Design of Column

Sixt Story
Edge Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
5002 1716 410 906 87 89 738 1099 677
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
7452 2198.4 634.4
Design Steps for Cobination 1
bc 35
hc 35
Lc 250
bb 35
hb 40
Lb1 285 Lb3
Lb2 341 Lb4
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 500.2083
Kb1=Ib/Lb1 654.9708
Kb2=Ib/Lb2 547.4096
∑Kc 1000.417
∑Kb 1202.38
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.416015
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.83203
K from Nomograph 1.19
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 28.57142857 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 894.24
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.939721
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6515798492
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 74520
Pc= (π^2EI) / (K Lu) ^2 713812.9646
ΣPc 7138129.646
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.01514
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.715429
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.726261 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 3106.178
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
6908.4 2146.2 581
(1EQ) 738 1099 677
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 829.008
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.91583
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6597053264
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 69084
Pc= (π^2EI) / (K Lu) ^2 544580.1648
ΣPc 5445801.648
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.018457
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.708284
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.721357 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 3265.484
Pu 7646.4

Summary of design
Pu Mu
Combination1 7452 3106.17849107594
Combination2 7646.4 3265.48420502674
kn=Pu/(Φfc'*b*h) 0.02556
Rn=Mu/(Φfc'*b*h^2) 0.03044
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
kn=Pu/(Φfc'*b*h) 0.026227
Rn=Mu/(Φfc'*b*h^2) 0.032001
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
Use Φ20mm as(cm2) 3.14
No of bars 4
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
581
677
Design of Column
Sixt Story
Exterior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
9061 226 124 1629 22.4 10.4 179 1438 694
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
13479.6 307.04 165.44
Design Steps for Cobination 1
bc 35
hc 35
Lc 250
bb 35
hb 40
Lb1 285 Lb3 285
Lb2 341 Lb4
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 500.2083
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 654.9708
Kb2=Ib/Lb2 547.4096
∑Kc 1000.417
∑Kb 1857.351
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.26931275
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.538625501
K from Nomograph 1.14
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 28.57142857 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 1617.552
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.941081
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6511231725
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 94357.2
Pc= (π^2EI) / (K Lu) ^2 713312.6702
ΣPc 4993188.691
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.027744978
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.815528921
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.838155754 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 1969.470945
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
12502.2 293.6 159.2
(1EQ) 179 1438 694
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 1500.264
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.000331
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6318368875
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 125022
Pc= (π^2EI) / (K Lu) ^2 521575.0466
ΣPc 5215750.466
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.035457142
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.816893733
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.84585845 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 1782.58737
Pu 12681.2

Summary of design
Pu Mu
Combination1 13479.6 1969.47094520992
Combination2 12681.2 1782.58736993921
kn=Pu/(Φfc'*b*h) 0.046234265
Rn=Mu/(Φfc'*b*h^2) 0.019300497
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
kn=Pu/(Φfc'*b*h) 0.043495798
Rn=Mu/(Φfc'*b*h^2) 0.017469068
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
Use Φ20mm as(cm2) 3.14
No of bars 4
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
159.2
694
Design of Column
Sixt Story
Interior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
25818 3838 4063 3640 615 1252 1162 6604 5939
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
36805.6 5589.6 6878.8
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 285 Lb3 715
Lb2 341 Lb4 341
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 261.0723
Kb2=Ib/Lb2 547.4096 Kb4=Ib/Lb4 547.4096
∑Kc 868.4172
∑Kb 2010.862
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.432
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.432
K from Nomograph 1.15
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 32.91428571 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 4416.672
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.982057
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6376622815
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 561285.4
Pc= (π^2EI) / (K Lu) ^2 526383.8513
ΣPc 8027353.732
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.110972853
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.092257049
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.21346793 1 1.213468 is ok
Mu=Mc= бb*M2b+ бs*M2s 11689.60303
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
34621.6 5220.6 6127.6
(1EQ) 1162 6604 5939
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 4154.592
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.010105
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6287646270
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 527979.4
Pc= (π^2EI) / (K Lu) ^2 519038.9262
ΣPc 7915343.625
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.105327061
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.069493928
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.18214058 1 1.182141 is ok
Mu=Mc= бb*M2b+ бs*M2s 13471.06303
Pu 35783.6

