The Major Part of VRF System.

The document outlines the features and benefits of a high-efficiency outdoor unit designed by Mitsubishi Heavy Industries, emphasizing energy savings of up to 34% through advanced technologies like inverter control and variable temperature management. It highlights the ease of installation and maintenance, showcasing flexible design options and improved serviceability. Additionally, the unit offers a wide range of operation and enhanced durability with corrosion-resistant components.

Uploaded by

mmamurad2k2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
18 views6 pages

The Major Part of VRF System.

The document outlines the features and benefits of a high-efficiency outdoor unit designed by Mitsubishi Heavy Industries, emphasizing energy savings of up to 34% through advanced technologies like inverter control and variable temperature management. It highlights the ease of installation and maintenance, showcasing flexible design options and improved serviceability. Additionally, the unit offers a wide range of operation and enhanced durability with corrosion-resistant components.

Uploaded by

mmamurad2k2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 6
Outdoor unit 1. High Efficiency & Comfort High efficiency and compact design are achieved by applying advanced components Tetrahedral structure of “ Efficient Heat Exchanger Heat Exchanger Double tube Inverter Control Improved Scroll Compressor Variable Temperature and Capacity Control +The VICG is a energy saving function designed by Mitsubishi Heavy Industries Thermal Systems + A new feature to all our KXZ ranges which provides up to 34%" energy savings in both cooling and heating mode. *\VTGC is a function specifically designed to maximise energy savings in partial load conditions throughout Peeing all seasons, savings asd on campaign With KX sandal me with 4 RE sada mel oh une pil ad ain Normal operation (in the cooling mode) Energy saving operation (in the cooling mode) Room temperature Room temperature Check temp erature ditference ‘Set temperature Set temperature ! [oh Compressor/ V / =z ie it tt of of ot Target low pressure Target eee en ‘Constant lavel \VTCC adjusts the target pressure ofthe refrigerant cycle in the outdoor unit automatically according tothe demand of the indoor units in partial load conditions. These smooth adjustments ensure an optimal capacity usage ofthe indoor units as well as maximised energy savings. Ultimately this also increases comfort forthe user. For example, in partial load condltlons where you have low cooling and heating requirements, VICC reduces the compressor frequency and controls the actuators in the outdoor unit. (Overall with the VT'GC functionalty you will alvays have an additional energy saving of upto 34% (depending on configuration and usage of system) in low cooling and heating load requirements. Builder Maintenance Serviceability & workability A Easy and quick installation and maintenance Indoor unit is easily positioned and installed if ry aa) ‘Adjustable easier positioning of unit by new ‘New slit in panel allows easier installation FDOT, slits on site New shape of sits autabeto instalthe unit wth more | Flexible postioning is avaiable, which helps adjusting the fenbity, according to mary Kinds of suspending bok | erection of pare! accordingly to ines or pattem onthe pitch on ote, Py rectangular or squared pitch of Sen i re suspending bolts are available with this sii. | Quick installation and maintenance ott zi cay acces tocomponnt pa ron EE B- en am 1 The control box and bell mouth 2. Easy access to impeller New shape of path gives easy wiring work for installation can be removed together. and fan motor, No need to remove screws to open the ror a —— Conioet caver by smppe It ts posable to cee and she open the cover witout | When unite inated removing of the screws. with hook between This prevents the cover from falling and causing damage | washers, this stopper helps to install the unit safely, without adjusting washer. Separate me provisional ster sg ata Builder Maitenance Easy installation and maintenance W i Easy and flexible hook to romuea tin Ser P2) Securely fix the comer lid by strap Hook of soft material helps to The direction of the strap hook part has remove the filter without dust been changed from longitudinal to lateral. spreading ~ Furthermore, a barb has been added to the hook pin to prevent the strap from, coming off Andremove he iter. FDOT o Drain-up-lift increases up to 850 mm ‘New port to check drain water flow The drain can be lifted up to 850 mm from the ceiling surface. ‘A water supply port has been provided in the piping lid for easier testing of the drain water flow. (The port is usually sealed with a rubber cap) fom 700 eK 600 New 850 850 ; m7 o Re-use of packages during construction work ‘More flexible outlet for ducting Package material (carton) helps to protect the unit from Both 9125 and 4200 (oval shaped) are available, unexpected welding spatter or dust on the new unit. Spatter SEE 2. Design Flexibility Indoor u capacity connection KXZ 130% capacity connection Connectable indoor units Hp | 8 | 10 | 12] 16 | 18 | 20 Numbers] 22 | 24 | 29 | 39 | 43 | 48 24 58 a8 80 S\s 6 78 Wide Range of Operation ‘0G series permits an extensible system design witha heating range operation down to 20°C and a cooing range operation upto 62°C (previous model : 48°C) 3 Control Systems Al series offer wide choice of control system and provide the best solution, I [Control system units with SUPERLIN fhe Individual controler | Wied less Push buttons Center Console | Touch sereen 8 aus inerce [DRE sc-weawase 2561262) e nits Lonworks | SC-LGWNB 96 Vector control Applied Vector control has a high efficiency and many new Vector Control advanced features, Tro ‘Smooth operation from low speed to high speed + Smooth Sine Voltage Wave form are attained + Energy ficiency is further improved in low speed range. Operation period DC Fan Motor Rotor(Squirrel Cage made of conductor) Adoption of DC fan motor has enabled to Stator (col) Rotor(made of permanent magnet) realize an excellent efficiency of approximate (60% higher than previous models. o Oil level control capability Our proprietary technology adjusts the oll evel when ‘combining two or three outdoor units, achieving level operation rate, keeping performance ofthe units and ensuring long life ofthe system. Oil-equalizing pipe Capacity control The peak cut function can easly be set onthe controller. This function makes the control ofthe capacity easier and allow 8 better energy management ovr the long term. Four steps of capacity control are avalale with 80%, 60%, 40%, 0% (of). Schedule canbe set upto 4 operations/ay. tw) 80% A Long Pipe Length Piping length has extended max height diference between indoor units up to 18m and enables us to put indoor units on extra three floors, The furthest indoor unit: 160m or total length: 100m contributes to system design flxiilty vac 10m (oil equalizing pipe) Total length: Outdoor unit 1000m : Height difference ‘50m(outdoor unt above) 70m, 40m (outdoor unit below) Tothe first branch { max 130m, Max height difference between indoor units: 18m Indoor unit Indoor unit From the fst branch to the furthest indoor unit: 80m Furthest indoor unit: 160m *= The ference between the longest and the shortest indoor unt piping from the st branch must be within 40m. (MAX8Sm) Easy Transportation & Installation XZ portable and the uniform reduced footprint allows neat, continuous installation, Blue Fin ‘Due to application of blue coated fins on the heat exchanger of the new outdoor uni, corrosion resistance has been improved compared to previous models