0% found this document useful (0 votes)
101 views24 pages

SRW01 Brochure R04 en - US

The SRW01 is a low-voltage electric motor management system with communication capabilities. It has a modular design that allows expansion of functions and easy assembly. Key features include support for DeviceNet, Modbus, and Profibus protocols, a USB port for programming and monitoring, and optional digital and current measurement modules. Programming and configuration can be done through free software or the optional HMI.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
101 views24 pages

SRW01 Brochure R04 en - US

The SRW01 is a low-voltage electric motor management system with communication capabilities. It has a modular design that allows expansion of functions and easy assembly. Key features include support for DeviceNet, Modbus, and Profibus protocols, a USB port for programming and monitoring, and optional digital and current measurement modules. Programming and configuration can be done through free software or the optional HMI.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Motors | Automation | Energy | Transmission & Distribution | Coatings

SRW01
Smart Relay
www.weg.net

SRW01
The SRW01 is a low-voltage electric motor management system with state-of-the-art technology and
network communication capabilities. Additionally, its modular concept allows the expansion of its
funcionalities, Plug and Play philosophy, free WLP programming software and USB communication.

Versatility
The SRW01 supports the following communication networks
protocols: DeviceNet, Modbus-RTU, and Profibus-DP.
The communication modules can be easily exchanged due to
its plug and play capabilities.

The SRW01 provides a USB port for relay monitoring,


programming and back-up on-line the parameters through
PC when using WLP software.

The SRW has a HMI that can be used for quick system
monitoring and relay parameterization. Additionally, the
internal memory allows the user to do the upload and
download of up to three parameters set and three user
programs.

The SRW01 includes a thermal memory circuit in order to


maintain a motor thermal image, even if power supply if is
removed.

Flexibility
The SRW01 has a modular design, providing easy
assembling and integration.

The Control Unit (UC) can be assembled with the Current


Measuring Unit (UMC) or current and voltage measuring unit
(SRW01-UMCT), forming a single unit, or separated (up to 2
meters).

The SRW01 has pre-programmed operation modes,


which operates in several kinds of starting and monitoring
modes. One of them is the transparent mode that can be
programmed according to your needs, making the SRW01 fit
to the most diverse applications.

The digital input and output functions of the Control Unit (UC)
are automatically configured as the operation mode is
selected, defining in an easy and simple way the connection
between the control circuit and the SRW01 in the starter.

The digital inputs can be configured to monitor external


digital signals using the external fault funciton. With this
feature the user can connect the output contact from an
external relay to the digital input of the SRW01 relay. Thus the
relay SRW01 makes possible the user to use various
protections for a motor in a same relay, as earth leakage and
thermal like PTC.

* The current and voltage measuring unit (UMCT) only allows separate
assembly of the Control Unit (UC).

SRW01 3
www.weg.net

Modular Design
The SRW01 incorporates a main Control Unit SRW01-UC and The relay allows to add digital inputs and outputs through the
a Current Measuring Unit (SRW01-UMC) or a current and digital expansion module.
voltage measuring unit (SRW01-UMCT) that are electrically This management system is a modular design, providing more
connected using a flat cable SRW01-CB. flexibility in the design, project and assembly the motor starter.

The interface with the relay may be performed in three ways: Through Fieldbus, the user can operate, monitor and
configure the SRW01 remotely, via PLC or supervisory
g Via Fieldbus (Modbus, DeviceNet, Profibus) system.
g Via SRW01-HMI The HMI is connected to SRW01 through cable connection
g Via software - WLP (USB) that can be programmed, operated and monitored in a
use-friendly way.
The interaction can be done via software through a shielded
USB cable or via Modbus network, through the WLP.

4 SRW01
www.weg.net

Modular Design
Characteristics
g Reduced size, compact structure
g Control Unit (UC) input power range: 110-240 V ac/dc or 24 V ac/dc

g Control Unit (UC) with 4 digital inputs and 4 digital outputs

g DIN rail or screws mounting

g Easy network module change, via exclusive drawer system

g Programming via free WLP software or HMI (optional)

PTC or ground leakage sensor input

Led indicator for digital input


Reset

Mini USB port

Profibus - DP network connection

Connection for EDU and IHM

Modbus, DeviceNet Led indicator for digital output


or Profibus - DP connection

Communication module

The SRW01-UC Control Unit provides LED indicators


for input and output activations, status, operation
mode, power supply status, failure and alarm status.
The mounting of the Control Unit can be done either by
35 mm DIN rail or onto back panel mounting.

Communication protocols: DeviceNet, Modbus, and


Profibus are defined using proper protocol installed in
the communication drawer.

The Plug and Play concept automatically recognizes


and configures the SRW01 for safe operation, avoiding
manual error configuration.

SRW01 5
www.weg.net

Modular Design
Digital Expansion Unit (EDU)
Provides the option of increasing the number of digital inputs and outputs.
It has 6 digital inputs and 4 digital outputs, totalizing 10 digital inputs and 8
digital outputs, with the inputs and outputs of the Control Unit (UC).
It can be used to transfer information, alarm signalling or external devices
state.
*Maximum of 1 digital expansion unit (EDU) for 1 Control Unit (UC).

Current Measuring Unit (UMC) or Current and Voltage Measuring Unit (UMCT)

The Current Measuring Unit (UMC) measures the current of the three
motor phases.