Summary of design
Pu Mu
Combination1 36805.6 11689.6030330174
Combination2 35783.6 13471.0630278414
kn=Pu/(Φfc'*b*h) 0.126241125
Rn=Mu/(Φfc'*b*h^2) 0.11455622
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0.012
ρmin 0.01
ρreq 0.012
As=ρreq*Ag 14.7
kn=Pu/(Φfc'*b*h) 0.123
Rn=Mu/(Φfc'*b*h^2) 0.132
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.0125
ρmin 0.01
ρreq 0.0125
As=ρreq*Ag 15.3125
Use Φ20mm as(cm2) 3.14
No of bars 5
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
6127.6
5939
Design of Column
Sixt Story
Exterior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
6599 1608 1239 484 148 328 859 6085 5374
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
8693.2 2166.4 2011.6
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 285 Lb3 341
Lb2 565 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 547.4096
Kb2=Ib/Lb2 330.3835 Kb4=Ib/Lb4
∑Kc 868.4172
∑Kb 1532.764
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.567
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.567
K from Nomograph 1.16
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 32.914 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 1043.184
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.062739
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6127208664
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 182991.86
Pc= (π^2EI) / (K Lu) ^2 505794.9619
ΣPc 10191768.48
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.026325044
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.971418021
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.995869755 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 3237.045865
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
8402.8 2077.6 1814.8
(1EQ) 859 6085 5374
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 1008.336
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.997495
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6327339910
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 169316.42
Pc= (π^2EI) / (K Lu) ^2 522315.5966
ΣPc 10524659.27
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.023522883
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.949403157
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.971735857 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 8305.736743
Pu 9261.8

Summary of design
Pu Mu
Combination1 8693.2 3237.04586487259
Combination2 9261.8 8305.73674328214
kn=Pu/(Φfc'*b*h) 0.030
Rn=Mu/(Φfc'*b*h^2) 0.032
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
kn=Pu/(Φfc'*b*h) 0.032
Rn=Mu/(Φfc'*b*h^2) 0.081
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
Use Φ20mm as(cm2) 3.14
No of bars 4
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
1814.8
5374
Design of Column
Sixt Story
Edge Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
18233 7549 4657 1754 1002 1609 821 3057 1335
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
24686 10662 8162.8
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 715 Lb3 0
Lb2 341 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 261.0723 Kb3=Ib/Lb3
Kb2=Ib/Lb2 547.4096 Kb4=Ib/Lb4
∑Kc 868.4172
∑Kb 808.4818
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 1.074
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 1.074
K from Nomograph 1.32
Kmin 1.2
Kreq 1.32
r=0.3h 10.5
Klu/r<22 36.206 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 2962.32
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.034035
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6213672512
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 752923
Pc= (π^2EI) / (K Lu) ^2 423911.1292
ΣPc 12929289.44
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.090740075
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.90623898
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.988471173 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 13893.12114
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
23633.6 10060.8 7197.4
(1EQ) 821 3057 1335
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 2836.032
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.04382
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6183925459
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 720824.8
Pc= (π^2EI) / (K Lu) ^2 421881.7163
ΣPc 12867392.35
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.086989424
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.88615617
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.963242385 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 13383.72667
Pu 24454.6

Summary of design
Pu Mu
Combination1 24686 13893.1211404022
Combination2 24454.6 13383.7266691863
kn=Pu/(Φfc'*b*h) 0.085
Rn=Mu/(Φfc'*b*h^2) 0.136
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0.01
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
kn=Pu/(Φfc'*b*h) 0.084
Rn=Mu/(Φfc'*b*h^2) 0.131
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.015
ρmin 0.01
ρreq 0.015
As=ρreq*Ag 18.375
Use Φ20mm as(cm2) 3.14
No of bars 6
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
7197.4
1335
Design of Column
Sixt Story
Exterior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
19583 1511 1563 2273 390 379 5580 10125 9481
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
27136.4 2437.2 2482
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 285 Lb3 341
Lb2 565 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 547.4096
Kb2=Ib/Lb2 330.3835 Kb4=Ib/Lb4
∑Kc 868.4172
∑Kb 1532.764
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.567
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.567
K from Nomograph 1.16
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 32.914 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 3256.368
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.010311
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6287002946
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 571221.22
Pc= (π^2EI) / (K Lu) ^2 518985.8205
ΣPc 10457564.28
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.08463698
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.0073527
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.088672429 1 1.088672 is ok
Mu=Mc= бb*M2b+ бs*M2s 6185.289596
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
25772.6 2203.2 2254.6
(1EQ) 5580 10125 9481
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 3092.712
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.874447
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6742696696
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 519317.89
Pc= (π^2EI) / (K Lu) ^2 556602.8849
ΣPc 11215548.13
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.070833149
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.009331881
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.080826036 1 1.080826 is ok
Mu=Mc= бb*M2b+ бs*M2s 13223.46155
Pu 31352.6

