.7 42 97 195 384 651 951 1589 2828 4016 85
GVMM 14 5.0 2.1 31 72 146 288 489 714 1193 2124 3016 85
8
ACCESSORIES AND SPARE PARTS UPON REQUEST
Item GVMM 10 GVMM 14
Sealing kit and reed valves item 00 KIT GVMM 10 00 KIT GVMM 14
Exhaust silencer item N°2 00 15 150
Electrical connection cable with axial connector, for vacuum switch item 00 12 20
Electrical connection cable with radial connector, for vacuum switch item 00 12 21
Set of electrical connection cables, with built-in
NO energy saving device and connectors item 00 15 202
Set of electrical connection cables, with built-in
NC energy saving device and connectors item 00 15 203
Digital vacuum switch item 12 10 10
NO supply solenoid valve item 00 15 176
NC supply solenoid valve item 00 15 175
8.73
MULTI-STAGE, MULTI-FUNCTION AND MODULAR INTERMEDIATE VACUUM MODULES
SERIES MI - GENERAL DESCRIPTION
Intermediate modules are non-independent multi-stage and multi-
function vacuum generators to be assembled to the generators of the
GVMM range.
Their thickness and weight are reduced to the maximum compared
3D drawings are available on vuototecnica.net
to their suction flow rate and they have been designed to be enclosed
between the lid and the base of the GVMM vacuum generator and
fixed with screws. The internal connections for the compressed air
supply allow communication between them and the basic generator,
with no need for external manifolds.
This way, each module becomes an independent vacuum unit that can
control an entire vacuum system.
They can be ordered in the desired amount and flow rate, either
already assembled onto the GVMM multi-function vacuum generator,
or separately, to be assembled to the GVMM generator previously
installed onto the machine. In this case, we suggest ordering a screw
kit suitable for the number of modules to be assembled.
MI intermediate vacuum modules are made up of the same elements
that compose GVMM generators, except for the lid. They operate and
they are used as the GVMM multi-function vacuum generator onto
which they are assembled.
8.74
INTERMEDIATE VACUUM MODULES MI 3 and MI 7
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.75
INTERMEDIATE VACUUM MODULES MI 3 and MI 7
MI 3 MI 7
MI 3 MI 7
3D drawings are available on vuototecnica.net
0,9 2
0,8 1,8
MI3 portata MI7 portata
1,6
0,7
MI 3 MI 7
1,4
0,6
0,9 2
1,2
0,5
1,8
Nl/s
1
Nl/s
0,8
0,4
1,6
0,8
0,7
0,3
1,4
0,6
0,6
0,2 1,2
0,4
0,5
Nl/s
1
Nl/s
0,1 0,2
0,4
0 0,8
0
0,3 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
-Kpa 0,6 -Kpa
0,2 0,4
MI3 temp MI7 temp
0,1 Air flow rate (Nl/s)0,2at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item 0 bar Nl/s 0
0 10 20 30 40 50 60 70 80 0 10 20 30 0 4010 2050 30 60
40 50 70 60 80
70 80 -KPa
-Kpa -Kpa
MI 3 5.0 0.8 0.83 0.66 0.38 0.20 0.16 0.11 0.09
MI 7 0.06 0.02 85
MI 3
MI 7
MI3 temp 5.0 1.3 1.78 1.30 0.98 MI7 0.56 0.44
temp 0.29 0.20 0.14 0.06 85
14000 6000
12000
5000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
MI 3 MI 7
10000
14000
MI 3 4000
6000
MI 7
8000
ms/l
ms/l
3000
12000
6000 5000
10000 2000
4000 4000
8000 1000
2000
ms/l
ms/l
3000
6000
0 0
10 20 30 40 50 60 70 80 85 2000 10 20 30 40 50 60 70 80 85
4000 -Kpa -Kpa
1000
2000
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MI 3 5.0 0.8 128 294 592 1167 1978 2889 4824 8588 12195 85
MI 7 5.0 1.3 59 137 275 543 921 1344 2245 3997 5676 85
8
ACCESSORIES AND SPARE PARTS UPON REQUEST
Item MI 3 MI 7
Sealing kit and reed valves item 00 KIT MI 3 00 KIT MI 7
Exhaust silencer item 00 15 150
Electrical connection cable with axial connector, for vacuum switch item 00 12 20
Electrical connection cable with radial connector, for vacuum switch item 00 12 21
Set of electrical connection cables, with built-in
NO energy saving device and connectors item 00 15 202
Set of electrical connection cables, with built-in
NC energy saving device and connectors item 00 15 203
Digital vacuum switch item 12 10 10
NO supply solenoid valve item 00 15 176
NC supply solenoid valve item 00 15 175
8.76
INTERMEDIATE VACUUM MODULES MI 10 and MI 14
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.77
INTERMEDIATE VACUUM MODULES MI 10 and MI 14
3 4
3,5
MI10
2,5 portata MI14 portata
MI 10 3 MI 14
2
3 2,5
44
Nl/s
1,5 2
3,5
3,5
Nl/s
2,5
1,5
3
1
2
1
2,5
2,5
0,5
0,5
Nl/s
Nl/s
1,5 2
Nl/s
0 0
1,5
1,5
1 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
-Kpa -Kpa
1
MI100,5 temp
Air flow rate (Nl/s)
MI140,5at different
0,5
temp levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item 0 bar Nl/s 0
0 10 20 30 40 50 60 70 80 0 10 20 30 00 401010 50
20
20 30
30 60
40
40 50
50 70 60
60 80
70
70 80
80 -KPa
-Kpa -Kpa
-Kpa
MI 10 5.0 MI 10 1.7 2.52 2.00 1.66 0.97 0.56 0.40 0.22 0.16 0.07 85
MI 14
MI10 temp 5.0 2.1 3.35 2.42 1.84 0.99 0.80 0.58 0.34 0.22 0.10 85
MI14 temp
4500 3500
4000
3000
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure
3500 MI 10 MI 14
2500
3000
4500
MI 10 3500
MI 14
2500 2000
ms/l
4000
ms/l
3000
2000 1500
3500
1500 2500
3000 1000
1000
2000
2500 500
ms/l
500
ms/l
2000 1500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
1500
-Kpa 1000 -Kpa
1000
500
500
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
-Kpa -Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
MI 10 5.0 1.7 42 97 195 384 651 951 1589 2828 4016 85
MI 14 5.0 2.1 31 72 146 288 489 714 1193 2124 3016 85
8
ACCESSORIES AND SPARE PARTS UPON REQUEST
Item MI 10 MI 14
Sealing kit and reed valves item 00 KIT MI 10 00 KIT MI 14
Exhaust silencer item N°2 00 15 150
Electrical connection cable with axial connector, for vacuum switch item 00 12 20
Electrical connection cable with radial connector, for vacuum switch item 00 12 21
Set of electrical connection cables, with built-in
NO energy saving device and connectors item 00 15 202
Set of electrical connection cables, with built-in
NC energy saving device and connectors item 00 15 203
Digital vacuum switch item 12 10 10
NO supply solenoid valve item 00 15 176
NC supply solenoid valve item 00 15 175
8.78
ACCESSORIES AND SPARE PARTS FOR VACUUM GENERATORS AND MODULES SERIES
GVMM and MI
Red Blue
Suction
Blowing
valve
valve
Connector for
vacuum switch
Digital
vacuum
switch
Manifold
WHITE
DIGITAL OUTPUT (+24) DIGITAL VACUUM SWITCH PNP
ITEM 121010
BROWN
POSITIVE POLE +24
GREY CONNECTION SUPPLY SOLENOID VALVE
NEGATIVE POLE - 0 V
DISTRIBUTOR NO
BLACK 8
SUCTION ON +24V
BLUE BLOWING SOLENOID VALVE
BLOWING ON +24V NC
Item Description
00 15 202 Set of cables with built-in energy saving device for connection to:
- Digital vacuum switch
- NO micro supply solenoid valve
- NC micro ejection solenoid valve
Cable length - 5 m
8.79
ACCESSORIES AND SPARE PARTS FOR VACUUM GENERATORS AND MODULES SERIES
GVMM and MI
WHITE
DIGITAL OUTPUT (+24) DIGITAL VACUUM SWITCH PNP
ITEM 121010
POSITIVE POLE +24 BROWN
Item Description
00 15 203 Set of cables with built-in energy saving device for connection to:
- Digital vacuum switch
- NC micro supply solenoid valve
- NC micro ejection solenoid valve
Cable length - 5 m
Connector
Item Description
00 15 157 Connector with LED for micro solenoid valves
Item Description
00 12 20 Electrical connection cable with M8 - 4 pin axial connector
for digital vacuum switches length 5 m
Item Description
12 10 10 Digital vacuum switch
8.80
ACCESSORIES AND SPARE PARTS FOR VACUUM GENERATORS AND MODULES SERIES
GVMM and MI
Item Description
00 15 176 NO micro supply solenoid valve - h = 43 mm
Item Description
00 15 175 NC supply and blowing micro solenoid valve - h = 37.5 mm
Plexiglass manifolds
Item Description
00 15 171 Plexiglass suction manifold for GVMM - MI 3/7
00 15 188 Plexiglass suction manifold for GVMM - MI 10/14
Aluminium manifolds
Item Description
00 15 174 Aluminium suction manifold for GVMM - MI 3/7
00 15 187 Aluminium suction manifold for GVMM - MI 10/14
Support
Item Description
00 15 306 L-shaped fixing support in galvanised steel sheet
8.81
MODULAR VACUUM SYSTEMS SET-UP
EXAMPLE OF SET-UP 1
No. Item B
1 GVMM 3 - 7 20
2 MI 10 - 14 25
3 MI 3 - 7 20
Total length L= 65
Required screw kit: Item 00 KIT GVMM 02
Ordering example:
1 Generator GVMM 3
1 Intermediate module MI 10
1 Intermediate module MI 3
1 kit of stainless steel screws 00 KIT GVMM 02
Ordering example:
1 Generator GVMM 10
1 Intermediate module MI 3
1 Intermediate module MI 10
1 kit of stainless steel screws 00 KIT GVMM 03
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
8.82
MULTI-STAGE VACUUM GENERATORS PVP 12 MX / MXLP and 25 MX / MXLP
2 Ø 6.5 holes
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.83
MULTI-STAGE VACUUM GENERATORS PVP 12 MX / MXLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
portata
PVP 12 MX
PVP12 MXLP 7
Nl/s
portata 3
PVP 12 MX
PVP12 MXLP 27
16
05
0 10 20 30 40 50 60 70 80
-Kpa
4
Nl/s
3
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. tempAir consumption
at optimal supply pressure
item bar PVP 12 MX Nl/s 2
PVP12 MXLP 8000 0 10 20 30 40 50 60 70 80 -KPa
PVP 12 MX 6.0 1.57000
1 5.80 4.14 2.76 1.38 0.98 0.78 0.59 0.41 0.23 90
PVP 12 MXLP 3.0 2.3 5.00 2.27 1.66 1.05 0.88 0.77 0.64 0.42 0.22 86
6000
0
0 10 20 30 40 50 60 70 80
5000 -Kpa
temp
PVP 12 MX
3000
PVP 12 MX PVP 12 MXLP
PVP12 MXLP 8000
2000
7000
1000
6000
0
10 20 30 40 50 60 70 80 85
5000
-Kpa
ms/l
4000
3000
2000
1000
0
10 20 30 40 50 60 70 80 85
-Kpa
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 12 MX 6.0 1.5 15 38 85 204 365 559 929 1607 5916 90
PVP 12 MXLP 3.0 2.3 22 56 120 240 410 650 975 1950 7160 86
8
ACCESSORIES UPON REQUEST
Silencer item SSX 3/8’’
8.84
MULTI-STAGE VACUUM GENERATORS PVP 25 MX / MXLP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.85
MULTI-STAGE VACUUM GENERATORS PVP 25 MX / MXLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
portata
PVP 25 MX
PVP 25 MXLP 10
Nl/s
5
portata 4
PVP 25 MX 3
PVP 25 MXLP 10
2
9
1
8
0
7
0 10 20 30 40 50 60 70 80
6 PVP 25 MX -Kpa
PVP 25 MXLP
Nl/s
5
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
temp 4
at optimal supply pressure
item bar PVP 25 MX
Nl/s 3
6000
PVP 25 MXLP
0 10 20 30 40 50 60 70 80 -KPa
2
PVP 25 MX 6.0 3.05000 8.61 6.15 4.10 2.05 1.46 1.17 0.88 0.61 0.35 90
1
PVP 25 MXLP 3.0 4.5 9.44 3.77 2.77 1.72 1.58 1.36 1.11 0.72 0.37 86
0
4000 0 10 20 30 40 50 60 70 80
PVP 25 MX -Kpa
PVP 25 MXLP
Evacuation rates (ms/l =s/m
3000 ) at different levels of vacuums (-KPa) at optimal supply pressure
ms/l
temp
1000
5000
0
4000 10 20 30 40 50 60 70 80 85
PVP 25 MX -Kpa
PVP 25 MXLP
ms/l
3000
2000
1000
0
10 20 30 40 50 60 70 80 85
PVP 25 MX -Kpa
PVP 25 MXLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 25 MX 6.0 3.0 10 26 57 137 246 377 626 1083 3986 90
PVP 25 MXLP 3.0 4.5 16 41 83 165 290 460 690 1380 5070 86
8
ACCESSORIES UPON REQUEST
4 silencers item SSX 1/4’’
8.86
MULTI-STAGE VACUUM GENERATORS PVP 40 M / MLP ÷ PVP 300 M / MLP
Created to be assembled on OCTOPUS gripping systems, this series of generators is available with
suction capacities between 24 and 320 m3/h. The supply pressure goes from 4-6 bar for M items
and from 1-3 bar for MLP items. Level of vacuum and flow rate can be adjusted according to the
supply air pressure. Characterised by their new generation of ejectors, boasting an excellent ratio
Vacuum
gauge
Pressure
gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.87
MULTI-STAGE VACUUM GENERATORS PVP 40 M / MLP,
PVP 70 M / MLP and PVP 100 M / MLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
portata
PVP 40 M
PVP 40 MLP
3D drawings are available on vuototecnica.net
portata
12 30
20
10 25
15
8 20
Nl/s
Nl/s
Nl/s
6 15
10
4 10
5
2 5
0 0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 40 M -Kpa PVP 70 M -Kpa PVP 100 M -Kpa
temp PVP 40 MLP PVP 70 MLP PVP 100 MLP
PVP 40 M
PVP 40 MLP
temp
PVP 70 M temp
portata PVP 70 MLP
PVP 40 M 3500 Air flow rate (Nl/s) at different
PVP 100 MLPlevels1800
PVP 100 M
of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
2500
PVP 40 MLP
PVP 70 M portata at optimal supply
portata
pressure
3000 item bar PVP 70Nl/s
MLP
PVP 100 M
1600
25
2000
0 10 20 30 40
PVP 100 MLP 5035 60 70 80 -KPa
14 1400
PVP 40 M
2500
6.0 3.2 11.66 8.32 5.55 2.77 1.98 1.5830 1.19 0.83 0.47 90
1200
PVP 70 M
12
2000
6.0 6.6 20
1500 22.20 15.80 10.50 5.29 3.77 3.02 2.27 1.58 0.90 90
PVP 100 M 6.0 9.8 30.00 21.40 14.20 7.14 5.10 1000
4.0825 3.06 2.14 1.22 90
ms/l
ms/l
ms/l
10
1500 800
15
1000 20
8PVP 40 MLP 3.0 4.4 11.40 5.42 3.45 2.19 2.03 1.72 1.34 0.95 0.54 88
Nl/s
600
Nl/s
1000
Nl/s
1600
3000
2000
1400
2500
1200
1500
2000 1000
ms/l
ms/l
ms/l
800
1500
1000
600
1000
500 400
500
200
0 0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
8
10 20 30 40 50 60 70 80 85
PVP 40 M -Kpa PVP 70 M -Kpa PVP 100 M -Kpa
PVP 40 MLP PVP 70 MLP PVP 100 MLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 40 M 6.0 3.2 7.7 19.2 42.3 101.6 182.0 278.4 462.3 799.8 2943 90
PVP 70 M 6.0 6.6 4.0 10.1 22.2 53.3 95.5 146.1 242.6 419.7 1544 90
PVP 100 M 6.0 9.8 3.0 7.4 16.4 39.5 70.7 108.2 179.6 310.8 1144 90
PVP 40 MLP 3.0 4.4 12.0 28.0 58.0 116.0 158.0 250.0 382.0 764.0 2820 88
PVP 70 MLP 3.0 8.9 9.0 21.0 44.0 88.0 120.0 190.0 290.0 580.0 2150 88
PVP 100 MLP 3.0 13.3 7.0 16.0 34.0 68.0 93.0 147.0 224.0 448.0 1650 88
8.88
