Machine: MLK004100
Client: “FİN-PLAST İNTERNATİONAL” LLC Drawing nº: 223295
TECHNICAL CHARACTERISTICS
Electrical supply
Characteristics Technical information
Maximum power (KW) 102
Electricity supply (V) 3 x 400V + PE
Frequency (HZ) 50
Maximum current absorbed (A) 154
Tensión of controls (V) 220/24
Input transformer (KVA) NO
The user’s main power line must be protected from any current overloads by means of safety switches
(magnetothermic switches) and differentials.
The differential relay on the automatic switch must be insulated against harmonic electrical current, pursuant
to in force regulation.
The differential relay must be adjusted current and timer. This differential relay must be adjusted to 300 mA.
We suggest using Schneider Electric VIGIREX, ref: RH99M relay, or equivalent.
The earthing system of the installation should not exceed 2 ohms.
We recommend to use a type TT ground connection System to avoid the risk of incidents in electronic
devices.
Internet connection
Ethernet connection will be required for machine start-up.
Ethernet IEEE 802.3
In case proxy/router is used, to enable remote connection, following ports, must remain open: 21, 25, 80, 110,
443, 11438
Downloading files will be required from server to enable remote connection.
File download must be permited from proxy.
Water supply
Characteristics Technical information
Minimum pressure (bar.) 1
Maximum pressure (bar.) 3
Hardness (CaCO3)(mg/l) 2,5 - 4
PH 7÷8,5
Inner filtering at (μ) 20
Temperature (ºC) 16 - 20
Maximum loss of main water inlet / outlet pressure (bar) 0,4 - 0,7
Connection diameter, inlet / outlet ("G) 3/4
Pneumatic supply
Characteristics Datos técnicos
Pneumatic supply Non-lubricated dry air
Pneumatic pressure (bar.) 6-8
Air consumption (l/min.) 434
Connection diameter ("G) 1/2
Coating unit vapors exhaust
Residual vapors exhaust flow (Nm3/h) 1400
All residual vapors exhaust have to be treated with pursuant to in force laws.
See drawing "DIAGRAM MACHINE CONNECTIONS"
Treater ozone exhaust
Treater ozone exhaust flow for unit (Nm3/h) 1250
All residual vapors have to be treated with pursuant to in force laws.
The diameter exhaust ozone of the piping has to be minimum Ø200mm, this piping must be with smooth
Surface and resistant to ozone.
The piping on the pressure side can be not longer than 8m and with maximum two 90º angles integrated in
the piping.
In case one of this points cannot be keep it is necessary to discuss the changes with an expert for exhaust
technique and air flow.
See drawing "DIAGRAM MACHINE CONNECTIONS"
Drying fresh air inlet
Drying air inlet flow for unit (Nm3/h) 4730
To be connected inlet. When air is taken to more than 3m. away, air drop must be considered an eventually
help with additional axial fans.
See drawing "DIAGRAM MACHINE CONNECTIONS"
Drying air outlet
Drying air outlet flow for unit (Nm3/h) 4970
To be connected outlet or to incinerator. ( To be done by customer after installation). When air is taken to
more than 3m. away, air drop must be considered an eventually help with additional axial fans.
See drawing "DIAGRAM MACHINE CONNECTIONS"
Heat source
Characteristics Technical information
Type of gas Natural Gas
Pressure (mbar.) 40
Maximum gas consumption for unit (Nm3/h) 30
Medium consumption calculated for unit (Nm3/h) 15
Feed pipe diameter ("G) 1
The installation of a gas pressure gauge at the inlet of the burners is recommended (not included in Comexi
scope of supply).
Heat dissipation
Heat emission to room (KW) 40
The calculated value is for a job at 120ºC in the tunnel with an ambient temperature of 20ºC