Training Slide C&I Smart PV Solution - Inverter - SDongle 4G-WLAN - Smartlogger3000A
Training Slide C&I Smart PV Solution - Inverter - SDongle 4G-WLAN - Smartlogger3000A
1 Huawei Confidential
Contents
01 Products Overview
02 Installation
03 Commissioning
2 Huawei Confidential
1.1 FusionSolar C&I Range of Inverters up to 100KTL
3 Huawei Confidential
1.2 Communication Options
4 Huawei Confidential
1.3 Power Meter Options
5 Huawei Confidential
1.4 FusionSolar APP, Web UI & Smart PV Management System
6 Huawei Confidential
Downloading FusionSolar APP
Method 1: Search for "FusionSolar" in Google Play to download and install the app.
Google Play
(Android)
Method 2: Scan the QR code to download and install the app. https://intl.fusionsolar.huawei.com
FusionSolar Server
(Android)
QR code link:
https://intl.fusionsolar.huawei.com/appVersionManage/downloadA
ppVersion?appType=1
8 Huawei Confidential
1.6 Smart Dongle Networking
Number of
cascaded
Smart Power Mgt.
Master Inverter Slave Inverters Communication inverters AFCI Ripple Control
Sensor System
(including
master inverter)
• WLAN Smart Dongle: not Applicable to
SUN2000- Applicable to system
supporting slave inverter, system only
12/15/17/20KTL- only consist of
SUN2000- replaced by WLAN-FE DTSU666-H consist of
M0/M2, 29.9KTL, SUN2000-12-20KTL-
12/15/17/20KTL- Smart Dongle N ≤ 10 250A/50mA FusionSolar SUN2000-12-
33KTL-A, 36KTL, M0/M2
M0/M2 • 4G Smart Dongle (Three Phase) 20KTL-M0/M2,
50/60KTL-M0, (Inverter has built-in
• WLAN-FE Smart Dongle 36KTL (AFCI
100KTL-M1 RRCR interface)
(connected to master inverter) model)
SUN2000-
12/15/17/20KTL- Compatible smart
SUN2000- M0/M2, 29.9KTL, • 4G Smart Dongle meter
N ≤ 10 FusionSolar No No
50/60KTL-M0 33KTL-A, 36KTL, (connected to master inverter) listed in Appendix
50/60KTL-M0, 2
100KTL-M1
SUN2000-
12/15/17/20KTL- Compatible smart
SUN2000- M0/M2, 29.9KTL, • 4G Smart Dongle meter
N ≤ 10 FusionSolar No No
100KTL-M1 33KTL-A, 36KTL, (connected to master inverter) listed in Appendix
50/60KTL-M0, 2
100KTL-M1
9 Huawei Confidential
1.6 Smart Dongle Networking
• Configure the components in the dotted box as
Local Commissioning:
required. • SUN2000-12/15/17/20KTL-M0/M2: Inverter built-in WLAN communicates to FusionSolar
• In hybrid networking scenarios, if the Smart Power App.
Sensors is DTSU666-H 250A/50mA, the master • SUN2000-29.9KTL, 33KTL-A, 36KTL, 50/60KTL-M0, 100KTL-M1: FusionSolar App
inverter is recommended to be SUN2000- connects to the inverter via USB-Adapter2000-C
12/15/17/20KTL-M0/M2. For other compatible smart
meters, the master inverter should be SUN2000-
50/60KTL-M0 or 100KTL-M1. Remote Monitoring
• For master inverter SUN2000-12/15/17/20KTL-M0/M2: Optional WLAN or Ethernet
communication to FusionSolar Smart PV Management System via Smart Dongle WLAN-
FE.
• For master inverter SUN2000-12/15/17/20KTL-M0/M2, 50/60KTL-M0, 100KTL-M1:
Optional 4G communication to FusionSolar Smart PV Management System via Smart
Dongle 4G.