Summary of design
Pu Mu
Combination1 27136.4 6185.28959644252
Combination2 31352.6 13223.4615523469
kn=Pu/(Φfc'*b*h) 0.093
Rn=Mu/(Φfc'*b*h^2) 0.061
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
kn=Pu/(Φfc'*b*h) 0.108
Rn=Mu/(Φfc'*b*h^2) 0.130
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.015
ρmin 0.01
ρreq 0.015
As=ρreq*Ag 18.375
Use Φ20mm as(cm2) 3.14
No of bars 6
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
2254.6
9481
Design of Column
Sixt Story
Interior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
47565 4060 3981 10555 1820 1693 2118 10735 10012
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
73966 7784 7486
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 285 Lb3 715
Lb2 341 Lb4 341
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 261.0723
Kb2=Ib/Lb2 547.4096 Kb4=Ib/Lb4 547.4096
∑Kc 868.4172
∑Kb 2010.862
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.432
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.432
K from Nomograph 1.15
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 32.91428571 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 8875.92
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.900292
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6650993749
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1127981.5
Pc= (π^2EI) / (K Lu) ^2 549032.8981
ΣPc 8372751.696
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.238325519
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.984686536
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.219362467 1 1.219362 is ok
Mu=Mc= бb*M2b+ бs*M2s 20482.79568
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
67633 6692 6470.2
(1EQ) 2118 10735 10012
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 8115.96
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.954696
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6465880347
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1031403.25
Pc= (π^2EI) / (K Lu) ^2 533751.9715
ΣPc 8139717.565
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.221027658
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.986742379
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.204839736 1 1.20484 is ok
Mu=Mc= бb*M2b+ бs*M2s 21170.51941
Pu 69751

Summary of design
Pu Mu
Combination1 73966 20482.7956822182
Combination2 69751 21170.519413552
kn=Pu/(Φfc'*b*h) 0.254
Rn=Mu/(Φfc'*b*h^2) 0.201
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0.019
ρmin 0.01
ρreq 0.019
As=ρreq*Ag 23.275
kn=Pu/(Φfc'*b*h) 0.239
Rn=Mu/(Φfc'*b*h^2) 0.207
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.02
ρmin 0.01
ρreq 0.02
As=ρreq*Ag 24.5
Use Φ20mm as(cm2) 3.14
No of bars 8
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
6470.2
10012
Design of Column
Sixt Story
Edge Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
36728 2742 8131 6639 1949 1791 2289 4328 2926
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
54696 6408.8 12622.8
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 715 Lb3 0
Lb2 341 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 261.0723 Kb3=Ib/Lb3
Kb2=Ib/Lb2 547.4096 Kb4=Ib/Lb4
∑Kc 868.4172
∑Kb 808.4818
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 1.074
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 1.074
K from Nomograph 1.32
Kmin 1.2
Kreq 1.32
r=0.3h 10.5
Klu/r<22 36.206 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 6563.52
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.940091
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6514556509
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1668228
Pc= (π^2EI) / (K Lu) ^2 444438.1323
ΣPc 13555363.03
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.213314037
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.387841718
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.683887837 1 1.683888 is ok
Mu=Mc= бb*M2b+ бs*M2s 18755.31132
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
50712.6 5239.4 11548.2
(1EQ) 2289 4328 2926
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 6085.512
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.970144
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6415180047
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1546734.3
Pc= (π^2EI) / (K Lu) ^2 437658.4399
ΣPc 13348582.42
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.198368612
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.481642936
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.775554389 1 1.775554 is ok
Mu=Mc= бb*M2b+ бs*M2s 14489.37902
Pu 53001.6

