0% found this document useful (0 votes)
41 views4 pages

Hamilton Bathtub Install Guide Drop in

The document provides instructions for installing a drop-in bathtub. It lists necessary tools and safety precautions. It describes how to inspect the tub, prepare the site, install drain pipes and faucets, test for leaks, and care for the tub.

Uploaded by

decnavx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views4 pages

Hamilton Bathtub Install Guide Drop in

The document provides instructions for installing a drop-in bathtub. It lists necessary tools and safety precautions. It describes how to inspect the tub, prepare the site, install drain pipes and faucets, test for leaks, and care for the tub.

Uploaded by

decnavx
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Drop-In Bathtub

Installation Instructions
gelcoat & solid surface bathtubs

Tools you might need for proper installation

• Galvanized Nails or Screws • Shims


• Large Level • Adhesive
• Hammer or Screw Gun

Thank you for purchasing Praxis Bathware. For best results, a No. 8 solid copper bonding conductor between this unit
please read and follow all directions carefully. and all other electrical equipment and exposed metal in the
vicinity, as needed to comply with local requirements.
PRE-INSTALLATION PLANNING
PRECAUTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRICAL SHOCK OR INJURY TO PERSONS. READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

WARNING- When using this unit, basic precautions should Inspection: Upon receipt of the Whirlpool Bath, inspect
always be followed, including the following: it thoroughly for damage or shortage. Verify that the
unit specifications are correct. If damage or shortage has
1. READ AND FOLLOW ALL INSTRUCTIONS. occurred notify the distributor or freight carrier immediately.

2. DANGER: To reduce the risk of injury, do not permit Under no circumstances should a damaged or defective
children to use this unit unless the are closely supervised at unit be installed without prior factory approval. Neither
all times. Praxis Companies nor the distributor will be responsible for
removal or re-installation costs should replacement of the
3. Use this unit for its intended use as described in this unit be necessary.
manual. Do not use attachments not recommended by
manufacturer. Testing: Follow all testing procedures. While each unit is
factory water tested, the shipping process may result in
4. Never drop or insert any object into any opening. damage to, or loosening of the pipe joints and connections.

5. Do not operate unit without guard over suction fitting. Keep the unit covered during and after installation to
prevent damage to the surface of the bath.
6. The unit must be connected only to a supply circuit that
is protected by a ground-fault circuit interrupter (GFCI). Do not lift the unit by the piping. Lift only by the bath’s deck.
Such a GFCI should be provided by the installer and should
be tested on a routine basis. To test the GFCI, push the Never attempt to run the pump/motor while the whirlpool
test button. The GFCI should interrupt power. Push the is dry.
reset button. Power should be restored. If the GFCI fails to
operate in this manner, the GFCI is defective. If the GFCI Be sure the installation follows all applicable codes.
disrupts power to the bath without the test button being
pushed a ground current is flowing indicating the risk of Service and repairs should be performed only by qualified
electrical shock. Do not use this hydro-massage bathtub. service representatives.
Disconnect the hydro-massage bathtub and have the
problem corrected by a qualified service representative
before using.

7. A grounding lug is provided on the exterior of the control


panel (where applicable) and pump to permit connection of
Drop-In Bathtub
Installation Instructions
gelcoat & solid surface bathtubs

INSTALLATION PROCEDURE BATH”S WEIGHT (See diagram #1 below). If a screw


flange is provided, see flange instructions.
WARNING - When using electrical products, basic
precautions should always be followed, including the
following:

DANGER: RISK OF ELECTRICAL SHOCK. Connect only


to a circuit protected by a Ground Fault Circuit Interrupter
(GFCI).

This unit should be installed by a qualified service


representative.

INSTALL TO PERMIT ACCESS FOR SERVICING: A


minimum access panel of 15” x 20” must be provided should
the pump or other equipment need service at a later date.

Inspect the unit carefully to ensure there is no damage or


defects present. Be sure the unit is correct size, color and has
all features originally ordered.

TESTING: Water test the unit prior to installation. Set it up


where it can be drained after testing. Plug the drain hole
and fill to the overflow. Make sure all fittings, thru-walls
and piping are water tight. If leaks are present, contact the
distributor or Praxis Customer Service Department.

DO NOT INSTALL THE BATH.


DECK INSTALLATION: For deck mounted tubs, use the
ROUGH IN: Rough in should be kept to a minimum until dimension of the unit and subtract 1-1/2 inches to reach
the unit is on the job site. Measurements may vary plus or your platform opening dimensions. e.g. Tub dimensions are
minus 1/4 inch from original specifications. 72” x 36”. Platform opening will be: 70-1/2” x 34-1/2”. (See
diagram #2).
CHECKING LEVEL: Place the unit in the location of
installation. Using a 5 or 6 foot level, check level (length and
width) to determine if the floor is level. If it is not, calculate
how much mortar you will have to use to level the tub. Pour
a small amount of water onto the deck of the tub. Check
that the water drains from the deck into the interior of the
tub.

