5th Edition
Updates
- Serveillance Cameas Coverage Locations
Update Note: Installment of CCTV in the elevators is not mandatory
First: General Requirements and Specifications of Security
Surveillance Systems
1. Surveillance cameras technical specifications and conditions of use:
A. Only fixed cameras shall be used.
B. IR cameras shall be installed for outdoor surveillance.
C. Cameras with WDR or any other technology should be used in a two - part
scene with continuous unequal lighting.
D. Cameras with Auto Iris facility shall be installed in locations with constantly
changing lighting.
E. Outdoor cameras shall be suitable with different weather conditions.
F. Outdoor cameras of a protection rating not lower than IP66 shall be used.
G. Cameras with zoom in facility shall not be used in private locations without
prior approval of concerned authority.
H. It is prohibited to use covert cameras without prior approval of concerned
authority.
I. Outdoor cameras with a field of view extending beyond the limits of the
facility shall not be installed on either roof or side of the building without
prior approval of concerned authority.
J. A record or a map showing locations of all cameras shall be provided.
K. Indoor and outdoor cameras shall be cleaned on a regular basis to ensure
good operation.
L. Cameras with features appropriate for the following locations shall be used:
No. Location Feature
1 Locations with a varying lighting view BMB - W□R- SOR
2 Locations where lighting varies according to time Auto IRIS
3 Locations with dim or semi dim lighting. Day and Night
4 Locations where lighting completely and rapidly changes AES or BL[
s Locations with no lighting IR
6 Poorly - lit locations. Low Lux
The protection of connections in the interior of the facility must be
through plastic tubes and metal pipes specially designed for use in the
outdoor environment .
( It will be determined by Sharjah Police ).
7. Storage system shall be Raids at a minimum (For Banks, Many Exchanges, Gold
Shops, Goldsmiths).
B. Recorders Must be kept in dedicated control room or in a rack in secured
environment so as not to be tampered with.
9. Recording system shall allow copying of images and videos.
10. Recording system shall be capable of viewing camera number, date and time
on both live display and recorded videos.
11. Recording system shall support recorded videos search based on camera
number, time and date.
12. Date and time set on recording system shall be real time and date.
13. All cameras shall be labeled and numbered on the recorder as per their
respective locations.
14. Recording system shall support at least the video compression standard H.264.
15. Recording system shall support continuous motion and alarm based recording.
16. In case of motion, recording system shall be set to record forl □ seconds pre
and post recording.
17. Recording system shall restart automatically in case of auto-restart or power
restoration or any other reason.
The area surrounding and opposite the facility monitor.
Automatic Number
Entrances and exits of vehicles leading to and from the facility. Plate Recognition
Fifth: Terms and Conditions
1. The certificate should be placed in prominent and clear place at the
entrance to the internal facility .
2. The certificate must be renewed annually.
The reference number for the application of inspection request is
mentioned as shown in the page 9, where the last page file is used
Type The reference number of Inspection request on the poster and
printed on the poster size A4, the poster should be pasted horizontally to
the facade of the shops, facilities and buildings from the inside so as not
to be affected by weather factors before inspecting them
An illustrative picture of the poster approved by the Sharjah Police
General Command for the Critical infrastructure protection service
WARNING
áYɰùdG QGóe ≈∏Y á«æeC’G áÑbGôŸG ᪶fC’ ™°†îj ¿ÉµŸG
This Area is Under 24 HourCCTV Surveillance
RFN: