GRP Manhole Construction Details
GRP Manhole Construction Details
Min.50
75
200 min.
400 min.
DBC
Reinforced concrete C40
Pipe Port
250
Cover Slab
GRP Joint
Min. 50 Lamination at site
7mm GRP Skin Liner (In-side) (Out-side)
for cover slab (Out-side)
200
GRP Joint Lamination
70
70
7 EPDM Rubber 40x6mm
at factory ADD ON SHAFT RING ADD ON SHAFT RING
50mm Blinding 5 (If Required to Increase (If Required to Increase
Shaft (GRP Pipe) C40 Concrete Fil
the shaft height) the shaft height) KEY PLAN
7
Backfilling
DETAIL 'C' DETAIL 'D' OPTION - 1 OPTION - 2 NOTES:
1. DIMENSIONS AND CHAINAGES ARE IN METERS UNLESS STATED
OTHERWISE.
2. GRID DATA SPHEROID - WGS 84
Ø150mm WATERTIGHT FRAME & SINGLE PIECE COVER PROJECTION - UTM, ZONE 40
SILICA SAND NON-SLIP SURFACE
WITH GRP SEALING PLATE TO SUITE 750x600mm HORIZONTAL DATUM - WGS 84
ON BENCHING LAND (REFER NOTE-12)
AS REQUIRED
VERTICAL DATUM - ABU DHABI
REINFORCED CONCRETE C40
COVER SLAB
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS OTHERWISE
LIFTING BLOCK SHORT PIECE 300 STATED.
BACKDROP (SEE DETAIL 'X') 2. ALL CONCRETE TO BE C40 UNLESS OTHERWISE STATED.
MACHINED SEATING 3. MANHOLES ARE TO BE WATERTIGHT.
1:6
pe 4mm GRP BACKDROP SHUTTER
Slo
SHAFT DN 900
pe
1:6 300 min
GRP LINER AS SPECIFIED.
Ø150mm
R2
C C 5. SEWER GRADIENTS TO BE MAINTAINED THROUGH CHANNELS.
R1
FRAME LIP FOR SEALING PLATE 6. ALL PREFABRICATED GRP AND PRECAST CONCRETE UNITS
(4 LIPS) GAS TIGHT EPDM SHALL INCORPORATED SAFE LIFTING POINTS WHICH SHALL BE
C40 CONCRETE FILL AT SITE
1:6
pe
CLEARLY MARKED.
Slo
RUBBER (SEE NOTE 11)
Slo
pe
1:6 CLEAR OPENING 7. ALL GRP CUTOUTS FOR CONCRETE/AIR VENT HOLES SHALL BE
AS REQUIRED
FOR D.I. ACCESS COVER CLEAR OPENING AS STATED 7mm GRP LAMINATED AFTER CONCRETE IS DRY - AS PER ADSSC
GRP LINING ECR STANDARDS.
SHAFT (GRP Pipe) ON DRAWINGS MASS CONCRETE C20
GLASS,7mm.THICK 8. SHEAR KEY SHOULD BE MINIMUM 100x150x40mm AS PER ADSSC
GRP CUTOUT FOR STANDARD.
(C40 CONCRETE POURING) DETAIL "Z" 9. THE TOP OF THE MANHOLE SHALL BE FLUSHED WITH THE
KERB/PAVEMENT SURFACE.
(MANHOLE TOP, FRAME & PIPE CONNECTION DETAIL 10.BACKFILL MATERIAL SHOULD BE REPLACED IN LAYERS NOT
GRP SEALING PLATE DETIALS) EXCEED 150MM IN COMPACTED THICKNESS AND BE COMPACTED
FOR GRP AND uPVC PIPES TO THE OPTIMUM MOISTURE TO ACHIEVE 95% MAXIMUM DRY
SECTION PLAN D-D DENSITY (MDD).
11.EPDM RUBBER AS PER APPROVED MATERIAL SUBMITTAL/ AS
PER ADSWS APPROVED VENDORS.
300x300 CLEAR OPENING DOUBLE TRAIANGULAR 12.D.I COVER TO BE USED
D.I. COVER & FRAME (D400) · D400 FOR ASPHALT AREA
SEE DETAIL 'Z' SHAFT (GRP PIPE)
REINFORCED CONCRETE C40 · C250 FOR PAVED AREA
GRP JOINT LAMINATION
GRP END CAP COVER SLAB (AT SITE AS PER SPECS.) · B125 FOR UNPAVED / GREEN AREA
GRP SHEAR KEY
100
SOFTSCAPE (100x150x40mm) GRP 'Z' TYPE CONCRETE
TIES LAMINATED TO
MANHOLE SHAFT
150
FRAME FRAME FRAME
Ø150mm
50mm BLINIDNG CONCRETE C20 (TYPICAL)
BACKDROP PIPE
BACKFILLING DRAWING REFERENCE
DWG. NO. DWG. TITLE
SEE DETAIL 'C' EPDM SEAL 40X6mm (SEE NOTE 11)
OUTER LAYER
150
SHAFT (GRP PIPE)
STRUCTURAL LAYER GRP BACKDROP
LIFTING BLOCK WALL THICKNESS SHUTTER 4mm
(REFER TABLE-A)
INNER LAYER X Ø150mm 150
Manhole depth ≤ 4000mm (refer Table 'A')
300 min
BD IL
Pipe Ø
Contractor:
Eden Gardens L.L.C
RODDING EYE PLUG
(SEE DETAIL-ZZ)
GRP JOINT LAMINATION Tel : +971 2 6322888 P.O.B :25838
Fax : +971 2 6322877 [email protected]
GRP LAMINATED 10 GRP BRACKET LAMINATED www.egls.ae
10 TO MANHOLE SHAFT
10 Consultant:
D D
30
Ø150mm 150
MANHOLE SHAFT (GRP PIPE)
BACKDROP (SEE DETAIL 'X')
25
GRP BACKDROP SHUTTER 4mm S.S. CHAIN GRADE 316 S16
100
PIPE ID +28mm
PIPE ID -5mm
Drawing Title:
IL
PIPE ID
Z Z SH33_G1
C40 CONCRETE FILL AT SITE SEWERAGE STRUCTURAL MANHOLES
TYPICAL BACKDROP & GRP JOINT
500