GF UD2100 Ultrasonic Doppler Flowmeter
Features
• Large, easy to read graphic display
with backlighting
• Easy to install without special tools
• "Clamp-On" design
• Made for difficult applications and dirty media
• Compatible with almost all pipe types
and diameters
• Simple quick-start set up procedure
• Compact integral design
The GF UD2100 ultrasonic doppler flowmeter is a • Various options for process communication
permanent clamp-on flowmeter for non-invasive
• Integrated datalogger
flow measurement.
It is specifically designed for challenging flow
applications with dirty, aerated, abrasive, corrosive
and/or caustic media – applications where the
FM
most regular flowmeters would be defeated.
APPROVED
Typical media in applications of the GF UD2100
contains: Wastewater, slurries, vicious liquids, Applications
sewage, abrasives, sediments and others. The
flowmeter is recommend for use in fully filled • Wastewater Treatment
pipes and virtually any media that contains solids • Mining
or bubbles. • Paper Mills
• Monitoring of manufacturing processes with
The GF UD2100 can be used on UPVC, CPVC, PE, dirty liquids
PVDF, PP-H, ABS, PB, HDPE, steel and iron pipes.
Processes can be monitored directly by a higher-
level system via 4-20 mA, HART or Modbus output. Recommended for use with liquids containing
suspended solids or bubbles with minimum size
of 100 microns and minimum concentration of
75 ppm.
Specifications
General
Measuring Method Ultrasonic doppler measurement
Flow Range ± 0.1 m/s to 12.2 m/s (± 0.3 ft/s to 40 ft/s), bi-directional
Accuracy ± 2 % of measured value at flow rate > ± 0.3 m/s
Requires solids or bubbles with minimum size of 100 microns and minimum concentration of
75 ppm
Repeatability ± 0.5 % of measured value
Linearity ± 0.5 %
Response Time 1s
Selectable Flow Units Velocity m/sec, ft/sec.
Volume Liter (L) per sec/min/hour/day
US gallons (USG) per sec/min/hour/day
Imperial gallons (ISG) per sec/min/hour/day
Barrels (bbl) per sec/min/hour/day
Cubic meter (m3) per sec/min/hour/day
Cubic feet (m3 ) per sec/min/hour/day
Selectable Totalizer Units Liters, m3, US gallons, imperial gallons, barrels, cubic feet
Menu Languages English, Spanish, French
Environmental
Operating Temperature -20 °C to +60 °C (head unit) -4 °F to +140 °F
-40 °C to +150 °C (sensor) -40 °F to +300 °F
Storage Temperature -10 °C to +60 °C 14 °F to 140 °F
Pipe Wall Temperature 0 °C to 85 °C 32 °F to 185 °F
Operating Humidity Max. 90 % relative humidity at +50 °C (122 °F)
Suitable Pipe Types
Pipe Materials UPVC, CPVC, PE, PVDF, PP-H, ABS, PB, HDPE, steel, stainless steel, iron, cast iron, ductile iron,
metal, line pipes.
Pipes with loose insertion liners and pipes with walls containing air are not supported
Pipe Diameter (OD) 16mm to 4500 mm* ½ inch to 180 inch*
Electronics
Power Supply 100 to 240 V AC (50 Hz to 60 Hz)
9 to 32 V DC
Power Consumption AC: Max. 10 VA
DC: Max 10 Watt
Outputs
Analog Output Range 4 to 20 mA or 0 to 5 VDC
Resolution 0.1 % of measurement range
Load max. 1000 Ω
Isolation 1500 V optically isolated
Alarm Current 3.5 mA
Pulse Output Pulse Sequence 2.25 s minimum time between pulses
Pulse Duration 350 ms
Max. Voltage 250 VAC
Max. Current 12 A
Isolation 1000V
Modbus Type Modbus RTU via RS485 or HART
Relays Type 2x SPDT 5 amp
Programming Programmable flow alarm and/or proportional pulse
Data Interface USB
Data points 26 million
Format CSV
Housing and Display
Enclosure Material Polycarbonate
Dimensions 278 x 188 x 130 mm 10.95 x 7.4 x 5.12 inch
Weight 5 kg 11 lbs
Keyboard Keypad with 5 buttons
Protection class IP 66 / NEMA4X (water and dust tight)
Display Type White, backlit LCD-Matrix
Supported Languages English, Spanish, French
Sensor Material 316SS
Dimensions 85 x35 x 38 mm 3.375 x 1.375 x 1.5 inch
www.gfps.com
Specifications (cont.)
Shipping Information
Packaging Dimensions 380 x 290 x 230 mm 15 x 12 x 10 inch
Weight 5,4 kg 12 lbs
Volume Weight 5,4 kg 12 lbs
Standards and Approvals
CE, conforms to RoHS
Security EN 61010-1:2020
EMV EN 61326-1:2013 EN 61326-2-3:2013
Environment EN 60068-1:2015
EN 60068-2-1:2008 EN 60068-2-2:2008
* Measurable pipe sizes are dependent on pipe material and inner pipe diameter.
Packaging Content
1 1. GF UD2100 head-unit
2. GF UD2100 Doppler Sensor incl. cable
3. S/steel hose-clip
4. S/steel sensor pipe clamp
5. Superlube coupling grease (12 g)
6. Cable ties
7. GF calibration certificate
8. Enclosure mounting hardware
9. USB-Stick incl. product documentation &factory
7 calibration certificate
2
3
4
5
8
6
9
www.gfps.com
Dimensions
Function
The GF UD2100 ultrasonic doppler flowmeter
continuously emits high frequency (ultrasonic) sound
pulses through the pipe wall into the flowing liquid.
