FROM SAMPLING LINES OF STEAM -WATER
CYCLE
BY DILIP KUMAR
NTPC Ltd.
SAMPLING LINES OF STEAM WATER CYCLE
1. DM MAKEUP WATER
2. CONDENSATE WATER
3. CPU OUTLET WATER
4. FEED WATER
5. BOILER DRUM WATER
6. SATURATED STEAM WATER
7. MAIN STEAM WATER
8. DEAERATOR OUTLET WATER
DM WATER REDUCTION FROM SAMPLING LINES
Each sampling line having average flow 0.5
liters/min
Total water reduction from steam water
cycle/unit/min is 8 × 0.5 = 4.0 liters
Total water reduction / unit/hour = 60 × 4
=240 L
Total water reduction / unit/day = 240 × 24
=5760 L
Total water reduction / unit/month = 5760 ×
30 =172800 L
Total water reduction /month from stage-II =
172800 × 3 =518400 L =518.400 M3
Total water reduction /year from stage-II =
518.400 × 12 =6220.8 m3
DM WATER WASTE FROM SWAS STAGE-II
TOTAL SAMPLING LINES AT SWAS PANEL = 27
TOTAL SAMPLING LINES EXCEPT BOILER & CONDENSE
COOLING WATER= 21
No. OF LOCAL SAMPLING LINES=12
TOTAL SAMPLING LINES= 33
AVERAGE FLOW OF EACH SAMPLING LINES=0.5 L/MIN
TOTAL DM WATER WASTAGE =
0.5×33×60×24×30=712800L/MONTH
= 712.8 M3/MONTH
DM WATER WASTE FROM SWAS STAGE-I
TOTAL SAMPLING LINES AT SWAS PANEL = 29
TOTAL SAMPLING LINES EXCEPT BOILER = 25
No. OF LOCAL SAMPLING LINES=12
TOTAL SAMPLING LINES= 37
AVERAGE FLOW OF EACH SAMPLING LINES=0.5
L/MIN
TOTAL DM WATER WASTAGE =
0.5×37×60×24×30=799200 L/MONTH
= 799.2 M3/MONTH
DM WATER WASTE FROM SWAS STAGE-I&II
TOTAL DM WATER WASTAGE FROM STAGE-I
= 0.5×37×60×24×30=799200 L/MONTH
= 799.2 M3/MONTH
TOTAL DM WATER WASTAGE FROM STAGE-II
=0.5×33×60×24×30=712800L/MONTH
= 712.8 M3/MONTH
TOTAL AVERAGE DM WATER WASTE FROM KhSTPS
= 1512.0 M3/MONTH
ADVANTAGE OF CONSERVATION OF DM WATER
1.LOW AMMONIA CONSUMPTION DURING FEED OF CONSERVED DM
WATER
2.REDUCTION IN HCl CONSUMPTION (3.72 M3/MONTH)
3.REDUCTION IN NaOH CONSUMPTION (615 Kg/MONTH)
4.REDUCTION IN EFFLUENT FROM DM PLANT DURING
REGENERATION OF DM STREAMS (750M3/MONTH)
5.REDUCTION OF MAIN PLANT EFFLUENTS (1500M3/MONTH)
6.TIME SAVING IN THE REGENERATION AND SERVICE (24 HOURS)

More Related Content

PPTX
Power plant chemistry
PPTX
POWER PLANT CHEMISTRY( WATER TREATMENT FOR BOILERS)
PPTX
demineralization
PPTX
Water analysis from_intake_well_to_boiler_drum-n
PPTX
DM water production through Reverse Osmosis(RO)
PPTX
Basic Thermal Power Plant Chemistry, for Operational Staff.
PDF
Chemical Treatment For Cooling Water
Power plant chemistry
POWER PLANT CHEMISTRY( WATER TREATMENT FOR BOILERS)
demineralization
Water analysis from_intake_well_to_boiler_drum-n
DM water production through Reverse Osmosis(RO)
Basic Thermal Power Plant Chemistry, for Operational Staff.
Chemical Treatment For Cooling Water

What's hot (20)

PPT
POWER PLANT CHEMISTRY
PPTX
Boiler Cycle water chemistry by Sudhanshu Dash
PPT
Water treatment by demineralisation
PPT
Power Plant Chemistry FEED WATER TREATMENT
PPTX
Boiler feedwater
DOCX
Dm plant
PDF
HANDBOOK ON POWER PLANT CHEMISTRY.pdf
PPT
Reverse osmosis
PPSX
Power Plant Water Treatment
PDF
Power plant chemistry by ramesh
PPTX
Cooling Water Treatment
PDF
Water and steam chemistry deposits and corrosion-
PDF
S k-sharma-water-chemistry-in-thermal-power-plants
PPTX
Water treatment in Power plants
PDF
Conductivity in power plants
PPTX
AFTER CATION CONDUCTIVITY
PDF
Boiler Water Treatment
PPT
Steam water analysis system
PDF
Chapter12 coagulation
POWER PLANT CHEMISTRY
Boiler Cycle water chemistry by Sudhanshu Dash
Water treatment by demineralisation
Power Plant Chemistry FEED WATER TREATMENT
Boiler feedwater
Dm plant
HANDBOOK ON POWER PLANT CHEMISTRY.pdf
Reverse osmosis
Power Plant Water Treatment
Power plant chemistry by ramesh
Cooling Water Treatment
Water and steam chemistry deposits and corrosion-
S k-sharma-water-chemistry-in-thermal-power-plants
Water treatment in Power plants
Conductivity in power plants
AFTER CATION CONDUCTIVITY
Boiler Water Treatment
Steam water analysis system
Chapter12 coagulation
Ad

Viewers also liked (20)