Summary of design
Pu Mu
Combination1 54696 18755.3113209516
Combination2 53001.6 14489.3790181547
kn=Pu/(Φfc'*b*h) 0.188
Rn=Mu/(Φfc'*b*h^2) 0.184
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0.021
ρmin 0.01
ρreq 0.021
As=ρreq*Ag 25.725
kn=Pu/(Φfc'*b*h) 0.182
Rn=Mu/(Φfc'*b*h^2) 0.142
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.015
ρmin 0.01
ρreq 0.015
As=ρreq*Ag 18.375
Use Φ20mm as(cm2) 3.14
No of bars 6
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
11548.2
2926
Design of Column
Sixt Story
Interior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
70324 4379 4631 13023 1712 1801 3447 12077 12776
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
105225.6 7994 8438.8
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 285 Lb3 715
Lb2 341 Lb4 341
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 261.0723
Kb2=Ib/Lb2 547.4096 Kb4=Ib/Lb4 547.4096
∑Kc 868.4172
∑Kb 2010.862
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.432
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.432
K from Nomograph 1.15
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 32.91428571 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 12627.072
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.935643
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6529525404
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1604690.4
Pc= (π^2EI) / (K Lu) ^2 539005.8074
ΣPc 8219838.563
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.386747257
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.022256693
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.417611664 1 1.417612 is ok
Mu=Mc= бb*M2b+ бs*M2s 28842.9451
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
97411.8 6966.8 7358.2
(1EQ) 3447 12077 12776
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 11689.416
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.976153
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6395674660
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1485529.95
Pc= (π^2EI) / (K Lu) ^2 527956.5621
ΣPc 8051337.572
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.357923978
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.022472297
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.388439649 1 1.38844 is ok
Mu=Mc= бb*M2b+ бs*M2s 26072.62922
Pu 100858.8

Summary of design
Pu Mu
Combination1 105225.6 28842.9450961664
Combination2 100858.8 26072.6292247684
kn=Pu/(Φfc'*b*h) 0.361
Rn=Mu/(Φfc'*b*h^2) 0.283
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0.04
ρmin 0.01
ρreq 0.04
As=ρreq*Ag 49
kn=Pu/(Φfc'*b*h) 0.346
Rn=Mu/(Φfc'*b*h^2) 0.256
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.039
ρmin 0.01
ρreq 0.039
As=ρreq*Ag 47.775
Use Φ20mm as(cm2) 3.14
No of bars 16
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
7358.2
12776
Design of Column
Sixt Story
Exterior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
33197 1407 1375 4189 208 132 11936 11665 12222
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
46538.8 2021.2 1861.2
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 285 Lb3 341
Lb2 565 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 654.9708 Kb3=Ib/Lb3 547.4096
Kb2=Ib/Lb2 330.3835 Kb4=Ib/Lb4
∑Kc 868.4172
∑Kb 1532.764
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.567
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.567
K from Nomograph 1.16
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 32.914 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 5584.656
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.998646
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6323695416
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 979641.74
Pc= (π^2EI) / (K Lu) ^2 522014.7472
ΣPc 10518597.16
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.153467648
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.968335642
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.109662714 1 1.109663 is ok
Mu=Mc= бb*M2b+ бs*M2s 8684.570298
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
44025.4 1896.4 1782
(1EQ) 11936 11665 12222
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 5283.048
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.830497
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6904587814
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 887111.81
Pc= (π^2EI) / (K Lu) ^2 569966.8351
ΣPc 11484831.73
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.124032197
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.97587007
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.096909378 1 1.096909 is ok
Mu=Mc= бb*M2b+ бs*M2s 15192.01452
Pu 55961.4