DTSU666-H 250A/50mA three phase smart power sensor or compatible smart meter listed
in Appendix 2 connects to inverter via RS485 for power output monitoring or control. In the
Smart Dongle networking scenario, the duration of export limitation is less than 5 s.
Built-in RRCR (Radio Ripple Control Receiver) interface allows to control the inverter‘s
power production through 4 digital inputs. Ripple Control Device is applicable only to
Germany.
10 Huawei Confidential
1.7 SmartLogger Networking
Number of
Smart Power Mgt.
SmartLogger Inverters Communication cascaded EMI AFCI Ripple Control
Sensor System
inverters
Applicable to
SUN2000-
system only
12/15/17/20KTL- Compatible
Compatible EMI consist of
SmartLogger30 M0/M2, 29.9KTL, smart meter
RS485 N ≤ 80 listed in FusionSolar SUN2000-12- Yes
00A 33KTL-A, 36KTL, listed in
Appendix 3 20KTL-M0/M2,
50/60KTL-M0, Appendix 2
36KTL (AFCI
100KTL-M1
model)
11 Huawei Confidential
1.7 SmartLogger Networking
SmartLogger: SmartLogger3000A
Note Inverters: max 80 inverters are connected.
Configure the components in the dotted
box as required. Local Commissioning:
• Web UI software installed laptop connecting to
SmartLogger3000A via its Ethernet port
• FusionSolar App connecting to SmartLogger3000A
via its built-in WLAN communication
Remote Monitoring:
• SmartLogger3000A communicates to FusionSolar
Smart PV Management System via Ethernet
• SmartLogger3000A communicates to FusionSolar
Smart PV Management System via built-in 4G
12 Huawei Confidential
Contents
01 Products Overview
02 Installation
03 Commissioning
13 Huawei Confidential
2.1 Installation Video for Inverters
14 Huawei Confidential
2.2 Installation Video for Communication Options
15 Huawei Confidential
Document Link for Inverters
Category Document Link (Support-E)
(Video) SUN2000- (12KTL-M0, 15KTL-
M0, 17KTL-M0, 20KTL-M0) Installation English German French Dutch Italian Portuguese Spanish Polish
(2020.03.13) (2020.03.13)
Video
(Video) SUN2000- (29.9KTL, 33KTL-A,
Installation 36KTL, 42KTL) Installation Video English
Video
(Video) SUN2000- (50KTL, 60KTL,
English
65KTL) -M0 Installation Video
(Video) SUN2000- (100KTL, 110KTL,
English German French Spanish
125KTL) Series Installation Video
SUN2000- (12KTL-M0, 15KTL-M0,
English German French Dutch Italian Portuguese
17KTL-M0, 20KTL-M0) User Manual
SUN2000- (29.9KTL, 33KTL-A, 36KTL,
English German French Dutch Italian Portuguese Spanish Turkish Korean
42KTL) User Manual
User Manual
SUN2000- (50KTL, 60KTL, 65KTL) -M0
English German French Portuguese Spanish Turkish
User Manual
SUN2000- (100KTL, 110KTL, 125KTL)
English German French Spanish Korean
Series User Manual
SUN2000- (12KTL-M0, 15KTL-M0,
English German French Dutch Italian Portuguese Spanish Polish
17KTL-M0, 20KTL-M0) Quick Guide (2020.03.13) (2020.03.13)
16 Huawei Confidential
Document Link for Networking Devices
Category Document Link (Support-E)
(Video) FusionSolar APP Commissioning Video
English German French Dutch Italian
(SUN2000-12/15/17/20KTL-M0/M2)
Commisioning (Video) FusionSolar APP Commissioning Video English
Video (SUN2000-50/60KTL-M0, 100KTL-M1)
17 Huawei Confidential
2.3 Installation for Networking Devices
Smart Dongle Networking Scenario
Pin: Definition
(12KTL-20KTL) - Function Description
29.9KTL, 33KTL-A, 36KTL 50/60KTL-M0 100KTL-M1
M0
1: 485A1-1 1: RS485A IN (RS485-1) 1: RS485A IN (RS485-1) 1: RS485A IN (RS485-1) RS485 differential signal+
3: 485B1-1 3: RS485B IN (RS485-1) 3: RS485B IN (RS485-1) 3: RS485B IN (RS485-1) RS485 differential signal– Used to cascade inverters or
connect to the RS485 signal port on
2: 485A1-2 2: RS485A OUT (RS485-1) 2: RS485A OUT (RS485-1) 2: RS485A OUT (RS485-1) RS485 differential signal+ the SmartLogger
4: 485B1-2 4: RS485B OUT (RS485-1) 4: RS485B OUT (RS485-1) 4: RS485B OUT (RS485-1) RS485 differential signal–
7: 485A2 N/A 5: RS485A IN (RS485-2) 7: RS485A IN (RS485-2) RS485 differential signal+ Used to connect to an RS485
signal port on a Smart Power
9: 485B2 N/A 7: RS485B IN (RS485-2) 8: RS485B IN (RS485-2) RS485 differential signal– Sensor for export limitation
18 Huawei Confidential
2.3 Installation for Networking Devices
SmartLogger Networking Scenario
• In the SmartLogger networking scenario, the Smart Dongle cannot
be connected.
• A maximum of 80 devices can connect to a single SmartLogger, such
as inverters, Smart Power sensor, and EMI. You are advised to
connect fewer than 30 devices to each RS485 route.
• The Smart Power Sensor is necessary for export limitation. Select
the Smart Power Sensor according to the actual project.
• To ensure the system response speed, the Smart Power Sensor is
recommended to be connected to a COM port separately from
inverter COM port.
Pin: Definition
(12KTL-20KTL) - Function Description
29.9KTL, 33KTL-A 50/60KTL-M0 100KTL-M1
M0
1: 485A1-1 1: RS485A IN (RS485-1) 1: RS485A IN (RS485-1) 1: RS485A IN (RS485-1) RS485 differential signal+
3: 485B1-1 3: RS485B IN (RS485-1) 3: RS485B IN (RS485-1) 3: RS485B IN (RS485-1) RS485 differential signal– Used to cascade inverters or
connect to the RS485 signal port on
2: 485A1-2 2: RS485A OUT (RS485-1) 2: RS485A OUT (RS485-1) 2: RS485A OUT (RS485-1) RS485 differential signal+ the SmartLogger
4: 485B1-2 4: RS485B OUT (RS485-1) 4: RS485B OUT (RS485-1) 4: RS485B OUT (RS485-1) RS485 differential signal–
19 Huawei Confidential
2.4 Installation Troubleshooting
If polarity of the DC input power cable is reversed and the DC switch is ON, do not turn off the DC switch immediately or unplug positive
and negative connectors. The device may be damaged if you do not follow the instruction. This damage is not covered under any
warranty or service agreement. Wait until the solar irradiance declines at night and the PV string current reduces to below 0.5 A, and
then turn off the DC switch and remove the positive and negative connectors. Correct the string polarity before reconnecting the string to
the SUN2000.
Power-Off for Troubleshooting
20 Huawei Confidential
Contents
01 Products Overview
02 Installation
03 Commissioning
21 Huawei Confidential
3.1 Commissioning Video
22 Huawei Confidential
3.2 Register an Installer Account
• Creating the first installer account will generate a domain named after the company.
• Self-registration on
login interface Installer Role
VAP • Highest level account
Account • Right to create and
manage sub-
accounts
Log in to the registered email
and activate the account. Distributor 1
Installer Role
Employee 1
The email address is the Employee 2
user name for logging in to
the FusionSolar app.
Employee 3
• To create multiple installer accounts for the same company, log in to the
Installer 1 Installer 2 Installer Role
FusionSolar app and tap New User.
