NEK IEC 60529:1989
+A1:1999+A2:2013/COR1:2013
Engelsk-Fransk versjon
Corrigendum 1
Degrees of protection provided by enclosures (IP Code)
Norwegian electrotechnical publication
Provided by standard online as for Aker+Solutions 2023-03-17
NORSK ELEKTROTEKNISK KOMITE
Provided by standard online as for Aker+Solutions 2023-03-17
IEC 60529 CEI 60529
(Edition 2.2 – 2013) (Edition 2.2 – 2013)
Consolidated version Version consolidée
Degrees of protection provided by enclosures Degrés de protection procurés par les
(IP Code) enveloppes (Code IP)
CORRIGENDUM 1
NOTE This corrigendum concerns only NOTE Ce corrigendum ne concerne que
the consolidated version of IEC 60529, la version consolidée de la CEI 60529,
which was published in 2013-08. Additions publiée en 2013-08. Les ajouts et les
and deletions are displayed in red with a suppressions apparaissent en rouge avec
line in the margin, with deletions being une ligne verticale dans la marge, les
struck through. suppressions sont barrées.
14.2.9 Test for second characteristic The changes made in this Corrigendum
numeral 9 by high pressure and apply to the English version only.
temperature water jetting
After the third paragraph of this subclause,
Provided by standard online as for Aker+Solutions 2023-03-17
add the following new paragraph:
During the test a) or b) of the enclosure,
the water temperature shall be (80 ±
5) °C.
October 2013 Octobre 2013
Provided by standard online as for Aker+Solutions 2023-03-17
The Norwegian National Committee of © NEK har opphavsrett til denne publikasjon.
The International Electrotechnical Commission, IEC Ingen del av materialet må reproduseres på noen
The European Committee for Electrotechnical form for medium.
Standardization, CENELEC
For opphevelse av NEKs kopieringsrettigheter kreves
www.nek.no i hvert enkelt tilfelle skriftlig avtale med NEK