PPTX
Generator protection
PPTX
Ashwani kumar
PPT
8 steps-to-ensure-proper-lockout-tagout
PPS
Loto.ppt
PPT
Generator protection by bhushan kumbhalkar
PPTX
Water treatment process by RO UF
PPTX
progress in civil engg by aatif sadiq
PDF
Generator Protection By - Er Rahul Sharma
PPTX
De-mineralization of Water
PDF
HV Circuit Breaker Testing
PPT
BASIC CIVIL ENGINEERING
PPT
Vacuum circuit breaker
PDF
Practical Arc Flash Protection for Electrical Safety Engineers and Technicians
PPS
Reverse osmosis (ro) plant an overview-saeed
PPTX
Reverse Osmosis System Basics
PPT
Industrial safetY of height works
PPTX
DIESEL LOCOMOTIVE WORKS, VARANASI, FOR CIVIL ENGG.
PPT
ABCB(air blast circuit breaker)
PPTX
PPT
The Theory of Reverse Osmosis (RO)
Generator protection
Ashwani kumar
8 steps-to-ensure-proper-lockout-tagout
Loto.ppt
Generator protection by bhushan kumbhalkar
Water treatment process by RO UF
progress in civil engg by aatif sadiq
Generator Protection By - Er Rahul Sharma
De-mineralization of Water
HV Circuit Breaker Testing
BASIC CIVIL ENGINEERING
Vacuum circuit breaker
Practical Arc Flash Protection for Electrical Safety Engineers and Technicians
Reverse osmosis (ro) plant an overview-saeed
Reverse Osmosis System Basics
Industrial safetY of height works
DIESEL LOCOMOTIVE WORKS, VARANASI, FOR CIVIL ENGG.
ABCB(air blast circuit breaker)
The Theory of Reverse Osmosis (RO)
Ad

More from Dilip Kumar (7)

PPTX
U#3 BOILER CHEMICAL CLEANING.
PPTX
COLLODAL SILICA JULY2016
PPTX
SIGNIFICANCE OF STEAM WATER PARAMETERS
PPTX
Dm water conservation
PPTX
Pretreatment of water
PPTX
CHEMICAL SAFETY
PPTX
PRETREATMENT OF WATER
U#3 BOILER CHEMICAL CLEANING.
COLLODAL SILICA JULY2016
SIGNIFICANCE OF STEAM WATER PARAMETERS
Dm water conservation
Pretreatment of water
CHEMICAL SAFETY
PRETREATMENT OF WATER

DM water conservation

  • 1. FROM SAMPLING LINES OF STEAM -WATER CYCLE BY DILIP KUMAR NTPC Ltd.
  • 2. SAMPLING LINES OF STEAM WATER CYCLE 1. DM MAKEUP WATER 2. CONDENSATE WATER 3. CPU OUTLET WATER 4. FEED WATER 5. BOILER DRUM WATER 6. SATURATED STEAM WATER 7. MAIN STEAM WATER 8. DEAERATOR OUTLET WATER
  • 3. DM WATER REDUCTION FROM SAMPLING LINES Each sampling line having average flow 0.5 liters/min Total water reduction from steam water cycle/unit/min is 8 × 0.5 = 4.0 liters Total water reduction / unit/hour = 60 × 4 =240 L Total water reduction / unit/day = 240 × 24 =5760 L Total water reduction / unit/month = 5760 × 30 =172800 L Total water reduction /month from stage-II = 172800 × 3 =518400 L =518.400 M3 Total water reduction /year from stage-II = 518.400 × 12 =6220.8 m3
  • 4. DM WATER WASTE FROM SWAS STAGE-II TOTAL SAMPLING LINES AT SWAS PANEL = 27 TOTAL SAMPLING LINES EXCEPT BOILER & CONDENSE COOLING WATER= 21 No. OF LOCAL SAMPLING LINES=12 TOTAL SAMPLING LINES= 33 AVERAGE FLOW OF EACH SAMPLING LINES=0.5 L/MIN TOTAL DM WATER WASTAGE = 0.5×33×60×24×30=712800L/MONTH = 712.8 M3/MONTH
  • 5. DM WATER WASTE FROM SWAS STAGE-I TOTAL SAMPLING LINES AT SWAS PANEL = 29 TOTAL SAMPLING LINES EXCEPT BOILER = 25 No. OF LOCAL SAMPLING LINES=12 TOTAL SAMPLING LINES= 37 AVERAGE FLOW OF EACH SAMPLING LINES=0.5 L/MIN TOTAL DM WATER WASTAGE = 0.5×37×60×24×30=799200 L/MONTH = 799.2 M3/MONTH
  • 6. DM WATER WASTE FROM SWAS STAGE-I&II TOTAL DM WATER WASTAGE FROM STAGE-I = 0.5×37×60×24×30=799200 L/MONTH = 799.2 M3/MONTH TOTAL DM WATER WASTAGE FROM STAGE-II =0.5×33×60×24×30=712800L/MONTH = 712.8 M3/MONTH TOTAL AVERAGE DM WATER WASTE FROM KhSTPS = 1512.0 M3/MONTH
  • 7. ADVANTAGE OF CONSERVATION OF DM WATER 1.LOW AMMONIA CONSUMPTION DURING FEED OF CONSERVED DM WATER 2.REDUCTION IN HCl CONSUMPTION (3.72 M3/MONTH) 3.REDUCTION IN NaOH CONSUMPTION (615 Kg/MONTH) 4.REDUCTION IN EFFLUENT FROM DM PLANT DURING REGENERATION OF DM STREAMS (750M3/MONTH) 5.REDUCTION OF MAIN PLANT EFFLUENTS (1500M3/MONTH) 6.TIME SAVING IN THE REGENERATION AND SERVICE (24 HOURS)