0% found this document useful (0 votes)
43 views11 pages

Xi RX Afro3 Aq en - S

The document is an installation manual for an Aquafilter RX-AFRO3-AQ reverse osmosis water filtration system. It contains 20 sections that provide instructions on safety, installation, maintenance, and operation of the system. Key details include: - The system uses reverse osmosis filtration technology to remove 96-99% of contaminants by forcing water through a semi-permeable membrane. - It is designed to filter 280 liters of water per day with an operating pressure of 2.8-6 bars and temperature of 2-45°C. - The manual provides specifications for water quality parameters and contains diagrams of the water flow and system components. - Installation

Uploaded by

Stratos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views11 pages

Xi RX Afro3 Aq en - S

The document is an installation manual for an Aquafilter RX-AFRO3-AQ reverse osmosis water filtration system. It contains 20 sections that provide instructions on safety, installation, maintenance, and operation of the system. Key details include: - The system uses reverse osmosis filtration technology to remove 96-99% of contaminants by forcing water through a semi-permeable membrane. - It is designed to filter 280 liters of water per day with an operating pressure of 2.8-6 bars and temperature of 2-45°C. - The manual provides specifications for water quality parameters and contains diagrams of the water flow and system components. - Installation

Uploaded by

Stratos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

www.aquafilter.

com

RX-AFRO3-AQ
Installation Manual
1. Safety notes
WARNING! The system cannot be used for biologically contaminated water or water of unknown origin.
The system must be installed by a trained plumbing personnel. Only use original spare parts, filter elements and accessories manufactured
by Aquafilter”. Compliance with the instructions is necessary for the:
- Trouble-free operation;
- Implementation of claims upon malfunction.

1) Read the installation manual before starting the installation of the system.
2) Check if all of the components have been included with the system (see section 6. Contents).
3) The unit must be washed after installation (see section 12), as well as after each filter or osmotic membrane replacement and also in the
event of a prolonged non-use of the system (e.g. during holidays). The unit must then be left for 5-6 hours in order to activate
environmental filtering.
4) Before disconnecting the tubing, you must first remove the safety clip from the quick connection fitting and then press it against the
flange symmetrically.
5) When disconnecting the tubing, it should be ensured that it isn't bent in any place (correctly fitted tubing is recessed by about 1.5 cm into
the quick connection fitting).
6) When connecting or disconnecting the tubing, the position of fittings screwed into the body of osmotic membrane, must not be changed.
7) After attaching the tubing to the quick connection fitting, the connection must be secured with a safety clip.
8) Only Teflon tape can be used to seal the plastic threads. Hemp must not be used.
9) Do not use aggressive cleaning agents for washing the body of the unit. The body should be thoroughly washed before the installation of
the membrane.
10) When installing a new linear filter you must be aware of the direction of water flow (water flow in the right direction is indicated by the arrow
on the label of each linear filter).
11)Wash your hands thoroughly before and after replacing the filter or membrane.
12) The osmotic membrane should be removed from its packaging some time prior to installing it in the membrane housing.
13) In the event of a leak, immediately disconnect the unit from its water source.
14) The flow restrictor should be cleaned once every 12 months.
15)Water intended for reverse osmosis filtration must meet certain conditions (see section 4).
16)When the system is not being used, close valves BV250W-JG, as well as valve SEWBV1414.
17)The manufacturer is not liable for any damage arising from the use of the system for any other purposes than water filtration.
18)The manufacturer is not responsible for printing errors.
19)We reserve the right to make any changes or additions to the published specifications without notice.
Only use original filters and filtration membranes manufactured by Aquafilter. In the event of using elements of a different brand, the
manufacturer does not accept liability for incorrect operation of the system or any related damage.

2. Filtering technology of reverse osmosis

Reverse Osmosis is a separation process that uses pressure to force water Cross-section of TFC membrane element
through a semi-permeable membrane while retaining other substances on
the other side – it's a reverse process of what naturally takes place in all living
cells. The membrane stops 96-99% of organic and non-organic SEAL WATER INLET
contaminants, bacteria and viruses. Semi-permeable membrane consists
of many layers winded up on perforated core. Contaminated water enters the
membrane element with pressure, forcing water molecules to pass through PERFORATED CORE
the microscopic membrane pores, while flushing out contaminants to a drain.

FILTERED WATER
OUTLET

REJECTION OUTSIDE PROTECTIVE LAYER


SEMI-PERMEABLE LAYER

3. Technical specifications of the systems

Operating temp.......................................................................................................................................................................from 2°C to 45°C


