This document provides technical specifications for a machine including: - Electrical supply requirements of 102kW at 3x400V + PE and 50Hz. - Water supply requirements of 1-3 bar pressure and hardness of 2.5-4 mg/l. - Pneumatic supply requirements of 6-8 bar pressure and 434 l/min air consumption. - Exhaust flow rates for vapors, ozone, drying air inlet and outlet. - Heat source using natural gas at 40mbar pressure and max 30Nm3/h consumption. - Heat dissipation of 40KW to the room.

Uploaded by

adel haghi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
65 views3 pages

Power Supplies - MLK004100 PDF

This document provides technical specifications for a machine including: - Electrical supply requirements of 102kW at 3x400V + PE and 50Hz. - Water supply requirements of 1-3 bar pressure and hardness of 2.5-4 mg/l. - Pneumatic supply requirements of 6-8 bar pressure and 434 l/min air consumption. - Exhaust flow rates for vapors, ozone, drying air inlet and outlet. - Heat source using natural gas at 40mbar pressure and max 30Nm3/h consumption. - Heat dissipation of 40KW to the room.

Uploaded by

adel haghi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Machine: MLK004100

Client: “FİN-PLAST İNTERNATİONAL” LLC Drawing nº: 223295

TECHNICAL CHARACTERISTICS

Electrical supply

Characteristics Technical information

Maximum power (KW) 102


Electricity supply (V) 3 x 400V + PE
Frequency (HZ) 50
Maximum current absorbed (A) 154
Tensión of controls (V) 220/24
Input transformer (KVA) NO

The user’s main power line must be protected from any current overloads by means of safety switches
(magnetothermic switches) and differentials.
The differential relay on the automatic switch must be insulated against harmonic electrical current, pursuant
to in force regulation.
The differential relay must be adjusted current and timer. This differential relay must be adjusted to 300 mA.
We suggest using Schneider Electric VIGIREX, ref: RH99M relay, or equivalent.
The earthing system of the installation should not exceed 2 ohms.
We recommend to use a type TT ground connection System to avoid the risk of incidents in electronic
devices.

Internet connection

Ethernet connection will be required for machine start-up.


Ethernet IEEE 802.3
In case proxy/router is used, to enable remote connection, following ports, must remain open: 21, 25, 80, 110,
443, 11438
Downloading files will be required from server to enable remote connection.
File download must be permited from proxy.

Water supply

Characteristics Technical information

Minimum pressure (bar.) 1


Maximum pressure (bar.) 3
Hardness (CaCO3)(mg/l) 2,5 - 4
PH 7÷8,5
Inner filtering at (μ) 20
Temperature (ºC) 16 - 20
Maximum loss of main water inlet / outlet pressure (bar) 0,4 - 0,7
Connection diameter, inlet / outlet ("G) 3/4
Pneumatic supply

Characteristics Datos técnicos

Pneumatic supply Non-lubricated dry air


Pneumatic pressure (bar.) 6-8
Air consumption (l/min.) 434
Connection diameter ("G) 1/2

Coating unit vapors exhaust

Residual vapors exhaust flow (Nm3/h) 1400

All residual vapors exhaust have to be treated with pursuant to in force laws.
See drawing "DIAGRAM MACHINE CONNECTIONS"

Treater ozone exhaust

Treater ozone exhaust flow for unit (Nm3/h) 1250

All residual vapors have to be treated with pursuant to in force laws.


The diameter exhaust ozone of the piping has to be minimum Ø200mm, this piping must be with smooth
Surface and resistant to ozone.
The piping on the pressure side can be not longer than 8m and with maximum two 90º angles integrated in
the piping.
In case one of this points cannot be keep it is necessary to discuss the changes with an expert for exhaust
technique and air flow.
See drawing "DIAGRAM MACHINE CONNECTIONS"
Drying fresh air inlet

Drying air inlet flow for unit (Nm3/h) 4730

To be connected inlet. When air is taken to more than 3m. away, air drop must be considered an eventually
help with additional axial fans.
See drawing "DIAGRAM MACHINE CONNECTIONS"

Drying air outlet

Drying air outlet flow for unit (Nm3/h) 4970

To be connected outlet or to incinerator. ( To be done by customer after installation). When air is taken to
more than 3m. away, air drop must be considered an eventually help with additional axial fans.
See drawing "DIAGRAM MACHINE CONNECTIONS"

Heat source

Characteristics Technical information

Type of gas Natural Gas


Pressure (mbar.) 40
Maximum gas consumption for unit (Nm3/h) 30
Medium consumption calculated for unit (Nm3/h) 15
Feed pipe diameter ("G) 1

The installation of a gas pressure gauge at the inlet of the burners is recommended (not included in Comexi
scope of supply).

Heat dissipation

Heat emission to room (KW) 40

The calculated value is for a job at 120ºC in the tunnel with an ambient temperature of 20ºC