Service Bulletin
To:
SUBJECT:
BACKGROUND
INFORMATION:
COMPLIANCE:
PROOF OF
COMPLIANCE:
MODELS
AFFECTE!
Aircraft Manufacturers, Aircraft Engine Manufacturers, Distribu-
tors, Dealers, Engine Overhaul Facilities, Owners and Operators
of Slick Aircraft Magnetos.
Magneto Maintenance and Overhaul Schedules.
The service and warranty history of Slick magnetos clearly show
that the prescribed maintenance and overhaul schedules found in
Slick Maintenance and Overhaul manuals L-1020, L-1037, and L-
1363 are not being followed. Failure to properly perform the
prescribed inspections, maintenance, and overhaul procedures
Voids Slick warranty and may jeopardize the airworthiness of these
‘components resulting in possible serious equipment damage,
personal injury, or loss of life.
ALL AGENCIES OR INDIVIDUALS SERVICING ANY COMPO-
NENT MADE BY SLICK AIRCRAFT PRODUCTS MUST HAVE
THE MOST CURRENT REVISIONS OF SLICK MASTER SER-
VICE MANUAL F-1100 BEFORE PERFORMING MAINTE-
NANCE OR OVERHAUL. CONSULT SLICK REGARDING SUB-
SCRIPTION SERVICE INFORMATION.
As required.
Appropriate log book entries.
All 400 and 600 series magnetos
4000 and 4100 series magnetos
4200 and 6200 series magnetos
4300 and 6300 series magnetos
MAINTENANCE
PARTS AFFECTED: None
PARTS REQUIRED
PER BULLETIN: None
TOOLS REQUIRED
PER BULLETI None
ISSUED REVISED "Slick Aircraft Products PAGEN(
‘AY |v | wo | ony [vean
SS
01 | 80] 04 | 01 | 91
Unison Industries
530 Blackhawk Park Avenue sazs| 01 oF 04
Rockford, Illinois, U.S.A. 61104 IndustriesSB2-80C
SLICK Service Bulletin FAA APPROVED
WEIGHT CHANG!
None
DETAILED
INSTRUCTIONS:
400 AND 600 SERIES MAGNETOS — REFERENCE MANUAL L-1020
1. INSPECTION
These magnetos should be inspected externally every 100 hours and
internally every 500 hours. Consult Manual L-1020 for complete
Inspection procedures.
i, ADDITIONAL SERVICE INFORMATION
Slick Service Bulletins and Service Letters contain service information
criticalto the airworthiness and operation of particular magneto models.
Consult the most current revision of Slick Master Service Manual F-
1100 for applicability of special service information to particular mag-
neto models.
OVERHAUL
These magnetos should be completely overhauled as required by the
inspections noted above. Total time in service may not exceed the
manufacturer's TBO for the engine on which the magneto is installed.
When servicing magnetos use only the most current revision of Slick
manufactured parts. In most cases it may be easier to replace a faulty
magneto with a new, current production, factory assembled 4300 or
6300 Series magneto than to perform the overhaulin the field. Factory
assembled new and rebuilt 400 and 600 Series magnetos have been
discontinued and are no longer available from Slick.
IV. REPLACEMENT
These magnetos should be replaced as necessary when indicated by
the above inspections.
4000 / 4100 SERIES MAGNETOS:
|. INSPECTION
At each 200 hour interval the following inspections should be made:
1. Adjust timing to engine
2. General Inspection
a. Wiring connections and condition
b. Vent holes
c. P-lead attachment
|. OVERHAUL
These magnetos are certified by the FAA as factory-sealed and no
attempt should be made to overhaul or repair them in the field.
Replacement parts and service information are unavailable for these
magnetos. They are to be exchanged completely for new current
production repairable 4300 Series magnetos.
ISSUED REVISED Slick Aircraft Products PAGENO. || REVISION
we | onr[ va | wo | ony | vena! Unison Industries
aalraultaa aaliailse 530 Blackhawk Park Avenue Bie] 02 OF oF
Rockford, ilinois, U.S.A. 61104 IndustiesSLICK Service Bulletin $82;80C
removed from service and replaced. However, service history of these
magnetos indicate they have been routinely run in excess of 800 hours
and in many cases are not serviced until an operational or mechanical
failure occurs. The abuse to which these magnetos have been sub-
jected has forced Slick to re-establish parameters for time in operation
of 4000/4100 Series magnetos.
EFFECTIVE IMMEDIATELY: WITHIN THE NEXT 100 HOURS OF
OPERATION OR AT NEXT SCHEDULED ANNUAL INSPECTION.
ALL 4000 AND 4100 SERIES MAGNETOS WITH TIME INSERVICE
GREATER THAN 800 HOURS MUST BE REPLACED WITH THE
APPROPRIATE SLICK MODEL 4300 SERIES MAGNETO.
4200 / 6200 SERIES MAGNETOS — REFERENCE MANUAL L-1037
1. INSPECTION |
‘These magnetos should be inspected externally every 100 hours and
internally every 500 hours. Magneto rotor shaft bearings must be
replaced every 1000 hours. Consult latestrevision of ManualL-1037 for
complete inspection procedures.
i, ADDITIONAL SERVICE INFORMATION
Slick Service Bulletins and Service Letters contain service information
critical to the airworthiness and operation of particular magneto models.
Consult the most current revision of Slick Master Service Manual F-
1100 for applicability of special service information to particular mag-
neto models.
MW. OVERHAUL
These magnetos should be completely overhauled as required by the
inspections noted above. Total time in service may not exceed the
manufacturer's TBO for the engine on which the magneto is installed.
When servicing magnetos use only the most current revision of Slick
manufactured parts. In most casesit may be easier and more economi-
cal to replace a faulty magneto with a new current production factory
assembled unit than to perform the overhaul in the field.
Iv. REPLACEMENT
‘These magnetos should be replaced as necessary when indicated by
the above inspections. |
Ml, REPLACEMENT
These magnetos were designed to provide reliable service up to 800
hours. At 800 hours it was recommended that these magnetos be
4
Ss
é
ISSUED __[_ REVISED Slick Aircraft Products PAGENO. [| REVISION
ony [ww wo | ony [wean Unison Industies
530 Blackhawk Park Avenue ©1991 03 OF 04 c
pet he [inet be Rockford, linois, U.S.A. 61104 inant A;
SIVIVIVITIVITIVIVITITITTITITISTTTITASITIT TIT /,SLICK Service Bulletin £82;89C
4300 / 6300 SERIES MAGNETOS — REFERENCE MANUAL L-1363
1. INSPECTION
These magnetos should be inspected externally every 100 hours and
internally every 500 hours. Consultlatest revision of Manual L-1363 for
complete inspection procedures.
Ul. ADDITIONAL SERVICE INFORMATION
k Service Bulletins and Service Letters contain service information
critical to the airworthiness and operation of particular magneto models.
Consult the most current revision of Slick Master Service Manual F-
1100 for applicability of special service information to particular mag-
neto models.
Ml, OVERHAUL
These magnetos should be completely overhauled as required by the
inspections noted above. Total time in service may not exceed the
manufacturer's TBO for the engine on which the magneto is installed.
When servicing magnetos use only the most current revision of Slick
manufactured parts. Inmostcasesit may be easierand more economi-
cal to replace a faulty magneto with a new current production factory
assembled unit than to perform the overhaul in the field.
IV. REPLACEMENT
These magnetos should be replaced as necessary when indicated by
the above inspections. ;
4
WARRANTY: Void if prescribed maintenance schedules are not followed.
CHECK WITH SLICK TO BE SURE YOU HAVE THE MOST CUR-
RENT REVISIONS OF SLICK MANUALS F-1100, L-1020, L-1037,
-1363, AND PERTINENT SLICK SERVICE BULLETINS BEFORE
PERFORMING MAINTENANCE OR OVERHAUL.
ISSUED REVISED Slick Aircraft Products PAGENO. || REVISION
we, [ one [va [wo [ony [year Unison Industries
530 Blackhawk Park Avenue eee 04 OF 04 c
so Joe) O) Rockford, llinois, USA 61104 wags Ue