ZXSDR Base Station Structure and
Principle
ZTE University
Content
ZXSDR Base Station Family Overview
ZXSDR Base Station Highlights
SDR Base Station Family overview
Distributed Macro: ZXSDR BS8700
Indoor Macro : ZXSDR BS8800
Outdoor Macro : ZXSDR BS8900A
Outdoor Micro : ZXSDR BS8906
Outdoor Mini : ZXSDR BS8908
GU
GU
Distributed BTS ZXSDR BS8700
BS8700
Antenn
a
BBU
BB
FS
E
1
STM1
GE/F
E
SA/
SE/
NIS
CP
RI
RRU
Radio
Radio
Unit
Unit
Fiber
CC
Control
Signaling
Clock
Data
+
B8200
RRU
R8840
R8860
E
R8880
A
R8882
BS8700
BS8700 contains
contains two
two separate
separate modules:
modules: baseband
baseband unit
unit and
and
remote
remote radio
radio unit.
unit.
Remote Radio Unit ZXSDR R8840
U
U
Performance
PerformanceIndex
Index
320 mm
Capacity: Maximum[U]: 4 Carriers
Capacity: Maximum[U]: 4 Carriers
370 mm
Output Power: 60W
Output Power: 60W
Receiving Sensitivity: -129.2dBm@dual antennas
Receiving Sensitivity: -129.2dBm@dual antennas
Frequency: 2100M/AWS
Frequency: 2100M/AWS
Typical Power Consumption (TPC):
Typical Power Consumption (TPC):
16.5Kg
0
16
mm
MCPA based, high PA efficiency
Supporting 4 UMTS carriers
Mature commercial application
Smallest size in the industry
Physical
Physical Index
Index
Volume: 370 mm*320 mm*160 mm (H*W*D)
Volume: 370 mm*320 mm*160 mm (H*W*D)
Weight: 16.5 kg
Weight: 16.5 kg
UMTS:
UMTS:100W(S1)/125W(S2)/160W
100W(S1)/125W(S2)/160W(S3)
(S3)
Power Supply: -48V DC, 220V/110V AC
Power Supply: -48V DC, 220V/110V AC
Temperature Range: -40 to +55
Temperature Range: -40 to +55
Protection Class: IP65
Protection Class: IP65
Interface: 2*1.25G CPRI optical interfaces
Interface: 2*1.25G CPRI optical interfaces
Remote Radio Unit ZXSDR R8860E
Performance Index
370 mm
Capacity:
Maximum [G/U]: 6 TRXs/4 Carriers
Maximum [GU] : 4 TRXs+1 Carrier/2 TRXs+2
Carriers
Output Power: 80W
Receiving Sensitivity:
GSM: -113.5dBm@single antenna
UMTS: -129.1dBm@dual antennas
Frequency: 850M/EGSM/900M/1800M/1900M
TPC:
UMTS: 145W (S2, 900M)
GSM: 160W (S6, 900M)/170W (S6, 1800M)
GU : 175W (G_S4+U_S1, 900M)
Power Supply: -48V DC, 220V/110V AC
Temperature Range: -40 to +55
Protection Class: IP65
Interface: 2*1.25G CPRI optical interfaces
20 kg
320 mm
19
mm
MCPA based, high PA efficiency
Supporting GU dual mode
High output power
Physical
Volume:
Index370 mm*320 mm*197 mm
(H*W*D)
Weight: 20 Kg
GU
GU
GU
GU
Remote Radio Unit ZXSDR R8882
15
0
mm
Tx/RxRx RxTx/Rx
480 mm
Capacity:
Capacity:
Maximum