Using a current and voltage measuring unit (UMCT), in addition to


measuring the motor currents (as in the UMC), it is also possible to monitor
voltages up to 690 V ac, phase sequence, power factor, all the motor
powers and make management and electric power consumption (kW/h).

The values are digitally transmitted to the Control Unit (UC).

UMC UMCT

Free Programming Software - WLP (WEG Ladder Programmer)


g SRW01 parametrization, programming, command and monitoring
g Configures, edits the parameters and programs in “Ladder” language
with mathematical and control blocks
g Configuration assistant
g USB or Modbus network communication

Configuration assistant
USB connection

Monitoring diagnosis

6 SRW01
www.weg.net

Benefits

g WLP Software free


g USB port to connect the relay with the computer
g Back-up the relay configuration using the software WLP
g Downtime reduction
g Power factor monitoring and consumption, via current and voltage measuring unit (UMCT)
g Higher reliability in the motor protection system
g Safety during the operation, monitoring and maintenance
g Modularity and easy system expansion
g Reduction of the control wiring
g Reduced hardware responsible for motor control
g Remote reset via fieldbus network
g Quick and accuracy in identifying failures or alarms
g Automatic defect records and statistics
g Monitoring, supervision and control via fieldbus network, computer (WLP) or human-machine interface

Functions
The SRW01 protection, monitoring and operating functions enhance system protection reliability and precision. The operating
modes are auto-adjustable, meaning that the user selects the operating mode and the relay search for proper parameters
automatically. This feature ensures quick and safe parameterization. All operating modes allow motor monitoring. Its friendly
parameterization mode allows users to access all digital inputs and outputs, thus increasing flexibility to cover many applications.

Protection Operating Modes


g Overload protection (adjustable tripping class 5-45) g Transparent operation - Digital input and output can be

g Thermal protection via PTC configured according to application needs. In this operation
g Phase loss protection mode the UMC/UMCT is used
g Protection against current unbalance between phases g Operation as overload relay - similar to an overload relay

g Protection against overcurrent and locked rotor g Direct starter - direct-on-line starter for single and three

g Protection against undercurrent phase motors


g Internal ground fault protection g Reversing starter - reversing starter for three phase motors

g Protection against out of range frequency g Star-Delta starter - star-delta starter switch for three phase

g Earth Leakage motors


g External Fault g Dahlander starter- starter for Dahlander three phase

g Phase Sequence* motors


g Voltage Unbalance* g Two windings starter - starter for two windings three phase

g Phase Loss (voltage)* motors


g Over and undervoltage* g PLC mode - similar to the running of a PLC

g Over and underpower* In this operation mode the UMC/UMCT is not used
g Over and under power factor*

g Management consumption kWh and kVArh*

Monitoring
g Digital input and output activation
g RMS current of each phase and average in amperes

or % of In adjusted current
g Line and average voltage (V)

g Motor frequency

g Number of activation per failute type

g Number of start ups

g Motor running hours

g Relay running hours

g Phase unbalance levels

g Internal ground fault level

g Earth leakage current

g Power factor*

g Consumption*

g Active, reactive and apparent power*

g PTC value

* Available only using UMCT


SRW01 7
www.weg.net

Applications
The main function of the SRW01 is to protect and control Due to its reduced size and modular design, the relay is
electric motors in their most diverse industrial applications. frequently used when space for its assembly is a determining
point, e.g. in Intelligent Motor Control Centers.

Its high reliability and precision make the


SRW01 suitable for the toughest
industrial applications.
The on-line monitoring options, failure
diagnosis and failure statistics allow
preventive maintenance to be more
effective, thus reducing the number of
downtimes.
It offers wide application for continuous
process plants in the following market
segments:

g Chemical and Petrochemical


g Pulp and Paper
g Mining and Cement
g Food and Beverage
g Metal and Fabrication
g Plastics and rubber
g Automotive
g Ceramics
g Textile
g Refrigeration
g Other segments

8 SRW01
www.weg.net

Selection Guide
UC - Control Unit

SRW01-U C P T 1 E47
Communication protocol
B = Without communication
D = DeviceNet
M = Modbus
P = Profibus

Protection
E - Earth leakage
T - PTC

Digital input operating voltage


1 = 24 V dc
2 = 110 V ac

Supply voltage
E26 - 24 V ac (50-60 Hz) / V dc
E47 - 110-240 V ac (50-60 Hz) / V dc

Reference Protection Supply voltage Communication protocol Digital input voltage

SRW01-UC-BE1E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 24 V dc


SRW01-UC-BE1E26 Earth leakage 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-BE2E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-BE2E26 Earth leakage 24 V ac (50-60Hz) / V dc 110 V ac
Without communication
SRW01-UC-BT1E47 PTC 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-BT1E26 PTC 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-BT2E47 PTC 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-BT2E26 PTC 24 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-DE1E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-DE1E26 Earth leakage 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-DE2E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-DE2E26 Earth leakage 24 V ac (50-60Hz) / V dc 110 V ac
DeviceNet
SRW01-UC-DT1E47 PTC 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-DT1E26 PTC 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-DT2E47 PTC 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-DT2E26 PTC 24 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-PE1E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-PE1E26 Earth leakage 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-PE2E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-PE2E26 Earth leakage 24 V ac (50-60Hz) / V dc 110 V ac
Profibus-DP
SRW01-UC-PT1E47 PTC 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-PT1E26 PTC 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-PT2E47 PTC 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-PT2E26 PTC 24 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-ME1E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-ME1E26 Earth leakage 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-ME2E47 Earth leakage 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-ME2E26 Earth leakage 24 V ac (50-60Hz) / V dc 110 V ac
Modbus
SRW01-UC-MT1E47 PTC 110-240 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-MT1E26 PTC 24 V ac (50-60Hz) / V dc 24 V dc
SRW01-UC-MT2E47 PTC 110-240 V ac (50-60Hz) / V dc 110 V ac
SRW01-UC-MT2E26 PTC 24 V ac (50-60Hz) / V dc 110 V ac