The ultrasonic sound pulses get reflected back from
the particles or gas bubbles in the media. At zero flow
the reflected frequency is the same as the emitted
frequency. If the liquid is flowing the reflected frequency
is different from the emitted (through the doppler effect).
This frequency shift is measured continuously by the
GF UD2100 and used to precisely measure the velocity
of the media.
www.gfps.com
Configuration Options
Type Configuration Code Configuration Option
UD2100 -꙱꙱-꙱꙱-꙱꙱-꙱꙱-꙱ Standard Model (A1-A1-A1-A1-A)
Power Input
UD2100 -A꙱-꙱꙱-꙱꙱-꙱꙱-꙱ Standard – 100 to 240VAC 50/60Hz
UD2100 -B꙱-꙱꙱-꙱꙱-꙱꙱-꙱ 9 to 32VDC, 10W Maximum
Enclosure & Electronics Potection
UD2100 -꙱1-꙱꙱-꙱꙱-꙱꙱-꙱ Standard – NEMA4X (IP66) polycarbonate
Enclosure Temperature Rating
UD2100 -꙱꙱-A꙱-꙱꙱-꙱꙱-꙱ Standard – (-5° to 140°F / -20° to 60°C)
Intrinsic Safety
UD2100 -꙱꙱-꙱1-꙱꙱-꙱꙱-꙱ Standard – SE4 Transducer, Non-Incendive for
Class 1 Div 2, Groups A,B,C,D
Transducers
UD2100 -꙱꙱-꙱꙱-A꙱-꙱꙱-꙱ Standard – SE4-A Clamp-on Sensor (for 0.5” / 12.5
mm to 180” (4.5 m) ID pipes
Transducers Mounting Hardware
UD2100 -꙱꙱-꙱꙱-꙱1-꙱꙱-꙱ Standard – PC4; Includes stainless bracket,
mounting clamps, and silicone coupling compound
Transducer Cable Length
UD2100 -꙱꙱-꙱꙱-꙱꙱-A꙱-꙱ Standard – 25 ft. (7.6 m) shielded coaxial pair
-꙱꙱-꙱꙱-꙱꙱-B꙱-꙱ 50 ft / 15 m continuous shielded coaxial pair
-꙱꙱-꙱꙱-꙱꙱-C꙱-꙱ 100 ft / 30 m continuous shielded coaxial pair
Serial Communication
UD2100 -꙱꙱-꙱꙱-꙱꙱-꙱1-꙱ Standard – None
-꙱꙱-꙱꙱-꙱꙱-꙱2-꙱ Modbus® RTU via RS-485 or HART (field
selectable)
Relays
UD2100 -꙱꙱-꙱꙱-꙱꙱-꙱꙱-A Standard – 2 relays, rated 5 amp SPDT,
programmable
www.gfps.com
Ordering Information
Config. Code Code Description
UD2100-A1-A1-A1-A1-A 159 300 320 UD2100 | 100 to 240 VAC | 4 to 20 mA, Pulse | 7.6 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-A1-A1-A1-B1-A 159 300 321 UD2100 | 100 to 240 VAC | 4 to 20 mA, Pulse | 15 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-A1-A1-A1-C1-A 159 300 322 UD2100 | 100 to 240 VAC | 4 to 20 mA, Pulse | 30 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-A1-A1-A1-A2-A 159 300 323 UD2100 | 100 to 240 VAC | Modbus, 4 to 20 mA, Pulse | 7.6 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-A1-A1-A1-B2-A 159 300 324 UD2100 | 100 to 240 VAC | Modbus, 4 to 20 mA, Pulse | 15 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-A1-A1-A1-C2-A 159 300 325 UD2100 | 100 to 240 VAC | Modbus, 4 to 20 mA, Pulse | 30 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-B1-A1-A1-A1-A 159 300 326 UD2100 | 9 to 32 VDC | 4 to 20 mA, Pulse | 7.6 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-B1-A1-A1-B1-A 159 300 327 UD2100 | 9 to 32 VDC | 4 to 20 mA, Pulse | 15 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-B1-A1-A1-C1-A 159 300 328 UD2100 | 9 to 32 VDC | 4 to 20 mA, Pulse | 30 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-B1-A1-A1-A2-A 159 300 329 UD2100 | 9 to 32 VDC | Modbus, 4 to 20 mA, Pulse | 7.6 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-B1-A1-A1-B2-A 159 300 330 UD2100 | 9 to 32 VDC | Modbus, 4 to 20 mA, Pulse | 15 m cable | NEMA4X/IP66 | -20 to 60 °C
UD2100-B1-A1-A1-C2-A 159 300 331 UD2100 | 9 to 32 VDC | Modbus, 4 to 20 mA, Pulse | 30 m cable | NEMA4X/IP66 | -20 to 60 °C
Spare Parts & Accessories
Code Description
159 300 340 Standard clamp-On Sensor with 25 ft / 7.6 m shielded coaxial pair
159 300 341 Standard clamp-On Sensor with 50 ft / 15 m length cable
159 300 342 Standard clamp-On Sensor with 100 ft / 30 m length cable
159 300 343 Sensor cable Junction Box
159 300 344 Sensor Mounting Kit with Couplant and SS clamps for pipes up to 32” (80 cm)
159 300 345 Enclosure Sunscreen (iridite aluminum)
159 300 038 Superlube coupling grease (85 g)
159 300 346 Extra sensor cable 20 ft / 6 m length
159 300 347 Extra sensor cable 35 ft / 10 m length
159 300 348 Extra sensor cable 175 ft / 50 m length
- Extra sensor cable custom length (up to 500 ft / 152 m, RG174U shielded coaxial pair)
Rev B 06/21