MULTI-STAGE VACUUM GENERATORS PVP 140 M / MLP,
PVP 170 M / MLP and PVP 200 M / MLP
Pressure
gauge
Item PVP 140 MLP PVP 170 MLP PVP 200 MLP
Intake air flow rate m3/h 73 115 138 80 137 165 105 157 190
Maximum level of vacuum -KPa 30 64 88 30 64 88 30 64 88
Final pressure abs. mbar 700 360 120 700 360 120 700 360 120
Supply pressure bar 1 2 3 1 2 3 1 2 3
Optimal supply pressure bar
8
3 3 3
Air consumption Nl/s 8.6 13.3 17.8 10.5 16.3 22.2 12.8 20.0 26.6
Temperature of use °C -20 / +100 -20 / +100 -20 / +100
Noise level at
optimal supply pressure dB(A) 75 76 78
Weight Kg 5.1 5.1 5.1
Spare parts PVP 140 M / MLP PVP 170 M / MLP PVP 200 M / MLP
Sealing kit and reed valves item 00 KIT PVP 140 M 00 KIT PVP 170 M 00 KIT PVP 200 M
Exhaust silencer item 00 15 110 00 15 110 00 15 110
Silencer on nozzles item N°2 00 15 111 N°2 00 15 111 N°2 00 15 111
Vacuum gauge item 09 03 15 09 03 15 09 03 15
Pressure gauge item 09 03 25 09 03 25 09 03 25
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.89
MULTI-STAGE VACUUM GENERATORS PVP 140 M / MLP,
PVP 170 M / MLP and PVP 200 M / MLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
portata
PVP 140 M PVP 170 M portata PVP 200 M portata
PVP 140 MLP PVP 170 MLP PVP 200 MLP
3D drawings are available on vuototecnica.net
45
PVP 140 M PVP 140 MLP PVP 170 M PVP 170 MLP 60
PVP 200 M PVP 200 MLP
60
40
50 50
35
30 40 40
25
Nl/s
Nl/s
Nl/s
30 30
20
15 20 20
10
10 10
5
0 0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 140 M -Kpa PVP 170 M -Kpa PVP 200 M -Kpa
PVP 140 MLP PVP 170 MLP PVP 200 MLP
temp
portata
PVP 170 M temp PVP 200 M temp
PVP 140 M
PVP 140 M PVP 170 M portata PVP 200
200 M
MLP
PVP 140 MLP PVP 170 MLP PVP portata
PVP 140 MLP PVP 170 MLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa)
PVP 200 MLP Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
700
1000
45 item bar Nl/s 800
60
900
0 10 20 30 40 5060 60 70 80 -KPa
40 700 600
PVP 140 M
800 6.0 13.0 50 42.20 30.10 20.10 10.00 7.18 5.7450 4.31 3.02 1.72 90
35 600
PVP 170 M
700 6.0 16.3 50.50 36.10 24.00 12.03 8.59 6.87
500
5.17 3.61 2.06 90
PVP 200 M
30
600
6.0 19.4 40
500 55.50 39.60 26.40 13.22 9.44 7.5540
400
5.68 3.97 2.27 90
25
Nl/sms/l
ms/l
400
ms/l
500
Nl/s
PVP 140 MLP 3.0 17.8 38.30 18.30 11.60 7.36 6.84 5.80 4.50 3.20 1.80 88
Nl/s
30 30
300
20
400
PVP 170 MLP 3.0 22.2 300
45.80 21.80 13.80 8.81 8.18 6.94 5.39 3.82 2.16 88
15
300 20 200
PVP 200 MLP 3.0 26.6 200 52.80 25.20 16.00 10.10 9.40 8.0020 6.20 4.40 2.50 88
200
10
100
10
100 10
100
5
0 0
0
0 0 10 20 30 40 50 60 70 80 85
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
-Kpa PVP 170 M -Kpa 0 PVP
10 20020M 30 -Kpa
40 50 60 70 80
PVP 140 M -Kpa
PVP 140 M PVP
PVP 170
170 MMLP -Kpa PVP 200 MLP
PVP 140 MLP PVP 200 M -Kpa
PVP 140 MLP PVP 170 MLP
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply pressure PVP 200 MLP
temp
PVP 140 M PVP 170 M temp PVP 200 M temp
PVP 140 MLP PVP 170 MLP PVP 200 MLP
1000
PVP 140 M PVP 140 MLP 800
PVP 170 M PVP 170 MLP 700
PVP 200 M PVP 200 MLP
900
700 600
800
600
700 500
500
600
400
ms/l
ms/l
400
ms/l
500
300
400
300
300 200
200
200
100 100
100
0 0 0
8 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
PVP 140 M -Kpa PVP 170 M -Kpa PVP 200 M -Kpa
PVP 140 MLP PVP 170 MLP PVP 200 MLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 140 M 6.0 13.0 2.1 5.3 11.7 28.0 50.2 76.9 127.6 220.8 812 90
PVP 170 M 6.0 16.3 1.7 4.4 9.7 23.4 42.0 64.2 106.6 184.5 678 90
PVP 200 M 6.0 19.4 1.6 4.0 8.9 21.3 38.2 58.4 97.0 167.8 618 90
PVP 140 MLP 3.0 17.8 3.6 8.4 17.7 35.4 48.3 76.5 116.8 233.0 860 88
PVP 170 MLP 3.0 22.2 3.0 7.1 14.9 29.9 40.6 64.2 98.0 196.0 720 88
PVP 200 MLP 3.0 26.6 2.8 6.5 13.6 27.3 37.2 58.8 89.7 180.0 665 88
8.90
MULTI-STAGE VACUUM GENERATORS PVP 250 M / MLP and PVP 300 M / MLP
Pressure
gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.91
MULTI-STAGE VACUUM GENERATORS PVP 250 M / MLP and PVP 300 M / MLP
portata
portata
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
PVP 250 M PVP 300 M
PVP 250 MLP PVP 300 MLP
3D drawings are available on vuototecnica.net
90
PVP 250 M PVP 250 MLP 100
PVP 300 M PVP 300 MLP
80 90
80
70
70
60
60
50
50
Nl/s
Nl/s
40
40
portata
30
portata 30
PVP 250 M PVP 300 M
PVP 250 MLP 20 PVP 300 MLP
20
10 10
90 100
0 0
80 90
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 250 M -Kpa 80 PVP 300 M -Kpa
70 PVP 250 MLP PVP 300 MLP
70
60 temp
PVP 250 M temp
60
PVP 250 MLP 50 PVP 300 M
Air flow rate (Nl/s) Max vacuum
Generator Supp. press. Air consumption PVP 300 MLP 50 at different levels of vacuums (-KPa)
Nl/s
Nl/s
250
ms/l
250
ms/l
200
200
150
150
100 100
50 50
8
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
PVP 250 M -Kpa PVP 300 M -Kpa
PVP 250 MLP PVP 300 MLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 250 M 6.0 24.0 1.1 2.9 6.4 15.2 27.3 41.8 69.3 119.9 442.0 90
PVP 300 M 6.0 29.0 1.0 2.5 5.5 13.3 23.8 36.5 60.6 104.9 386.0 90
PVP 250 MLP 3.0 33.6 2.0 4.6 9.6 19.3 26.3 41.5 63.5 127.0 468.7 88
PVP 300 MLP 3.0 39.3 1.7 3.9 8.2 16.4 22.3 35.3 54.0 108.0 398.5 88
8.92
ACCESSORIES FOR VACUUM GENERATORS PVP 40 M / MLP ÷ PVP 300 M / MLP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.93
ACCESSORIES FOR VACUUM GENERATORS PVP 40 M / MLP ÷ PVP 300 M / MLP
of atmospheric air into the vacuum system (tanks, autoclaves, intake systems depression, vacuum cups, etc.), when the generator stops,
guaranteeing the seal and maintaining the level of vacuum reached in use.
The three components described above make up an energy saving kit for the compressed air supply ES (Energy Saving System). In fact, the ES
device acts directly on the generator, making it operate only within the preset vacuum values, thus limiting compressed air supply consumption;
all this entails considerable energy savings.
This kit has been designed for the PVP 40 - 300 M/MLP series of generators.
8
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.94
MULTI-STAGE VACUUM GENERATORS PVP 25 MDX / MDXLP ÷ PVP 75 MDX / MDXLP
Pressure Silencer
gauge
2 Ø 6.5 holes
Vacuum
gauge
Spare parts PVP 25 MDX / MDXLP PVP 35 MDX / MDXLP PVP 50 MDX / MDXLP
Sealing kit and reed valves item 00 KIT PVP 25 MDX 00 KIT PVP 35 MDX 00 KIT PVP 50 MDX
Vacuum gauge item 09 03 15 09 03 15 09 03 15
Pressure gauge item 09 03 25 09 03 25 09 03 25
Silencer item SSX 3/4” SSX 3/4” SSX 3/4”
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.95
MULTI-STAGE VACUUM GENERATORS PVP 25 MDX / MDXLP,
PVP 35 MDX / MDXLP and PVP 50 MDX / MDXLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply
portata
pressure
14
PVP 25 MDX PVP 25 MDXLP 18
PVP 35 MDX PVP 35 MDXLP PVP 50 MDX PVP 50 MDXLP
20
16 18
12
14 16
10 14
12
12
8 10
10
Nl/s
Nl/s
Nl/s
6 8
8
6
4 6
4
4
2
2 2
0 0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 25 MDX -Kpa PVP 35 MDX -Kpa PVP 50 MDX -Kpa
PVP 25 MDXLP PVP 35 MDXLP PVP 50 MDXLP
portata
ms/l Nl/s
Nl/sms/l
ms/lNl/s
2500 10
PVP 25 MDXLP
6 3.0 4.4 1500 9.7 4.7 3.5 2.2 2.0 1.7
1500
8 1.4 1.0 0.6 88
2000 8
PVP 35 MDXLP 3.0 6.5 13.0 6.2 4.7 3.0 2.7 2.3 6 1.8 1.3 0.7 88
4
1500 1000
PVP 50 MDXLP 3.0 8.6 6
16.1 7.7 5.8 3.7 3.3 2.8
1000
4
2.2 1.5 0.8 88
1000
2 4
500
2
500
500 2
0 0 0
0 10 20 30 40 50 60 70 80 10 20 30 40 50 60 70 80 85 0 10 20 30 40 50 60 70 80
0 0 0
10 PVP20
25 MDX
30 40 -Kpa
50 60 70 80 85 0 PVP
10 35 MDX
20 30 -Kpa
40 50 60 70 80 PVP 50 MDX -Kpa
10 PVP20 30
50 MDXLP 40 50 60 70 80 85
PVP 25 MDXLP PVP 35 MDXLP
PVP 25 MDX -Kpa PVP 35 MDX
PVP 50 MDX -Kpa -Kpa
Evacuation rates (ms/l =s/m3) at different levels of vacuums (-KPa) at optimal supply
PVP 25 MDXLP PVP 35 MDXLP pressure
PVP 50 MDXLP
temp
4500
PVP 25 MDX PVP 25 MDXLP PVP 35 MDX PVP 35 MDXLP 3000
PVP 50 MDX PVP 50 MDXLP
3500
4000
3000
2500
3500
2500
3000 2000
2500 2000
ms/l
ms/l
ms/l
1500
2000
1500
1500 1000
1000
1000
500
500
500
0 0 0
8 10 20 30
PVP 25 MDX
40 50
-Kpa
60 70 80 85 10 20
PVP 35 MDX
30 40 50
-Kpa
60 70 80 85 10 20
PVP 50 MDX
30 40 50
-Kpa
60 70 80 85
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 25 MDX 6.0 3.2 7.5 18.8 41.3 99.3 177.7 271.9 451.4 781.0 2874 90
PVP 35 MDX 6.0 4.8 5.6 14.1 31.2 74.9 134.0 205.1 340.5 589.1 2618 90
PVP 50 MDX 6.0 6.5 4.7 11.9 26.2 62.8 112.4 172.0 285.5 494.0 1818 90
PVP 25 MDXLP 3.0 4.4 13.0 33.3 67.2 134.4 238.0 376.0 564.0 1128.0 4151 88
PVP 35 MDXLP 3.0 6.5 9.8 25.2 50.9 101.9 180.3 284.9 427.3 854.7 3145 88
PVP 50 MDXLP 3.0 8.6 7.9 20.3 41.0 82.0 145.3 229.5 344.3 688.5 2534 88
8.96
MULTI-STAGE VACUUM GENERATORS PVP 60 MDX / MDXLP and PVP 75 MDX / MDXLP
Pressure Silencer
gauge
2 Ø 6.5 holes
Vacuum
gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.97
MULTI-STAGE VACUUM GENERATORS PVP 60 MDX / MDXLP and PVP 75 MDX / MDXLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
PVP 60 MDX portata PVP 75 MDX portata
PVP 60 MDXLP PVP 75 MDXLP
3D drawings are available on vuototecnica.net
30
PVP 60 MDX PVP 60 MDXLP 35
PVP 75 MDX PVP 75 MDXLP
30
25
25
20
20
Nl/s
Nl/s
15
15
10
PVP 75 MDX 10 portata
PVP 60 MDX portata PVP 75 MDXLP
PVP 60 MDXLP 5
5
35
30
0 0
0 10 20 30 40 50 60 70 80 30 0 10 20 30 40 50 60 70 80
PVP 60 MDX -Kpa PVP 75 MDX -Kpa
25 PVP 60 MDXLP PVP 75 MDXLP
25
PVP 60 MDX temp
20 temp
PVP 60 MDXLP PVP 75 MDX
Air flow rate (Nl/s)
20 at different vacuum levels (-KPa) Max vacuum
Generator Supp. press. Air consumption PVP 75 MDXLP
at optimal supply pressure
Nl/s
15
2500 0 10 20 15 30 40 50 60 70 80 -KPa
2000
PVP 60 MDX 6.0 8.2 25.5 18.2 12.2 6.1 4.3 3.5 2.6 1.8 1.0 90
10 1800
10
PVP 75 MDX
2000 6.0 9.8 28.6 20.4 13.6 6.8 4.8 3.9 2.9 2.0 1.2 90
1600
5
PVP 60 5MDXLP 3.0 11.0 19.3 9.3 7.0 14004.4 4.0 3.4 2.7 1.9 1.0 88
PVP 75
1500MDXLP 3.0 13.2 22.5 10.8 8.1 5.1 4.6 3.9 3.1 2.2 1.2 88
0
1200
0 0 10 20 30 40 50 60 70 80
ms/l
0 10 20 30 40 50 60 70 80
ms/l
1500 1200
ms/l
ms/l
1000
1000 800
600
500 400
8 200
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
PVP 60 MDX -Kpa PVP 75 MDX -Kpa
PVP 60 MDXLP PVP 75 MDXLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 60 MDX 6.0 8.2 3.5 8.8 19.3 46.4 83.0 127.0 211.0 365.0 1343 90
PVP 75 MDX 6.0 9.8 3.1 7.8 17.2 41.4 74.2 113.5 188.4 326.0 1200 90
PVP 60 MDXLP 3.0 11.0 6.6 16.8 34.0 68.0 120.3 190.0 285.0 570.0 2098 88
PVP 75 MDXLP 3.0 13.2 5.7 14.5 29.2 58.4 103.4 163.4 245.0 490.3 1805 88
8.98
ACCESSORIES FOR VACUUM GENERATORS
PVP 25 MDX / MDXLP ÷ PVP 75 MDX / MDXLP
1
4
3
1 - MINI PNEUMATIC VACUUM SWITCH
The vacuum switch has the task of removing a pneumatic signal when a specific adjustable level of vacuum is reached. The pressure differential
existing between the set maximum value and that of restoring the signal at rest is not adjustable and is equal to about 100 mbar.
The pneumatic vacuum switch, installed on the vacuum generators PVP 25 - 75 MDX / MDXLP acting on the coaxial shutter supply valve
automatically maintains the maximum and minimum level of vacuum within the differential value.
Sp1 Sp2
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.99
ACCESSORIES FOR VACUUM GENERATORS
PVP 25 MDX / MDXLP ÷ PVP 75 MDX / MDXLP
vacuum switch
A check valve specially designed to adapt to vacuum generators PVP
25 - 75 MDX / MDXLP.
The originality of this valve, besides its shape, consists in its
membrane seal component, which is able to guarantee very low
pressure drops, rapid intervention and perfect sealing.
4 TCCE M4 screws
8
COMPLETE KIT FOR ENERGY SAVING DEVICE ES
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.100
SILENCERS
A B C C1 D d Weight
Item
Ø Ø Ø g
SSX 1/8” G1/8” 10 58 -- 17 7 14
SSX 1/4” G1/4” 10 60 -- 20 10 20
SSX 3/8” R G3/8” 7 57 -- 20 10 17 8
SSX 3/8” G3/8” 12 84 -- 29 16 52
SSX 1/2” G1/2” 14 106 -- 35 16 96
SSX 3/4” R G3/4” 14 106 -- 35 16 100
SSX 3/4” G3/4” 14 126 -- 50 21 174
SSX 1” G1” 14 146 -- 55 28 240
SSX 1” 1/2 G1” 1/2 30 210 -- 80 38 302
SSX 2” G2” 30 250 -- 90 48 372
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.101
MULTI-STAGE AND MODULAR VACUUM GENERATORS
PVP 150 MD / MDLP ÷ PVP 750 MD / MDLP - GENERAL DESCRIPTION
The special shape of these vacuum generators has allowed obtaining great suction
capacities in very limited overall dimensions.
The new design stainless steel ejectors are assembled on modular frames; the overlapping
of one or more frames defines the flow rate of the generators. They are supplied with a flow
3D drawings are available on vuototecnica.net
rate ranging from 85 e 900 m3/h and a maximum level of vacuum of -90KPa.
The supply pressure goes from 4-6 bar for MD items and from 1-3 bar
for MDLP items. Level of vacuum and flow rate can be adjusted according to the supply
air pressure. They are fully made with anodised aluminium.
The sealing gaskets and disc valves are EPDM as standard, but can be supplied in
VITON® upon request. Also upon request, an energy saving kit for the compressed air
ES (Energy Saving System) can be supplied. It is composed of a pneumatic coaxial
shutter valve for supply of the compressed air, an integrated pneumatic vacuum switch,
a reed valve kit for the check system and a flexible tube with quick fitting to monitor and
transmit the value of the level of vacuum to the vacuum switch.
Perfectly soundproofed with silencers built into all generators, offering extremely quiet
operation.
