Security Level:
INSTALACION NODO B
www.huawei.com
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential
Hardware Installation
Section 1 BBU3900 Installation
Section 2 RRU 3801C Installation
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2
Installing BBU3900 in the 19-inch
cabinet
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3
Installing BBU3900 in the 19-inch
rack
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4
BBU3900 Panel
WMPT WCDMA Main Processing and Transmission Unit
WBBPa WCDMA Baseband Process unit Type A
UBFA Universal BBU Fan Unit Type A (2U)
UELP Universal E1/T1 Lighting Protection unit
UPEU Universal Power and Environment Interface Unit
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5
The -48V DC Power Cable
Installation
• DC power cable introduction :A1 Azul (-48V) and A3 Negro (0 voltios)
Al breaker (cable
azul)
A barra de cobre del PDU (cable negro)
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6
Installing the CPRI module
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7
Cabling route indoor
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8
Cabling route outdoor
Cableado horizontal con
corrugado 1”” (fibra y
energía RRU) 1 x sector
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10
Uso de canaletas verticales
• Los cables que llegan a la PDU,BBU bajarán por una
canaleta que será instalada pegado al rack existente de
Nextel.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11
Hardware Installation
Section 2 RRU 3801C Installation
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12
RRU3801C Installation
Installing the mounting bracket on the pole
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13
RRU3801C Installation
• Main components of the RRU3801C
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14
All RRU must be powered on before the
installation.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in ordinary mode
Step1: Use the hole labeled 40W RRU Ordinary in the
attachment plate, as shown in Figure
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in ordinary mode
Step2: Use three M6 x 16 screws to secure the
attachment plate on the module, as shown in Figure
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in ordinary mode
Step3: Flip open the flaps on both sides of the mounting bracket. Then
hitch the module onto the mounting bracket by fitting the tabs on the
attachment plate into the anchor slots, as shown in Figure
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in ordinary mode
Step4: Lead two M6 x 16 screws through the holes in the bottom of the module.
Then secure the module on the mounting bracket, as shown in Figure
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in reverse mode
Step1: Remove the locking piece by unfastening the two M3 x 8 screws from
the bottom of the module
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in reverse mode
Step2: Use the two M3 x 8 screws to install the locking piece on the other side
of the module
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in reverse mode
Step3: Use the hole labeled 40W RRU Reverse in the attachment plate
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in reverse mode
Step4: Use three M6 x 16 screws to secure the attachment plate on the module
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 23
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in reverse mode
Step5: Flip open the flaps on both sides of the mounting bracket. Then hitch
the module onto the mounting bracket by fitting the tabs on the attachment
plate into the anchor slots
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 24
RRU3801C Installation
• Installing the module on the mounting bracket
Installing the module in reverse mode
Step6: Lead two M6 x 16 screws through the holes in the bottom of the module.
Then secure the module on the mounting bracket
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 25
The screw with all the components
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 26
RRU3801C Installation
• Installing the Bracket-Mounted 40 W Module on a Pole
• Top view
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27
Posición de la
RRU
Por lo general la RRU
estará debajo de la
antena sectorial.
Cuando por motivo de
facilidad de
mantenimiento se puede
colocar la RRU encima
de la sectorial. Ej:
antenas adosadas en las
paredes de edificios
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 28
RRU3801C Cables
• DC Power Cable
• DC power cable leads external –48 V power into RRU
• One end is a round water-proof connector. The other end is naked.
1 2
4 3 5
7 6 8
9
El cable 0 volt(negro) va a la
barra de cobre del PDU
El cable -48volt(cable azul) va al
breaker del PDU
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 29
RRU3801C Cables
• RF Jumper
• RF jumper is for inputting and outputting RF signals.
• RF jumper should be marked with label to indicate the
which section it is
(1)
(1) DIN male connector
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 30
RRU3801C Cables
• Optical Fiber Fiber connection in RRU side
Fiber connection in BBU side
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 31
Fibra Optica:Consideraciones
Mucho cuidado al trabajarlas:
Desenrrollamiento
Subida de fibra
Conexiones
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 32
CPRI Installation in cabling cavity of
RRU3801c
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 33
Waterproof plugs of RRU
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 34
RRU3801C Cables
• Protection Grounding Cable (RRU side)
• Connect the OT terminal at one end of the
PGND cable to the grounding bolt on the Good
RRU3801C
waterproof
protection
Grounding
cable
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 35
Optical cable routing
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 36
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 37
Routing cables for RRU3801C
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 38
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 39
Waterproofing instructions
4) The waterproofing should be done according to the following
instructions:
a. One layer of insulation tape from bottom to top.
b. Three layers of waterproof tape starting from bottom to top.
c. Three layers of insulation tape starting from bottom to top.
d. Zip-ties must be placed at the bottom and top of the waterproof cover to
avoid water from removing the ends of it.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 40
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 41
Feeder labeling and color ring label
Sector 0: ROJO Sector
The fiber between
Power cable for RRU
Jumpers
BBU and RRU Diversity (Antenna
Main
System 2)
Sector 1: AMARILLO 0 Red, a label Red, a label Red, two labels Red, a label
1 Yellow, a label Yellow, a label Yellow, two labels Yellow, a label
Sector 2: AZUL 2 Blue, a label Blue, one label Blue, two labels Blue, one label
3 Purple, a label Purple, a label Purple, two labels Purple, a label
Main:2 Cintas 4 Orange, a label Orange, a label Orange, two labels Orange, a label
5 Green, a label Green, a label Green, two labels Green, a label
Diversidad:1 Cinta
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 42
BBU instalada
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 43
Instalación de antena
• Identificación de antenas:
Primer Sector : 0
Segundo Sector:1
Tercer Sector: 2
• Orientación de antenas
Cada antena orientada según azimuth(ángulo respecto a 0
grados-Norte)
Sentido horario empezando de Norte
Medir ROE con el jumper conectado a la antena.
• ROE < 1.3
• Mandar gráficas
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 44
Instalación de antenas
• Instalación jumper
En torre:Fijar en ambos extremos del jumper a la altura de los
soportes de la RRU con clamps a la torre.
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 45
Thank you