Xi RX Afro3 Aq en - S
Xi RX Afro3 Aq en - S
com
RX-AFRO3-AQ
Installation Manual
1. Safety notes
WARNING! The system cannot be used for biologically contaminated water or water of unknown origin.
The system must be installed by a trained plumbing personnel. Only use original spare parts, filter elements and accessories manufactured
by Aquafilter”. Compliance with the instructions is necessary for the:
- Trouble-free operation;
- Implementation of claims upon malfunction.
1) Read the installation manual before starting the installation of the system.
2) Check if all of the components have been included with the system (see section 6. Contents).
3) The unit must be washed after installation (see section 12), as well as after each filter or osmotic membrane replacement and also in the
event of a prolonged non-use of the system (e.g. during holidays). The unit must then be left for 5-6 hours in order to activate
environmental filtering.
4) Before disconnecting the tubing, you must first remove the safety clip from the quick connection fitting and then press it against the
flange symmetrically.
5) When disconnecting the tubing, it should be ensured that it isn't bent in any place (correctly fitted tubing is recessed by about 1.5 cm into
the quick connection fitting).
6) When connecting or disconnecting the tubing, the position of fittings screwed into the body of osmotic membrane, must not be changed.
7) After attaching the tubing to the quick connection fitting, the connection must be secured with a safety clip.
8) Only Teflon tape can be used to seal the plastic threads. Hemp must not be used.
9) Do not use aggressive cleaning agents for washing the body of the unit. The body should be thoroughly washed before the installation of
the membrane.
10) When installing a new linear filter you must be aware of the direction of water flow (water flow in the right direction is indicated by the arrow
on the label of each linear filter).
11)Wash your hands thoroughly before and after replacing the filter or membrane.
12) The osmotic membrane should be removed from its packaging some time prior to installing it in the membrane housing.
13) In the event of a leak, immediately disconnect the unit from its water source.
14) The flow restrictor should be cleaned once every 12 months.
15)Water intended for reverse osmosis filtration must meet certain conditions (see section 4).
16)When the system is not being used, close valves BV250W-JG, as well as valve SEWBV1414.
17)The manufacturer is not liable for any damage arising from the use of the system for any other purposes than water filtration.
18)The manufacturer is not responsible for printing errors.
19)We reserve the right to make any changes or additions to the published specifications without notice.
Only use original filters and filtration membranes manufactured by Aquafilter. In the event of using elements of a different brand, the
manufacturer does not accept liability for incorrect operation of the system or any related damage.
Reverse Osmosis is a separation process that uses pressure to force water Cross-section of TFC membrane element
through a semi-permeable membrane while retaining other substances on
the other side – it's a reverse process of what naturally takes place in all living
cells. The membrane stops 96-99% of organic and non-organic SEAL WATER INLET
contaminants, bacteria and viruses. Semi-permeable membrane consists
of many layers winded up on perforated core. Contaminated water enters the
membrane element with pressure, forcing water molecules to pass through PERFORATED CORE
the microscopic membrane pores, while flushing out contaminants to a drain.
FILTERED WATER
OUTLET
* the system must be equipped with stop valves for water (valve on the inlet to drain, valve on the outlet of pure water).
The absence of these valves will reduce the life of the Reverse Osmosis membrane.
7. Connecting tubing to the quick connection fitting JG (John Guest) and QC (Quick
Connector) types
Detaching the tubing:
1) Remove the safety clip from the quick connection fitting (if there is one) (fig. 1).
2) Press the quick connection fitting flange symmetrically (fig. 2).
3) Pull out the tubing (fig. 3).
Connecting the tubing:
1) Push the tubing into the quick connection fitting (correctly installed tubing is recessed by 1.5 cm in the quick coupling fitting) (fig. 4).
2) Install the safety clip (if there is one) (fig. 5).
7.1. Removing and installing the fitting in the filter (new filter with a threaded elbow)
Removing the fitting from the filter:
1) Remove the safety clip from the quick connection fitting(fig. 1).
2) Press the quick connection fitting flange symmetrically (fig. 2).
3) Remove the straight fittings from the old filter (on the inlet and outlet of water) (fig. 3).
4) Remove the old Teflon tape from the thread of the fitting (fig. 4).
5) Roll several layers of the Teflon tape onto the thread of the fitting. The tape must be wound in the opposite direction to the thread.
(fig. 5).
Installing the fitting in the filter:
1) Install the elbow in a new filter. When screwing in the elbow, do not pull back on it as it can lead to loss of pressurization and leakage
of water (fig. 6).
1 2
Disconnect the tubing from the inlet elbow of the osmotic Unscrew the housing of the membrane.
membrane housing.
WARNING! Remove the safety clip from the quick
connection fitting first!
3 4
Insert the osmotic membrane into the body (the membrane must Lubricate the O-rings with white cosmetic Vaseline, and firmly
be inserted with the nozzle with two O-rings in the direction of the tighten the osmotic membrane housing. WARNING! Care must
bottom of the housing). be taken to ensure no seals are damaged.
WARNING! Ensure that there is a sealing flange on the
membrane.
WARNING! The manufacturer is not responsible for mechanical damage caused by inappropriate installation and/or operation, as
well as in the event of the system being used in a different manner than intended. The system should be installed in areas where the
temperature is greater than 2°C.