Installer 1 Installer 1
xxx
Installer 2
Installer
23 Huawei Confidential
3.3 Access Device Commissioning
Method 1: mobile phone connected to the Internet
24 Huawei Confidential
3.3 Smart Dongle Commissioning
Master inverter: SUN2000-12/15/17/20KTL-M0/M2
If the inverter has been connected to FusionSolar management system successfully, the steps in dashed boxes are skipped automatically.
25 Huawei Confidential
Master inverter: SUN2000-12/15/17/20KTL-M0/M2
Method 1: 4G Communication
Parameter Description
APN mode • Set the parameters related to
Identification the SIM card. The
type parameters are obtained
APN from the SIM card carrier.
APN dialup • When APN mode is set to
number Automatic by default, APN,
APN dialup number, APN
APN user
user name, and APN user
name
password are not displayed.
APN user When APN mode is set to
password Manual, APN related Method 2: FE Communication
PIN parameters are displayed.
You can set the parameters.
• The PIN code is
usually at the back
of a SIM card.
• If the automatic dialing is successful,
4G parameters are not displayed.
If Ethernet is displayed, it
The parameter synchronization
indicates that the network
result is displayed in the
cable is not properly
connected. In this case, inverter cascading scenario.
reconnect the network cable.
26 Huawei Confidential
Master inverter: SUN2000-12/15/17/20KTL-M0/M2
Follow-up Procedure 1: Checking the Device Status
Advanced User
28 Huawei Confidential
Master inverter: SUN2000-50/60KTL-M0, 100KTL-M1
Parameter Description
APN mode • Set the parameters related to
Identification the SIM card. The
type parameters are obtained
APN from the SIM card carrier.
APN dialup • When APN mode is set to
number Automatic by default, APN,
APN dialup number, APN
APN user
user name, and APN user
name
password are not displayed.
APN user When APN mode is set to
password Manual, APN related
PIN parameters are displayed.
You can set the parameters.
The parameter synchronization
• The PIN code is result is displayed in the
usually at the back inverter cascading scenario.
of a SIM card.
• If the automatic dialing is successful,
4G parameters are not displayed.
29 Huawei Confidential
Master inverter: SUN2000-50/60KTL-M0, 100KTL-M1
LED Remarks Description
LED Description
Color Status
Color Status
Green
N/A Off Normal The Dongle is not secured or is not powered on.
Successfully connected to the
Steady on
management system. Yellow (blinking The Dongle is secured and powered on.
Blinking at short The inverter is communicating with green and red Steady on
intervals (on for the management system through simultaneously)
0.2s and then off the Dongle. Scan the QR code
for 0.2s) Green Blinking in a 2-second cycle Normal Dialing (duration < 1 min)
of the Smart Dongle
or the inverters (on for 0.1s and then off for Abnormal If the duration is longer than 1 min, the 4G parameter
LED connected to it. 1.9s) settings are incorrect. Reset the parameters.
Blinking at long intervals Normal The dial-up connection is set up successfully (duration <
(on for 1s and then off for 30s) .
1s) Abnormal If the duration is longer than 30s, the settings of the
management system parameters are incorrect. Reset the
parameters.
Steady on Normal Successfully connected to the management system.
Blinking at short intervals The inverter is communicating with the management
(on for 0.2s and then off for system through the Dongle.
0.2s)
Red Steady on Abnormal The Dongle is faulty. Replace Dongle.
The Dongle has no SIM card or the SIM card is in poor
Blinking at short intervals
contact. Check whether the SIM card has been installed
(on for 0.2s and then off for
or is in good contact. If not, install the SIM card or
0.2s)
remove and insert the SIM card.
The Dongle fails to connect to the management system
because it has no signals, weak signal, or no traffic. If
Blinking at long intervals the Dongle is reliably connected, check the SIM card
(on for 1s and then off for signal through the APP. If no signal is received or the
1s) signal strength is weak, contact the carrier. Check
whether the tariff and traffic of the SIM card are normal.
If not, recharge the SIM card or buy traffic.
Blinking red and No communication with the inverter
green alternatively Blinking at long intervals • Remove and insert the Dongle.
