Drawing - STi+4.4 Release-09 (Rev 0) System Health Connection

Uploaded by

muhammad.sadiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
80 views1 page

Drawing - STi+4.4 Release-09 (Rev 0) System Health Connection

Uploaded by

muhammad.sadiq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8

REV. DESCRIPTION ISSUED APV'D


0 ORIGINAL ISSUE 12-12-2016 AM
DO NOT SCALE

A A
SCENARIO 1 SCENARIO 2
LIGHT ON WHEN SYSTEM IS HEALTHY. LIGHT ON WHEN FAULT HAS BEEN DETECTED.

NOT ILLUMINATED WHEN FAULT HAS BEEN DETECTED. NOT ILLUMINATED WHEN SYSTEM IS HEALTHY.

+ - - + - + B1A1 E B2A2 E + - + - - + - + B1A1 E B2A2 E


B B
J209 J102 J104 J401 J402 J209 J102 J104 J401 J402
TUBE POWER POWER COMMN. COMMN. TUBE POWER POWER COMMN. COMMN.
ISOLATE BUS BUS BUS BUS ISOLATE BUS BUS BUS BUS
24VDC 24VDC OUT 24 VDC EXTN.CARD MODBUS RTU 24VDC 24VDC OUT 24 VDC EXTN.CARD MODBUS RTU
OUT EXTN.CARD SPARE OUT EXTN.CARD SPARE

A A
MODULAR POWER SUPPLY UNIT MODULAR POWER SUPPLY UNIT
N N
C C
PANEL MOUNTED PANEL MOUNTED
GLOBE BY OTHERS GLOBE BY OTHERS

0.4amp MAX. 0.4amp MAX.

J306 J306
J106

J106
-

-
SOLENOID ACTIVES SOLENOID ACTIVES
+

+
3 4 5 6 7 8 9 10 2 3 4 5 6 7 8 9 10
J103

J103
OUTPUT RELAY CONNECTIONS
E

E
OUTPUT RELAY CONNECTIONS

D D
E

E
J213 J212 J211 J210 J213 J212 J211 J210
SYSTEM SENSOR SENSOR GENERAL SYSTEM SENSOR SENSOR GENERAL
HEALTH 2 1 WARNINGS HEALTH 2 1 WARNINGS

Com4 Com3 Com2 Com1 Com4 Com3 Com2 Com1


NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO NC COM NO

E E

THIS DRAWING CONTAINS INFORMATION CONFIDENTIAL AND/OR PROPRIETARY TO


NOTES DONALDSON AUSTRALASIA. ALL RIGHTS TO DISCLOSE, COPY, REPRODUCE,
MANUFACTURE FROM OR DISPOSE THIS DRAWING OR ITS CONTENTS ARE RESERVED

1: THE 24VDC OUT SUPPLY FROM THE PULSE TIMER IS RATED TO A MAX.
UNLESS SPECIFIED IN WRITING BY DONALDSON AUSTRALASIA.
10 Watt. IF THE OUTPUT SYSTEM (ILLUSTRATED WITH GLOBE) USED TO
DETECT THE ALARM DRAWS MORE THAN THIS, THE SYSTEM MAY NOT DRAWING PROJECT REFERENCE TITLE or DESCRIPTION
WORK AS DESIRED WHEN POWERED THROUGH THE ON-BOARD POWER SUPPLY.
2: WHEN THE LOAD IS HIGHER, USER MUST REPLACE THE ONBOARD POWER STi+ 4.4 Timer Connection Example
SUPPLY (JUNCTION J104) WITH A SUITABLY SIZED EXTERNAL POWER SUPPLY.
®
DWG. NO. REV. NO. SHEET Donaldson
F F
System Health Relay
09 0 A4 Australasia
DRAWN CHK'D APV'D STi Plus
Card Version 4.4 IAF
PTK DO AM