Maximum [G/U]:
[G/U]: 2*4
2*4 TRX/2*2
TRX/2*2 Carriers
Carriers
Maximum
Maximum [GU]
[GU] :: 2*(4TRX+1Carrier)/2*(2TRX+2
2*(4TRX+1Carrier)/2*(2TRX+2 Carr
Carr
Output
Output Power:
Power: 2*60W
2*60W
Sensitivity:
Receiving
Receiving Sensitivity:
GSM:
GSM: -- 113.5dBm@single
113.5dBm@single antenna
antenna
UMTS:
-129.1dBm@dual
antennas
UMTS: -129.1dBm@dual antennas
Frequency:
Frequency: 900M/1800M
900M/1800M
TPC:
TPC:
GSM:
GSM: 305W
305W (S44)
(S44) ;; UMTS:
UMTS: 235W
235W (S11)
(S11)
GU:
GU: 315W
315W (G_S44+U_S11)
(G_S44+U_S11)
Power
Power Supply:
Supply: -48V
-48V DC
DC
Temperature
Temperature Range:
Range: -40
-40 to
to +55
+55
Protection
Class:
IP65
Protection Class: IP65
Interface:
Interface: 2*2.5G
2*2.5G CPRI
CPRI optical
optical interfaces
interfaces
PA PA
23L
Performance
Performance Index
Index
320 mm
MCPA
based , high PA efficiency
Supporting GU dual mode
2T4R, supporting 2 sectors or
2*2 MIMO
Large capacity and easy
expansion
High speed CPRI optical
interface
Physical
Physical Index
Index
Volume:
Volume: 480
480 mm*320
mm*320 mm*150
mm*150 mm
mm (H*W*D)
(H*W*D)
Weight:
Weight: 20
20 Kg
Kg
PA
PA
PA
PA
Diverse Outdoor Distributed BTS Solutions
B8200
Solution I
Solution II
RRU
RRU
BS8906
BBU+RRU Portable Outdoor
BC8910A
BBU+RRU Integrated Outdoor
Solution
Solution
With BS8906 BBU standalone cabinet
With BC910A cabinet
Small & light, for flexible deployment
AC/DC power supply
AC/DC power supply
Built-in/standalone RRU power supply
Using standalone RRU power supply
Maximum 8U reservation for 3rd party
equip
Rapidly Networking Based on Distributed BTS
MicroTCA BBU fitted with 19rack
Small and light, easy for installation,
saving project cost and decreasing
construction period
Compact design, light and small
Flexible networking
50 high-efficient PA to reduce power
consumption
Natural cooling design, 0 dB noise
Flexible power supply: AC/DC or remote
power
IP65 protection class to withstand harsh
environment
Rain forest
Less space required, flexible installation
Snowfield
Rainstorm
Desert
High reliability, suitable for harsh environment
Flexible Networking Capability
Star topology
Chain topology
RRU
RRU
B8200
B8200
STM-1
Supporting 4 levels
E1/T1/GE/FE
RNC/BSC
cascading
Supporting multi RRU in
one cell
Farthest reaching 40 km
with 4 levels
ZTE provides flexible networking for distributed site such as star, chain, loop and hybrid
topology to meet demands from customers.