8.102
MULTI-STAGE AND MODULAR VACUUM GENERATORS PVP 150 MD / MDLP
and PVP 300 MD / MDLP
Pressure Vacuum
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.103
MULTI-STAGE AND MODULAR VACUUM GENERATORS PVP 150 MD / MDLP
and PVP 300 MD / MDLP
60
PVP 150 MD PVP 150 MDLP 120
PVP 300 MD PVP 300 MDLP
50 100
40 80
Nl/s
Nl/s
30 60
20 PVP 300 MD 40
PVP 150 MD portata portata
PVP 300 MDLP
PVP 150 MDLP
10 20
120
60
0 0
0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
50
100
PVP 150 MD -Kpa PVP 300 MD -Kpa
PVP 150 MDLP PVP 3000 MDLP
40 80
30
at optimal supply pressure
item bar Nl/s
1000
0 10 20 30 40 50 60 70 80 -KPa
20 40
700
PVP 150 MD 6.0 16.0 55.5 39.6 26.5 13.2 9.4 7.5 5.7 4.0 2.3 90
900
PVP 300 MD 6.0 32.0 111.1 79.4 52.9 600
26.5 19.9 15.1 11.4 7.9 4.5 90
10 20
800
PVP 150
700 MDLP 3.0 22.6 47.2 24.5 15.9 500
10.3 9.3 7.5 4.7 3.2 1.8 88
PVP 3000 MDLP 3.0 45.5 94.4 49.0 31.9 0 20.7 18.6 15.1 9.3 6.5 3.7 88
600 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 150 MD -Kpa 400 PVP 300 MD -Kpa
PVP 3000 MDLP
ms/l
500
ms/l
400 300
100
1000
PVP 150 MD PVP 150 MDLP 100
700
PVP 300 MD PVP 300 MDLP
0
900 0
10 20 30 40 50 60 70 80 85 600 10 20 30 40 50 60 70 80 85
800 PVP 150 MD -Kpa PVP 300 MD -Kpa
PVP 150 MDLP PVP 300 MDLP
700 500
600
400
ms/l
ms/l
500
300
400
300 200
200
100
8 100
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
PVP 150 MD -Kpa PVP 300 MD -Kpa
PVP 150 MDLP PVP 300 MDLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 150 MD 6.0 16.0 1.6 4.0 8.9 21.3 38.2 58.4 97.0 167.8 618 90
PVP 300 MD 6.0 32.0 0.8 2.0 4.4 10.6 19.1 29.2 48.5 83.9 386 90
PVP 150 MDLP 3.0 22.6 2.9 7.5 15.0 30.1 53.3 84.2 126.3 252.5 930 88
PVP 300 MDLP 3.0 45.5 2.0 5.2 10.5 21.0 37.2 58.7 88.0 176.1 650 88
8.104
MULTI-STAGE AND MODULAR VACUUM GENERATORS PVP 450 MD / MDLP
and PVP 600 MD / MDLP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.105
MULTI-STAGE AND MODULAR VACUUM GENERATORS PVP 450 MD / MDLP
and PVP 600 MD / MDLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
PVP 450 MD portata PVP 6000 MD portata
PVP 450 MDLP PVP 600 MDLP
3D drawings are available on vuototecnica.net
180
PVP 450 MD PVP 450 MDLP PVP 600 MD PVP 600 MDLP
250
160
200
140
120
150
100
Nl/s
Nl/s
80
PVP 6000 MD 100
portata
60 PVP 600 MDLP
PVP 450 MD portata
40
PVP 450 MDLP 50
250
20
180
0 0
200
160 0 10 20 30 40 50 60 70 80 0 10 20 30 40 50 60 70 80
PVP 450 MD -Kpa PVP 600 MD -Kpa
140 PVP 450 MDLP PVP 600 MDLP
150
120
PVP 450 MD
Nl/s
temp
PVP 450 MDLP
100 Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption 100
PVP 600 MD at optimal
temp supply pressure
Nl/s
item
80
450 bar Nl/s PVP 600 MDLP
0 10 20 30 40 50 60 70 80 -KPa
PVP 450
60 MD
400 6.0 47.8 161.1 115.0 76.7 5038.3
300
27.4 21.9 16.5 11.5 6.6 90
PVP 600
40
MD 6.0 63.2 208.3 148.8 99.2 49.6 35.4 28.3 21.3 14.9 8.5 90
350
250
0
PVP 450
20 MDLP
300 3.0 65.8 138.8 72.7 46.9 30.50 27.4
10 20
22.230 13.8
40 50
9.6 60 5.570 80
88
PVP 600 MDLP 3.0 87.7 186.1 96.7 62.9 40.8 36.8
PVP 600 MD29.8 18.5
-Kpa 12.9 6.8 88
0
250
200 PVP 600 MDLP
0 10 20 30 40 50 60 70 80
ms/l
150
150
50
450
PVP 450 MD PVP 450 MDLP PVP 600 MD PVP 600 MDLP
300
50
0
400 10 20 30 40 50 60 70 80 85
PVP 450 MD -Kpa 250
0
350 PVP 450 MDLP 10 20 30 40 50 60 70 80 85
PVP 600 MD -Kpa
300 200 PVP 600 MDLP
250
ms/l
ms/l
150
200
150 100
100
50
50
8
0 0
10 20 30 40 50 60 70 80 85 10 20 30 40 50 60 70 80 85
PVP 450 MD -Kpa PVP 600 MD -Kpa
PVP 450 MDLP PVP 600 MDLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 450 MD 6.0 47.8 0.5 1.4 3.0 7.4 13.2 20.1 33.5 57.9 213 90
PVP 600 MD 6.0 63.2 0.4 1.0 2.4 5.7 10.2 15.6 25.9 44.8 165 90
PVP 450 MDLP 3.0 65.8 1.2 3.0 6.2 12.4 22.0 34.7 52.0 104.1 383 88
PVP 600 MDLP 3.0 87.7 0.8 2.0 4.1 8.2 14.6 23.1 34.7 69.4 256 88
8.106
MULTI-STAGE AND MODULAR VACUUM GENERATORS PVP 750 MD / MDLP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.107
MULTI-STAGE AND MODULAR VACUUM GENERATORS PVP 750 MD / MDLP
PVP Air
750 MD
flow rate (Nl/s) at different levels of vacuums (-KPa) at optimal supply pressure
portata
PVP 750 MDLP
3D drawings are available on vuototecnica.net
250
200
Nl/s
100
300
50
250
0
0 10 20 30 40 50 60 70 80
200
PVP 750 MD -Kpa
PVP 750 MDLP
Nl/s
150 temp
PVP 750 MD
PVP 750 MDLP
Air flow rate (Nl/s) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
100 at optimal supply pressure
item bar Nl/s
180 0 10 20 30 40 50 60 70 80 -KPa
PVP 750 MD 6.0 50 80.0 250.0 180.0 118.8 59.4 42.8 34.2 25.7 18.0 10.2 90
160
PVP 750 MDLP 3.0 110.0 222.2 115.5 75.1 48.8 43.9 35.6 22.0 15.4 8.8 88
140
0
0 10 20 30 40 50 60 70 80
120
PVP 750 MD -Kpa
PVP 750 MDLP
100
ms/l
80
PVP 750 MDLP
60
PVP 750 MD PVP 750 MDLP
180
40
160
20
140
0
10 20 30 40 50 60 70 80 85
120
PVP 750 MD -Kpa
PVP 750 MDLP
100
ms/l
80
60
8 40
20
0
10 20 30 40 50 60 70 80 85
PVP 750 MD -Kpa
PVP 750 MDLP
Evacuation rates (ms/l= s/m3) at different levels of vacuums (-KPa) Max vacuum
Generator Supp. press. Air consumption
at optimal supply pressure
item bar Nl/s
10 20 30 40 50 60 70 80 85 -KPa
PVP 750 MD 6.0 80.0 0.3 0.8 1.8 4.3 7.7 11.8 19.5 33.8 125 90
PVP 750 MDLP 3.0 110.0 0.5 1.3 2.6 5.2 9.2 14.5 21.7 43.4 160 88
8.108
ACCESSORIES FOR VACUUM GENERATORS PVP 150 MD / MDLP ÷ PVP 750 MD / MDLP
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.109
ACCESSORIES FOR VACUUM GENERATORS PVP 150 MD / MDLP ÷ PVP 750 MD / MDLP
of atmospheric air into the vacuum system (tanks, autoclaves, intake systems depression, vacuum cups, etc.), when the generator stops,
guaranteeing the seal and maintaining the level of vacuum reached in use.
The three components described above make up an energy saving kit for the compressed air supply ES (Energy Saving System). In fact, the ES
device acts directly on the generator, making it operate only within the preset vacuum values, thus limiting compressed air supply consumption;
all this entails considerable energy savings.
This kit has been specifically designed for the PVP 150-750 MD/MDLP series of generators.
8
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.110
CONVEYOR ADJUSTABLE VACUUM GENERATORS
Working principle
These vacuum generators operate based on the Venturi principle.
Unlike those previously described, the ejectors with which they are supplied are adjustable, in addition to
having a considerably higher flow diameter.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.111
PVR 25 Quantità di aria aspirata (mc/h) PVR 50 Quantità di aria aspirata (mc/h)
PVR 25 Quantità di aria aspirata (mc/h) PVR 50 Quantità di aria aspirata (mc/h)
ADJUSTABLE
PVR 25 CONVEYOR VACUUM
Quantità di aria aspirata (mc/h) GENERATORS PVR 25 and
PVR 50 PVR
Quantità 50aspirata (mc/h)
di aria
14 40
14
PVR 25 30
35
PVR 50
12
10 40
25
8
3D drawings are available on vuototecnica.net
25
30
m3/h m3/h
m3/h m3/h
12 35
20
10
8
6
20
25
30
15
10
8
6
4
m3/h
m3/h
15
20
25
10
8
6
4
2
m3/h
10
m3/h
15
205
6
4
2
0 105
150
1 2 3 4 5 6 1 2 3 4 5 6
4
2
0 bar 100
5 bar
1 2 3 4 5 6 1 2 3 4 5 6
2 bar bar
0 0
5
PVR 25 1 Quantità
2 di aria
3 soffiata
4 5 6
PVR 50 1 2 3
Quantità 4 soffiata
di aria 5 6
bar bar
0 0
PVR 25 1 Quantità
2 di aria
3 soffiata
4 5 6 PVR 50 1 2 Quantità
3 di aria
4 soffiata
5 6
bar bar
PVR 25 Quantità di aria soffiata PVR 50 Quantità di aria soffiata
40
Quantity of air blown (m3/h) at different90 supply pressures (bar)
PVR 25 40 Quantità di aria soffiata 90 50
PVR
80 Quantità di aria soffiata
35
35
PVR 25 80
70
PVR 50
40
30 90
70
60
80
30
35
40
25 90
60
50
70
25
30 80
m3/h m3/h
m3/h m3/h
35
20
50
40
60
20 70
25
30
15
40
30
50
60
m3/h
m3/h
15
20
25
10
30
20
40
50
10
m3/h
m3/h
15
20
5 20
10
30
40
5
10
15
0 10
0
20
1 2 3 4 5 6 30 1 2 3 4 5 6
0
5
10 bar 0
10 bar
1 2 3 4 5 6 20 1 2 3 4 5 6
bar bar
0
5 0
10
PVR 25 1 Grado
2 di3 vuoto4 5 6 PVR 50 1 2 3Grado di
4 vuoto5 6
bar bar
0 0
PVR 25 1
Grado
2
di3 vuoto4 5 6
PVR 50 1 2 3Grado di
4 vuoto5 6
Level of vacuum (-Kpa) at different supply pressures (bar)
bar bar
PVR 25 Grado di vuoto PVR 50 Grado di vuoto
90 80
PVR 25
PVR 25
Grado di vuoto PVR
PVR 50
Grado di vuoto
90
80 80 50 70
80
70
90 70
80
60
70
60
80
90 60
70
80
50
60
50
70
80 50
-Kpa -Kpa -Kpa
-Kpa -Kpa -Kpa
60
70
40
50
40
60
70 40
50
60
30
40
30
50
60
30
40
50
20
30
20
40
50
-Kpa
-Kpa
20
30
40
10
20
10
30
40
10
0 10
20
30
0
20
30 1 2 3 4 5 6 1 2 3 4 5 6
0
10 bar 0
10
20 bar
20 1 2 3 4 5 6 1 2 3 4 5 6
0 bar bar
0 50 Consumo d'aria
PVR 25 10
1
Consumo
2 3
d'aria4 5 6
10
PVR
1 2 3 4 5 6
7 16
14
18
6
5
14
12
16
7
6 18
5
4 12
10
14
16
Nl/s Nl/s
Nl/s Nl/s
6
5
4 10
3 8
12
14
5
4 8
6
3 10
2 12
Nl/s
Nl/s
46
8
4
3 10
2
1
Nl/s
Nl/s
42
6
3 8
2
1
0 2
40
1 2 3 4 5 6 6 1 2 3 4 5 6
2
1
0 bar 0
2 bar
1 2 3 4 5 6 4 1 2 3 4 5 6
1 bar bar
0 0
2
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
0 0
8.112 1 2 3 4 5 6 1 2 3 4 5 6
bar bar
ADJUSTABLE CONVEYOR VACUUM GENERATORS PVR 100 and PVR 200
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.113
ADJUSTABLE CONVEYOR VACUUM GENERATORS80 PVR 100 and PVR 200
60
60 80
Quantity of air suctioned (m3/h) at different
70 supply pressures (bar)
50
60 70
80
60
50
40 PVR 100 60
70
80
PVR 200
60 50
50
40
3D drawings are available on vuototecnica.net
50
60
m3/h m3/h
m3/h m3/h
30 70
40
50
40
30 40
50
60
30
20
40
m3/h
m3/h
30 30
40
50
20
20
10
20
30
m3/h
m3/h
30 40
10
20
10
0 10
20
30
0
20 1 2 3 4 5 6 1 2 3 4 5 6
10
0 bar 0
10
20 bar
1 2 3 4 5 6 1 2 3 4 5 6
10 bar bar
0 0
10
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
0 0
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
140 200
Quantity of air blown (m3/h) at different supply pressures (bar)
140 180
200
120
140
PVR 100 160
180
200
PVR 200
120
100 140
160
180
140
120 200
100 120
140
80 160
180
m3/h m3/h
m3/h m3/h
120 100
120
100
80 140
60 160
80
100
120
100
80 140
60 60
40 80
m3/h
m3/h
100
120
80
60 40
60
40 80
20
m3/h
m3/h
100
20
40
60
40 60
20 80
0 0
20
1 2 3 4 5 6 40 1 2 3 4 5 6
40 60
20
0 bar 0 bar
1 2 3 4 5 6 20 1 2 3 4 5 6
40
20 bar bar
0 0
1 2 3 4 5 6 20 1 2 3 4 5 6
bar bar
0 0
1 2 3 4 5 6 1 2 3 4 5 6
Level of vacuum (-Kpa) at different supply pressures (bar)
bar bar
80 70
PVR 100 70
PVR 200
80
70 60
70
80
60 70
60
50
60
70
50
80 70
60
50
40
50
-Kpa -Kpa
-Kpa -Kpa
60
40
70 60
50
40
30
40
50
30
60
50
40
30
20
-Kpa
-Kpa
30
40
20
50
40
30
20
20 10
-Kpa
-Kpa
30
10
40
30
20
10
10
20
0
30 0
1 2 3 4 5 6 1 2 3 4 5 6
20
10
0
10
20 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6
bar 10
0 bar
0
10
1 2 3 4 5 6 1 2 3 4 5 6
Air
bar consumption (Nl/s) at different supply pressures (bar)
bar
8 0
1 2 3 4 5 6
0
1 2 3 4 5 6
25
PVRbar 100 35
PVRbar200
25 35
30
20
25 35
30
25
20
25 35
30
15 25
20 20
Nl/s Nl/s
Nl/s Nl/s
15 30
25
20
20 15
10
15 25
20
15
10 10
Nl/s
Nl/s
15
5 20
15
10 10
5
Nl/s
Nl/s
5
15
10
10 5
0 0
5 1 2 3 4 5 6 1 2 3 4 5 6
bar 10
5 bar
0 0
5 1 2 3 4 5 6 1 2 3 4 5 6
bar 5 bar
0 0
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
0 0
8.114 1 2 3 4 5 6 1 2 3 4 5 6
bar bar
CARTRIDGE VACUUM GENERATORS PVR 1 and PVR 4
Cross-housing for
screwdriver
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.115
CARTRIDGE VACUUM GENERATOR PVR 3 OT
Also the construction of this cartridge vacuum generator was necessary in order to meet the demand for
ever smaller and more performing devices in the packaging sector.
The compressed air supply pressure is between 1 and 3 bar, while the maximum level of vacuum is -52
KPa, with a flow rate of 2.6 m3/h.
3D drawings are available on vuototecnica.net
Also the shape of these generators, like the previous ones described, allows for the suction of dust and
small processing waste without clogging problems.
They are made of brass as standard, but upon request they can also be supplied in different metals.
Sp17
Item PVR 3 OT
Intake air flow rate m /h
3
2.2 2.6 2.6 2 1.6
Maximum level of vacuum -KPa 21 37 52 50 47
Final pressure abs. mbar 790 630 480 500 530
Supply pressure bar 1 2 3 4 5
Air consumption Nl/s 1.25 1.8 2.4 3.1 3.6
Temperature of use °C -10 / +60
Noise level dB(A) 78
Weight g 60
Note: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.116
CONVEYOR VACUUM GENERATOR PVR 25 MS, WITH SUPPORT FOR FASTENING TO
VACUUM CUPS
The particular shape of this rectilinear flow vacuum generator allows for the supply of vacuum cups,
especially in the presence of abundant quantities of dust, liquids, sawdust, of various origins, and shavings,
without interference. It can reach a level of vacuum of -70KPa, a suction flow rate of about 10 m3/h, with a
supply pressure of 3 bar.
