0% found this document useful (0 votes)
146 views12 pages

RBS 6000 3G Commissioning Guide

The document provides steps to commission an RBS 6000 3G network node with 11 steps: 1. Format drives and load basic package 2. Configure cabinet equipment 3. Load OAM and site equipment scripts 4. Run IUB and optional DSCP scripts 5. Integrate the RBS with the network 6. Create the on-air configuration version 7. Set the on-air version The document also provides tools needed which include a laptop, software like Java and the RBS Element Manager, cables, and configuration scripts. It describes how to connect to the RBS remotely using Putty or HyperTerminal and configure the network node.

Uploaded by

Abebe Sharew
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
146 views12 pages

RBS 6000 3G Commissioning Guide

The document provides steps to commission an RBS 6000 3G network node with 11 steps: 1. Format drives and load basic package 2. Configure cabinet equipment 3. Load OAM and site equipment scripts 4. Run IUB and optional DSCP scripts 5. Integrate the RBS with the network 6. Create the on-air configuration version 7. Set the on-air version The document also provides tools needed which include a laptop, software like Java and the RBS Element Manager, cables, and configuration scripts. It describes how to connect to the RBS remotely using Putty or HyperTerminal and configure the network node.

Uploaded by

Abebe Sharew
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 12

Step to Commissioning RBS 6000 3G

No Activity
1 Format DUW (/c2 & /d)
2 Load Basic Package
3 Configure/load Cabinet Equipment Configuration
4 Load OAM.xml script
5 Load Site Equipment.xml script
6 Run IUB.mo script
7 Run DSCP.mo script --> optional
8 Do Upgrade Software --> optional
9 Call Integrator to integrate RBS
10 Create CV_On-air
11 Set CV_On-air

Tool for Commissioning RBS 6000 3G


1 Laptop with OS : Windows
2 Software:
- Java 1.5 or more
- RBS Element Manager
- Hyper Terminal or Putty
3 Cable:
- Serial Cable + USB to Com adapter (Aten/Prolific/BAFO)
- LAN Cable
4 Scripts :
- Cabinet.xml (optional)
- OAM.xml
- Site Equipment.xml
- IUB.mo
- DSCP.mo (optional)
5 FTP
- Filezilla client / Total commander
- Filezilla Server or BPFTP
6 RBS Software
- Basic Package
- Upgrade Package
Result
DUW blank Putty + serial cable
Basic_CV Filezilla Client + Lan Cable
Initial_CV RBS Element Manager (EMAS)
OAM_CV
SE_CV
IUB_CV (sometimes engineer must creat CV manually)
DCSP_CV (sometimes engineer must creat CV manually)
Rb_CV, Su_CV_Fi_CV (optional to create Upgrade_CV) Filezilla Server + EMAS
RBS On Air test call, speed test, video call
Check Radio Network --> all enable
- startable
- rollbacklist=1
- reload with this CV
Remark
sometimes this step already
in factory

Optional
Setup RBS Element Manager (EMAS):
1) Plug in the serial cable to Port LMT A in the DUW.

2) Open Software Hyper terminal / putty with below setting:


> Speed : 9600
> data bits : 8
> stop bits : 1
> parity : none
> flow control : none
Enter username dan password:
> username : rbs
> password : rbs

Cek IP address port LMT B ---> $ifconfig

> le0 is the interface port LMT B


> IP address default : 169.254.1.1 / 255.255.0.0

3) Plug in LAN cable to port LMT B in DUW.

4) Setup IP address laptop


Firewall and antivirus must be OFF

6) Element Manager (EMAS) can be downloaded from RBS :


> Install Java 1.5 dulu
> Open internet explorer, type http://<ip address RBS>/em/index.html
> Dowload dan install EMAS

7) Open EMAS, enter IP RBS and click "connect".


Steps to format RBS
Tool:
1. Serial Cable + USB to Com
2. Hyper Terminal / Putty
3. FTP Client (contoh: WSFTP/Filezilla Client)
4. Software Basic Package
5. LAN Cable
6. RBS Element Manager

Steps:
1. Open Putty, set RBS into "backup mode"
> $reload --

2. Show folder /c2 in RBS (it is hidden by default)


> $mount_c2
> Check folder /c2 --> $vols

3. Format RBS
> format /d --> $formathd /d
> format /c2 --> $formathd /c2
> Re-Check the volume of Hard drive of RBS --> $vols (usage 0%)

4. Set RBS still in backup mode


> $reload --

5. Setup IP address RBS


> $ifconfig le0 169.254.1.1 netmask 255.255.0.0
> Check setting IP success:
> $ifconfig
> ping IP RBS via command prompt (cmd) --> ping 169.254.1.1 --> reply from 169.254.1.1

6. Open Filezilla Client


> Click Transfer --> transfer type --> binary
> Host : 169.254.1.1 (IP RBS)
> username : rbs
> password : rbs
> klik Quick connect

7. Transfer folder /d dan /c2 from laptop ke RBS


> block folder /c2 dan /d from Basic Package in Laptop, right click --> upload.
> Wait until finish

8. Set back RBS into "Active Mode"


> $reload
> RBS create Basic_CV (automatic)

9. Wait 10-15 minutes (login server ready)


rbs
rbs

10. Connect LAN cable to LMT B using EMAS, ready to configure Cabinet Equipment Configuration
Command in Hyper Terminal / Putty

cv ls check all CV in RBS


cv cu check the status of CV (startable/loaded/executing/rollback, dll)
cv set name_cv set CV as startable cv
cv mk name_cv create new CV
cv rm name_cv remove CV

reload restart
reload refresh
reload cold
reload coldwtest
reload --

ifconfig to check the IP of RBS


vols to check the volume of each directory/drive in RBS Hard drive
setclock to set the RBS clock
readclock to check the RBS clock
formathd /c2 to format drive /c2
mount_c2 to activate drive /c2
passwd set password

ply from 169.254.1.1


pment Configuration
Configure MSSM in RBS 6000
Prinsip MSSM:
In 1 cabinet RBS 6000, only 1 DU as primary node, the rest are secondary node.

DUW as Secondary Node:


1.Plug EC Cable from DUW to SHU port A5, A6, or A7 (RBS 6102/6201) dan port ECB/ECY (RBS 6601).
2. Open EMAS, change into "Containment (MOM based)"
3. Click "EquipmentSupportFunction=1"
Make Sure "SupportSystemControl" = false
4. Open MO Equipment=1, Subrack=1, Slot=1, PlugInUnit=1
> Menu MO-->add
> MO class = EcPort
> ID = 1
> HubPosition = A5 or A6 or A7 (RBS 6201/6102/6301/6102) and ECB/ECY (RBS 6601)
> Click "add" botton
6. Create Add_node_A6 and Set Startable
(RBS 6601).