Benefits
BS8700 is the multi-carrier, dual-mode distributed base station of ZXSDR BTS series. By
adopting advanced MicroTCA platform and SDR technology, BS8700 supports
GPRS/EDGE/E-EDGE and UMTS/HSPA/HSPA+ simultaneously. Its main advantage is
- BBU - Plug-in Design for Shelf, Zero Footprint, Convenient Deployment B8200 adopts
Plug-in design with 19-inch, 2U in height and 8.75 kg in weight. It can be conveniently
SDR Base Station Introduction
Distributed Macro: ZXSDR BS8700
Indoor Macro : ZXSDR BS8800
Outdoor Macro : ZXSDR BS8900A
Outdoor Micro : ZXSDR BS8906
Outdoor Mini : ZXSDR BS8908
Indoor Macro BTS ZXSDR BS8800
GU
GU
Performance
Performance Index
Index
Radio unit:
RSU40/
RSU60E/RSU82
Main
cabine
t
Uplink
Uplink1920
1920CEs/Downlink
CEs/Downlink1920
1920CEs
CEs
Uplink 175Mbps/Downlink 650Mbps
Uplink 175Mbps/Downlink 650Mbps
Base Band
Unit:
B8200
High
reliability
Supporting GU dual mode
Rich
Large capacity
interfaces
All IP structure
Smooth
Interface
Interface Index
Index
GSM:
GSM:60TRX;
60TRX;UMTS:
UMTS:30CSs
30CSs
GU: GSM 36 TRXs + UMTS 12 CSs
GU: GSM 36 TRXs + UMTS 12 CSs
Capacity (with Auxiliary Cabinet):
Capacity (with Auxiliary Cabinet):
evolution
Iub interface:
Iub interface:
88E1/T1
E1/T1(Expandable
(Expandableto
to16)
16)
1 GE optical or 1*GE/FE electrical
1 GE optical or 1*GE/FE electrical
2 STM-1
2 STM-1
Output Power:
Output Power:
900M/1800M:
900M/1800M:80W/2*80W
80W/2*80W
2100M: 60W/2*60W
2100M: 60W/2*60W
Receiving Sensitivity:
Receiving Sensitivity:
GSM:
GSM: -113.5dBm@single
-113.5dBm@singleantenna
antenna
UMTS: -129.2dBm@dual antennas
UMTS: -129.2dBm@dual antennas
TPC:
TPC:
UMTS:
UMTS:380W
380W(RSU40,
(RSU40,S111)
S111)
GSM: 565W (RSU60E, S666)
GSM: 565W (RSU60E, S666)
GU:
GU:640W
640W(RS60E,
(RS60E,G_S444+U_S111)
G_S444+U_S111)
CPRI interface:
CPRI interface:
12
12CPRI
CPRIoptical
opticalinterfaces
interfaces
Physical
Physical Index
Index
Volume and Weight:
Volume and Weight:
Main
Maincabinet:
cabinet: 950
950mm*600
mm*600mm*450
mm*450mm
mm/ /
135
135kg
kg
Auxiliary
Auxiliarycabinet:
cabinet:800
800mm*600
mm*600mm*450
mm*450mm
mm
/115
/115kg
kg
ZXSDR BS8800 Easy to Stack, Easy to
Expand
600 mm
Radio Unit:
RSU40, RSU60E, RSU82
Cable Chute:
Containing wires in rack,
such as fibers or SFP cables
between BBU and RSU.
Power Distribution Module
(PDM):
Passive power distribution
unit
Transmission Device:
1U slot, it can provide builtin transmission or
microwave devices to save
operators investment.
FAN:
Used to perform heat
dissipation for RSU
modules, 6 fans in total
Radio
unit
PDM
Fan
Cable
chute
Ventilati
B8200
on
Auxiliary cabinet
800
mm
450m
m
Main cabinet
950 mm
GU
GU
Less Space Requirement, Fast Deployment
950mm
450mm
ZTE SDR
marco BTS
Wal
l
600mm
600mm
40% Space
saving
600mm
600mm
0.63 vs
1.08m2
Traditional
BTS
600mm
600mm 450mm
600mm
GU
GU
Embedded Indoor Macro BTS ZXSDR
600 mm
BS8800 U120
Performance Index
U
U
Performance Index
1
2
Radio unit:
Capacity:
Capacity:
RSU40
UMTS:
UMTS:12
12CSs
CSs(RF
(RFcapacity
capacitylimitation)
limitation)
Base Band Processing Capability:
Base Band Processing Capability:
Baseband
PDM
Fan Module
950 mm
unit: B8200
UL
UL1920
1920CEs/DL
CEs/DL1920
1920CEs
CEs(384
(384CEs*5
CEs*5BPs)
BPs)
UL 175Mbps/DL 650Mbps
UL 175Mbps/DL 650Mbps
Output Power:
Output Power:
415m
m
Supporting UMTS 12CSs
Zero footprint
Lowest power consumption in macro
BTSs
Interface
Interface Index
Index
60W
60W
Receiving Sensitivity:
Receiving Sensitivity:
-129.2dBm@dual
-129.2dBm@dualantennas
antennas
TPC:
TPC:
UMTS: 380W (RSU40, S111)
UMTS: 380W (RSU40, S111)
Power Supply: -48V DC
Power Supply: -48V DC
Iub interface:
Iub interface:
88E1/T1
E1/T1(Expandable
(Expandableto
to16)
16)
1 GE optical or 1*GE/FE electrical
1 GE optical or 1*GE/FE electrical
2 STM-1
2 STM-1
CPRI interface:
CPRI interface:
12
12CPRI
CPRIoptical
opticalinterfaces
interfaces
Physical
Physical Index
Index
Volume: 620 mm*485 mm*415 mm (H*W*D)
Volume: 620 mm*485 mm*415 mm (H*W*D)
Weight: 75 kg
Weight: 75 kg
SDR Base Station Introduction
Distributed Macro: ZXSDR BS8700
Indoor Macro : ZXSDR BS8800
Outdoor Macro : ZXSDR BS8900A
Outdoor Micro : ZXSDR BS8906
Outdoor Mini : ZXSDR BS8908
Integrated Outdoor MacroPerformance
BTS Index
ZXSDR
BS8900A
Base Band
Unit:
B8200
Radio Unit:
RSU40/
RSU60E/RSU82
Capacity:
GSM: 48TRX; UMTS: 30CSs
GU: GSM 36 TRXs + UMTS 12 CSs
Uplink 1920 CEs/Downlink 1920 CEs
Uplink 175Mbps/Downlink 650Mbps
Output Power:
900M/1800M: 80W/2*80W
2100M: 60W/ 2*60W
Receiving Sensitivity:
GSM: -113.5dBm@single antenna
UMTS: -129.2dBm@dual antennas
TPC :
Complete Style
Large
capacity
Supporting GU dual mode
Rich
All in one outdoor site solution
interfaces
28 hours battery backup
Smooth
evolution
UMTS: 400W (RSU40, S111)
GSM: 565W (RSU60E, S666)
GU: 640W (RS60E, G_S444+U_S111)
Power Supply: -48V DC, 220V AC, 380V AC
Iub interface:
8 E1/T1 (Expandable to 16)
1 GE optical or 1*GE/FE electrical
2 STM-1
Protection class: IP65
CPRI interface:
12 CPRI optical interfaces
Volume : 1600mm*600mm*600mm (Standard sty
Weight: 180 kg (BC8910A+RC8911A, without batt
Interface Index
GU
GU
Physical Index
ZXSDR BS8900A Hardware Structure
Top
cover
Fan
&
Ventilation
Power
system
B8200
LPU
Reserved
space
Heater
Fan &
PDM
Battery
600
mm
16
mm
BC8910A
RSU40, RSU60E, RSU82
Maximum 6 RSUs
AC/DC Power System:
200
mm
6U reserved space can provide built-in
transmission or microwave devices to
save operators investment.
Lightning Protection Unit (LPU):
B8200
Transmission Device:
Radio
unit
Bottom
base
Provide -48V DC power supply and
distribution for BS8900A. It contains
monitor unit, rectifier unit and
distribution unit, being totally 5U in
height.
Base Band Unit:
RC8911A
800 mm
Radio Unit:
800
mm
600
mm
GU
GU
Provide lightning protection for signals
Battery Cabinet:
Maximum capacity: 2*150Ah
ZXSDR BS8900A Cabinets Introduction
GU
GU
ZXSDR BS8900A Component Module
Baseband
cabinet
BC8910A
Radio
cabinet
RC8910A
RC8911A
Battery
cabinet
Dimension of each cabinet
(H*W*D) :
PC8910A
800 mm*600 mm*600 mm
800 mm
600
mm
600
mm
Weight:
BC8910A: 82 kg
RC8910A: 127 kg
RC8911A: 93 kg
PC8910A: 47 kg
Temperature Range:
-40 to +55
Protection: IP55
SDR Base Station Introduction
Distributed Macro: ZXSDR BS8700
Indoor Macro : ZXSDR BS8800
Outdoor Macro : ZXSDR BS8900A
Outdoor Micro : ZXSDR BS8906
Outdoor Mini : ZXSDR BS8908
Integrated Outdoor MicroPerformance
BTS Index
ZXSDR
Performance Index
BS8906
210
320
GU
GU
Processing Capability:
Processing Capability:
mm
GU:
GU:44TRXs
TRXs++1C
1Cor
or22TRXs
TRXs++2Cs
2Cs
GSM: 60 TRXs; UMTS: 30 CSs (with external
GSM: 60 TRXs; UMTS: 30 CSs (with external
RRUs)
RRUs)
mm
Base Band Processing Capability:
Base Band Processing Capability:
650
mm
480
mm
Compact
Standalone
Style
Style
Fast
Supporting
GU dual mode
Supporting GU dual mode
deployment
Strong adaptation to tough
environment
Interface
Interface Index
Index
Iub interface:
Iub interface:
88E1/T1
E1/T1
1 GE optical or 1*GE/FE electrical
1 GE optical or 1*GE/FE electrical
2 STM-1
2 STM-1
CPRI interface:
CPRI interface:
66CPRI
CPRIoptical
opticalinterfaces
interfaces
UL
UL960
960CEs/DL
CEs/DL960
960CEs
CEs
Output Power:
Output Power:
RSU60E: 80W/RSU40: 60W
RSU60E: 80W/RSU40: 60W
Receiving Sensitivity:
Receiving Sensitivity:
GSM:
GSM: -113.5dBm@single
-113.5dBm@singleantenna
antenna
UMTS: -129.2dBm@dual antennas
UMTS: -129.2dBm@dual antennas
Frequency:
Frequency:
GSM:
GSM: 850M/EGSM/900M/1800M/1900MHz
850M/EGSM/900M/1800M/1900MHz
UMTS:
UMTS:
850M/900M/1800M/1900M/2100MHz/AWS
850M/900M/1800M/1900M/2100MHz/AWS
TPC:
TPC:
UMTS:
UMTS:200W
200W(S1,
(S1,RSU40,
RSU40,2100M,
2100M,DC)
DC)
GSM:
240W
(S6,
RSU60E,
900M,
DC)
GSM: 240W (S6, RSU60E, 900M, DC)
GU: 290W (G_S4+U_S1, DC)
GU: 290W (G_S4+U_S1, DC)
Physical
Physical Index
Index
Power Supply: -48V DC
Power Supply: -48V DC
Volume and Weight:
Volume and Weight:
Compact
Compactcabinet:
cabinet: 650
650mm*320
mm*320mm*480
mm*480mm
mm/ /
55
55kg
kg
Standalone
Standalonecabinet:
cabinet:650
650mm*210
mm*210mm*480
mm*480
mm /33 kg
GU
GU
ZXSDR BS8906 Hardware Structure
1
2
3
4
5
6
7
FCE: Fan Control Element
Baseband unit: B8200
PSU: Power System Unit
APM/DPM: AC/DC Protection
Module
LPU: Lightning Protection Unit
Radio unit: RSU40/RSU60E
Fan Array
3
2
5
SA
7
Benefits
1) Small Size, Fast Installation, Adaptive to Outdoor Environment :With High integration, small size and light weight, ZXSDR BS8906 is easy for
SDR Base Station Introduction
Distributed Macro: ZXSDR BS8700
Indoor Macro : ZXSDR BS8800
Outdoor Macro : ZXSDR BS8900A
Outdoor Micro : ZXSDR BS8906
Outdoor Mini : ZXSDR BS8908
G
G
Outdoor Mini BTS ZXSDR BS8908
Performance Index
13 kg
420 mm
Capacity: O6 or S444 (three units in cascading)
Output Power: 40W (GMSK) / 25W (8PSK)
Receive Sensitivity: -112dBm@single antenna
Frequency: 900M/1800M
TPC: GSM: 155W (O2, 900M, DC)
Power Supply: -48V DC, 220V/110V AC
Temperature
10
0
m
m
m
315 m
Optimized
Low power consumptiondesign
Flexible networking
Natural
Range: -40C to +55C
Protection Class: IP65
Transmission: SDH, IP, microwaves & satellite
Physical Index
Volume: 420 mm*315 mm*100 mm (H*W*D)
Weight: 13 kg
cooling
Interface Index
Abis Interface:
4 E1/T1
1 GE/FE optical or 1*GE/FE electrical
Roof top
Tower top
ZTE GU SDR Base Station Products
Summary
Full HSPA
capability
High processing
throughput
IP RAN
networking
ATM/IP dualstacks
Flexible IP
interface
High integration
Large capacity
80W PA and 4
carriers
supported
Low TCO
Fast
deployment
50% HPA
Flexi Indoor and
outdoor coverage
solution
BBU+RRU
solution
Smooth
evolution to
HSPA+ and LTE
Content
ZXSDR Base Station Family Overview
ZXSDR Base Station Introduction
ZXSDR Base Station Highlights
GU Convergence Network Architecture
GSM Base
Station
IP/SDH
Backbone
Independent
GSM RAN
GSM NMS
GSM BSC
UMTS Node B
Independent
UMTS RAN
Remote RRU
IP/SDH
Backbone
UMTS NMS
UMTS RNC
Multi dual mode BBUs
form baseband group
NetNumen
unified NMS
Convergence
RAN
G/U unified NMS
IP/SDH
Backbone
Dual-mode base
staion controller
Multi-mode RRU
Optical fiber
transmission is
adopted unifiedly
Multi-mode base
station
Multimode
RRU
Convergence Network Evolving to LTE
WCDMA Working Mode
W/L Working Mode
WCDMA /LTE RRU
(Same Frequency
band)
RRU
RRU
WCDMA RRU
WCDMA
WCDMA
BBU in SDR platform
Co-platform for multi-mode
Co-Platform for Multi-Mode
Co-shelf, co-rear board, co-power
Co-clock, co-transmission
WCDMA/LTE BBU can be flexibly
configured as per requirements
LTE RRU
(Different
Frequency band)
Feature
LTE RRU
(Different
Frequency band)
LTE
BBU in SDR platform
Advantage
Same architecture for WCDMA/LTE,
Lower TCO
universal hardware
Higher reliability
BBU supports LTE by adding baseband
Faster deployment
board
WCDMA/LTE dual-mode RRU evolution
SDR Solution
Carrier and Power Software Configurable
GSM
GSM
GSM
GSM
GSM
GSM
UMTS
GSM
GSM
GSM
GSM
UMTS
UMTS
GSM
GSM
UMTS
UMTS
UMTS
UMTS
Carrier and Power Software Configurable
Traditional Solution
GSM900
UMTS900
No extra insert loss
Flexible GSM900/UMTS900 Capacity Reframing
Dynamic Power Sharing Enlarging Site Coverage
The sum of each TRX configured maximum output power is bigger than PA maximum output power.
In the area with little traffic, BCCH carrier power configuration can be appropriately added by taking use
of dynamic power, and the remaining power is dynamically real-time shared among all TCH carriers to
enlarge coverage and reduce site quantity.