Summary of design
Pu Mu
Combination1 46538.8 8684.57029759058
Combination2 55961.4 15192.0145208184
kn=Pu/(Φfc'*b*h) 0.160
Rn=Mu/(Φfc'*b*h^2) 0.085
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
kn=Pu/(Φfc'*b*h) 0.192
Rn=Mu/(Φfc'*b*h^2) 0.149
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.02
ρmin 0.01
ρreq 0.02
As=ρreq*Ag 24.5
Use Φ20mm as(cm2) 3.14
No of bars 8
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
1782
12222
Design of Column
Sixt Story
Edge Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
55789 3921 4499 11517 1911 2274 4320 4985 6153
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
85374 7762.8 9037.2
Design Steps for Cobination 1
bc 35
hc 35
Lc 288
bb 35
hb 40
Lb1 715 Lb3 0
Lb2 341 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 125052.1
Ib=b*h^3/12 186666.7
Kc=Ic/Lc 434.2086
Kb1=Ib/Lb1 261.0723 Kb3=Ib/Lb3
Kb2=Ib/Lb2 547.4096 Kb4=Ib/Lb4
∑Kc 868.4172
∑Kb 808.4818
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 1.074
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 1.074
K from Nomograph 1.32
Kmin 1.2
Kreq 1.32
r=0.3h 10.5
Klu/r<22 36.206 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 10244.88
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.914852
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6600420516
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 2603907
Pc= (π^2EI) / (K Lu) ^2 450295.9737
ΣPc 13734027.2
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.371460724
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.065667027
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.461520473 1 1.46152 is ok
Mu=Mc= бb*M2b+ бs*M2s 25395.94167
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
78463.8 6616.2 7672.8
(1EQ) 4320 4985 6153
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 9415.656
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.943477
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 125052.0833
EI= (Ec*Ig /2.5) /( 1 + βd) 6503205992
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 2393145.9
Pc= (π^2EI) / (K Lu) ^2 443663.7737
ΣPc 13531745.1
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.338059093
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.063879568
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.42353373 1 1.423534 is ok
Mu=Mc= бb*M2b+ бs*M2s 16088.60844
Pu 82783.8

Summary of design
Pu Mu
Combination1 85374 25395.9416659377
Combination2 82783.8 16088.608444639
kn=Pu/(Φfc'*b*h) 0.293
Rn=Mu/(Φfc'*b*h^2) 0.249
Cobinaation1

d' 5
γ=(h-2d')/h 0.7
ρg From nomograph 0.04
ρmin 0.01
ρreq 0.04
As=ρreq*Ag 49
kn=Pu/(Φfc'*b*h) 0.284
Rn=Mu/(Φfc'*b*h^2) 0.158
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.7
ρgFrom nomograph 0.017
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 12.25
Use Φ20mm as(cm2) 3.14
No of bars 16
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 35
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
7672.8
6153
Design of Column
Second Story
Interior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
94300 3024 2238 19941 1482 1619 5240 4114 4607
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
145065.6 6000 5276
Design Steps for Cobination 1
bc 40
hc 40
Lc 320
bb 40
hb 50
Lb1 285 Lb3 715
Lb2 341 Lb4 341
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 213333.3
Ib=b*h^3/12 416666.7
Kc=Ic/Lc 666.6667
Kb1=Ib/Lb1 1461.988 Kb3=Ib/Lb3 582.7506
Kb2=Ib/Lb2 1221.896 Kb4=Ib/Lb4 1221.896
∑Kc 1333.333
∑Kb 4488.532
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.297
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.297
K from Nomograph 1.1
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 36.57142857 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 17407.872
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.910071
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 11288211967
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 2212250.4
Pc= (π^2EI) / (K Lu) ^2 754782.8146
ΣPc 11510437.92
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.378482318
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.951733333
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.311947572 1 1.311948 is ok
Mu=Mc= бb*M2b+ бs*M2s 31868.12918
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
133101 5110.8 4304.6
(1EQ) 5240 4114 4607
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 15972.12
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.954309
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 11032693167
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 2029790.25
Pc= (π^2EI) / (K Lu) ^2 910737.8133
ΣPc 13888751.65
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.263871765
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.936902246
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.184124295 1 1.184124 is ok
Mu=Mc= бb*M2b+ бs*M2s 11251.39089
Pu 138341

Summary of design
Pu Mu
Combination1 145065.6 31868.1291793943
Combination2 138341 11251.3908876775
kn=Pu/(Φfc'*b*h) 0.498
Rn=Mu/(Φfc'*b*h^2) 0.312
Cobinaation1

d' 5
γ=(h-2d')/h 0.8
ρg From nomograph 0.055
ρmin 0.01
ρreq 0.055
As=ρreq*Ag 88
kn=Pu/(Φfc'*b*h) 0.363
Rn=Mu/(Φfc'*b*h^2) 0.074
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.8
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 16
Use Φ20mm as(cm2) 4.5
No of bars 20
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 38


48Dia of Stirrups 48
Least dimension of column 40
Use Φ10mm @38cm c/c
MB=(1.2MDL+1MLL)
4304.6
4607
Design of Column
Second Story
Exterior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
47116 2112 2111 5817 948 1317 17007 3994 4157
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
65846.4 4051.2 4640.4
Design Steps for Cobination 1
bc 40
hc 40
Lc 320
bb 40
hb 50
Lb1 285 Lb3 341
Lb2 565 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 213333.3
Ib=b*h^3/12 416666.7
Kc=Ic/Lc 666.6667
Kb1=Ib/Lb1 1461.988 Kb3=Ib/Lb3 1221.896
Kb2=Ib/Lb2 737.4631 Kb4=Ib/Lb4
∑Kc 1333.333
∑Kb 3421.348
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.390
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.390
K from Nomograph 1.13
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 36.571 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 7901.568
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.001762
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 10771155687
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1386066.72
Pc= (π^2EI) / (K Lu) ^2 720210.0058
ΣPc 14512231.62
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.158001419
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.058175355
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.217146247 1 1.217146 is ok
Mu=Mc= бb*M2b+ бs*M2s 14080.92983
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
62356.2 3482.4 3850.2
(1EQ) 17007 3994 4157
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 7482.744
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.831146
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 11774750665
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1256477.43
Pc= (π^2EI) / (K Lu) ^2 971993.9194
ΣPc 19585677.48
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.100893544
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 1.042246726
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.147402693 1 1.147403 is ok
Mu=Mc= бb*M2b+ бs*M2s 8392.683952
Pu 79363.2

Summary of design
Pu Mu
Combination1 65846.4 14080.929828657
Combination2 79363.2 8392.68395199645
kn=Pu/(Φfc'*b*h) 0.226
Rn=Mu/(Φfc'*b*h^2) 0.138
Cobinaation1

d' 5
γ=(h-2d')/h 0.8
ρg From nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 16
kn=Pu/(Φfc'*b*h) 0.208
Rn=Mu/(Φfc'*b*h^2) 0.055
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.8
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 16
Use Φ20mm as(cm2) 3.14
No of bars 5
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 40
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
3850.2
4157
Design of Column
Second Story
Edge Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
75739 1964 991 16324 1033 530 5830 55 1784
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
117005.2 4009.6 2037.2
Design Steps for Cobination 1
bc 50
hc 50
Lc 592
bb 50
hb 50
Lb1 715 Lb3 0
Lb2 341 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 520833.3
Ib=b*h^3/12 520833.3
Kc=Ic/Lc 879.786
Kb1=Ib/Lb1 728.4382 Kb3=Ib/Lb3
Kb2=Ib/Lb2 1527.37 Kb4=Ib/Lb4
∑Kc 1759.572
∑Kb 2255.809
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.780
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.780
K from Nomograph 1.26
Kmin 1.2
Kreq 1.26
r=0.3h 10.5
Klu/r<22 71.040 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 14040.624
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.906238
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 520833.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 27614521478
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 3568658.6
Pc= (π^2EI) / (K Lu) ^2 489341.7991
ΣPc 14924924.87
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.518791709
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.803232243
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 1.21994247 1 1.219942 is ok
Mu=Mc= бb*M2b+ бs*M2s 26216.26464
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
107210.8 3389.8 1719.2
(1EQ) 5830 55 1784
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 12865.296
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.938021
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 520833.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 27161661632
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 3269929.4
Pc= (π^2EI) / (K Lu) ^2 2033712.533
ΣPc 62028232.26
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.081443163
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.802867426
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.868255488 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 3449.279374
Pu 113040.8

Summary of design
Pu Mu
Combination1 117005.2 26216.2646423397
Combination2 113040.8 3449.27937395373
kn=Pu/(Φfc'*b*h) 0.401
Rn=Mu/(Φfc'*b*h^2) 0.257
Cobinaation1

d' 5
γ=(h-2d')/h 0.8
ρg From nomograph 0.038
ρmin 0.01
ρreq 0.038
As=ρreq*Ag 95
kn=Pu/(Φfc'*b*h) 0.190
Rn=Mu/(Φfc'*b*h^2) 0.012
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.8
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 25
Use Φ24mm as(cm2) 4.5
No of bars 21 Use 22
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 38.4