(on for 1s and then off for • Check whether inverters match the Dongle.
1s) • Connect the Dongle to other inverters. Check whether
the Dongle or the USB port of the inverter is faulty.
30 Huawei Confidential
3.4 SmartLogger Commissioning
Method 1: FusionSolar app
1. Before connecting to the app, ensure that the WLAN function has been enabled on the SmartLogger. By
default, the WLAN function is available within 4 hours after the SmartLogger is powered on. In other cases,
hold down the RST button (for 1s to 3s) to enable the WLAN function.
RST Operation Function
Indicator Status Meaning
When WLAN is set to OFF in idle state, hold down the RST button for 1s to 3s to power on the
Blinking green slowly
Hold down the button WLAN module. The alarm/maintenance indicator (ALM) then blinks green fast for 2 minutes (other (on for 1s and then
Local maintenance is in
for 1s to 3s. indicators are off) and the SmartLogger waits for connecting to the app. If the app fails to be progress.
off for 1s)
connected, the WLAN module is automatically powered off after it is powered on for 4 hours. ALM
Blinking green fast Local maintenance fails or the
(on for 0.125s and connection to the app is to be
Hold down the button Within 3 minutes after the SmartLogger is powered on and restarted, hold down the RST button for then off for 0.125s) set up.
for more than 60s. more than 60s to restart the SmartLogger and restore factory settings. Steady green Local maintenance succeeded.
31 Huawei Confidential
Method 1: FusionSolar app
3. Add communications devices connected to the SmartLogger.
Tap Add device to add a smart power sensor. The DTSU666-H smart
power sensor is used as an example. Set Device Type to Power
Meter, Port number to the ID of the SmartLogger COM port
connected to the smart power sensor, and Address to 11, and then
tap OK.
Tap Auto Device Search to add inverters. You can also add inverters
manually.
If not all devices are detected due to duplicate communications
addresses, tap Auto Assign Address to assign and adjust the
addresses as prompted.
32 Huawei Confidential
Method 1: FusionSolar app
4. Set the network parameters of the SmartLogger.
Method 1: When the SmartLogger connects to the Huawei
Hosting Cloud over the wireless network, set Monthly traffic
• Method 2: When the SmartLogger connects to the Huawei
Hosting Cloud over a wired network, set Ethernet parameters.
package and Network mode parameters.
• Set Monthly traffic package and Network mode based on the SIM card • When DHCP is set to , Ethernet parameters of the SmartLogger are
information. automatically allocated.
• By default, APN mode is set to Automatic. When this mode cannot be used to • When DHCP is set to , you can manually set Ethernet parameters. Set IP
access the Internet, set the parameter to Manual. In this case, set the address and Subnet mask for the SmartLogger according to the network plan.
parameters related to the SIM card with the information obtained from the carrier. Ensure that the SmartLogger and the router are on the same network segment and
• Perform operations based on 4G module status. When 4G module status is that the SmartLogger has a different IP address from other devices on the LAN. Set
Connected and an IP address has been assigned, SmartLogger dialup is Default gateway and Primary DNS server to the IP address of the LAN router.
successful. • If Primary DNS server cannot resolve the domain name, use Secondary DNS
server.
33 Huawei Confidential
Method 1: FusionSolar app
5. Set parameters for connecting the SmartLogger to the Huawei Hosting Cloud.
Parameter Description
Set Server to
Server
sg5.fusionsolar.huawei.com.
Port number Set Port number to 27250.
Address mode Set Address mode to Logical address.
SSL encryption Set SSL encryption to .
Secondary challenge Set Secondary challenge
authentication authentication to .
34 Huawei Confidential
Method 2: WebUI
1. Set the IP address for the PC on the same network segment as
the SmartLogger IP address.