Operating pressure.................................................................................................................................................................2,8 bar — 6 bar
Output*...........................................................................................................................................................................280 l/day (TFC-7F5F)
Water inlet..................................................................................................................................................................................................1/2”
* nominal output
4. Parameters of water supplied to the RO system *
pH range..................................................................................................................................................................................................2 -11
Max total hardness..................................................................................................................................................................400 ppm3 (mg/l)
Ì?x alkalinity........................................................................................................................................................................................8 mval/l
Iron and manganese content...............................................................................................................................................< 0.05 ppm3 (mg/l)
1
Max SD Index ..........................................................................................................................................................................................SDI5
2 3
? ?x TDS ...............................................................................................................................................................................2000 ppm (mg/l)
1
SDI (Sild Density lndex) — a very important factor when designing a reverse osmosis system.
It expresses the ability of water to contaminate the membrane. Its value must be < 5.
2
TDS (Total Disolved Solids) — salinity of water
3
ppm — parts per million.
* the distributor is not liable for any damage resulting from the use of water with parameters that do not meet the above requirements.
* the distributor is not liable for any damage resulting from the use of water with parameters that do not meet the above requirements.
crude water influent
5. Water flow diagram

pure water outlet


wastewater effluent - clamping ring connection
6. Contents

Chrome-plated adapter Teflon tape Shut off valve


RO system Membrane housing Wrench for the quick
with seal TAS0004 SEWBV1414
RX-AFRO3-AQ wrench connectors
FXWR AQCWW-W FT06
(1/2” MIP x 1/2” FIP x 1/4” FIP)

Tubing 2 x mounting clip Drain clip Installation 2 x stop valve*


C2500W SC500B14 manual BV250W-JG
XI-RO

* the system must be equipped with stop valves for water (valve on the inlet to drain, valve on the outlet of pure water).
The absence of these valves will reduce the life of the Reverse Osmosis membrane.

7. Connecting tubing to the quick connection fitting JG (John Guest) and QC (Quick
Connector) types
Detaching the tubing:
1) Remove the safety clip from the quick connection fitting (if there is one) (fig. 1).
2) Press the quick connection fitting flange symmetrically (fig. 2).
3) Pull out the tubing (fig. 3).
Connecting the tubing:
1) Push the tubing into the quick connection fitting (correctly installed tubing is recessed by 1.5 cm in the quick coupling fitting) (fig. 4).
2) Install the safety clip (if there is one) (fig. 5).

Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5

7.1. Removing and installing the fitting in the filter (new filter with a threaded elbow)
Removing the fitting from the filter:
1) Remove the safety clip from the quick connection fitting(fig. 1).
2) Press the quick connection fitting flange symmetrically (fig. 2).
3) Remove the straight fittings from the old filter (on the inlet and outlet of water) (fig. 3).
4) Remove the old Teflon tape from the thread of the fitting (fig. 4).
5) Roll several layers of the Teflon tape onto the thread of the fitting. The tape must be wound in the opposite direction to the thread.
(fig. 5).
Installing the fitting in the filter:
1) Install the elbow in a new filter. When screwing in the elbow, do not pull back on it as it can lead to loss of pressurization and leakage
of water (fig. 6).

Fig. 1 Fig. 2 Fig. 3

Fig. 4 Fig. 5 Fig. 6


8. Preparing the system for installation – installing RO membrane

1 2

Disconnect the tubing from the inlet elbow of the osmotic Unscrew the housing of the membrane.
membrane housing.
WARNING! Remove the safety clip from the quick
connection fitting first!

3 4

Insert the osmotic membrane into the body (the membrane must Lubricate the O-rings with white cosmetic Vaseline, and firmly
be inserted with the nozzle with two O-rings in the direction of the tighten the osmotic membrane housing. WARNING! Care must
bottom of the housing). be taken to ensure no seals are damaged.
WARNING! Ensure that there is a sealing flange on the
membrane.

WARNING! After installing the membrane, check if all the


connections are faultless, and if all the quick coupling
connections are secured with safety clips.

Connect the tubing to the inlet of the housing of the osmotic


membrane. WARNING! Secure the connection with the
safety clip.
9. Installation

WARNING! The manufacturer is not responsible for mechanical damage caused by inappropriate installation and/or operation, as
well as in the event of the system being used in a different manner than intended. The system should be installed in areas where the
temperature is greater than 2°C.

1 2

Close-off the valve on the cold water pipe. Detach the flexible hose from the valve.
WARNING! There is a rubber gasket between the valve and
the hose – do not lose it.

3 4

Screw the chrome fitting onto the pipe so as to facilitate the Roll several layers of the Teflon tape onto the thread of the
screwing of the valve as well as opening and closing it. stop valve.
WARNING! Remember to put in gaskets in the appropriate
joints.

5 6

Screw the valve into the chrome fitting. Apply the nut onto the tubing which should be connected to the
valve, push the tubing to the end and tighten the nut.
7

Connect the second end of the tubing to the in-line filter one the
water inlet to the system.
WARNING! Remove the safety clip from the quick
connection fitting.
During the installation ensure that the rubber tubing is not
bent in any place.

9.1. Installation in a wall-tap - Optional

WARNING! The manufacturer is not responsible for mechanical damage caused by inappropriate installation and/or operation, as
well as in the event of the system being used in a different manner than intended. The system should be installed in areas where the
temperature is greater than 2°C.

1 2

Close-off the valve supplying water. Remove the tap from the wall.

