INPUT
Reference CODE: NSCP C101-15
Seismic ZONE 4
Seismic Zone Factor, Z 0.4 Table 208-3
Soil Profile Description Stiff Soil
Soil Profile Type SD Table 208-2
Seismic Source Type A
Distance to Seismic Source 9.90 km Poblacion, San Vicente
Na For Zone 4 only 1.00 Table 208-4
Nv For Zone 4 only 1.21 Table 208-5
Ca 0.44 Table 208-7 0 0.44176
Cv 0.77 Table 208-8 0 0.77312
R 8.5 Table 208-11A
Ct 0.0731 (0.030 in ft)for RC moment-resisting frames
hn 6.2 m
Building Total Wgt., W 5539.6 kN
3/4
Period, T = Ct (hn) 0.287 Eq. 208-8
Importance Factor, I 1.50 Table 208-1
Calculating V using Static Force Procedure according NSCP C101-15 Art. 208.5.5
= 0.4750W Eq. 208-4
= 0.1949W Eq. 208-5
= 0.0729W Eq. 208-6
= 0.0682W Eq. 208-7
V Total base shear = 0.195W= 1079.64 kN Art. 208.5.2.1
Ft at Top 0.00 kN Eq. 208-14
Eq. 208-15
You created this PDF from an application that is not licensed to print to novaPDF printer (http://www.novapdf.com)