Port IP Settings SmartLogger Default Value PC Setting Example
IP address 192.168.8.10 192.168.8.11
LAN port Subnet mask 255.255.255.0 255.255.255.0
Default gateway 192.168.8.1 192.168.8.1
• When the IP address of the WAN port is on the 192.168.8.1– IP address 192.168.0.10 192.168.0.11
192.168.8.255 network segment, the IP address of the LAN port is
automatically switched to 192.168.3.10, and the default gateway is WAN port Subnet mask 255.255.255.0 255.255.255.0
192.168.3.1. If the connection port is a LAN port, adjust the network Default gateway 192.168.0.1 192.168.0.1
configuration of the PC accordingly.
• It is recommended that the PC be connected to the LAN port.
2. Enter https://XX.XX.XX.XX in the address box of the browser (XX.XX.XX.XX is the IP address of the SmartLogger) . If you log in to the WebUI for the first
time, a security risk warning is displayed. Click Continue to this website.
3. Log in to the WebUI. 4. On the Deployment Wizard page, set parameters as prompted. For
Parameter Description details, see Help on the page.
Language Set this parameter as required. During parameter setting, click Previous, Next, or Skip as required.
User name Select admin.
• The initial password is
Changeme.
• Use the initial password
upon first power-on and
change it immediately after
login..
Password
• If you enter wrong
passwords for five
consecutive times in 5
minutes, your account will be 5. After the parameters are configured, click Finish.
locked out. Try again 10
minutes later.
35 Huawei Confidential
7. Create a PV plant.
Method 2: WebUI
6. Enter the Huawei Hosting Cloud address https://intl.fusionsolar.huawei.com
in the address box of a browser. Log in to the Huawei Hosting Cloud. If no
account or password is available, create an account.
8. Enter the basic information, access device, string configuration, electric price
configuration, other information, and camera information based on the site requirements.
Click Save. The PV plant is successfully created.
Camera Information
• Enter the SN and name
of the SmartLogger. After
the SmartLogger is
added, the inverters and
smart power
sensor/power meter
connected to the
SmartLogger are
automatically added.
• If the capacity of the PV
plant is greater than 25
kWp, the Camera
Information tab page is
displayed.
36 Huawei Confidential
Contents
01 Products Overview
02 Installation
03 Commissioning
37 Huawei Confidential
4.1 Upgrading Devices
Method 2: Manually downloading firmware
SUN2000-12/15/17/20KTL-M0/M2
Method 1: Auto firmware detection and upgrade during setup wizard when internet available
Automatic
firmware detection
Automatic
firmware upgrade
38 Huawei Confidential
Other devices Obtain the latest firmware from Huawei.
Upgrade device by app: upgrade the firmware version of devices as required. Upgrade device by SmartLogger WebUI: upgrade the firmware of the SmartLogger or solar
inverter over the WebUI.
SUN2000-50/60KTL-M0, 100KTL-M1
Batch Upgrade solar inverters in batches. 1.Select the upgrade package and click
Upgrade Upload.
2.Click Upgrade.
SmartLogger
Insert the USB flash drive where the firmware is saved into the USB port on the Upgrade device by FusionSolar WebUI: upgrade the firmware of the SmartLogger,
SmartLogger. SmartDongle and solar inverter over the WebUI.
Huawei technical support
center uploads the upgrade
package to FusionSolar.
Upload the
firmware to the
USB flash drive .
39 Huawei Confidential
4.2 Exporting Device Logs Export device logs by app: You can tap Log management or Device Logs to
export operation logs.
SUN2000-12/15/17/20KTL-M0/M2 SUN2000-50/60KTL-M0, 100KTL-M1
SmartLogger
A USB flash drive has been inserted into the USB port on the Export device logs by SmartLogger WebUI: Select the device whose logs
SmartLogger. are to be exported and click Export Log.
Logs of two or more types of devices cannot be exported at a time. For example,
you cannot select both SUN2000 and SmartLogger.
Logs can be exported for a maximum of five devices of the same type at a time.
40 Huawei Confidential
Bring digital to every person, home, and
Thank you.
organization for a fully connected,