Protection plate
Vacuum switch item 12 05 11 P item 00 15 341
(upon request)
Silencer
item SSX 1/4”
8
Adapter item 00 15 397
(upon request)
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.117
ACCESSORIES AND SPARE PARTS FOR VACUUM GENERATOR PVR 25 MS
connection
Body (polycarbonate)
Red LED
Three-pole shielded cable
Adjustment Ø3.2 L=1500 mm
screw
Item Description
12 05 11 P Digital micro vacuum switch
Vacuum gauge
sp14
8
SPARE PARTS
8.118
ACCESSORIES FOR CONVEYOR ADJUSTABLE VACUUM GENERATORS
The noise level of Conveyor adjustable vacuum generators, which is always quite high,
can be considerably mitigated by a suitable silencer screwed onto the air exhaust
connection. SSX series silencers can be supplied upon specific request. These are
suitable for all Conveyor vacuum generators.
8.119
VACUUM JET FLOW GENERATORS
Working principle
The compressed air supply blown into a ring chamber concentric to the device, flows at
a very high speed towards the centre of the main pipe, thus forming a cyclonic effect.
The latter creates a vacuum inside the device and leads a great volume of air towards its
3D drawings are available on vuototecnica.net
outlet.
Therefore, a variation of the air supply pressure will modify the level of vacuum and the
amount of sucked air.
Features
The special shape of the flow generators and their straight-flow working principle allow
for the suctioning and handling of various nature products without interference. Vacuum
Jets are in fact suitable for the handling of powders, granulated products, sawdust, corn,
metal chips, liquid or dry food products, etc., or for extracting fumes, coolant mists,
water or oil condensation, etc.
The absence of moving parts allows them to be used continuously, without developing
heat.
They do not require electricity; therefore, they can be used in work environments with
hazardous environments where an ignition source would be dangerous.
Available in anodised aluminium and stainless steel.
Thanks to all these features, a good filtration of the compressed air supply will be
sufficient to make these devices fully maintenance-free.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.120
FLOW GENERATORS VACUUM JET CX 7 and CX 1030
14
14 30
12 Quantity of air suctioned (m3/h) at different
25
supply pressures (bar)
14
12 30
10
CX 7 25
20
30
CX 10
14
12
10 25
8 20
m3/h m3/h
12 15
10
8 25
6 20
15
108 10
6 20
4
m3/h
m3/h
15
8 10
46 5
m3/h
m3/h
15
10
64 5
2
0 0
1 2 3 4 5 6 10 1 2 3 4 5 6
42 5
0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6
bar 5 bar
20
0
1 2 3 4 5 6 1 2 3 4 5 6
0 bar bar
0
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
20 60
Quantity of air blown (m3/h) at different supply pressures (bar)
18
20 60
16
18
20
CX 7 50
60
CX 10
50
14
16
18 40
20 60
12
14 50
16 40
18
m3/h m3/h
m3/h m3/h
10
12 30
14 50
16 40
108 30
12
14 20
86 40
m3/h
m3/h
10 30
12 20
64 10
8
m3/h
m3/h
10 30
42 20
6 10
8
20 0
4 20 1 2 3 4 5 6
6 1 2 3 4 5 6
10
0 bar 0 bar
2 1 2 3 4 5 6 1 2 3 4 5 6
4
10
bar bar
0 0
2 1 2 3 4 5 6
1 2 3 4 5 6
bar 0 bar
0
1 2 3 4 5 6 1 2 3 4 5 6
Level of vacuum (-Kpa) at different supply pressures (bar)
bar bar
16 25
CX 7 CX 10
16
14 25
20
14
16
12 25
20
12
16
14
10 25
15
20
10
14
12
-Kpa -Kpa
8
-Kpa -Kpa
15
20
86
12
10 10
15
10
648
-Kpa -Kpa
10
-Kpa -Kpa
15
5
10
4826
5
10
2
64
0 0
1 2 3 4 5 6 5 1 2 3 4 5 6
402 bar 0 bar
1 2 3 4 5 6 5 1 2 3 4 5 6
bar bar
20 0
1 2 3 4 5 6 1 2 3 4 5 6
Airbarconsumption (Nl/s) at different supply
0 pressures (bar)
bar
0
1 2 3 4 5 6 1 2 3 4 5 6 8
1,8
CX 7bar 2,5
CX bar10
1,8
1,6 2,5
1,6
1,4 2
1,8 2,5
1,4
1,2 2
1,6
1,8 2,5
1,5
1,2
1
1,4 2
1,6
Nl/s
Nl/s Nl/s
1,5
1
0,8
1,2 2
1,4
Nl/s
1
1,5
0,8
0,6
1,21 1
Nl/s
Nl/s
0,6
0,4 1,5
0,8
1 0,5
1
Nl/s
Nl/s
0,4
0,2
0,6
0,8 0,5
1
0,2
0
0,4 0
0,6 1 2 3 4 5 6 0,5 1 2 3 4 5 6
0
0,2 bar 0 bar
0,4 1 2 3 4 5 6 1 2 3 4 5 6
0,5
bar bar
0,20 0
1 2 3 4 5 6 1 2 3 4 5 6
0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6 8.121
bar bar
FLOW GENERATORS VACUUM JET CX 13 and CX 19
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.122
FLOW GENERATORS VACUUM JET CX 13 and CX 19
60 100
60 100 90
50
Quantity of air suctioned (m3/h) at different supply pressures (bar)
80
90
60 100
50
40
60
CX 13 70
80
90
100
CX 19
50 60
70
40 80
m3/h m3/h
30 50
60
50 70
40 80
30 40
50
60
20 70
40 30
40
m3/h
m3/h
30 50
20 60
20
30
10 40
m3/h
m3/h
30 50
20 10
20
10 30
40
0 0
10
20 1 2 3 4 5 6 20 1 2 3 4 5 6
10 30
0 bar 0 bar
1 2 3 4 5 6 10 1 2 3 4 5 6
20
10
0 bar 0 bar
10
1 2 3 4 5 6 1 2 3 4 5 6
0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
80 160
Quantity of air blown (m3/h) at different supply pressures (bar)
80
70 160
140
70
80
CX 13 140
160
CX 19
60 120
60
80
70
50 120
160
140
100
50
70
60
40 100
140
120
80
m3/h m3/h
m3/h m3/h
40
60
50
30 80
120
100
60
30
50
40
20 60
100
80
40
m3/h
m3/h
20
40
30
10 40
80
60
20
m3/h
m3/h
10
30
20
0 20
60
40
0
1 2 3 4 5 6 1 2 3 4 5 6
0
20
10 bar 0
40
20 bar
1 2 3 4 5 6 1 2 3 4 5 6
bar bar
10
0 20
0
1 2 3 4 5 6 1 2 3 4 5 6
0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6
bar Level of vacuum (-Kpa) at different supply pressures (bar)
bar
20 18
18
CX 13 16
CX 19
20 18
16
18
20 14
16
18
14
16
18 12
14
16
20 18
12
14
16 10
12
18 14
16
-Kpa -Kpa -Kpa -Kpa
10
-Kpa -Kpa
12
14 8
10
16 12
8 14
10
12
14 6
8
10
6
8 12
10
-Kpa -Kpa
12 4
6
4
6 8
10
8
10
2 2
4
6
4 8
6
8
0
2 0
2
4
4 1 2 3 4 5 6 6 1 2 3 4 5 6
6
0 bar 0 bar
2 2
4
4 1 2 3 4 5 6 1 2 3 4 5 6
bar bar
0 0
2
2
1 2 3 4 5 6 1 2 3 4 5 6
0 bar Air consumption (Nl/s) at different supply
0 pressures (bar)
bar
1 2 3 4 5 6 1 2 3 4 5 6 8
7
CXbar13 14
CXbar19
7 14
6 12
7
6 14
12
5 10
7 14
12
6
5 10
4 8
6 12
Nl/s Nl/s
Nl/s Nl/s
5
4 10
8
3 6
5 10
8
4
3 6
2 4
Nl/s
Nl/s
4 8
6
3
2 4
1 2
Nl/s
Nl/s
3 6
4
2
1 2
0 0
1 2 3 4 5 6 1 2 3 4 5 6
2 4
2
1
0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6
1 bar 2 bar
0 0
1 2 3 4 5 6 1 2 3 4 5 6
0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6 8.123
bar bar
FLOW GENERATORS VACUUM JET CX 25, CX 38 and CX 50
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.124
FLOW GENERATORS VACUUM JET CX 25, CX 38 and CX 50
Quantity of air suctioned (m3/h) at different supply pressures (bar)
160
CX 25 350
CX 38 450
CX 50
/h3/hm3/h
/h3/hm3/h
/h3/hm3/h
100
80 200
250 250
200 200
250
80 150 300
m3/h m3m
m3/h m3m
m3/h m3m
100
80
60 200
150
200 150
200
250
60 150
100
80
60
40 150
100 100
150
200
40 150
100
60
40 50 100
20 50
100
150
50
20 100 50
40 50
20
0 0 0
50
100
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
0 0 0
50
20
0 1 2 3 bar 4 5 6 0 1 2 3 bar 4 5 6 0
50 1 2 3 bar 4 5 6
1 2 3 bar 4 5 6 1 2 3 bar 4 5 6 1 2 3 bar 4 5 6
0 bar 0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
bar Quantity of air blown (m3/h) at
bardifferent supply pressures (bar) bar
250
250
CX 25 450
450
CX 38 600
600
CX 50
250 400
450 600
400 500
200
250 350
400
450 500
600
200 500
350
200 300 400
350
400
150 300 400
500
200 250
300 400
150 350
/h3/hm3/h
/h3/hm3/h
/h3/hm3/h
m3/h m3m
m3/h m3m
200 300
150
100 150
200
250 200
100
150 200
300
100
150
200 200
50
100 100 100
50 50
100
150 100
200
50
50 100
0 0
50
100 0
50 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
0 0 0
100
0 1 2 3 bar 4 5 6 0
50 1 2 3 bar 4 5 6 0 1 2 3 bar 4 5 6
1 2 3 bar 4 5 6 1 2 3 bar 4 5 6 1 2 3 bar 4 5 6
0 bar 0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
bar bar bar
-Kpa-Kpa
-Kpa-Kpa
8 6 5
10
8 4
5
6 6
8 6
-Kpa -Kpa
-Kpa -Kpa
-Kpa -Kpa
6 4
6
8 4 3
4
5
6
4
4
6 3
4 4 2
3
4
6
4 2 2
2
2
4 1
2
3
2
4 2 1
2
0 0 0
1
2
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
0 0
2 0
2
0 1 2 3 bar 4 5 6 0 1 2 3 bar 4 5 6 0
1 1 2 3 bar 4 5 6
1 2 3 bar 4 5 6 1 2 3 bar 4 5 6 1 2 3 bar 4 5 6
0 bar 0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
bar bar bar
Nl/sNl/s
Nl/s Nl/s
10 15 20
25
8
10 20
12 15
20 15
Nl/s
Nl/s
Nl/s
8 15
15
6
8 10 20
10 15
10
Nl/s
Nl/s
Nl/s
6 10
15
4
6 10 10
8 15
4 5 10
5
2
4 5
10
6
5
2 5 10
5
0
2 0 0
4
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
0 0
5 0
5
0
2 1 2 3 bar 4 5 6 0 1 2 3 bar 4 5 6 0 1 2 3 bar 4 5 6
1 2 3 bar 4 5 6 1 2 3 bar 4 5 6 1 2 3 bar 4 5 6
0 bar 0 bar 0 bar
1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6
bar bar bar
8.125
MINI PNEUMATIC PUMP SETS DOP 06 and DOP 10
Mini pneumatic pump sets are small independent vacuum-producing units, exclusively
supplied with compressed air, with reduced size.
They are composed of:
- A small welded sheet steel tank
3D drawings are available on vuototecnica.net
Generator
For Ø8 ext. hose
Cock for
condensation
discharge item 13 02 11
DOP 10 PVP 12 MX 10 PVP 12 MX DOP 20 90 100 G3/8” 210 95 240 310 620 12.9
DOP 10 PVP 25 MX 10 PVP 25 MX DOP 20 90 100 G3/8” 210 95 240 310 620 13.2
Note: Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.126
MINI PNEUMATIC PUMP SETS DOP 20
This mini pump set is set apart from the previously ones for the vacuum generator
installed, as well as for the tank volume.
Vacuum generators of the series PVP… MDX ES are in fact equipped with an energy
saving device which automatically maintains the preset level of vacuum inside the tank.
Vacuum gauge item 09 05 10 Coaxial servo-controlled ball supply valve Vacuum interception valve
For Ø8 ext. hose
item 13 03 11
Regulator filter Pressure gauge item 09 03 25
Generator
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.127
PNEUMATIC PUMP SETS 25, DOP 50 and DOP 100
Pneumatic pump sets are self-contained vacuum production units, fed exclusively by
compressed air.
They are composed of:
- A welded sheet steel tank
3D drawings are available on vuototecnica.net
- A compressed air vacuum generator of the series PVP … MDX ES, equipped
with an energy saving device
- A vacuum gauge for reading the level of vacuum
- A manual valve for vacuum interception
- A suction filter with FC series paper cartridge
- A pressure regulator with filter and pressure gauge
- A shut off valve to intercept compressed air
- A cock for condensation drainage from the tank
The level of vacuum in the tank, previously set with the vacuum switch in
the generator, is automatically maintained. The pneumatic pump sets are
normally used to handle particularly heavy or valuable loads, as it allows
vacuum cups to maintain grip for a certain period of time (varies according
to tank capacity) even during unexpected absence of power. These pump sets
are recommended for multi-point applications, to centralise vacuum.
In both cases, use of the pump set is especially advantageous under the profile of
energy savings as the generator only operates when a vacuum is required by the
utility machine.
The pneumatic pump sets do not require any electrical current but only compressed
air at 4-6 bar pressure. Recommended in working environments where ignition sources
could cause a fire hazard.
Vacuum
interception valve
Filter FC 20 Generator
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.128
PNEUMATIC PUMP SETS DOP 50
Vacuum
interception valve
Generator
Filter FC 20
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.129
PNEUMATIC PUMP SETS DOP 100
3D drawings are available on vuototecnica.net
Vacuum
interception valve
Generator
Filter FC 30
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.130
PNEUMATIC PUMP SETS DOP 150 and DOP 300
Generator
For Ø15 ext. hose
Vacuum
interception valve
Filter FC 38
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.131
PNEUMATIC PUMP SETS DOP 300
3D drawings are available on vuototecnica.net
Generator
For Ø15 ext. hose
Vacuum
interception valve
Filter FC 55
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.132
PNEUMATIC DEVICES FOR THE POWER SUPPLY OF MINI PNEUMATIC PUMP SETS
DOP 06, DOP 10, DOP 20 AND PUMP SETS DOP 25, DOP 50, DOP 100, DOP 150 and DOP 300
The pneumatic equipment of the mini pump sets and pump sets is sized so as to
guarantee the right amount of compressed air supply to the vacuum generators installed
on them, at a correct, constant and continuous pressure.
It is composed of:
PNEUMATIC DEVICES FOR THE POWER SUPPLY OF MINI PNEUMATIC PUMP SETS DOP
06, DOP 10 and DOP 20
For Ø8 ext. hose
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.133
PNEUMATIC DEVICES FOR THE POWER SUPPLY OF PNEUMATIC PUMP SETS DOP 25,
DOP 50 and DOP 100
3D drawings are available on vuototecnica.net
PNEUMATIC DEVICES FOR THE POWER SUPPLY OF PNEUMATIC PUMP SETS DOP 150
and DOP 300
For Ø15 ext. hose
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
8.134
SPECIAL PRODUCTS FOR VACUUM GENERATORS
8.135
OCTOPUS VACUUM GRIPPING SYSTEMS
9
OCTOPUS VACUUM GRIPPING SYSTEM - GENERAL DESCRIPTION
WOOD CONSTRUCTION
PALLETS GLASS
CAN
9
TECHNIQUES USED FOR THE CREATION OF OCTOPUS SUCTION PLATES:
The calibrated holes drilled onto the aluminium suction plates, based Shut-off valves, when properly calibrated, allow a certain quantity of
on their number and cross-section, allows for the selection of the fluid to go through; afterwards, if the fluid continues to go through,
exact flow rate of the vacuum generator to be used: in fact, when the they automatically close.
vacuum differential is reached with all calibrated holes of the open When applied on the section plates, without a load to be gripped or in
suction plate on the OCTOPUS system is 0 mbar, this means that the presence of a defective grip on foam rubber, they automatically
the flow rate of the vacuum generator used is correct, but due to the close suction, thus preventing the level of vacuum from lowering on
operating principle of the OCTOPUS systems, it will be necessary to the remaining holes or vacuum cups that are regularly being gripped.
increase it to obtain a vacuum differential greater than 0 mbar. This feature reduces the vacuum generator flow rate compared
It will therefore be necessary to use a generator with a higher flow to standard OCTOPUS systems, to the benefit of energy savings.
rate to obtain a vacuum differential greater than the greater the flow Moreover, the particular shape of our shut-off valves allows the use of
rate of the generator used. In this way, it is possible to determine the gripping surfaces in any position.
which percentage of the surface of the load to be gripped can remain
uncovered during the gripping phase, in compliance with the safety
parameters.
This technique requires a greater expenditure of energy with respect
to the use of shut-off valves.
9.01
OCTOPUS GRIPPING SYSTEM COMPOSITION AND
RELATIVE IDENTIFICATION CODES
The OCTOPUS systems described on the following pages are equipped as standard with PX suction plates.