3 4

Screw the chrome fitting onto the pipe supplying cold water so as Roll several layers of the Teflon tape onto the thread of the stop
to facilitate the screwing of the valve as well as opening and valve.
closing it.
WARNING! Remember to put in gaskets in the appropriate
joints.
5 6

Screw the valve into the chrome fitting. Apply the nut onto the tubing which should be connected to the
valve, push the tubing to the end and tighten the nut.

7 8

Screw the chrome fitting onto the pipe supplying hot water. Screw the tap onto the fittings installed.
WARNING! Remember to put in gaskets in the appropriate
joints.

Connect the second end of the tubing to the in-line filter one the
water inlet to the system.
WARNING! Remove the safety clip from the quick
connection fitting.
During the installation ensure that the rubber tubing is not
bent in any place.
10. Installation of drainage

1 2

To prevent damage to the drain pipe use a center punch and a Using a drill and a drill bit (5mm), drill a hole in the drain pipe,
hammer to carefully mark the location where to drill in the drain in the previously marked area.
pipe. WARNING! The axis of the hole should be perpendicular to
WARNING! Choose an easily accessible place for drilling. the pipe axis. drill in one of the pipe walls only.

3 4

Install the clamp onto the drain pipe so that the axis of the joint of Screw the two halves of the clamp together.
the tubing coincides with the axis of the hole. WARNING! Check the tightness of the joint.

5 6

Insert the rubber tubing into the quick connection fitting on the Insert the other end of the tubing into the BV250W-JG valve.
clamp. WARNING! Remove the safety clip from the quick connector
WARNING! Remove the safety clip from the quick coupling fitting before inserting the tubing. Put the safety clip back on
fitting before inserting the tubing. Put the safety clip back on once the tubing is inserted.
once the tubing is inserted.

7 8

Insert the tubing into the other side of BV250W-JG valve. Connect the second end of the tubing to the flow restrictor.
WARNING! Remove the safety clip from the quick connector WARNING! Remove the safety clip from the quick
fitting before inserting the tubing. Put the safety clip back on connection fitting before inserting the tubing. Put the safety
once the tubing is inserted. clip back on once the tubing is inserted.
11. Installation of pure water tubing

1 2

Connect the tubing to the elbow in the housing of the osmotic Connect the other end of the tubing with BV250W-JG valve.
membrane. WARNING! Remove the safety clip from the quick connector
WARNING! Remove the safety clip from the quick fitting before inserting the tubing. Put the safety clip back on
connection fitting before inserting the tubing. Put the safety once the tubing is inserted.
clip back on once the tubing is inserted.

12. Fixing of the system in the hangers

1 2
FLOW
420

Screw the two hangers onto one wall of the cabinet under the Clip the body (system) into the two hangers.
sink. WARNING! When installing the system in the holders,
ensure that the rubber tubing is not bent in any place.

60
55 5
50 min 10
45 15
40 20
35 25
30

Flush the system with approximately 15 liters of water. Flushing


time should not be shorter than 60 minutes.
WARNING! This water is not suitable for consumption.
WARNING! Once done, the system can be used.
13. Filter elements

Type of filter Description longevity* Size

AIPRO - in-line mechanical cartridge for cold water. Removes 10” x 2”


sand, rust, silt dirt particles. 3 - 6 months (25 cm x 5,08 cm)

AICRO in-line cartridge filled with coconut shell activated carbon.


Removes chlorine and organic substances. Improves the taste 10” x 2”
3 - 6 months (25 cm x 5,08 cm)
and odour of water

RO membrane. Effectively removes 96-99% of impurities from 11,9” x 1,8”


up to 36 months. (30 cm x 4,5 cm)
water (including most bacteria and viruses)

*depends on water quality.

Replacing filters and membranes – Important information.


Replacing filters or osmotic membranes must be done in accordance with
sections 7. - 7.1. and the following requirements.

1) Before disconnecting the tubing, you must first remove the safety clip from the quick connection fitting, and then press it against the flange
symmetrically.
2) When disconnecting the tubing, it should be ensured that it isn't bent in any place (correctly fitted tubing is recessed by about 1.5 cm into
the quick coupling fitting).
3) When connecting and disconnecting the tubing, care must be taken to ensure that the position of fittings screwed into the body of osmotic
membrane is not changed.
4) Once the tubing has been inserted into the quick connection fitting, it should be secured with a safety clip.
5) Only Teflon tape can be used to seal the plastic threads. Tows must not be used.
6) Do not use aggressive cleaning agents for washing the body of the unit. The body should be thoroughly washed before the installation of
the membrane.
7) When installing a new in-line filter you must be aware of the direction of water flow (water flow in the right direction is indicated by the
arrow on the label of each in-line filter).
8) Wash your hands thoroughly before and after replacing the filter or membrane.
9) The membrane should be removed from its package some time prior to installing it in the membrane housing.
10)In the event of a leak, immediately disconnect the unit from its water source.
11)The flow restrictor should be cleaned once every 12 months.

Only use original filters and filtration membranes manufactured by Aquafilter. In the event of using elements of a different brand, the
manufacturer does not accept liability for incorrect operation or any related damage.