Static Power Configuration
BCCH
carrier
TCH
carrier A
User A
TCH
carrier B
Dynamic
Power Sharing
User A
30w
15w
20w
BCCH
carrier
TCH
carrier A
40w
5w
TCH
carrier B
30w
BCCH
carrier
TCH
carrier A
TCH
carrier B
20w
User B The sum of each TRX maximum transmission power is no
bigger than PA maximum output power
The sum of each TRX maximum
transmission power(100W) is bigger
than PA maximum output power
(80W).
30w
30w
40w
15w
20w
30w
30w
As user moves, each TRX transmission
power dynamically adjusts.
User B
30w
All IP-based Network Improving Transmission
All IP-based network is the trend for
Efficiency
mobile communication.
TC Pool
SDR Base
Station
RNC
IP A
Flex A
IP Ater
MGW2
IP Abis
MSC Server
MGW1
IP Gb
Flex Gb
SDR
Base
Station
SGSN1
SGSN2
GGSN
All IP-based network has better transmission efficiency.
GE or IP over E1
TDM E1
transmission
All IP baseband
processing unit
15 TRX/E1
Transmission
efficiency
Mute frame and IP
IP over FE
23 TRX/2Mbps
increases by
head compression
IP over E1
28 TRX/2Mbps
87%
One Logical Cell with Multi RRU Technology
BBU + RRU remote networking suits coverage scenes such as roads, bridges,
villages along the river and so on.
Cell A
Cell A
Cell A
Cell A
Cell A
Cell A
Multi-RRU co-cell, improving wireless utilization
Split cabinet, only BBU installed
One logical Cell with Multi RRU dramatically reduces inter-cell
switch, and improves wireless utilization.
Measured UL datarate (Kpbs) of high speed railway scenario
Remote expansion
Software configuration
Cell A
Cell A
Multi RRU and AFC disable
Only AFC enable
Only Multi RRU enable
Multi RRU and AFC enable
BCCH carrier power unchanged
Increasing TCH carrier, using
reserved frequency point to absorb
traffic
Not changing existing network
frequency planning
SDR-Based Network Effectively Reducing Energy
Consumption
Antenna-Close Installation Avoiding Feeder
Highly Efficient PA Improving Overall
Efficiency
Typical consumption for S444
1250W
Power consumption
descreased by 42%
725W
PA module adoptes
Doherty, DPD and
multi-carrier PA,
increasing overall
efficiency to over
20%.
Traditional Base
Station
Multi-carrier Base
Station
Loss
RRU
RRU RRU is installed close to
BBU
antenna, saving feeder loss.
For the same coverage
requirement, it reduces RF
output power, hence lowering
power consumption.
Intelligent Software Power Saving
Networking Mode Saving Energy
Technology
Consumption
It supports some latest energy saving technologies such as
intelligent voltage adjustment, carrier priority control and
RRU module shutdown.
T
R
X
1
T
R
X
2
T
R
X
3
T
R
X
4
T
R
X
5
RRU adopts natual cooling system, BBU features in low
power consumption and concentration which requires less
equipment room and greatly reduces corollary equipments
and air-conditioners power consumption.
T
R
X
6
Multi-carrier PA
Constructing network by using SDR-based Base Station averagely saves single sites energy by over 40%.
Diverse Networking, tridimensional Coverage
Coverage Challenge in
Dense Urban
Complex environment of buildings
Bind area in buildings
Frequent handovers
Macro site and distributed site combined
together
Particular coverage for special area
1-6 cells deployment in single site
Tridimensional Coverage by ZTE
SDR
Rapid Installation and Simple Maintenance
RRU flexible installation
Macro base station without back board
Installation
by the
on
On the pole
the wall
wall
All
modules operation
at front, easy maintenance
BBU saves space greatly
19 inch width, 2U height.
On
transmission rack or
macro base station
Directly on the wall
One
person
Modularized designation for many application
BS8900 modularized designation,
flexible subcabinet configuration
Integrated cabinet in suburb
Horizontal
installation in weight
limited area