WALL INSTALLATION: When the unit is to be placed


against a wall, blocking should be attached to the wall in such
a way as to allow the tub lip to rest on the blocking.

DO NOT ALLOW TUB LIP TO SUPPORT ANY OF THE


Drop-In Bathtub
Installation Instructions
gelcoat & solid surface bathtubs

FAUCET AND VALVES: Faucet and valves may be installed


through the tub deck. Use a sharp hole saw, making sure
the spout will clear the deck edge before drilling. A heat
resistant material must be placed between the tub and any
soldering work to prevent damage to the tub.

FINISHING: Before closing in the unit fill the tub 2” above


the highest jet. Run the pump for 15 minutes and check for
leaks. Shut off the pump, let stand for 5 minutes and check
again for leaks. When draining the bath, check tub’s base for
proper drainage.

NOTE: The tub must be cleaned before operating the pump.

NEVER OPERATE THE PUMP WITHOUT THE SUCTION


COVER IN PLACE.

After the unit has been tested, close in with the material of
your choice. Seal around the tub lip
and surrounding walls (where applicable) with a water IN-LINE HEATER (OPTIONAL) SPECIFICATIONS: 1.5
resistant sealer. KW, 115/120 VOLT, 12.4 AMP. The In-Line Heater must be
connected to a 115/120 VAC, 20 AMP, dedicated circuit
Clean out the unit using a damp cloth and liquid detergent. protected with a GFCI (Ground Fault Circuit Interrupter).
do not use solvents or abrasive cleaners. Install an outlet to the studwall. The outlet must be a
minimum of 6 inches above the floor and must be located
near the access panel.
Fill tub and test operation.
Note: Where applicable grounding lugs are provided on the
ELECTRICAL CONNECTIONS ALL WIRING MUST BE exterior of the pump, in-line heater and control box to permit
DONE BY A QUALIFIED, LICENSED ELECTRICIAN connection of a No. 8 solid copper bonding conductor between
this unit and all other electrical equipment and exposed metal
BATH PUMP SPECIFICATIONS: 115/120 VAC 6.6 AMP in the vicinity, as needed to comply with local requirements.
60 HZ -OR- 115/120 VAC 10.6 AMP 60 HZ, requires a
dedicated circuit protected with a 15 AMP GFCI (Ground
Fault Circuit Interrupter). See Diagram #3. CARE AND CLEANING
Do not use caustic or abrasive cleaners on the unit. Avoid
For units equipped with luxury upgrades: 115/120 VOLT, harsh abrasive or gritty scouring powders. To clean the unit,
11.2 AMP, 60 HZ. requires a dedicated circuit protected simply use a household liquid detergent with a soft sponge
with a 20 amp GFCI (Ground Fault Circuit Interrupter). See or cloth and warm water. More persistent stains,tar, or
Diagram #4. paint can be removed with mineral spirits. Remove excess
plaster by scraping with a sharpened soft wood stick. Avoid
For all installations, install an outlet to the stud wall a wire brushes, metal scrapers or tools. Restore dull areas by
minimum of 6 inches above the floor, located near the rubbing with an automotive type body cleaning compound.
pump access opening.
Drop-In Bathtub
Installation Instructions
gelcoat & solid surface bathtubs

LIMITED WARRANTY
Praxis Companies, LLC warrants to the owner of its
bathtubs units as follows: Units manufactured of fiberglass
reinforced polyester resin, that it will, free of charge, repair
or exchange as its option, any Praxis Companies, LLC
unit found to be defective in materials or workmanship
upon inspection by an authorized representative of Praxis
Companies, LLC for a period of three (3) years from date
of purchase for gelcoat units and a period of ten (10) years
from date of purchase for solid surface units . The exchange
of a unit is limited to supplying a replacement unit of
comparable size and style and does not include any costs
of removal or installation. This warranty shall be voided if
the unit is moved from its place of initial installation or is
not installed in accordance with the instructions supplied
by the manufacturer of the unit. Further, this warranty
does not apply if the unit has been subjected to accident,
abuse, misuse, damage caused by flood, fire or act of God.
Since local code requirements vary greatly throughout the
country, distributors, dealers, installation contractors and
users of plumbing products should determine whether
there are any code restrictions on the use of a specific
product. Praxis Companies, LLC makes no representation
or warranty regarding and shall not be responsible for any
code compliance. The owner agrees by use of this unit that
the obligations of Praxis Companies, LLC shall not exceed
to contingent or indirect damage or injury to the structure
of its contents, that the obligations of Praxis Companies,
LLC are limited to those set forth herein, and that no other
obligations, expressed or implied, are assumed by Praxis
Companies, LLC.

©
2014, The Praxis Companies, LLC
435 Industrial Rd., Savannah, TN 38372
Customer Service: 800.443.7269
www.praxiscompanies.com

© 2014, The Praxis Companies, LLC PRADROPIN/012014/6MAN130

You might also like