1 2
Close-off the valve on the cold water pipe. Detach the flexible hose from the valve.
WARNING! There is a rubber gasket between the valve and
the hose – do not lose it.
3 4
Screw the chrome fitting onto the pipe so as to facilitate the Roll several layers of the Teflon tape onto the thread of the
screwing of the valve as well as opening and closing it. stop valve.
WARNING! Remember to put in gaskets in the appropriate
joints.
5 6
Screw the valve into the chrome fitting. Apply the nut onto the tubing which should be connected to the
valve, push the tubing to the end and tighten the nut.
7
Connect the second end of the tubing to the in-line filter one the
water inlet to the system.
WARNING! Remove the safety clip from the quick
connection fitting.
During the installation ensure that the rubber tubing is not
bent in any place.
WARNING! The manufacturer is not responsible for mechanical damage caused by inappropriate installation and/or operation, as
well as in the event of the system being used in a different manner than intended. The system should be installed in areas where the
temperature is greater than 2°C.
1 2
Close-off the valve supplying water. Remove the tap from the wall.
3 4
Screw the chrome fitting onto the pipe supplying cold water so as Roll several layers of the Teflon tape onto the thread of the stop
to facilitate the screwing of the valve as well as opening and valve.
closing it.
WARNING! Remember to put in gaskets in the appropriate
joints.
5 6
Screw the valve into the chrome fitting. Apply the nut onto the tubing which should be connected to the
valve, push the tubing to the end and tighten the nut.
7 8
Screw the chrome fitting onto the pipe supplying hot water. Screw the tap onto the fittings installed.
WARNING! Remember to put in gaskets in the appropriate
joints.
Connect the second end of the tubing to the in-line filter one the
water inlet to the system.
WARNING! Remove the safety clip from the quick
connection fitting.
During the installation ensure that the rubber tubing is not
bent in any place.
10. Installation of drainage
1 2
To prevent damage to the drain pipe use a center punch and a Using a drill and a drill bit (5mm), drill a hole in the drain pipe,
hammer to carefully mark the location where to drill in the drain in the previously marked area.
pipe. WARNING! The axis of the hole should be perpendicular to
WARNING! Choose an easily accessible place for drilling. the pipe axis. drill in one of the pipe walls only.
3 4
Install the clamp onto the drain pipe so that the axis of the joint of Screw the two halves of the clamp together.
the tubing coincides with the axis of the hole. WARNING! Check the tightness of the joint.
5 6
Insert the rubber tubing into the quick connection fitting on the Insert the other end of the tubing into the BV250W-JG valve.
clamp. WARNING! Remove the safety clip from the quick connector
WARNING! Remove the safety clip from the quick coupling fitting before inserting the tubing. Put the safety clip back on
fitting before inserting the tubing. Put the safety clip back on once the tubing is inserted.
once the tubing is inserted.
7 8
Insert the tubing into the other side of BV250W-JG valve. Connect the second end of the tubing to the flow restrictor.
WARNING! Remove the safety clip from the quick connector WARNING! Remove the safety clip from the quick
fitting before inserting the tubing. Put the safety clip back on connection fitting before inserting the tubing. Put the safety
once the tubing is inserted. clip back on once the tubing is inserted.
11. Installation of pure water tubing
1 2
Connect the tubing to the elbow in the housing of the osmotic Connect the other end of the tubing with BV250W-JG valve.
membrane. WARNING! Remove the safety clip from the quick connector
WARNING! Remove the safety clip from the quick fitting before inserting the tubing. Put the safety clip back on
connection fitting before inserting the tubing. Put the safety once the tubing is inserted.
clip back on once the tubing is inserted.
1 2
FLOW
420
Screw the two hangers onto one wall of the cabinet under the Clip the body (system) into the two hangers.
sink. WARNING! When installing the system in the holders,
ensure that the rubber tubing is not bent in any place.
60
55 5
50 min 10
45 15
40 20
35 25
30
1) Before disconnecting the tubing, you must first remove the safety clip from the quick connection fitting, and then press it against the flange
symmetrically.
2) When disconnecting the tubing, it should be ensured that it isn't bent in any place (correctly fitted tubing is recessed by about 1.5 cm into
the quick coupling fitting).
3) When connecting and disconnecting the tubing, care must be taken to ensure that the position of fittings screwed into the body of osmotic
membrane is not changed.
4) Once the tubing has been inserted into the quick connection fitting, it should be secured with a safety clip.
5) Only Teflon tape can be used to seal the plastic threads. Tows must not be used.
6) Do not use aggressive cleaning agents for washing the body of the unit. The body should be thoroughly washed before the installation of
the membrane.
7) When installing a new in-line filter you must be aware of the direction of water flow (water flow in the right direction is indicated by the
arrow on the label of each in-line filter).
8) Wash your hands thoroughly before and after replacing the filter or membrane.
9) The membrane should be removed from its package some time prior to installing it in the membrane housing.
10)In the event of a leak, immediately disconnect the unit from its water source.
11)The flow restrictor should be cleaned once every 12 months.
Only use original filters and filtration membranes manufactured by Aquafilter. In the event of using elements of a different brand, the
manufacturer does not accept liability for incorrect operation or any related damage.