SRW01 9
www.weg.net

Accessories
Current Measuring Unit (UMC) or Current and Voltage Measuring Unit (UMCT)
Shall be chosen according to motor rated current.
Current range (A) Current Measuring (UMC) Current and Voltage Measuring (UMCT) 1)
0.5-5 SRW01-UMC1 SRW01-UMCT1
1.25-12.5 SRW01-UMC2 SRW01-UMCT2
2.5-25 SRW01-UMC3 SRW01-UMCT3
12.5-125 SRW01-UMC4 SRW01-UMCT4
42-420 SRW01-UMC5 SRW01-UMCT5
84-840 SRW01-UMC6 SRW01-UMCT6

1) Alternating Voltage Range from 35 to 690 V


Note: The Control Unit (UC) can be assembled with the Currente Measuring Unit (UMC), creating a unique unit, or detached (until 2 meters). The Current and
Voltage Measuring Unit (UMCT) exclusively can assembled detached with the Control Unit.

Width (mm) Current (A) Power connection


0.25 - 2.5 2)
0.5 - 5
45 Cable through UMC
1.25 - 12.5
2.5 - 25

SRW01-UMC1, 2 and 3 SRW01-UMCT1, 2 and 3 2) For current range 0.25 to 2.5 A use SRW01-UMC1 or SRW-UMCT1 with two windings on the primary.
For further information, verify the User´s Manual.

Width (mm) Current (A) Power connection


66 12.5 - 125 Cable through UMC

SRW01-UMC4 SRW01-UMCT4

Width (mm) Current (A) Power connection


120 42 - 420 Bus bar

SRW01-UMC5 SRW01-UMCT5

Width (mm) Current (A) Power connection


265 84 - 840 Cable through or Bus bar

SRW01-UMC6 SRW01-UMCT6

For applications in higher currents, or that are out ot the UMC’s or UMCT’s range showed above, it is possible to use external current transformers (CT), supplied by
the user.

SRW01-CB Connection Cable


The cable SRW01-CB is responsable for the electric connection of the Control Unit SRW01-UC with the UMC or UMCT or EDU,
make capable the assembly detached until 2 meters and facilitate the installation.

Reference Length (mm)


SRW01-CB0 1) 60
SRW01-CB1 2) 120
SRW01-CB2 3) 500
SRW01-CB3 2000
SRW01-CB4 1000

Notes: 1) Cable for connect the Control Unit with the EDU.
2) Minimum cable for connect the Control Unit with the UMC/UMCT 1,2,3 and 4.
3) Minimum cable for connect the Control Unit with the UMC/UMCT 5 and 6.

10 SRW01
www.weg.net

Digital Expansion Unit - EDU


The digital expansion unit is used to add six digital inputs and four digital outputs in the Control Unit with the purpose of the control
systems that has more variables.

Reference Digital inputs External digital input supply voltage Digital outputs
SRW01-EDU1 6 24 V dc 4
SRW01-EDU2 6 110 V ac 4

Human Machine Interface - HMI


The HMI is connected in front of the relay through a communication cable, making configuration and operation practical and easier.

Reference Description
SRW01-HMI Human machine interface - HMI

Reference Description
SRW01-HMI2 Human machine interface - HMI (Horizontal Installation)

Earth Leakage Sensor (ELS)


The earth leakage sensor must be installed separately from the Control Unit (UC).
It can be installed in any position and connected on the Control Unit (UC) through a twisted pair and/or shielded cable, connected to
the sensor and S1 and S2 terminals, with maximum recomended distance of 10 m.

Reference Diameter (mm) UMC/UMCT compatible


SRW01-EL1 35 SRW01-UMC/UMCT 1, 2, 3
SRW01-EL2 70 SRW01-UMC/UMCT 4
SRW01-EL3 120 SRW01-UMC/UMCT 5
SRW01-EL4 210 SRW01-UMC/UMCT 6

It is recomended to use the equivalence relation between the Current Measuring Unit (UMC) or current and voltage measuring unit
(UMCT) and the ELS sensors for the instalation, as shown on the table above.

SRW01 11
www.weg.net

Connection Cable UC-HMI

Reference Length (mm)


SRW01-CH1 500
SRW01-CH2 1000
SRW01-CH3 1500
SRW01-CH4 2000

USB Communication Cable

Reference Length (mm)


SRW01-USB 2000

Communication Module

Reference Communication protocol


SRW01-MCD DeviceNet
SRW01-MCM Modbus
SRW01-MCP Profibus-DP

For part replacement or Control Unit (UC) without network module

Fixing Adaptor

Reference Description
PLMP Adaptor for screws fixing (2 pieces per package/0.006 kg)

Bus Bar for UMC and UMCT

Reference Description
JBL-RW407D Bus bar for Current Measuring Unit UMC6 and UMCT6

Protection Cover
Reference Description
SRW01-CDB 1) Plastic cover for DB9 protection
SRW01-CMU 1) Plastic cover for mini USB connector
SRW01-CBP 1) 2) Plastic cover for HMI connector / accessories

Connector DB9 Mini USB Notes: 1) 10 unit package


IHM 2) Plastic cover for old housing model (not the current rubber cover)
The protection covers are for spare part purpose, because the SRW01 is already delivered
with these accessories.

12 SRW01
www.weg.net

Operating Modes Diagrams


Power Cables

11 11
33 33

N
N N
L

K1
K1 K1
K1 K1
K1 K1
K1

L1
L1 L2
L2 L3
L3 L1
L1 L2
L2 L3
L3 L1 L2 L3
L1 L2 L3 L1
L1 L2
L2 L3
L3 L1
L1 L2
L2 L3
L3 L1 L2
L1 L2 L3
L3

T1
T1 T2
T2 T3
T3 T1
T1 T2
T2 T3
T3 T1
T1 T2
T2 T3
T3 T1
T1 T2
T2 T3
T3
SRW01-UMC
SRW01-UMC SRW01-UMCT
SRW01-UMCT SRW01-UMC SRW01-UMCT
SRW01-UMC SRW01-UMCT

M
M M
M M
M M
3 33 1
1 1
1

Three-phase and single-phase of the Current Measuring Unit (UMC) and Current/Voltage Measuring Unit (UMCT).

Connection of the Control Unit to the Expansion Digital Unit

110 ...240
110 ... 240 V ca/V
V AC/V dcHz50/60 Hz
DC 50/60
R/L1
R/L1 RL1
RL1

S/L2
S/L2 NN
T/L3
T/L3
Q1
Q1 Q2
Q2

> >

Q1
Q1 24
24 VVCCdc
S0
S0 S1
S1 S2
S2 K1
K1 K2
K2
S2
S2 S2
S2 S2
S2 S2
S2 S2
S2 S2
S2
> > >

S1
S1 S2
S2 I1
L1 I2
L2 I3
L3 I4
L4 IC
LC A1
A1 PE
PE I5
L5 I6
L6 I7
L7 I8
L8 I9
L9 I10
L10 EC
BC

SRW01-UC
SRW01-UC
SRW01-EDU
SRW01-EDU

SRW01-CB
SRW01-CB SRW01-CB
SRW01-CB

A2
A2 C1
C1 O1
O1 O2
O2 C3
C3 O3
O3 C4
C4 O4
O4 C5
C5 O5
O5 C6
C6 O6
O6 C7
C7 O7
O7 C8
C8 O8
O8

K1
k1 k2 K2

1
1 33 5
5 11 3
3 55
K1
K1 K2
K2
2
2 44 6
6 22 4
4 66

W2
W2 W1
W1

V2
V2 M
M V1
V1
33
V2
V2 V1
V1

Connection Diagrams of the Control Unit (UC) with the Digital Expansion Unit (EDU).

SRW01 13
www.weg.net

Direct Starter

R/L1

S/L2

T/L3

110 ... 240 V ac/V dc 50/60 Hz


Q1 R/L1

Q1 Q2

1 3 5
SO S1 K1
K1
2 4 6

S1 S2 I1 I2 I3 I4 IC A1

SRW01-UC
L1 L2 L3

SRW01-CB
SRW01-UMC

T1 T2 T3

S1 C1 01 02 C3 03 C4 O4

U V W K1
M
3

Connection diagrams for the Direct Starting Operation Mode using digital inputs at 24 V dc and driven by pushbuttons (P230 = 1). For further information consult the
SRW-01 User’s Manual.

Reversing Starter
R/L1

S/L2

T/L3

110 ... 240 V ac/V dc 50/60 Hz


Q1 R/L1

Q1 Q2

1 3 5 1 3 5
K1 K2
2 4 6 2 4 6 S0 S1 S2 K1 K2

S1 S2 I1 I2 I3 I4 IC A1

SRW01-UC
L1 L2 L3

SRW01-CB
SRW01-UMC

T1 T2 T3

A2 C1 O1 O2 C3 O3 C4 O4

U V W K1 K2
M
3

Connection diagram for the Reverter Starting Operation Mode using digital inputs at 24 V dc and driven by pushbuttons (P230 = 1). For further information consult the
SRW-01 User’s Manual.

14 SRW01
www.weg.net

Overload Relay
R/L1

S/L2

T/L3

110 ... 240 V ac/V dc 50/60 Hz


Q1 R/L1

Q1 Q2

1 3 5
S0 S1 S2 S3
K1
2 4 6

S1 S2 I1 I2 I3 I4 IC A1

SRW01-UC
L1 L2 L3

SRW01-CB
SRW01-UMC

A2 C1 O1 O2 C3 O3 C4 O4

A1
U V W
K1
A2
M
3

Connection diagram for the Overload Relay operation mode using digital inputs at 24 V dc.
For further information consult the SRW-01 User’s Manual.

Two Windings Starter

110 ... 240 V ac/V dc 50/60 Hz


R/L1 R/L1

S/L2 N

T/L3
Q1 Q1

Q1
S0 S1 S2 K1 K2

S1 S2 I1 I2 I3 I4 IC A1

SRW01-UC
L1 L2 L3

SRW01-UMC SRW01-CB

T1 T2 T3

A2 C1 O1 O2 C3 O3 C4 O4

K1 K2

1 3 5 1 3 5
K1 K2
2 4 6 2 4 6

W2 W1

V2 M V1
3
V2 V1

Connection diagram for the Two Windings Starting Operation Mode using digital inputs at 24 V dc and driven by pushbuttons (P230=1).
For further information consult the SRW-01 User’s Manual.

SRW01 15
www.weg.net

Star-Delta Starter
R/L1

S/L2

T/L3

110 ... 240 V ac/V dc 50/60 Hz


Q1 R/L1

Q1 Q2

1 3 5 1 3 5 1 3 5 K1
K1 K2 K3
S0 S1
2 4 6 2 4 6 2 4 6
K2 K3

S1 S2 I1 I2 I3 l4 lC A1

SRW01-UC
L1 L2 L3

SRW01-CB
SRW01-UMC

T1 T2 T3

1 5 A1 C1 O1 O2 C3 O3 C4 O4

2 M 4
3
3 6 K1 K2 K3

Connection diagram for the Star-Delta Starting Operation Mode - using digital inputs at 24 V dc and driven by pushbuttons (P230=1) and measuring of delta current.
For further information consult the SRW-01 User’s Manual.

Transparent Mode

The transparent mode allows the user to develop its own application using the WLP software ladder language.

R/L1

S/L2

T/L3

110 ... 240 V ac/V dc 50/60 Hz


Q1 R/L1

Q1 Q2

S0

1 3 5
S0 K1
K1
2 4 6

S1 S2 I1 I2 I3 I4 IC A1

SRW01-UC
L1 L2 L3

SRW01-CB
SRW01-UMC

T1 T2 T3

A2 C1 O1 O2 C3 O3 C4 O4

A1
U V W K1
A2
M
3

Connection diagram for the Transparent Operation Mode using digital inputs at 24 V dc.
For further information consult the SRW-01 User’s Manual.

16 SRW01
www.weg.net

WLP Software
The WLP is the SRW01 configuration software for Windows The LADDER program has a 64 kbytes memory and can use
environment with user friendly interface that enables system the relay digital inputs and outputs.
parametrization, programming, controlling and monitoring. Communication between software and relay can be
The WLP software enables the user to configure the relay, performed through USB port or Modbus network.
edit parameters and program in LADDER. The WLP software is free and supplied with the product.
Through the WLP configuration assistants the user has a It can be also obtained from the website www.weg.net.
guided routine that enables relay configuration. When
necessary, the relay can be programmed in LADDER using
mathematical and control blocks.

Configuration Assistants
These routines have been especially created to assist relay configuration. They help the user to configure the relay in an easy self
explanatory manner.
g Configuration Assistant: Control Configuration

Monitoring Dialogues
These dialogues have been especially created to monitor the relay.
They monitor exclusive relay information.
g Monitoring dialogues: Diagnostic

SRW01 17
www.weg.net

Technical Characteristics
Mounting position Any
Pollution degree 2
- Control Unit (UC): IP20
- Current Measuring Unit (UMC):
- Without bus bar: IP20
- With bus bar: IP00
- Current and voltage measuring unit (UMCT):
Protection degree (IEC 60529)
- Without bus bar: IP20
- With bus bar: IP00
General data - Digital expansion unit (EDU): IP20
- Human machine interface (HMI): IP54
- Earth leakage sensor (ELS): IP20
- Operation: According IEC: 0...+55 ºC
Allowed ambient temperature According UL: 0...+40 °C
- Storage and transport: -25...+80 °C
Control Unit (UC): 200,000 A
Short-circuit ratings (UL)1)
Current Measuring Unit (UMC) and Current/voltage Measuring Unit (UMCT): 200,000 A
- Control Unit (UC): classes 10/20/30
Tripping class (UL)
- Current Measuring Unit (UMC): classes 10/20/30
Isolation rated voltage Ui 300 V
Supply rated voltage 110 - 240 V ac/V dc @ 50/60 Hz 24 V ac/V dc @ 50/60 Hz
Operation range 0.85 Us - 1.10 Us 0.80 Us - 1.20 Us
Consumption (typical) 2) 6W 5W
Number of digital inputs 4 opticaly isolated inputs (24 V dc or 240 V ac)
Digital inputs supply 24 V dc 110 V ac
Internal 24 V dc isolated power source or
Digital inputs power source External 110 V ac power
external
Digital inputs current 11 mA @ 24 V dc 5 mA @ 110 V ac
Digital inputs isolation 3 kV
Number of digital outputs 4 relay outputs
- 2 SPST outputs
Contacts grouping
- 2 common shared SPST outputs
Maximum operation voltage 250 V dc, 240 V ac
Smallest operation power 1 W or 1 VA
Control Unit (UC)
- UL 508: C300, R300
- AC-15 (IEC 60947-5-1): 1.5 A ac / 120 V ac
Switching capacity per relay contacts 0.75 A ac / 240 V ac
- DC-13 (IEC 60947-5-1): 0.22 A dc / 125 V dc
0.1 A dc / 250 V dc
Contacts capacity (resistive load) 3 A, 30 V dc / 250 V ac
External protection against short-circuit 6 A gL/gG fuse
- TRIP value: > 3.4 kΩ
Motor protection VIA - PTC
- Rearm value: < 1.6 kΩ
- Torque: 0.5 Nm - 4.5 lb.in
- Conductors section:
Terminals (conectors) - Rigid and bare: 1 x (0.2 ... 2.5 mm2); 1 x (2 ... 12 AWG)
- Flexible with/without terminals: 1x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)
- Screws: M3
- Error or fault reset - system
Reset button - TRIP or alarm reset - protections
- TRIP test

Note: 1) Consult the user’s manual;


2) Considering the Control Unit (UC) and Current Measuring Unit (UMC) or current/voltage measuring unit (UMCT) consumption.

18 SRW01
www.weg.net

Current range 0.25 - 840 A ac


Isolation degree Ui 690 V ac
- IEC 60947-4-1: 690 V ac
Rated operational voltage Ue
- UL 508: 600 V ac
Impulse voltage Uimp 6 kV
Current Measuring Unit (UMC)
Frequency range 50/60 Hz
Application Three-phase, single-phase
- UMC 1, 2 and 3: 8 mm
- UMC 4: 15 mm
Cable hole diameter
- UMC 5: bus bar
- UMC 6: 32 mm or bus bar
Current range 0.25 - 840 A ac
Voltage range 35 - 690 V ac
Isolation degree Ui 690 V ac
IEC 60947-4-1: 690 V ac
Rated operational voltage - Ue
UL 508: 600 V ac
Impulse voltage Uimp 6 kV
Frequency range 50/60 Hz
Current and Voltage Measuring Unit Application Three-phase, single-phase
(UMCT) UMCT 1, 2 y 3: 8 mm
UMCT 4: 15 mm
Cable hole diameter
UMCT 5: bus bar
UMCT 6: 32 mm or bus bar
- Torque tightening: 0.5 Nm - 4.5 lb.in
- Maximum conductos section:
Terminals (connectors) - Rigid and bare: 1 x (0,2 ... 2.5 mm2); 1 x (26 ... 12 AWG)
- Flexible with/without terminals: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)
- Screws: M3
Current range 0.3 - 5 A ac
Isolation degree Ui 690 V ac
- IEC 60947-4-1: 690 V ac
Rated operation voltage
- UL 508: 600 V ac
Impulse voltage Uimp 6 kV
Frequency range 50/60 Hz
Application Monophasic and triphasic
Earth Leakage Sensor (ELS) - EL1: 35 mm
- EL1: 70 mm
Window internal diameter
- EL1: 120 mm
- EL1: 210 mm
- Torque: 0.29 Nm - 2.6 lb.in
- Maximum conductos section:
Terminals (conectors) - Rigid and bare: 1 x (0.2 ... 2.5 mm²); 1 x (22 ... 14 AWG)
- lexible with/without terminals: 1 x (0.2 ... 1.5 mm²); 1 x (22 ... 14 AWG)
- Screws: M3
Rated isolation voltage Ui 300 V
Number of digital inputs 6 optically isolated inputs (24 V dc or 110 V ac)
Digital inputs supply 24 V dc 110 V ac
Digital inputs power source External 24 V dc power source External 110 V ac power source
Digital inputs current 11 mA @ 24 V dc 5 mA @ 110 V ac
Digital inputs isolation 3 kV
Number of digital outputs 4 relay outputs
Contacts grouping 4 SPST outputs
Maximum operation voltage 250 V dc, 240 V ac
Smallest operation power 1 W or 1 VA
Digital Expansion Unit (EDU)
- UL 508: C300, R300
- AC-15 (IEC 60947-5-1): 1.5 A ac / 120 V ac
Switching capacity per relay contact 0.75 A ac / 240 V ac
- DC-13 (IEC 60947-5-1): 0.22 A dc / 125 V dc
0.1 A dc / 250 V dc
Contacts capacity (resistive load) 3 A, 30 V dc / 250 V ac
Short-circuit external capacity 6 A gl/gG fuse
- Torque: 0.5 Nm - 4.5 lb.in
- Conductors section:
Terminals (conectors) -Rigid and bare: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)
-Flexible with/without terminals: 1 x (0.2 ... 2.5 mm2); 1 x (26 ... 12 AWG)
- Screws: M3

SRW01 19
www.weg.net

71,2
104

100
Dimensions (mm)

13.5
Control Unit - SRW01-UC 45
Digital Expansion Unit - EDU
127
127 45
45
71,2
71,2
104
100
104

100

104
104
13,5
13.5

45
45 3,7
3.7 118,2
118.2 5,14.69

Human Machine Interface - HMI Human Machine Interface (Horizontal) - HMI


58
50
36,5

36,5
58
16 98
91,1
101

98

18 101
3.7 118.2 4.69
50
18

16

91,1

Current Measuring Unit - SRW01 - UMC


11 11
94,2
90
84
80

66 68
54,3
45 3,7 74,9
3,7 59,3

Ø15
Ø8

SRW01-UMC1/UMC2/UMC3 SRW01-UMC4

45 45
25
110

127
130
155

84

40 49,5
M10

76,3
120 152

Ø8

45

SRW01-UMC5

20 SRW01
www.weg.net

Current Measuring Unit - SRW01 - UMC


81 81
32

84
150
120

84
70

Ø5

50
50

70
250,5 90
265 167
250,5
50,3
265 81 81
90
Ø32
81 81 167
Ø32

45,5
45,5

Ø8
Ø8

sin barramiento
45 69

45 69

SRW01-UMC6 SRW01-UMC6
(without bus bar) (with bus bar)

Current and Voltage Measuring Unit - UMCT

11
80
84

45
3,7
54,3
Ø8 59,3

SRW01-UMCT1 - UMCT2 - UMCT3

SRW01 21
www.weg.net

Current and Voltage Measuring


11 Unit - UMCT 45 45
25

11
11 45 45
25
94,2

155
130

110
94

84
127
11 45 45
94,2
90

25

155
130
155

110
94

110

84
127

84
94

127
66 68 49,5
3,7
94,2

M10
40 76,5

155
130

110
94

84
94

127
66 68 120 49,5
3,7
3,7 49,5

M10
97 40 76,3
76,5 167
94
94
Ø 15 120
120 171
66 68 97 49,5 167
3,7

M10
Ø15 40 76,5
Ø 1594 171
171
120
97 167
Ø 15 171
Ø8

Ø8
Ø8

Ø8

SRW01-UMCT4 45 SRW01-UMCT5
UMCT 4 (mm) UMCT
45 5 (mm)
45
UMCT 4 (mm) UMCT 5 (mm)
UMCT 5 (mm)
UMCT 4 (mm)
81
81 81
81
32
32
81 81 81 81
32 32
84,46
50 70
50 50

84,46

84,46
84,46
84,46
70

70

120
50
70
70
7050

120
50
84,46

150
150
84,46
Ø5 Ø5
70

120

Ø5 Ø5
50

150

Ø5

84,46
Ø5
70

120
50

150
250,5 Ø5
250,5
250,5 91
91 91 Ø5

M12
M12
265 250,5 181,9
181,90 M12
265 265 91 181,90 250,5
81 81 Ø34 250,5
250,5

M12
81 81 Ø 34 50,3
81 81 Ø 34 185,5
185,5
185,5
181,90
50,3
50,3
265 265
250,5 265
265
91
81 81 Ø 34 81 81 Ø 34 181,9 50,3
91
45,5

185,5 91
45,5

81
81
265 81
81
185,5 Ø34
Ø 34 181,9
181,9
45,5

45,5

91
81 81 Ø 34 181,9 185,5
185,5
45,5

45,5
45,5 185,5
45,5

Ø8
Ø8
Ø8

Ø8
Ø8
Ø8 Ø8
Ø8 45 70

45
45 70
70
SRW01-UMCT6 - without bus bars SRW01-UMCT6 - with bus bars
UMCT 6 – Sem barramento (mm)
UMCT 6 – Com barramento (mm) 45
45 70
70
8 45 70
Earth Leakage Sensors
45
45
(ELS)
70
70 X1
UMCT 6 – Com barramento (mm)
UMCT X2
64 66––Sem
Sem barramento (mm) UMCT 6 – Com barramento (mm)
8 8
UMCT barramento (mm)
36
D2
D1
20
40

5 4

D1
5 4 Detail 1
EL2 and EL3
20
H

Detail 1
EL4
74

35

W D2

64 40 Detail 1
SRW01-EL1 SRW01-EL2 / EL3 / EL4

Model ∅ H W X1 X2 D1 D2
EL2 70 116 104 64 36 20 40
EL3 120 169 154 94 66 20 40
EL4 210 304 290 150 110 33 90 *

* with base metallic support

22 SRW01
www.weg.net

The Global Solution With Electric Machines and Automation for Industry
and Energy Systems.

WEG, one of the largest global manufacturers of Electric Motors with Quality and Efficiency recognized
in different industrial areas worldwide, is also present in Energy, Transmission and Distribution, Coatings
and Industrial Automation sectors, and produces and offers a wide range of electric components for
Motor Control and Protection and Electric Circuit Protection.

Motor Protection and Starters Pushbuttons and Pilot Lights


g Modular Contactors up to 800 A (AC-3) g IP66 pushbuttons and pilot lights

g Compact Contactors up to 22 A (AC-3) g 


Flush, Guarded, Extended or Mushroom illuminated or
g Control relays non illuminated pushbuttons
g Motor Protective Circuit Breakers up to 100 A Selector switches Lever or Knob illuminated or non
g 

Enclosed Starters (plastic or metallic enclosures)


g  illuminated or with key
g Customized starters for OEM applications g Emergency pushbuttons (according EN418)

g Overload relays g Contact blocks with “Positive Break” system

g Double pushbutton

Electrical Circuit Protection g Pilot Lights with LED technology

g Miniature Circuit Breakers up to 100 A g Customized descriptions

g Molded Case Circuit Breakers up to 1600 A

g Air Circuit Breakers up to 6300 A Electronic Relays


g D and NH gL-gG fuses g Timing, Monitoring, Protection and Level Relays

g NH aR fuses (for semiconductor protection) g 22.5 mm width frame

g Switch-disconnector MSW up to 160 A g LED for status indication

g Fuse-switch-disconnector FSW up to 630 A

Smart Relay
Electrical Connections g Low voltage electric motor management system

g Terminal blocks with screw type connection g Compact and Modular concept

g Terminal block with spring type connection Full motor protection and monitoring through Current
g 

g Terminal blocks for fuses and Voltage measurings


g Busbar and busbar connectors g Multiple operating modes including PLC functions

g Identifiers for terminals and cables Easy network module change via exclusive drawer
g 

g Printing system system (Modbus, DeviceNet, Profibus modules)


g USB communication

Capacitors g Free WLP programming software

g Power Factor Compensation

g Lighting

g Motor-run

SRW01 23
WEG Worldwide Operations
ARGENTINA COLOMBIA MEXICO SINGAPORE
WEG EQUIPAMIENTOS WEG COLOMBIA WEG MEXICO WEG SINGAPORE
ELECTRICOS Bogotá Huehuetoca Singapore
San Francisco - Cordoba Phone: +57 1 416 0166 Phone: +52 55 5321 4231 Phone: +65 68589081
Phone: +54 3564 421 484 [email protected] [email protected] [email protected]
[email protected] www.weg.net/co www.weg.net/mx www.weg.net/sg
www.weg.net/ar
FRANCE VOLTRAN - WEG Group SCANDINAVIA
WEG PINTURAS - Pulverlux WEG FRANCE Tizayuca - Hidalgo WEG SCANDINAVIA
Buenos Aires Saint Quentin Fallavier - Lyon Phone: +52 77 5350 9354 Kungsbacka - Sweden
Phone: +54 11 4299 8000 Phone: +33 4 74 99 11 35 www.voltran.com.mx Phone: +46 300 73 400
[email protected] [email protected] [email protected]
www.weg.net/fr NETHERLANDS www.weg.net/se
AUSTRALIA WEG NETHERLANDS
WEG AUSTRALIA GERMANY Oldenzaal - Overijssel UK
Victoria WEG GERMANY Phone: +31 541 571 080 WEG ELECTRIC MOTORS U.K.
Phone: +61 3 9765 4600 Kerpen - North Rhine Westphalia [email protected] Worcestershire - England
[email protected] Phone: +49 2237 9291 0 www.weg.net/nl Phone: +44 1527 596 748
www.weg.net/au [email protected] [email protected]
www.weg.net/de PERU www.weg.net/uk
AUSTRIA WEG PERU
WATT DRIVE - WEG Group GHANA Lima UNITED ARAB EMIRATES
Markt Piesting - Viena ZEST ELECTRIC GHANA Phone: +51 1 472 3204 WEG MIDDLE EAST
Phone: +43 2633 404 0 WEG Group [email protected] Dubai
[email protected] Accra www.weg.net/pe Phone: +971 4 813 0800
www.wattdrive.com Phone: +233 30 27 664 90 [email protected]
[email protected] PORTUGAL www.weg.net/ae
BELGIUM www.zestghana.com.gh WEG EURO
WEG BENELUX Maia - Porto USA
Nivelles - Belgium INDIA Phone: +351 22 9477705 WEG ELECTRIC
Phone: +32 67 88 84 20 WEG Electric India [email protected] Duluth - Georgia
[email protected] Bangalore - Karnataka www.weg.net/pt Phone: +1 678 249 2000
www.weg.net/be Phone: +91 80 4128 2007 [email protected]
[email protected] RUSSIA www.weg.net/us
BRAZIL www.weg.net/in WEG RUSSIA
WEG EQUIPAMENTOS ELÉTRICOS Saint Petersburg ELECTRIC MACHINERY
Jaraguá do Sul - Santa Catarina WEG INDUSTRIES INDIA Phone: +7 812 363 2172 WEG Group
Phone: +55 47 3276-4002 Hosur - Tamil Nadu [email protected] Minneapolis - Minnesota
[email protected] Phone: +91 4344 301 501 www.weg.net/ru Phone: +1 612 378 8000
www.weg.net/br [email protected] www.electricmachinery.com
www.weg.net/in SOUTH AFRICA
CHILE ZEST ELECTRIC MOTORS VENEZUELA
WEG CHILE ITALY WEG Group WEG INDUSTRIAS VENEZUELA
Santiago WEG ITALIA Johannesburg Valencia - Carabobo
Phone: +56 2 784 8900 Cinisello Balsamo - Milano Phone: +27 11 723 6000 Phone: +58 241 821 0582
[email protected] Phone: +39 02 6129 3535 [email protected] [email protected]
www.weg.net/cl [email protected] www.zest.co.za www.weg.net/ve
www.weg.net/it
CHINA SPAIN
WEG NANTONG JAPAN WEG IBERIA
Nantong - Jiangsu WEG ELECTRIC MOTORS Madrid
Phone: +86 0513 8598 9333 JAPAN Phone: +34 91 655 30 08
[email protected] Yokohama City - Kanagawa [email protected]
www.weg.net/cn Phone: +81 45 550 3030 www.weg.net/es
[email protected]
www.weg.net/jp
The values shown are subject to change without prior notice.

For those countries where there is not a WEG own operation, find our local distributor at www.weg.net.
Cod: 50022690 | Rev: 04 | Date (m/y): 02/2013

Grupo WEG - Automation Business Unit


Jaraguá do Sul - SC - Brazil
Phone: +55 47 3276 4000
[email protected]
www.weg.net