Data Sheet for Design and Manufacture of Liquid-Immersed Power Transformers
of 500 kVA through 10,000 kVA up to 34.5 kV High Voltage Winding
Client Engineering Org. Spec. No.
Project Title Location Date
Project Location Contract No Equip. No.
Proj. No. Specifier Name Tele. No.
P.O. No.
Refer to Specification No. ELSTR01 For General Requirements
Applicable State & Local Codes:
Data Provided By Buyer Bidder With Proposal Seller After Order
Site Conditions: Accessories:
Altitude Ft Seismic Zone
Current Transformers (per Section 5.7.2)
Ambient Temperature: Max C Min C
Other unusual conditions:
H.V. Quantity Ratio Acc.Class
Rating : L.V. Quantity Ratio Acc.Class
OA Rating KVA (as per Section 5.1.2) Quantity Ratio
Neutral Acc.Class
Other Dissolved Gas Monitor (as per Section 5.7.4)
Sudden Pressure Relay (as per Section 5.7.5)
System parameters and Windings: Alarm/Auxiliary Relay Control Voltage Volts
High Voltage kV Phase Hertz
Delta Wye Insulating Liquid and Preservation System (per Section 6):
Solidly Grounded Resistance Grounded Ungrounded Mineral Oil (Type II as per ASTM D3487-88) (as per Section 6.1.2)
Copper Other Other (as per Section 6.1.3)
Low Voltage kV Phase Hertz Sealed Tank System with Purge Nozzle and Shutoff Valve
Delta Wye Inert Gas Pressure System (as per Section 6.2.2)
Solidly Grounded Resistance Grounded Ungrounded
Copper Other Special Requirements:
Transformer will supply Single Large Motor as Follows:
Impedance: Standard (as per Section 5.1.11) Other HP Voltage Full Load Amps
Bushing Location and Connection Method: Locked Rotor Amps Acceleration Time Seconds
High Voltage Line Top Mounted Air Terminal Chamber Other
Flanged Throat Other Test as listed in this Practice Witnessed Not Witnessed
Witnessed
High Voltage Neutral Temp Rise Lightning Impulse Temp Switching Impulse
Switching
Impulse
Lightning
Impulse
Switching
Top Mounted Air Terminal Chamber Impulse
Flanged Throat Other Front of Wave Radio Influence Voltage
Low Voltage Line Top Mounted Air Terminal Chamber Audible Sound Level Mechanical Pressure Test
Flanged Throat Other Other
Low Voltage Neutral Top Mounted Air Terminal Chamber
Flanged Throat Other Documentation:
Electronic Document Format .dxf Other
Space Heaters in Air Terminal Chambers: Seller to provide:
Thermostats Required Not Required no. of copies of all documentation plus
no. of copies of the operating manuals.
Cooling Fans:
Voltage Volts Remote Contact (as per Section 5.5.11) Efficiency Considerations (per Section 5.2):
Fan Failure Alarm Required (as per Section 5.7.3) Seller Shall Optimize Efficiency Based on:
Other Average Load: % Other %
Load (Copper) Losses: US$ / kw:
Alarm and Monitoring: Core (Iron) Losses: US$ / kw:
Voltage Volts
Other Requirements: