0% found this document useful (0 votes)
63 views1 page

PDVSA N-263 Rev.0, Oct.01 Data Sheet For Electrical Requirements For Packaged Equipment

This document provides electrical requirements for packaged equipment for a gas project in Anaco, Venezuela. It specifies service conditions such as operating temperature ranges and wind velocity. It also specifies area classification, medium and low voltage power supply details, motor requirements, control power sources, enclosure types, grounding and bonding, and documentation requirements including schematics, nameplates and operating manuals. Witness testing may be required and conformance to specifications and applicable codes is required.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
63 views1 page

PDVSA N-263 Rev.0, Oct.01 Data Sheet For Electrical Requirements For Packaged Equipment

This document provides electrical requirements for packaged equipment for a gas project in Anaco, Venezuela. It specifies service conditions such as operating temperature ranges and wind velocity. It also specifies area classification, medium and low voltage power supply details, motor requirements, control power sources, enclosure types, grounding and bonding, and documentation requirements including schematics, nameplates and operating manuals. Witness testing may be required and conformance to specifications and applicable codes is required.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

PDVSA N-263 Rev.0, Oct.

01
Data Sheet for Electrical Requirements for Packaged Equipment

Client PDVSA Engineering Org.       Spec. No. BE-88906


Project Title GAS ANACO Location SANTA ROSA Date JULY 14, 2003
Project Location ANACO Contract No       Equip. No.      
Proj. No. FS0127 Specifier Name       Tele. No.      
P.O. No.      
Refer to Specification PDVSA N-263 For General Requirements
Applicable State & Local Codes:      
Data Provided By Buyer  Seller With Proposal  Seller After Order
Service Conditions (4.1): Heating Elements & Contactors (4.7.3):
Altitude 1000 m Seismic Zone 4 Circuit Breaker Fused Disconnected Switch
Ambient Temperature: Max 40 C Min. 15 C
Design Wind Velocity 10.8 MPH Approved Enclosure (4.8):
Indoor Outdoor Type: NEMA 12 NEMA 4 NEMA 4X NEMA 7/4
Other:      
Area Classification (4..1.4., 4.2.9): Material Galv. Steel Stainless Steel Cast Aluminum

Unclassified Classified Non-Metallic Aluminum Other      


Class 1 Group D Division 2 Lowest AIT    
Zone       DCS Relays (4.9.3):
24-Volt Coil Other      
Medium-Voltage Power Supply (4.2.5):
Volts       Phase       Wire       Hertz       Pushbuttons, Selector Switches, & Control Stations (4.10.1):
Fault Current       System Grounding      

Low-Voltage Power (4.2.6): Control Stations (4.10.3):


Option a-Buyer supplies 460-volt, three-phase starters & contactors Grouped
Option b-Seller supplies 460-volt, three-phase starters & contactors
Volts       Phase       Wire       Hertz       Indicating Light Colors (4.10.5):
Number, Material, & Size of Conductors/Phase       Red Function Work. Green Function N. Work.
Fault Current       System Grounding      
Additional Disconnecting Means (4.2.12)
Transformer Enclosure (4.12.4):
Control Power (4.2.7, 4.2.8): Manufacturer Standard Aluminum Stainless Steel
Separately Derived by Seller By Buyer
Volts DC AC Phase 3 Wire 3 Hertz 60 Control Panels (4.13.1):
Additional Disconnecting Means (4.2.12) On Skid Off Skid

LV Motors (4.3): Control Panes Space Heaters (4.13.9):


Less than 460 VAC (4.3.1) HP Range      Volts      Phase     Thermostat No Thermostat
460 VAC Motors (4.3.2) HP Range      
PIP ELSMT01 Other       Conduit (4.15.1):
Provide Space Heaters on Motors 75 HP and above Galvanized Steel Aluminum Other      

MV Motors (4.3.3): Clamps & Support (4.15.7):


PIP ELSMT02 PIP ELSMT03 Other       Hot-Dipped Galvanized Electroplated Zinc
HP Range Volts      
Grounding and Bounding (4.16.4)
Motor Control Wiring (4.4.4): Provide External Bonding Jumpers
3-Wire Control 2-Wire Control Per Attached Schematic(s)
Nameplate Material (4.17.1)
Combination Motor Starter Protection (4.5.1.a): Laminated Plastic Stainless Steel Other      
Circuit Breaker Fused Disconnected Switch
Witness Testing (5.1.1):
Overload Relays (4.5.5): Required Not Required
Electro-Mechanical Electronic (Solid State)
Automatic Reset Ambient Compensated Documentation (6.2):
Class 20 Class 10 Schematic Diagrams
Overload Trip Light Manufacturer's Standard By Buyer
Electronic Document Format : .DXF Other .DWG
Grouped Motor Controlled (4.6.1): Seller to Provide:
Not Allowed Allowed 1 Reproducible plus
3 Number of copies of all documentation plus
3 Copies of the operating manuals
Additional Documentation Requirements      
Other:      