Should you want to replace these plates with others with different features you will have to modify the
identification codes as described in this page.
3D drawings are available on vuototecnica.net
Example of a standard OCTOPUS system composition with a gripping plane of 300x400 mm:
15
With suction plate PX item SO 30 40 X
With suction plate P2X item SO 30 40 2X
30
15
With suction plate PX and shut-off valves item SO 30 40 XE
With suction plate P2X and shut-off valves item SO 30 40 2XE
30
20
With suction plate PH item SO 30 40 H
With suction plate P2H item SO 30 40 2H
30
15
With suction plate PY item SO 30 40 Y
With suction plate P2Y item SO 30 40 2Y
9 30
15
With suction plate PY and shut-off valves item SO 30 40 Y2E
With suction plate P2Y and shut-off valves item SO 30 40 2Y2E
30
9.02
OCTOPUS GRIPPING SYSTEM COMPOSITION AND
RELATIVE IDENTIFICATION CODES
30
Example of an order for an OCTOPUS system with suction plate P2Y, complete with vacuum generator:
1 PVP 150 MD PO
1 SO 30 40 2Y
Example of an order for an OCTOPUS system with suction plate P2V, complete with silicone vacuum cups vacuum generator:
1 PVP 150 MD PO
1 SO 30 40 2V
36 01 40 42 S
Example of an order for an OCTOPUS system with suction plate PX and shut-off valves, complete with vacuum generator:
1 PVP 150 MD PO
1 SO 30 40 XE
9.03
OCTOPUS VACUUM GRIPPING SYSTEM
3D drawings are available on vuototecnica.net
Compressed
air connection
Item SO 15 20 MX
Suction plate item PX 15 20
Gripping force Kg 21.2
Vacuum generator item N°1 PVP 25 MX PO
Maximum supply pressure bar 6
9 Maximum level of vacuum -KPa 90
Air consumption at 6 bar Nl/s 3.2
Intake air flow rate m3/h 31.0
Temperature of use °C -20 / +80
Weight Kg 2.1
P Connection for compressed air tube Ø ext. 8
R Exhaust connection Ø N° 4 x G1/4”
NOTE: The vacuum generator indicated in the table are included with the OCTOPUS system
NOTE: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.04
OCTOPUS VACUUM GRIPPING SYSTEM
Item SO 20 30 X SO 20 40 X SO 20 60 X
Suction plate item PX 20 30 PX 20 40 PX 20 60
Gripping force Kg 42.4 56.6 84.8
Fitted for vacuum generator item N°1 PVP 100 M PO N°1 PVP 140 M PO N°1 PVP 200 M PO
Maximum supply pressure bar 6 6 6
Maximum level of vacuum -KPa 90 90 90
Air consumption at 6 bar Nl/s 9.8 13.0 19.4
Intake air flow rate m3/h 108.0 152.0 200.0
Temperature of use °C -20 / +80 -20 / +80 -20 / +80
Weight Kg 7.0 8.6 10.7 9
A 300 400 600
E 74 96 96
F 20 70 170
G 16 66 166
H 124 146 146
P Connection for compressed air tube Ø ext. 15 15 15
NOTE: The code SO .. .. X only identifies the OCTOPUS system body with relative suction plate PX.
The vacuum generator indicated in the table is not included with the OCTOPUS system and therefore must be ordered separately with its own code.
NOTE: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.05
OCTOPUS VACUUM GRIPPING SYSTEM
3D drawings are available on vuototecnica.net
Compressed
air connection
Item SO 30 30 X SO 30 40 X SO 30 50 X SO 40 40 X SO 40 60 X
Suction plate item PX 30 30 PX 30 40 PX 30 50 PX 40 40 PX 40 60
Gripping force Kg 63.6 84.8 106.0 113.1 169.6
Fitted for vacuum generator item N°1 PVP 150 MD PO N°1 PVP 150 MD PO N°1 PVP 300 MD PO N°1 PVP 300 MD PO N°1 PVP 300 MD PO
Maximum supply pressure bar 6 6 6 6 6
Maximum level of vacuum -KPa 90 90 90 90 90
Air consumption at 6 bar Nl/s 16.0 16.0 32.0 32.0 32.0
Intake air flow rate m3/h 200.0 200.0 400.0 400.0 400.0
Temperature of use °C -20 / +80 -20 / +80 -20 / +80 -20 / +80 -20 / +80
Weight Kg 11.5 12.5 15.0 17.0 19.0
9 A 300 400 500 400 400
B 300 300 300 400 600
C 138 138 158 158 158
E 88 88 108 108 108
F 50 100 150 100 200
G 15 15 15 65 65
P Connection for compressed air tube Ø ext. 15 15 15 15 15
NOTE: The code SO .. .. X only identifies the OCTOPUS system body with relative suction plate PX.
The vacuum generator indicated in the table is not included with the OCTOPUS system and therefore must be ordered separately with its own code.
NOTE: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.06
OCTOPUS VACUUM GRIPPING SYSTEM
Pressure Vacuum
gauge gauge
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.07
SMALL OCTOPUS VACUUM GRIPPING SYSTEMS
3D drawings are available on vuototecnica.net
air connection
air connection
air connection
Compressed
Compressed
Compressed
Vacuum
generator
Vacuum Vacuum
generator generator
Item SO DO 10 X SO 08 08 X SO 07 12 X
Suction plate item PX DO 10 PX 08 08 PX 07 12
Gripping force Kg 4 3 4
9 Vacuum generator item M14PO M14PO M14PO
Maximum supply pressure bar 5 5 5
Maximum level of vacuum -KPa 85 85 85
Air consumption at 6 bar Nl/s 2.5 2.5 2.5
Intake air flow rate m3/h 12.6 12.6 12.6
Temperature of use °C -20 / +80 -20 / +80 -20 / +80
Weight Kg 0.5 0.4 0.7
P Connection for compressed air tube Ø ext. 6 6 6
NOTE: The vacuum generator indicated in the table is included with the OCTOPUS system.
NOTE:
All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.08
ROUND OCTOPUS VACUUM GRIPPING SYSTEM
Vacuum
gauge
Pressure
gauge
Vacuum
generator
Compressed
air connection
Item SO DO 35 X SO DO 50 X
Suction plate item PX DO 35 PX DO 50
Gripping force Kg 65.4 139.6
Fitted for vacuum generator item N°1 PVP 170 M PO N°1 PVP 300 MD PO
Maximum supply pressure bar 6 6
Maximum level of vacuum -KPa 90 90
Air consumption at 6 bar Nl/s 16.3 32.0
Intake air flow rate m3/h 182.0 400.0
Temperature of use °C -20 / +80 -20 / +80
Weight Kg 9.5 17.0
A 120 270
B 264 200 9
C 43 150
D Ø 350 500
E 96 108
H 146 158
I 8.5 10.5
P Connection for compressed air tube Ø ext. 15 15
NOTE: The code SO DO . X only identifies the OCTOPUS system body with relative suction plate PX.
The vacuum generator indicated in the table is not included with the OCTOPUS system and therefore must be ordered separately with its own code.
NOTE: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.09
STANDARD SUCTION PLATES PX and P2X FOR OCTOPUS SYSTEMS
The suction plates PX described on this page are installed as standard on all OCTOPUS systems and,
therefore, can be supplied as a spare or replacement part.
They are made with anodised aluminium sheets with calibrated holes equidistant from each other and
coated with a special perforated foam rubber with two different thicknesses: 15 mm for suction plates
3D drawings are available on vuototecnica.net
of the PX range; 30 mm, for special suction plates of the P2X range. The foam rubber is also perforated
at the calibrated holes, but its holes have a diameter of 10-15 mm. The use of calibrated holes allows for
exact calculation of the flow rate of the vacuum generator to be used, to ensure that, even in the presence
of losses due to transpiration or even in case of failure to cover the object to be gripped, a minimum
sufficient level of vacuum remains for gripping and handling the load.
Their lifting force was calculated considering a level of vacuum of at least -75 Kpa, the total surface of the
holes within the foam rubber and a factor of safety 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.10
SPECIAL PH and P2H SUCTION PLATES FOR OCTOPUS SYSTEMS FOR GRIPPING
EMPTY CANS, TINS, JARS AND VIALS WITHOUT LIDS OR CAPS
The special suction plates illustrated and described on this page can be installed on OCTOPUS
systems to replace the PX and P2X plates.
They are made of anodised aluminium sheets with holes equidistant from each other and
coated with a special sponge rubber, microperforated at the holes in the aluminium sheet, in
3D drawings are available on vuototecnica.net
two different thicknesses: 15 mm for PH suction plates and 30 mm for P2H plates.
The use of calibrated holes makes it possible to calculate the flow rate of the vacuum
generator to be installed on the OCTOPUS SYSTEM, to ensure that, even in the
presence of losses due to transpiration or the absence of some objects to be
picked up, there is always a minimum vacuum value, sufficient to grip even the
few remaining containers.
The use of these suction plates is recommended for gripping and handling empty
cans, tins, vials and jars made of various materials and without lids or caps.
The lifting force of the container will be directly proportional to the degree of vacuum
generated on the surface of the mouth of the can or vial to be picked up.
Note: These plates are not suitable for picking up empty plastic or glass water and wine bottles.
All flexible containers must be previously vacuum tested to avoid the risk of implosion.
Surface (S)
Example of the calculation of the force applied to the container with mouth
diameter 60 mm:
60
SxP 28,26 cm2 x 0,75 Kg/cm2
F= F= = 7,06 Kg
η 3
Where: Where:
F = Lifting force expressed in Kg;
S = Surface area of the container mouth expressed in cm2; S = 28,26 cm2;
P = Force exerted by atmospheric pressure, P = 0,75 Kg/cm2 (value developed from a level
depending on the level of vacuum, expressed in Kg/cm2; of vacuum of -750 mbar);
η = Factor of safety. η = 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.10-110
STANDARD SUCTION PLATES WITH SHUT-OFF VALVES PXE and P2XE
FOR OCTOPUS SYSTEMS
The suction plates described on this page are the same as the previously described
PX and P2X, but with the addition of shut-off valves inserted in each hole. In absence
of an object to grip or in case of a defective grip of the foam rubber, the shut-off
valves automatically close the suction inlet, thus preventing the level of vacuum from
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.11
SPECIAL SUCTION PLATES PY and P2Y FOR OCTOPUS SYSTEMS
Compared to the standard ones, when given the same gripping surface, these suction
plates develop a greater force (item PY) and can grip even very rough and uneven
surfaces (item P2Y).
They are made with anodised aluminium with calibrated holes and coated with special
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.12
SPECIAL SUCTION PLATES WITH SHUT-OFF VALVES PY2E and P2Y2E
FOR OCTOPUS SYSTEMS
The suction plates described on this page are the same as the previously described
PY and P2Y, but with the addition of shut-off valves inserted in each hole. In absence
of an object to grip or in case of a defective grip of the foam rubber, the shut-off
valves automatically close the suction inlet, thus preventing the level of vacuum from
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.13
SPECIAL SUCTION PLATES PZ and P2Z FOR OCTOPUS SYSTEMS
Among all the suction plates described up to now, these are the ones which develop the
greatest lifting force given the same gripping surface and level of vacuum. Moreover, the
P2Z version is also able to grip very rough and uneven surfaces.
They are made with light alloys, equipped with calibrated holes and coated with
3D drawings are available on vuototecnica.net
special foam rubber with slot holes, with two different thicknesses. They are perfectly
interchangeable with the standard suction plates.
Their lifting force has been calculated considering a level of vacuum of at least -75 Kpa,
the total surface of the slot holes within the foam rubber and a safety factor 3.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.14
VACUUM CUP SUCTION PLATES PV and PV2 FOR OCTOPUS SYSTEMS
These suction plates provided with vacuum cups have been designed
to ensure a better grip on uneven and very flexible surfaces (pasta
or candy bags, blister or skin-film packs, thin cardboard boxes, etc.),
which are difficult to grip with suction plates coated with foam rubber.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.15
VACUUM CUP SUCTION PLATES PV2 FOR OCTOPUS SYSTEMS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.16
VACUUM CUP SUCTION PLATES WITH SHUT-OFF VALVES PVE and P2V2E
FOR OCTOPUS SYSTEMS
The suction plates described on this page are the same as the
previously described PY and P2V, but with the addition of shut-off
valves inserted in each vacuum cup support connection. In absence
of an object to grip or in case of a defective grip of the cup, the
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.17
VACUUM CUP SUCTION PLATES WITH SHUT-OFF VALVES P2V2E
FOR OCTOPUS SYSTEMS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.18
BAG GRIPPING SUCTION PLATES PJ
FOR OCTOPUS SYSTEMS
These suction plates have been designed to allow gripping paper or plastic bags
containing powders, granulated products, bulk products or liquids. These suction plates
are associated with OCTOPUS systems that fully exploit their performance. They are made
with anodised aluminium and are provided with a special foam rubber seal. They are
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.19
OCTOPUS VACUUM GRIPPING BARS - GENERAL DESCRIPTION
These bars have been created to further facilitate the installation of OCTOPUS vacuum gripping systems on palletising robots. They
are based on the same operating principle and, in addition to the advantages and technical features of the standard OCTOPUS, are
equipped with a grooved support plate to allow quick installation on the machine and easy positioning with respect to the load to be
gripped.
3D drawings are available on vuototecnica.net
2
3
9
9
9.20
3D drawings are available on vuototecnica.net
COMPOSITION OF THE OCTOPUS GRIPPING BARS
Or:
4
9
9.21
OCTOPUS VACUUM GRIPPING BARS
3D drawings are available on vuototecnica.net
connection G1/4”
Compressed air connection P
Item BO O8 60 X BO O8 80 X BO O8 100 X
Suction plate item PX 08 60 PX O8 80 PX O8 100
Gripping force Kg 31.7 42.2 54.1
Fitted for vacuum generators item N°2 PVP 25 MX PBO N°2 PVP 25 MX PBO N°2 PVP 25 MX PBO
Maximum supply pressure bar 6 6 6
Maximum level of vacuum -KPa 90 90 90
Air consumption at 6 bar Nl/s 6.4 6.4 6.4
Intake air flow rate m3/h 62 62 62
Temperature of use °C -20 / +80 -20 / +80 -20 / +80
Weight Kg 6 8 10
A 600 800 1000
B 80 80 80
9 C 21 21 21
D 50 50 50
E 5.2 5.2 5.2
F 4.8 4.8 4.8
G 10 10 10
H 112 112 112
P Connection for compressed air tube Ø ext. 8 8 8
NOTE: The code BO 08 .. X identifies the body of the OCTOPUS bar with relative suction plate PX, the grooved support plate and the vacuum generators indicated in the table.
Add the letters CD to the item for an Octopus bar supplied without vacuum generators and with closing plates with distributor item 00 BO 07 assembled (Example: BO 08 80 X CD).
NOTE: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.22
OCTOPUS VACUUM GRIPPING BARS
Item BO 12 40 X BO 12 60 X BO 12 80 X
Suction plate item PX 12 40 PX 12 60 PX 12 80
Gripping force Kg 25.7 42.2 56.3
Fitted for vacuum generators item N°1 PVP 25 MX PBO N°2 PVP 25 MX PBO N°2 PVP 25 MX PBO
Maximum supply pressure bar 6 6 6
Maximum level of vacuum -KPa 90 90 90
Air consumption at 6 bar Nl/s 3.2 6.4 6.4
Intake air flow rate m3/h 31 62 62
Temperature of use °C -20 / +80 -20 / +80 -20 / +80
Weight Kg 4.5 8.1 10.8
A 400 600 800
B 120 120 120
C 21 21 21 9
D 90 90 90
E 5.2 5.2 5.2
F 4.8 4.8 4.8
G 10 10 10
H 112 112 112
P Connection for compressed air tube Ø ext. 8 8 8
NOTE: The code BO 12 .. X identifies the body of the OCTOPUS bar with relative suction plate PX, the grooved support plate and the vacuum generators indicated in the table.
Add the letters CD to the item for an Octopus bar supplied without vacuum generators and with closing plates with distributor item 00 BO 07 assembled (Example: BO 12 60 X CD).
NOTE: All vacuum values indicated in the table are valid at the normal atmospheric pressure of 1013 mbar and obtained with a constant supply pressure.
Vacuum generator supply must be carried out with non-lubricated compressed air, 5 micron filtration, in accordance with standard ISO 8573-1 class 4.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.23
OCTOPUS VACUUM GRIPPING BARS
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.24
STANDARD SUCTION PLATES PX and P2X FOR OCTOPUS GRIPPING BARS
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.25
VACUUM CUP SUCTION PLATES PV FOR OCTOPUS GRIPPING BARS
These suction plates provided with vacuum cups have been designed
to ensure a better grip on uneven and very flexible surfaces (pasta
or candy bags, blister or skin-film packs, thin cardboard boxes, etc.),
which are difficult to grip with suction plates coated with foam rubber.
3D drawings are available on vuototecnica.net
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.26
SUCTION PLATES WITH SHUT-OFF VALVES PXE and P2XE
FOR OCTOPUS GRIPPING BARS
The suction plates described on this page are the same as the
previously described PX and P2X, but with the addition of shut-
off valves inserted in each hole. In absence of an object to grip or
in case of a defective grip of the foam rubber, the shut-off valves
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.27
VACUUM CUP SUCTION PLATES WITH SHUT-OFF VALVES PVE
FOR OCTOPUS GRIPPING BARS
The suction plates described on this page are the same as the
previously described PY and P2V, but with the addition of shut-off
valves inserted in each vacuum cup support connection. In absence
of an object to grip or in case of a defective grip of the cup, the shut-
3D drawings are available on vuototecnica.net
off valves automatically close the suction inlet, thus preventing the
level of vacuum from decreasing on the other gripping vacuum cups.