48Dia of Stirrups 48
Least dimension of column 50
Use Φ10mm @38cm c/c
MB=(1.2MDL+1MLL)
1719.2
1784
Design of Column
First Story
Interior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
120651 1340 648 39813 1873 1131 7221 11599 13443
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
208482 4604.8 2587.2
Design Steps for Cobination 1
bc 50
hc 50
Lc 272
bb 50
hb 50
Lb1 285 Lb3 715
Lb2 341 Lb4 341
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 520833.3
Ib=b*h^3/12 520833.3
Kc=Ic/Lc 1914.828
Kb1=Ib/Lb1 1827.485 Kb3=Ib/Lb3 728.4382
Kb2=Ib/Lb2 1527.37 Kb4=Ib/Lb4 1527.37
∑Kc 3829.657
∑Kb 5610.665
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.683
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.683
K from Nomograph 1.22
Kmin 1.2
Kreq 1.22
r=0.3h 10.5
Klu/r<22 31.60380952 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 25017.84
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.810197
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 520833.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 29079637569
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 3179350.5
Pc= (π^2EI) / (K Lu) ^2 2603699.239
ΣPc 39706413.4
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.129162404
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.824739402
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.931264726 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 32854.00434
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
184594.2 3481 1908.6
(1EQ) 7221 11599 13443
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 22151.304
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.880594
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 520833.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 27991074887
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 2815061.55
Pc= (π^2EI) / (K Lu) ^2 2235497.741
ΣPc 34091340.56
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.133739276
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.819316288
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.928891056 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 16631.24186
Pu 191815.2

Summary of design
Pu Mu
Combination1 208482 32854.0043448706
Combination2 191815.2 16631.2418627459
kn=Pu/(Φfc'*b*h) 0.715
Rn=Mu/(Φfc'*b*h^2) 0.322
Cobinaation1

d' 5
γ=(h-2d')/h 0.8
ρg From nomograph 0.063
ρmin 0.01
ρreq 0.063
As=ρreq*Ag 157.5
kn=Pu/(Φfc'*b*h) 0.322
Rn=Mu/(Φfc'*b*h^2) 0.056
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.8
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 25
Use Φ30mm as(cm2) 7.1
No of bars 22
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 48


48Dia of Stirrups 48
Least dimension of column 50
Use Φ10mm @48cm c/c
MB=(1.2MDL+1MLL)
1908.6
13443
Design of Column
First Story
Exterior Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
65003 1798 999 9864 1250 629 21053 10525 12430
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
93786 4157.6 2205.2
Design Steps for Cobination 1
bc 40
hc 40
Lc 272
bb 40
hb 50
Lb1 285 Lb3 341
Lb2 565 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 213333.3
Ib=b*h^3/12 416666.7
Kc=Ic/Lc 784.3137
Kb1=Ib/Lb1 1461.988 Kb3=Ib/Lb3 1221.896
Kb2=Ib/Lb2 737.4631 Kb4=Ib/Lb4
∑Kc 1568.627
∑Kb 3421.348
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.458
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.458
K from Nomograph 1.15
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 31.086 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 11254.32
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.970339
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 10942933286
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1974195.3
Pc= (π^2EI) / (K Lu) ^2 1012727.837
ΣPc 20406465.91
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.160368988
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.812160862
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.935988549 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 17216.76391
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1M
Combination 2
87867.6 3407.6 1827.8
(1EQ) 21053 10525 12430
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 10544.112
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.83551
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 11746758178
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 1770532.14
Pc= (π^2EI) / (K Lu) ^2 969683.1676
ΣPc 19539115.83
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.148698631
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.814555699
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.935679017 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 15497.65309
Pu 108920.6

Summary of design
Pu Mu
Combination1 93786 17216.7639107929
Combination2 108920.6 15497.6530942239
kn=Pu/(Φfc'*b*h) 0.322
Rn=Mu/(Φfc'*b*h^2) 0.169
Cobinaation1

d' 5
γ=(h-2d')/h 0.8
ρg From nomograph 0.025
ρmin 0.01
ρreq 0.025
As=ρreq*Ag 40
kn=Pu/(Φfc'*b*h) 0.286
Rn=Mu/(Φfc'*b*h^2) 0.102
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.8
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 16
Use Φ20mm as(cm2) 3.14
No of bars 13 Use 14
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 32