This feature reduces the vacuum generator flow rate compared to
standard OCTOPUS gripping bars with calibrated holes, to the benefit
of energy savings. Their particular shape of our shut-off valves allows
the use of the gripping surfaces in any position.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.28
LOCKING PLATE WITH DISTRIBUTOR FOR
OCTOPUS GRIPPING BARS WITHOUT VACUUM GENERATOR
The locking plates with distributor described on this page have
been designed to connect an OCTOPUS gripping bar to a remotely
installed vacuum generator or to an alternative vacuum source.
The plate, made of anodised aluminium, is fastened with screws
Locking plate
Vacuum generator
9.29
LOCKING PLATE WITH DISTRIBUTOR FOR
OCTOPUS GRIPPING BARS WITHOUT VACUUM GENERATOR
3D drawings are available on vuototecnica.net
Vacuum
connection
Vacuum
connection
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.30
FLANGE FIXING SUPPORT FOR OCTOPUS SYSTEMS
WITHOUT VACUUM GENERATOR
The fixing supports described on this page have been designed
to connect an OCTOPUS system to a remotely installed vacuum
generator or to an alternative vacuum source.
The supports, made with anodised aluminium, have two flanges: one
Item S0 00 02
Item S0 00 05
Item S0 00 06
A B C D E F G H I L M N Weight
Item
Ø Ø Kg
SO 00 02 100 100 210 80 10 194 8 76 12 50 G1” 1/2 8.5 2.8
SO 00 05 150 120 150 130 10 134 8 96 12 75 G2” 8.5 4.2
SO 00 06 150 145 150 130 10 134 8 121 12 75 G2” 1/2 8.5 4.3
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.31
ACCESSORIES AND SPARE PARTS FOR OCTOPUS GRIPPING SYSTEMS AND BARS
Item Description
12 10 10 Digital vacuum switch
Item Description
Electrical connection cable with M8 - 4 pin axial connector
00 12 20
for digital vacuum switch length 5 m
Item Description
Electrical connection cable with M8 - 4 pin radial connector
00 12 21
for digital vacuum switch length 5 m
Item Description
09 03 15 Vacuum gauge
Item Description
09 03 25 Pressure gauge
9.32
ACCESSORIES AND SPARE PARTS FOR OCTOPUS GRIPPING SYSTEMS AND BARS
Silencer
9.33
ACCESSORIES AND SPARE PARTS FOR OCTOPUS GRIPPING SYSTEMS AND BARS
00 SO 05 25 SO 15 20 - BO 08 60 - BO 08 80 - BO 08 100 - BO 08 120
BO 12 40 - BO 12 60 - BO 12 80 - BO 12 100 - BO 12 120 - BO 12 140
00 SO 10 50 SO 20 30 - SO 20 40 - SO 20 60 - SO DO 35
00 SO 14 80 SO 30 30 - SO 30 40 - SO 30 50 - SO 40 40
SO 40 60 - SO DO 50 - SO 40 100 - SO 60 80
SO 60 120 - SO 80 100
Sp17
Sp13
Shut-off valves
A B d D E H Ch Weight Support
9 Item
Ø Ø Ø Ø g material
14 01 06 G1/4” G1/8” 3.25 15 18 28 12 10 aluminium
Minimum trigger flow = 1.5 m /h
3
Minimum level of vacuum = -250 mbar
A B d D E H Ch Weight Support
Item
Ø Ø Ø Ø g material
Sp
14 01 07 G3/8” G1/4” 4.50 20 25 35 17 24 aluminium
Minimum trigger flow = 4 m3/h Minimum level of vacuum = -250 mbar
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
9.34
SPECIAL OCTOPUS GRIPPING SYSTEM PRODUCTS
mm 180x210 - SO 18 21 2C X mm 70x200 - SO 07 20 X
mm 200x1000 - SO 20 100 X
9.35
SPECIAL OCTOPUS GRIPPING SYSTEM PRODUCTS
3D drawings are available on vuototecnica.net
9.36
SPECIAL OCTOPUS GRIPPING SYSTEM PRODUCTS
9.37
SPECIAL OCTOPUS GRIPPING SYSTEM PRODUCTS WITH 3D PRINTER
3D drawings are available on vuototecnica.net
NOTE: Octopus gripping systems made with 3D printer can be supplied in colours: blue, black, white and red.
9.38
OCTOPUS VACUUM GRIPPING Company
SYSTEM QUESTIONNAIRE
For a correct dimensioning of an octopus vacuum gripping Address
system, it is important to know and assess the features of the
load to be handled.
For this reason, please fill out the following form and send it Post code / City Country
Description of product:
Other
%
9.39
OCTOPUS VACUUM GRIPPING SYSTEM QUESTIONNAIRE
3D drawings are available on vuototecnica.net
Size A B H H1 C D ΔH ΔA Weight
Minimum mm mm mm mm mm mm mm mm kg
Maximum mm mm mm mm mm mm mm mm kg
9.40
OCTOPUS VACUUM GRIPPING SYSTEM QUESTIONNAIRE
16) What can the maximum overall dimensions of the Octopus gripping system be, related to your needs?
X mm Y mm Z mm
%
9.41
OCTOPUS VACUUM GRIPPING SYSTEM QUESTIONNAIRE
3D drawings are available on vuototecnica.net
If you selected a pneumatic vacuum generator, indicate the characteristics of the available compressor:
Installed power kW
Maximum compressed air pressure bar
19) At which height above sea level is the Octopus system to be installed?
We can perform tests for gripping and handling on samples of products supplied by you and can send you videos/images relative to tests
performed.
22) Contact
9
%
9.42
GRAPHIC DIVISION
10
10
3D drawings are available on vuototecnica.net
GRAPHIC DIVISION
The experience and production capacity of Vuototecnica has originated a division specially dedicated to the graphics and printing sector. A
reference entity, ranging from engineering to services, that offers innovative and advantageous technical solutions under every point of view:
performance, reliability, duration and operational economy. A significant demonstration of the Graphic Division specialisation is represented by
the new range of products among which:
VACUUM CYLINDERS
By assembling a vacuum cup onto their perforated stem and creating a vacuum, the cup will quickly come into contact with the sheet or the
object to be handled and it will automatically lift it, holding it until the vacuum is excluded. Thanks to all these features, this range of cylinders
combined with cups are particularly recommended for separating sheets of paper or plastic. Advantages include: high speed operation,
automatic compensation of the height of the objects to be lifted, non-rotating stems and extremely easy fixing. These vacuum cylinders are
illustrated and described on the following pages.
VACUUM CUPS
These come in a large variety of shapes and sizes, to guarantee a quick and safe grip and they can be provided in anti-abrasion natural para
rubber, nitrile or oil-resistant rubber, silicone, Viton, polyurethane and other compounds, according to the requirements.
Vacuum cups are described in detail in Chapter 1. This chapter on the other hand will focus on disc cups only.
10
10.01
TABLE FOR PNEUMATIC SUCTION PUMP SELECTION
3D drawings are available on vuototecnica.net
10.02
SMALL PNEUMATIC SUCTION PUMPS PA
The assembly of a pressure adjuster equipped with pressure gauge and of an FCL filter
on the suction inlet connection of a vacuum generator of the M .. SSX range has allowed
creating these small pneumatic suction pumps. Their main features include reduced
overall dimensions compared to their technical performance.
Vacuum connection
For Ø 6 ext. hose
Item PA 3
Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85
Air consumption Nl/s 0.2 0.4 0.5 0.7 0.8
Intake air flow rate m3/h 2.0 2.5 3.0 3.4 3.6
A 88
B 110.5
R Ø G1/4”
Weight Kg 0.45
Item PA 7
Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85
Air consumption Nl/s 0.4 0.6 0.8 1.2 1.4
Intake air flow rate m3/h 3.0 4.0 5.4 5.8 6.2
A 89
B 111.5
R G3/8” 10
Weight Kg 0.46
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.03
SMALL PNEUMATIC SUCTION PUMPS PA 10, PA 14 and PA 18
3D drawings are available on vuototecnica.net
connection
Vacuum
Item PA 10
Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85
Air consumption Nl/s 0.5 0.9 1.2 1.6 1.9
Intake air flow rate m3/h 4.0 6.0 7.7 8.5 9.4
A 94
B 118.5
C 24.5
Weight Kg 0.59
Item PA 14
Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85
Air consumption Nl/s 0.9 1.3 1.7 2.1 2.5
Intake air flow rate m3/h 6.0 8.0 10.2 11.5 12.6
A 94
B 118.5
C 24.5
Weight Kg 0.60
Item PA 18
Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85
Air consumption Nl/s 1.2 1.7 2.3 2.9 3.6
Intake air flow rate m3/h 8.0 11.5 14.8 16.5 18.0
A 102
B 128.5
10 C 34.5
Weight Kg 0.62
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.04
PNEUMATIC SUCTION PUMPS PA
A newly designed range of ejectors has allowed creating this range of pneumatic suction pumps featuring an
excellent ratio between the amount of consumed air and sucked air, as well as the ability to adjust the level of
vacuum and flow rate according to the supply air pressure.
These pumps are powered with compressed air with a pressure ranging from 1 to 6 bar and they can produce a
connection
Vacuum
For Ø 12 ext. hose
Item PA40
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 14 30 46 65 82 90
Air consumption Nl/s 1.0 1.5 2.0 2.3 2.7 3.2
Intake air flow rate m3/h 15 23 30 36 39 42
Weight Kg 6.2
Item PA70
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 14 30 46 65 82 90
Air consumption Nl/s 2.0 3.0 4.1 4.9 5.7 6.6
Intake air flow rate m3/h 29 47 58 65 73 80
Weight Kg 6.2
Item PA100
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 11 28 45 65 82 90
Air consumption Nl/s 3.0 4.6 6.2 7.2 8.5 9.8
Intake air flow rate m3/h 28 57 75 88 98 108 10
Weight Kg 6.2
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.05
PNEUMATIC SUCTION PUMPS PA 140, PA 170 and PA 200
3D drawings are available on vuototecnica.net
connection
Vacuum
Compressed air connection
For Ø 15 ext. hose
Item PA 140
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 15 35 55 70 85 90
Air consumption Nl/s 4.1 6.2 8.3 9.6 11.4 13.0
Intake air flow rate m3/h 45 80 106 125 140 152
Weight Kg 7.2
Item PA 170
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 15 35 55 70 85 90
Air consumption Nl/s 5.1 7.7 10.3 12.1 14.2 16.3
Intake air flow rate m3/h 53 98 128 150 168 182
Weight Kg 7.2
Item PA 200
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 15 35 55 70 85 90
Air consumption Nl/s 6.0 9.1 12.2 14.2 16.9 19.4
10 Intake air flow rate m3/h 60 110 142 170 188 200
Weight Kg 7.2
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.06
PNEUMATIC SUCTION PUMPS PA 250 and PA 300
Item PA250
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 15 35 55 70 85 90
Air consumption Nl/s 7.5 11.2 15.0 17.3 20.7 24.0
Intake air flow rate m3/h 100 145 190 224 252 280
Weight Kg 8,1
Item PA300
Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 15 35 55 70 85 90
Air consumption Nl/s 9.0 13.5 18.1 20.4 24.8 29.0
Intake air flow rate m3/h 106 160 213 240 290 320 10
Weight Kg 8.1
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.07
SMALL PNEUMATIC BLOWING PUMPS PS
The assembly of a pressure adjuster equipped with pressure gauge and of an FCL filter
on the suction inlet connection of a vacuum generator of the M .. SSX range has allowed
creating these small pneumatic suction pumps. Their main features include reduced
overall dimensions compared to their technical performance.
3D drawings are available on vuototecnica.net
The pressure and flow rate can be adjusted according to the supply air pressure.
These pumps are powered with compressed air with a pressure ranging from 1 to 5 bar
and can produce a maximum pressure of 0.7 bar and a blowing flow rate between
2.7 and 31 m3/h, measured at a normal atmospheric pressure of 1013 mbar.
Based on the Venturi principle, they do not develop heat.
The filter equipped with microporous cartridge located on the air inlet connection can
keep the finest dust and impurities.
Thanks to their static operating principle, maintenance is reduced to only a simple
regular cleaning of the filter.
Compressed air
connection
Item PS 3
Supply pressure bar 1 2 3 4 5
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.2 0.4 0.5 0.7 0.8
Blown air flow rate m3/h 2.7 3.9 4.8 5.9 6.5
A 88
B 110.5
R Ø G1/4”
Weight Kg 0.44
Item PS 7
Supply pressure bar 1 2 3 4 5
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.4 0.6 0.8 1.2 1.4
Blown air flow rate m3/h 4.4 6.1 8.2 10.1 11.2
A 89
B 111.5
10 R G3/8”
Weight Kg 0.45
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.08
SMALL PNEUMATIC BLOWING PUMPS PS 10, PS 14 and PS 18
Item PS 10
Supply pressure bar 1 2 3 4 5
Maximum blowing pressure -KPa 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.5 0.9 1.2 1.6 1.9
Blown air flow rate m3/h 5.8 9.2 12.0 14.2 16.2
A 94
B 118.5
C 24.5
R G3/8”
Weight Kg 0.49
Item PS 14
Supply pressure bar 1 2 3 4 5
Maximum blowing pressure -KPa 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.9 1.3 1.7 2.1 2.5
Blown air flow rate m3/h 9.2 12.6 16.3 19.0 21.6
A 94
B 118.5
C 24.5
R G3/8”
Weight Kg 0.50
Item PS 18
Supply pressure bar 1 2 3 4 5
Maximum blowing pressure -KPa 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 1.2 1.7 2.3 2.9 3.6
Blown air flow rate m3/h 12.3 17.6 23.0 26.9 31.0
A 94
B 128.5
C 34.5
R G1/2” 10
Weight Kg 0.52
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.09
PNEUMATIC BLOWING PUMPS PS
A newly designed range of ejectors has allowed creating this range of pneumatic blowing
pumps featuring an excellent ratio between the amount of consumed air and generated air, as
well as the ability to adjust the pressure and flow rate according to the supply air pressure.
These pumps are powered with compressed air with a pressure ranging from 1 to 6 bar and
3D drawings are available on vuototecnica.net
have a blowing flow rate between 18 and 425 m3/h, measured at a normal atmospheric
pressure of 1013 mbar.
When designing these pumps, our attention was focused on noise. In fact, they are perfectly
soundproofed and there are no moving parts subject to wear and vibrations. All this results in
an extremely silent operation.
Moreover, as they are based on the Venturi principle, they do not develop heat.
They are equipped as standard with a filter/pressure reducer unit for the supply air and a filter
with microporous cartridge located on the air inlet connection which can keep the finest dust
and impurities.
The excellent filtration of the compressed air supply and intake air allows the intake of air free
from oil, water condensates or impurities from between the sheets of paper to be separated in
the working environment, with no pollution.
The use of light alloys for making these pumps has allowed a considerable reduction of their
weight thus allowing them to be directly installed onto the machine.
Thanks to their static operating principle, maintenance is reduced to a only a simple regular
cleaning of the filters.
connection
Blowing
Item PS 40
Supply pressure bar 1 2 3 4 5 6
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 1.0 1.5 2.0 2.3 2.7 3.2
Blown air flow rate m3/h 18 28 37 44 48 53
Weight Kg 6.3
Item PS 70
Supply pressure bar 1 2 3 4 5 6
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 2.0 3.0 4.1 4.9 5.7 6.6
Blown air flow rate m3/h 36 57 72 83 93 104
Weight Kg 6.3
Item PS 100
Supply pressure bar 1 2 3 4 5 6
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7 0.8
10 Air consumption Nl/s 3.0 4.6 6.2 7.2 8.5 9.8
Blown air flow rate m3/h 38 73 97 114 129 144
Weight Kg 6.3
Item PS 140
Supply pressure bar 1 2 3 4 5 6
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 4.1 6.2 8.3 9.6 11.4 13.0
Blown air flow rate m3/h 59 102 135 160 181 199
Weight Kg 7.3
Item PS 170
Supply pressure bar 1 2 3 4 5 6
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 5.1 7.7 10.3 12.1 14.2 16.3
Blown air flow rate m3/h 71 125 165 194 219 240
Weight Kg 7.3
Item PS 200
Supply pressure bar 1 2 3 4 5 6
Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 6.0 9.1 12.2 14.2 16.9 19.4 10
Blown air flow rate m3/h 81 142 185 221 249 270
Weight Kg 7.3
connection
Blowing
Item PS 250
Item PS 300
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.12
SMALL COMBINED PNEUMATIC SUCTION PUMPS PA AND BLOWING PUMPS PS
PA 3 ÷ 7 WITH PS 3 ÷ 7
All the small pneumatic suction and blowing pumps
previously described can be combined regardless of
their suction or blowing flow rate.
Given the enormous number of possible
Vacuum
connection
Blowing
connection
Item PA 3 Item PS 3
Supply pressure bar 1 2 3 4 5 Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85 Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.2 0.4 0.5 0.7 0.8 Air consumption Nl/s 0.2 0.4 0.5 0.7 0.8
Intake air flow rate m3/h 2.0 2.5 3.0 3.4 3.6 Blown air flow rate m3/h 2.7 3.9 4.8 5.9 6.5
A 88 A 88
B 110.5 B 110.5
R Ø G1/4” R Ø G1/4”
Weight Kg 0.45 Weight Kg 0.44
Item PA 7 Item PS 7
Supply pressure bar 1 2 3 4 5 Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85 Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.4 0.6 0.8 1.2 1.4 Air consumption Nl/s 0.4 0.6 0.8 1.2 1.4
Intake air flow rate m3/h 3.0 4.0 5.4 5.8 6.2 Blown air flow rate m3/h 4.4 6.1 8.2 10.1 11.2
A 88 A 88
B 110.5 B 110.5
R Ø G3/8” R Ø G3/8” 10
Weight Kg 0.46 Weight Kg 0.45
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.13
SMALL COMBINED PNEUMATIC SUCTION PUMPS PA AND BLOWING PUMPS PS
PA 10 ÷ 18 WITH PS 10 ÷ 18
3D drawings are available on vuototecnica.net
Blowing
connection
Item PA 10 Item PS 10
Supply pressure bar 1 2 3 4 5 Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85 Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.5 0.9 1.2 1.6 1.9 Air consumption Nl/s 0.5 0.9 1.2 1.6 1.9
Intake air flow rate m3/h 4.0 6.0 7.7 8.5 9.4 Blown air flow rate m3/h 5.8 9.2 12.0 14.2 16.2
A 94 A 94
B 118.5 B 118.5
C 24.5 C 24.5
R Ø G3/8”
Weight Kg 0.59 Weight Kg 0.49
Item PA 14 Item PS 14
Supply pressure bar 1 2 3 4 5 Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85 Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 0.9 1.3 1.7 2.1 2.5 Air consumption Nl/s 0.9 1.3 1.7 2.1 2.5
Intake air flow rate m3/h 6.0 8.0 10.2 11.5 12.6 Blown air flow rate m3/h 9.2 12.6 16.3 19.0 21.6
A 94 A 94
B 118.5 B 118.5
C 24.5 C 24.5
R Ø G3/8”
Weight Kg 0.60 Weight Kg 0.50
Item PA 18 Item PS 18
Supply pressure bar 1 2 3 4 5 Supply pressure bar 1 2 3 4 5
Maximum level of vacuum -KPa 20 42 62 80 85 Maximum blowing pressure bar 0.1 0.2 0.3 0.5 0.7
Air consumption Nl/s 1.2 1.7 2.3 2.9 3.6 Air consumption Nl/s 1.2 1.7 2.3 2.9 3.6
Intake air flow rate m3/h 8.0 11.5 14.8 16.5 18.0 Blown air flow rate m3/h 12.3 17.6 23.0 26.9 31.0
A 94 A 94
B 136.5 B 128.5
C 34.5 C 34.5
10 R Ø G1/2”
Weight Kg 0.62 Weight Kg 0.52
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.14
COMBINED PNEUMATIC SUCTION PUMPS PA AND BLOWING PUMPS PS
PA 40 ÷ 100 WITH PS 40 ÷ 100
All the pneumatic suction and blowing pumps previously described
can be combined regardless of their suction or blowing flow rate.
Given the enormous number of possible combinations, for space
reasons, this catalogue only describes combinations of pumps with
Blowing
connection
Compressed air
connection
Compressed air
Vacuum
connection
connection
For Ø 12 ext. hose
For Ø 12 ext. hose
Item PA 40 Item PS 40
Supply pressure bar 1 2 3 4 5 6 Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 14 30 46 65 82 90 Maximum blowing pressure -KPa 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 1.0 1.5 2.0 2.3 2.7 3.2 Air consumption Nl/s 1.0 1.5 2.0 2.3 2.7 3.2
Intake air flow rate m3/h 15 23 30 36 39 42 Blown air flow rate m3/h 18 28 37 44 48 53
Weight Kg 6.2 Weight Kg 6.3
Item PA 70 Item PS 70
Supply pressure bar 1 2 3 4 5 6 Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 14 30 46 65 82 90 Maximum blowing pressure -KPa 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 2.0 3.0 4.1 4.9 5.7 6.6 Air consumption Nl/s 2.0 3.0 4.1 4.9 5.7 6.6
Intake air flow rate m3/h 29 47 58 65 73 80 Blown air flow rate m3/h 36 57 72 83 93 104
Weight Kg 6.2 Weight Kg 6.3
Item PA 100 Item PS 100
Supply pressure bar 1 2 3 4 5 6 Supply pressure bar 1 2 3 4 5 6
Maximum level of vacuum -KPa 14 30 46 65 82 90 Maximum blowing pressure -KPa 0.1 0.2 0.3 0.5 0.7 0.8
Air consumption Nl/s 3.0 4.6 6.2 7.2 8.5 9.8 Air consumption Nl/s 3.0 4.6 6.2 7.2 8.5 9.8
Intake air flow rate m3/h 28 57 75 88 98 108 Blown air flow rate m3/h 38 73 97 114 129 144
10
Weight Kg 6.2 Weight Kg 6.3
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.15
COMBINED PNEUMATIC SUCTION PUMPS PA AND BLOWING PUMPS PS
PA 140 ÷ 200 WITH PS 140 ÷ 200
3D drawings are available on vuototecnica.net
Blowing
connection
connection
Vacuum
Compressed air
Compressed air
connection
connection
For Ø 15 ext. hose
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.16
COMBINED PNEUMATIC SUCTION PUMPS PA AND BLOWING PUMPS PS
PA 250 ÷ 300 WITH PS 250 ÷ 300
connection
Vacuum
Compressed air
Compressed air
connection
connection
For Ø 15 ext. hose
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.17
SUCTION AND BLOWING SYSTEM AS
With the suction and blowing system AS, we have tried to provide the printing industry with an answer to most of their requirements regarding
the management of paper during the printing process, or rather:
- The concentration of all the necessary pumps and commands on one single piece.
- An increased printing quality thanks to individually controlled pumps.
3D drawings are available on vuototecnica.net
- An increase of productivity resulting from the configuration and use of individual pumps.
- Reduced machine idle state due to the pneumatic pumps based on the Venturi principle.
- An improvement of the work environment thanks to the noise reduction, absence of heat and the emission of air free of oil vapours, water
condensation and impurities between the sheets of paper to be separated and in the work environment.
- Energy saving due to a low compressed air consumption compared to the amount of
sucked (or generated) air.
- Maintenance reduced to a regular cleaning of the filters.
The suction and blowing system AS is composed of a metal, easy-to-place cabinet, inside of
which the combined pneumatic pumps PA and PS are located with the supply compressed air
interception and adjustment valves.
The suction and blowing capacities of the pumps are determined according to the client’s
requirements or to technical specifications of the machine manufacturer.
The blowing and suction connectors are located on the sides of the cabinet for the connection to
the application, as well as the filters equipped with micro-porous cartridge against fine dust.
The following are installed on the control panel:
- The pneumatic main switch for supply compressed air interception with a pressure gauge
for a direct reading of the line pressure.
- The pneumatic switches for supply compressed air interception of every single pump.
- The pressure reducers with relative pressure gauges for adjusting the compressed air of
every single pump. The vacuum (or pressure) level as well as the pump flow rate can be
adjusted according to the supply air pressure.
- Vacuum gauges and pressure gauges for a direct reading of the vacuum and pressure at
the application.
- Vacuum gauges for controlling the clogging level of the PS pump filters.
All our pneumatic suction and blowing pumps can be combined regardless of their suction
and blowing flow rate and can be installed inside the system cabinet. Given the enormous
number of possible combinations, this catalogue only describes combinations of pumps
with the same size.
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
10.18
PNEUMATIC SUCTION AND BLOWING PUMP HOLDING SUPPORTS
Rubber feet
A B C D E F G H I L M N O P Q Weight
Item
Ø Ø Kg
GR DIV 03 100 39.5 3.75 64 12 11.5 74.5 13.5 41 43 84 47.5 79 4.5 45° 0.1
Rubber feet
Rubber feet
10
A B C D E F G H I L M N O P Q Weight
Item
Ø Ø Kg
GR DIV 01 140 120 10 270 15 30 80 10 264 81 355 170 250 8.5 45° 2.1
GR DIV 02 284 132 10 270 15 30 224 10 264 81 355 170 250 8.5 45° 4.2
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
10.19
PNEUMATIC SUCTION AND BLOWING PUMP SUCTION FILTERS
To allow the pneumatic suction and blowing pumps to work even in very dusty
environments, it is necessary to use these filters that, installed on the suction inlet
connection, can keep the finest dust and impurities and affecting the flow rate in a
negligible manner.
3D drawings are available on vuototecnica.net
The filtering cartridges, in fact, are made with a special treated paper with a porosity
level of 5 - 7 micron, and pleated to increase the filtering surface.
FCL filters are composed of a transparent Plexiglass cylindrical body inside of which is
located the filtering cartridge locked by two anodised aluminium flanges that are kept in
place by Seeger rings, inside of which the threaded connectors and the seals are housed.
The filters can be inspected by simply removing one of the two flanges.
The container of the filtering element FP is made with plastic and it is screwed onto the
blue plastic lid; a gasket located between the two elements ensures a perfect seal.
The container of the filtering element FC, as well as its lid, are made with sheet steel
and varnished with a special oxidation-resistant treatment. A seal between the lid and
the container ensures a perfect vacuum seal, while the release clamps on the container
allow a quick opening of the lid to check or replace the filtering cartridge.
Item FC 38
Item FP 30 / 4 / SP Item FC 55
10
d A B C D Max capac. For pumps Weight Spare cartridge
Item
Ø Ø m3/h item Kg item
FP 30/4/SP G1” 145 169 24 130 100 PA - PS 40 ÷ 100 1.00 SP/4
FC 38 G1” 1/2 143 101 45 120 200 PA - PS 140 ÷ 200 0.95 00 FC 15
FC 55 G2” 143 170 79 120 300 PA - PS 250 ÷ 300 1.29 00 FC 33
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
10.20
PNEUMATIC PUMP SPARE PARTS
10
10.21
PNEUMATIC PUMP SPARE PARTS
10.22
VACUUM CYLINDERS
duration. Sp.2
Sp.3
stroke
Item 25 05 10 25 10 10 25 15 10
Stroke mm 17 25 30
Thrust force at -KPa 80 Kg 2.0 4.3 12.0
Lifting force at -KPa 80 Kg 0.45 1.0 2.5
Minimum cycle time sec 0.3 0.4 0.6
Minimum level of vacuum -KPa 60 60 60
Minimum necessary flow rate Nl/1’ 15 30 90
Operating temperature °C 5 ÷ 80 5 ÷ 80 5 ÷ 80
Weight g 55 145 515
A Ø 24 35 59
B Ø M6 G1/8” M 10
C Ø M5 G1/8” G1/4”
D Ø M 16 x 1.5 M 22 x 1.5 M 40 x 1.5
E Vacuum connection by tube Ø int. 4 4 4
F 39.5 56 66
G 12 16 17
H 4 6 9 10
I 55.5 78 92
wr. 1 19 27 50
wr. 2 24 32 55
wr. 3 8 12 17
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = = Adapters for GAS - NPT threading available on page 1.130
25.4 453.6 0.4536
10.23
DISC CUPS
Apart from some standard rubber discs, these items are generally produced upon
specific request by the client and for a minimum amount to be specified in the offer
phase.
They can be die-cut from sheets or moulded in nitrile rubber, in natural para rubber,
3D drawings are available on vuototecnica.net
EXAMPLE OF APPLICATION
D d S
Item
Ø Ø
01 17 31 N 17 3.5 0.8
01 30 41 NG 30 4.0 1.5
10 01 30 91 N 30 9.0 1.5
01 57 81 S 57 8.5 1.3
N = natural para rubber; NG= yellow rubber; S = silicone
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
10.24
SPECIAL PRODUCTS
11
11
3D drawings are available on vuototecnica.net
DEGASIFIERS
The function of degasifiers is to suck the air bubbles that remain in the synthetic resin or
composite material mixes and in silicone or similar compounds during their preparation.
The presence of bubbles, in fact causes a drastic reduction of their technical features
and negatively affects their appearance.
Vacuum
pump
100-litre
autoclave
Liquid
discharge cap
Vacuum
pump
100-litre
autoclave
50-litre
autoclave
Liquid Liquid
discharge cap discharge cap
This system has been designed for allowing resin vacuum infusion moulding and
composite fibre vacuum forming.
The system is composed of:
- A welded sheet steel autoclave featuring a perfect vacuum seal, equipped with a
3D drawings are available on vuototecnica.net
2-way vacuum
interception valve
100-litre
autoclave
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
11.02
ELECTRICAL EQUIPMENT FOR VACUUM TESTS
These devices have been created for testing the weldings and,
therefore, the sealing of cellophane or PVC wrappings for food
products.
In fact, the wrapping placed inside a bell jar tends to inflate because
Casing
Vacuum pump
mm g Kg
Transformation ratio: N (newton) = Kg x 9.81 (force of gravity) inch = ; pounds = =
25.4 453.6 0.4536
11.03
EQUIPMENT FOR VACUUM TESTS
The function of these devices is to test the welding sealing in flow-pack, cellophane or food product
wrappings.
They are composed of:
- A transparent Plexiglass cylindrical container into which the water is poured and the vacuum is created.
3D drawings are available on vuototecnica.net
- A mobile transparent Plexiglass lid with, on its lower part, a perforated disc fixed via a pin which is for
keeping the flow-pack wrapping submerged in the water, in the container and on its upper part, the
instruments for managing and controlling the vacuum.
- A multiple ejector multi-stage vacuum generator.
- A check valve located on the generator suction inlet to prevent the air from returning into the container
when the generator is not in operation.
- A sleeve valve for compressed air interception.
- A supply compressed air reducer equipped with pressure gauge.
- A 2-way manual valve for restoring the atmospheric pressure inside the container.
The wrapping submerged in the water in the container tends to inflate because of the pressure differential
produced between the air at atmospheric pressure on its inside and the vacuum created in the container.
The higher the level of vacuum reached in the bell jar and the greater the thrust that the air contained in
the wrapping will exert on the walls and, therefore, on the weldings.
Any air leak from the wrapping due to a defecting welding is proved by bubbles that indicate the exact
point of the welding that’s leaking.
The level of vacuum that can be reached inside the bell jar depends on the pump installed.
The test values are adjustable and can be automatically repeated.
Available in other versions upon request.
Technical features
Operating pressure: from 0.5 to 1000 absolute mbar
Fluid temperature: from -5 to +50°C
Level of filtration: 60 μ
Handwheel Pressure reducer
Vacuum Pressure
gauge gauge
Plexiglass
container
Packaged
product
Water
Drain hole
Air inlet valve
Vacuum
generator
These suction units with syphon filter allow sucking fluids saturated with condensation
or mixed with water and liquids. They share all the best technical features of syphon
filters and vacuum generators. In fact, they keep liquids and solid impurities, while the
vacuum generator can suck fluids saturated with vapours or liquid condensation without
Pressure
reducer
Filter
cartridge
Cock for liquid
discharge
These suction units with syphon filters share the same features and functions as the
previous ones; their distinctive features are their size and the type of generator installed.
Their functions are also the same.
These devices are composed of:
3D drawings are available on vuototecnica.net
Vacuum gauge
09 05 10
Vacuum interception
Filter
cartridge
valve
For Ø d
ext. hose
Magnetic level switch
Coaxial servo-piloted
ball supply valve
interception valve
Compressed air
These units have the same functions as the previous ones, but they differ in their automation and
composition. In fact, these devices are composed of:
- A standard syphon filter described in Chapter 5.
- Two compressed air-operated multi-stage vacuum generators with a built-in energy-saving system ES.
Filter
cartridge
valve
For Ø d
Magnetic level switch
interception valve
ext. hose
Compressed air
These pump sets are for sucking liquids and collect them inside their tanks. The
maximum level difference that can be exceeded is approximately 9 metres.
They are composed of:
- A welded sheet steel large-capacity tank
3D drawings are available on vuototecnica.net
Vacuum gauge 09 05 10
Valvola principale
di esclusione vuoto
Vacuum reducer
atmospheric pressure
solenoid valve
switch Item 12 40 10
Digital vacuum
Switchgear
Liquid discharge
valve
Technical features
VTBOX01 weight: 26 kg
650
310
390
VTBOX01
11
11.09
SAMPLES AND EQUIPMENT FOR DEMONSTRATION USE
TEST BENCH AND TESTS FOR THE SELECTION OF VACUUM CUPS- BT01
Technical features
Electrical power: Single-phase V230 ± 10% 50/60 Hz
Electric power: 1.5 kw
Compressed air consumption: 390 L/min 2bar
BT01 weight: 115 kg
Flight case 01 weight: 200 kg
Total weight: 315 kg
800
1300
1600 BT01
600
1000
11
11.10
SAMPLES AND EQUIPMENT FOR DEMONSTRATION USE
Technical features
Electrical power: Single-phase V230 ± 10% 50/60 Hz
Electric power: 0.5 kw
Compressed air consumption: 390 L/min 2bar
CONVY01 weight: 90 kg
Flight case 01 weight: 200 kg
Total weight: 290 kg
800
1300
CONVY01
1600
600
1000 11
11.11
SAMPLES AND EQUIPMENT FOR DEMONSTRATION USE
Technical features
Electrical power: Single-phase V230 ± 10% 50/60 Hz
Electric power: 3.5 kw
VACBOT weight: 475 kg
Flight case 02 weight: 275 kg
Total weight: 750 kg
1600
1500
VACBOT
1800
1100
1300
11
11.12
INDEX OF PRODUCTS IN ORDER OF CODE
00 02 36 Vacuum cup support pg. 1.18 - 1.19
00 02 37 Vacuum cup support pg. 1.20
00 06 13 Vacuum cup support pg. 1.18 - 1.19
00 06 14 Vacuum cup support pg. 1.20
00 07 311 Low abs. solenoid pilot valve V 12 DC, bistable pg. 4.60
00 07 366 Low abs. solenoid pilot valve V 24 DC, bistable pg. 4.60
00 07 372 Solenoid valve sealing kit 07 08 11 pg. 4.41
00 07 379 Solenoid valve sealing kit 07 08 13 pg. 4.62
00 07 380 Valve sealing kit 07 08 31 pg. 4.41
00 07 381 Solenoid valve sealing kit 07 08 51 pg. 4.41
00 07 382 Solenoid valve sealing kit 07 09 11 pg. 4.41
00 07 383 Solenoid valve sealing kit 07 09 13 pg. 4.62
00 07 384 Valve sealing kit 07 09 31 pg. 4.41
00 07 385 Solenoid valve sealing kit 07 09 51 pg. 4.41
00 07 411 NC solenoid pilot valve with interface valve pg. 4.61
00 07 412 NC solenoid pilot valve with interface valve pg. 4.61
00 08 01 Vacuum cup support pg. 1.01 - 1.106
00 08 02 Vacuum cup support pg. 1.01 - 1.106
00 08 03 Vacuum cup support pg. 1.02 - 1.68 - 1.69 - 1.71 - 1.75
1.79 - 1.87 - 1.89 - 1.106
00 08 04 Vacuum cup support pg. 1.03 - 1.68 - 1.70 - 1.76
1.79 - 1.87 - 1.90 - 1.106
00 08 05 Vacuum cup support pg. 1.02 - 1.70 - 1.102 - 1.103
1.107
00 08 06 Vacuum cup support pg. 1.71 - 1.86 - 1.87 - 1.89
1.107
00 08 07 Vacuum cup support pg. 1.94 - 1.95 - 1.107
00 08 08 Vacuum cup support pg. 1.04 - 1.95 - 1.107
00 08 09 Vacuum cup support pg. 1.72 - 1.83 - 1.105 - 1.107
00 08 10 Vacuum cup support pg. 1.76 - 1.77 - 1.108
00 08 14 Vacuum cup support pg. 1.03 - 1.102 - 1.103 - 1.108
00 08 15 Vacuum cup support pg. 1.80 - 1.97 - 1.108
00 08 18 Vacuum cup support pg. 1.52 - 1.71 - 1.97 - 1.98
1.99 - 1.101 - 1.108
00 08 19 Vacuum cup support pg. 1.81 - 1.109
00 08 20 Vacuum cup support pg. 1.02 - 1.109
00 08 21 Vacuum cup support pg. 1.03 - 1.109
00 08 22 Vacuum cup support pg. 1.05 - 1.109
00 08 24 Vacuum cup support pg. 1.84 - 1.85 - 1.110
00 08 26 Vacuum cup support pg. 1.104 - 1.110
00 08 28 Vacuum cup support pg. 1.06 - 1.110
00 08 29 Vacuum cup support pg. 1.07 - 1.110
00 08 31 Vacuum cup support pg. 1.35 - 1.111
00 08 32 Vacuum cup support pg. 1.18 - 1.19 - 1.24 - 1.111
00 08 33 Vacuum cup support pg. 1.20 - 1.24 - 1.111
00 08 34 Vacuum cup support pg. 1.35 - 1.39 - 1.112
00 08 35 Vacuum cup support pg. 1.21 - 1.112
00 08 37 Vacuum cup support pg. 1.22 - 1.26
00 08 44 Vacuum cup support pg. 1.05 - 1.112
00 08 46 Vacuum cup support pg. 1.07 - 1.113
00 08 50 Vacuum cup support pg. 1.98 - 1.99 - 1.100 - 1.101
1.113
00 08 54 FF adapter for joint couplings pg. 1.131
00 08 58 Vacuum cup support pg. 1.25 - 1.113
00 08 59 Vacuum cup support pg. 1.35 - 1.39 - 1.113
00 08 60 Vacuum cup support pg. 1.04 - 1.73 - 1.77 - 1.79
1.95 - 1.114
00 08 61 Vacuum cup support pg. 1.94 - 1.96 - 1.114
00 08 62 Vacuum cup support pg. 1.94 - 1.96 - 1.114
00 08 64 Vacuum cup support pg. 1.69 - 1.72 - 1.88 - 1.90
1.92 - 1.93 - 1.114
00 08 65 Vacuum cup support pg. 1.88 - 1.91 - 1.92 - 1.93
1.114
00 08 66 Vacuum cup support pg. 1.89 - 1.91 - 1.92 - 1.94
1.115
00 KIT VTL 20F Sealing kit for pump VTL 20/F pg. 7.45
00 KIT VTL 25FG Sealing kit for pump VTL 25/FG pg. 7.45
00 KIT VTL 30FG Sealing kit for pump VTL 30/FG pg. 7.45
00 KIT VTL 35FG Sealing kit for pump VTL 35/FG pg. 7.45
00 KIT VTL 40G1 Sealing kit for pump VTL 40/G1 pg. 7.45
00 KIT VTL 50G1 Sealing kit for pump VTL 50/G1 pg. 7.45
00 KIT VTL 65G1 Sealing kit for pump VTL 65/G1 pg. 7.45
00 KIT VTL 75G1 Sealing kit for pump VTL 75/G1 pg. 7.45
00 KIT VTL 90G1 Sealing kit for pump VTL 90/G1 pg. 7.45
00 KIT VTL 105G1 Sealing kit for pump VTL 105/G1 pg. 7.45
00 KIT VTS 02 Sealing kit for pump VTS 2 pg. 7.61
00 KIT VTS 04 Sealing kit for pump VTS 4 pg. 7.61
00 KIT VTS 06 Sealing kit for pump VTS 6 pg. 7.61
00 KIT VTS 10 Sealing kit for pump VTS 10 pg. 7.61
00 KIT VTS 10F Sealing kit for pump VTS 10/F pg. 7.61
00 KIT VTS 10FG Sealing kit for pump VTS 10/FG pg. 7.61
00 KIT VTS 15F Sealing kit for pump VTS 15/F pg. 7.61
00 KIT VTS 15FG Sealing kit for pump VTS 15/FG pg. 7.61
00 KIT VTS 20F Sealing kit for pump VTS 20/F pg. 7.61
00 KIT VTS 20FG Sealing kit for pump VTS 20/FG pg. 7.61
00 KIT VTS 25F Sealing kit for pump VTS 25/F pg. 7.61
00 KIT VTS 25FG Sealing kit for pump VTS 25/FG pg. 7.61
00 KIT VTS 30FG Sealing kit for pump VTS 30/FG pg. 7.61
00 KIT VTS 35FG Sealing kit for pump VTS 35/FG pg. 7.61
00 LP VTL 40 Oil filter for pumps VTLP pg. 7.47
00 LP VTL 99 Oil level switch pg. 7.47
00 RVP 15 04 Fibre vane for pump RVP 15 pg. 7.44
00 RVP 15 05 Deoiling cartridge for RVP 15 pg. 7.47
00 RVP 15 06 Sealing kit for pump RVP 15 pg. 7.45
00 RVP 21 04 Fibre vane for pump RVP 21 pg. 7.44
00 RVP 21 05 Deoiling cartridge for RVP 21 pg. 7.47
00 RVP 21 06 Sealing kit for pump RVP 21 pg. 7.45
00 RVP 40 04 Fibre vane for pump RVP 40 pg. 7.44
00 RVP 40 05 Deoiling cartridge for RVP 40 pg. 7.47
00 RVP 40 06 Sealing kit for pump RVP 40 pg. 7.45
00 RVP 40 07 Oil filter for pump RVP 40 pg. 7.47
00 RVP 60 04 Fibre vane for pump RVP 60 pg. 7.44
00 RVP 60 05 Deoiling cartridge for RVP 60 pg. 7.47
00 RVP 60 06 Sealing kit for pump RVP 60 pg. 7.45
00 RVP 60 07 Oil filter for pump RVP 60 pg. 7.47
00 RVP 100 04 Fibre vane for pump RVP 100 pg. 7.44
00 RVP 100 05 Deoiling cartridge for RVP 100 pg. 7.47
00 RVP 100 06 Sealing kit for pump RVP 100 pg. 7.45
00 RVP 100 07 Oil filter for pump RVP 100 pg. 7.47
00 RVP 160 04 Fibre vane for pump RVP 160 pg. 7.44
00 RVP 160 05 Deoiling cartridge for RVP 160 pg. 7.47
00 RVP 160 06 Sealing kit for pump RVP 160 pg. 7.45
00 RVP 160 07 Oil filter for pump RVP 160 pg. 7.47
00 RVP 200 04 Fibre vane for pump RVP 200 pg. 7.44
00 RVP 200 05 Deoiling cartridge for RVP 200 pg. 7.47
00 RVP 200 06 Sealing kit for pump RVP 200 pg. 7.45
00 RVP 200 07 Oil filter for pump RVP 200 pg. 7.47
00 RVP 250 04 Fibre vane for pump RVP 250 pg. 7.44
00 RVP 250 05 Deoiling cartridge for RVP 250 pg. 7.47
00 RVP 250 06 Sealing kit for pump RVP 250 pg. 7.45
00 RVP 250 07 Oil filter for pump RVP 250 pg. 7.47
00 RVP 300 04 Fibre vane for pump RVP 300 pg. 7.44
00 RVP 300 05 Deoiling cartridge for RVP 300 pg. 7.47
00 RVP 300 06 Sealing kit for pump RVP 300 pg. 7.45
00 RVP 300 07 Oil filter for pump RVP 300 pg. 7.47
00 SO 05 Stainless steel disc filter pg. 9.34
06 110 116 Special adjustable anti-rotation vacuum cup holders pg. 2.148
06 127 42 Special articulated vacuum cup holders pg. 2.143
06 150 10 Special vacuum cup holders pg. 2.112
06 150 12 Special articulated vacuum cup holders pg. 2.135
06 150 13 Special vacuum cup holders with double springing pg. 2.153
06 150 14 Spec. articulated vacuum cup holders with double spring. pg. 2.160
06 150 15 Special vacuum cup holders pg. 2.114
06 150 17 Special articulated vacuum cup holders pg. 2.136
06 150 18 Special vacuum cup holders with double springing pg. 2.154
06 150 19 Spec. articulated vacuum cup holders with double spring. pg. 2.161
06 150 20 Special vacuum cup holders with plunger valve pg. 2.129
06 150 22 Special vacuum cup holders with plunger valve pg. 2.130
06 150 30 Special vacuum cup holders pg. 2.119
06 150 32 Special articulated vacuum cup holders pg. 2.141
06 150 36 Special vacuum cup holders pg. 2.113
06 150 42 Special articulated vacuum cup holders pg. 2.144
06 150 74 Special vacuum cup holders pg. 2.121
06 180 30 Special vacuum cup holders pg. 2.119
06 200 10 Special vacuum cup holders pg. 2.114
06 200 12 Special articulated vacuum cup holders pg. 2.136
06 200 13 Special vacuum cup holders with double springing pg. 2.154
06 200 14 Spec. articulated vacuum cup holders with double spring. pg. 2.161
06 200 20 Special vacuum cup holders with plunger valve pg. 2.130
06 220 10 A Special vacuum cup holders pg. 2.116
06 220 10 NF Special vacuum cup holders pg. 2.115
06 220 10 OF Special vacuum cup holders pg. 2.115
06 220 12 A Special articulated vacuum cup holders pg. 2.138
06 220 12 NF Special articulated vacuum cup holders pg. 2.137
06 220 12 OF Special articulated vacuum cup holders pg. 2.137
06 220 13 A Special vacuum cup holders with double springing pg. 2.156
06 220 13 NF Special vacuum cup holders with double springing pg. 2.155
06 220 13 OF Special vacuum cup holders with double springing pg. 2.155
06 220 14 A Spec. articulated vacuum cup holders with double spring. pg. 2.163
06 220 14 NF Spec. articulated vacuum cup holders with double spring. pg. 2.162
06 220 14 OF Spec. articulated vacuum cup holders with double spring. pg. 2.162
06 250 10 Special vacuum cup holders pg. 2.114
06 250 12 Special articulated vacuum cup holders pg. 2.136
06 250 13 Special vacuum cup holders with double springing pg. 2.154
06 250 14 Spec. articulated vacuum cup holders with double spring. pg. 2.161
06 250 20 Special vacuum cup holders with plunger valve pg. 2.130
06 250 30 Special vacuum cup holders pg. 2.122
06 300 10 Special vacuum cup holders pg. 2.117
06 300 12 Special articulated vacuum cup holders pg. 2.139
06 300 13 Special vacuum cup holders with double springing pg. 2.157
06 300 14 Spec. articulated vacuum cup holders with double spring. pg. 2.164
06 300 20 Special vacuum cup holders with plunger valve pg. 2.131
06 350 10 Special vacuum cup holders pg. 2.117
06 350 12 Special articulated vacuum cup holders pg. 2.139
06 350 13 Special vacuum cup holders with double springing pg. 2.157
06 350 14 Spec. articulated vacuum cup holders with double spring. pg. 2.164
06 350 20 Special vacuum cup holders with plunger valve pg. 2.131
07 01 11 1/4” three-way servo-operated solenoid valve pg. 4.22
07 01 13 1/4” 3-way low-absorb. servo-operated SV pg. 4.42
07 01 16 1/4” three-way solenoid pilot valve pg. 4.17
07 01 20 1/4” two-way solenoid pilot valve pg. 4.19
07 01 31 1/4” three-way servo-operated valve pg. 4.12
07 01 51 1/4” 3-way servo-operated SV with two coils pg. 4.28
07 01 53 1/4” 3-way bistable servo-operated SV pg. 4.48
07 01 71 Coaxial shutter servo-controlled supply valve pg. 8.99
07 02 11 3/8” three-way servo-operated solenoid valve pg. 4.22
07 02 13 3/8” 3-way low-absorb. servo-operated SV pg. 4.42
DSV 2000V RVP 300 2000 L vert. safety pump set pg. 7.80
DV 150V VTL 25/FG 150 L vertical pump set pg. 7.75
DV 150V VTL 30/FG 150 L vertical pump set pg. 7.75
DV 150V VTL 35/FG 150 L vertical pump set pg. 7.75
DV 150V RVP 40 150 L vertical pump set pg. 7.75
DV 150V VTL 50/G1 150 L vertical pump set pg. 7.75
DV 150V RVP 60 150 L vertical pump set pg. 7.75
DV 150V VTL 75/G1 150 L vertical pump set pg. 7.75
DV 300V RVP 40 300 L vertical pump set pg. 7.75
DV 300V VTL 50/G1 300 L vertical pump set pg. 7.75
DV 300V RVP 60 300 L vertical pump set pg. 7.75
DV 300V VTL 75/G1 300 L vertical pump set pg. 7.75
DV 300V RVP 100 300 L vertical pump set pg. 7.75
DV 300V VTL 105/G1 300 L vertical pump set pg. 7.75
DV 300V RVP 160 300 L vertical pump set pg. 7.75
DV 300V RVP 200 300 L vertical pump set pg. 7.75
DV 500V RVP 160 500 L vertical pump set pg. 7.76
DV 500V RVP 200 500 L vertical pump set pg. 7.76
DV 500V RVP 250 500 L vertical pump set pg. 7.76
DV 500V RVP 300 500 L vertical pump set pg. 7.76
DV 1000V RVP 200 1000 L vertical pump set pg. 7.76
DV 1000V RVP 250 1000 L vertical pump set pg. 7.76
DV 1000V RVP 300 1000 L vertical pump set pg. 7.76
DVL 150 Liquid-sucking pump set pg. 11.08
DVL 300 Liquid-sucking pump set pg. 11.08
DVL 500 Liquid-sucking pump set pg. 11.08
DVL 1000 Liquid-sucking pump set pg. 11.08
EGN 40 NC 1”1/2 two-way solenoid valve pg. 4.21-1
EGN 40 NO 1”1/2 two-way solenoid valve pg. 4.21-2
EGN 52 NC 2” two-way solenoid valve pg. 4.21-3
EGN 52 NO 2” two-way solenoid valve pg. 4.21-4
ES 01 Kit for energy saving device pg. 8.100
ES 02 Kit for energy saving device pg. 8.100
ES 05 Kit for energy saving device pg. 8.110
ES 06 Kit for energy saving device pg. 8.94
FB 1 Silencer filter pg. 8.28
FB 5 1/4” suction filter pg. 5.03 - 7.46 - 7.61
FB 10 3/8” suction filter pg. 5.04 - 7.46 - 7.61
FB 20 1/2” suction filter pg. 5.05 - 7.46 - 7.61
FB 20 A 1/2” suction filter pg. 5.06
FB 28 3/4” suction filter pg. 5.07 - 7.46 - 7.61
FB 30 1” suction filter pg. 5.08 - 7.46
FB 40 1”1/4 suction filter pg. 5.09 - 7.46
FB 50 1”1/2 suction filter pg. 5.09 - 7.46
FB 60 2” suction filter pg. 5.10
FC 10 3/8” suction filter pg. 5.12 - 7.46 - 7.61
FC 20 1/2” suction filter pg. 5.12 - 7.46 - 7.61
FC 25 3/4” suction filter pg. 5.12 - 7.46 - 7.61
FC 30 1” suction filter pg. 5.13 - 7.46
FC 35 1”1/4 suction filter pg. 5.13 - 7.46
FC 38 1”1/2 suction filter pg. 5.13 - 10.20
FC 40 1”1/4 suction filter pg. 5.14 - 7.46
FC 50 1”1/2 suction filter pg. 5.14 - 7.46
FC 55 2” suction filter pg. 5.13 - 10.20
FC 60 2” suction filter pg. 5.15 - 7.46
FC 80 3” suction filter pg. 5.15
FC 100 4” suction filter pg. 5.15
FCH 01 Fixing supp. for generators PVP 2 and 3 pg. 8.38
FCH 01 INOX Fixing supp. for generators PVP 2 and 3 pg. 8.38
FCH 02 Fixing supp. for generators 15 01/07 10 pg. 8.38
FCH 02 INOX Fixing supp. for generators 15 01/07 10 pg. 8.38