48Dia of Stirrups 48
Least dimension of column 40
Use Φ10mm @32cm c/c
MB=(1.2MDL+1MLL)
1827.8
12430
Design of Column
First Story
Edge Column
Dead Load Live Load Earthquak Load
Unfactored loads Pu(kg) MT(kg-m) MB Pu MT MB Pu MT MB
87956 2666 1233 13173 2058 1025 3660 7229 1233
Combination 1 Pu=1,2DL+1,6LL MT=1.2MDL+1.6MLL MB=1.2MDL+1.6MLL
126624 6492 3119.6
Design Steps for Cobination 1
bc 40
hc 40
Lc 272
bb 40
hb 50
Lb1 565 Lb3 0
Lb2 341 Lb4 0
fy 4200
fc' 280
1- Klu/r<22 For unbraced column
ψ=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb)
Ic=b*h^3/12 213333.3333
Ib=b*h^3/12 416666.6667
Kc=Ic/Lc 784.3137255
Kb1=Ib/Lb1 737.4631268 Kb3=Ib/Lb3
Kb2=Ib/Lb2 1221.896383 Kb4=Ib/Lb4
∑Kc 1568.627451
∑Kb 1959.35951
ψTop=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.801
ψbottom=(∑Ec*Ic/Lc)/(∑Eb*Ib/Lb) 0.801
K from Nomograph 1.13
Kmin 1.2
Kreq 1.2
r=0.3h 10.5
Klu/r<22 31.086 Column is Selender
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 15194.88
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 0.972472833
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 10931094359
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 3862032
Pc= (π^2EI) / (K Lu) ^2 1011632.188
ΣPc 30854781.73
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.217747145
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.792211953
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.964713844 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 24995.52174
Design Steps for Cobination 2
Pu=(1,2DL+1LL) MT=(1.2MDL+1MLL) MB=(1.2MDL+1MLL)
Combination 2
118720.2 5257.2 2504.6
(1EQ) 3660 7229 1233
2- Compute minimum moment for sway consideration
emin=1.5+0.3h 12
M2s=Mmin=Pu*emin 14246.424
3-EI= (Ec*Ig /2.5 / 1 + βd)
βd = (axial load due to factored dead load / total factored axial load )
βd 1.006195447
Ec = 15100√ f 'c 252671.328
Ig=b*h^3/12 213333.3333
EI= (Ec*Ig /2.5) /( 1 + βd) 10747351009
4- Compute magnified moment
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1
ΣPu 3620966.1
Pc= (π^2EI) / (K Lu) ^2 887183.1028
ΣPc 27059084.64
бs= (1/(1-ΣPu/ΦΣPc)) ≥ 1 1.236349424
бb= (cm/ (1-Pu/ΦPc)) ≥ 1
Cm = 0.6+0.4 (M1/M2) ≥ 0.4 0.79056532
бb= (cm/ (1-Pu/ΦPc)) ≥ 1 0.977414978 1 1 is ok
Mu=Mc= бb*M2b+ бs*M2s 14194.76999
Pu 122380.2

Summary of design
Pu Mu
Combination1 126624 24995.5217383788
Combination2 122380.2 14194.7699882738
kn=Pu/(Φfc'*b*h) 0.434
Rn=Mu/(Φfc'*b*h^2) 0.245
Cobinaation1

d' 5
γ=(h-2d')/h 0.8
ρg From nomograph 0.038
ρmin 0.01
ρreq 0.038
As=ρreq*Ag 60.8
kn=Pu/(Φfc'*b*h) 0.321
Rn=Mu/(Φfc'*b*h^2) 0.093
d' 5
Cobinaation2&3

γ=(h-2d')/h 0.8
ρgFrom nomograph 0
ρmin 0.01
ρreq 0.01
As=ρreq*Ag 16
Use Φ24mm as(cm2) 4.5
No of bars 14 Use 14
Design for Stirrups
Use Φ10mm as=0.785cm^2
Spacing

16Dia of main bar 38.4


48Dia of Stirrups 48
Least dimension of column 40
Use Φ10mm @38cm c/c