DULY FED INDUCTION
GENERATOR
PREPARED BY:-
SONU KUMAR BAIRWA
• A Doubly Fed Induction generator as its name
suggests is a 3 phase induction generator where
both the rotor and stator windings are fed with 3
phase AC signal.
• It consists of multi phase windings placed on
both the rotor and stator bodies. It also consists
of a multiphase slip ring assembly to transfer
power to the rotor.
• It is typically used to generate electricity in wind
turbine generators.
Double Fed Induction Generator
• The DFIG consists of a 3 phase wound rotor and a 3
phase wound stator. The rotor is fed with a 3 phase
AC signal which induces an ac current in the rotor
windings.
• As the wind turbines rotate, they exert mechanical
force on the rotor, causing it to rotate.
• As the rotor rotates the magnetic field produced due
to the ac current also rotates at a speed proportional
to the frequency of the ac signal applied to the rotor
windings.
• As a result a constantly rotating magnetic flux
passes through the stator windings which cause
induction of ac current in the stator winding.
Thus the speed of rotation of the stator magnetic
field depends on the rotor speed as well as the
frequency of the ac current fed to the rotor
windings.
• The basic requirement for the electricity
generation using wind energy is to produce ac
signal of constant frequency irrespective of the
wind speed. In other words the frequency of the
ac signal generated across the stator should be
constant irrespective of the rotor speed
variations.
• To achieve this, the frequency of ac signal
applied to the rotor windings need to be
adjusted.
A wind power generation system using double fed induction generator
• The frequency of the rotor ac signal increases as
the rotor speed decreases and is of positive
polarity and vice versa.
• Thus the frequency of rotor signal should be
adjusted such the stator signal frequency is
equal to the network line frequency.
• This is done by adjusting the phase sequence of
the rotor windings such that the rotor magnetic
field is in the same direction as the generator
rotor (in case of decreasing rotor speed) or in
opposite direction as the generator rotor (in case
of increasing rotor speed).
• The whole system consists of two back to back
converters – a machine side converter and a grid
side converter, connected in the feedback loop of the
system.
• The machine side converter is used to control the
active and reactive powers by controlling the d-q
components of the rotor and also torque and speed
of the machine.
• The grid side converter is used to maintain a
constant dc link voltage and ensures the unity power
factor operation by making the reactive power
drawn from the utility grid to zero.
• A capacitor is connected between the two converters
such that it acts as an energy storage unit.
• . This back to back arrangement provides a fixed
voltage fixed frequency output irrespective of the
variable frequency, variable voltage output of the
generator.
• Other applications of the induction generators
are fly-wheel energy storage systems, pumped
storage power plants, power converters feeding a
railway power grid from public grid where the
frequency is fixed.
SCHEME FOR WIND ENERGY
GENERATION BY USING DFIG
• A Wind Turbine: The wind turbine is typically a fan
consisting of 3 blades which rotate when wind strikes it.
The rotation axis should be aligned with the wind
direction.
• Gear Box: It is a high precision mechanical system
which uses a mechanical method to convert energy from
one device to another.
• Double Fed Induction Generator: It is an
electrical generator used to convert mechanical
energy to electrical energy which is in form of
variable frequency.
• Grid Side Converter: It is an AC-DC
converter circuit which is used to provide a
regulated DC voltage to the inverter. It is used
maintain a constant DC link voltage.
• Rotor Side Converter: It is a DC-AC inverter
which is used to provide controlled AC voltage to
the rotor.
REASON FOR USE OF DFIG IN WIND
GENERATION
• Constant frequency output signal to the grid
irrespective of the variable rotor speed.
• Low power rating required for the power electronic
devices and hence low cost of control system.
• Power factor is controlled, i.e. maintained at unity.
• Electric power generation at low wind speed.
• Power electronic converter has to handle the
fraction of the total load i.e.,20-30% and also cost of
this converter is low than in case of the other types
of generators.
Duly fed induction generator

More Related Content

PPTX
Synchronous machines
PPTX
electrical machines
PDF
Doubly fed-induction-generator
PPTX
PDF
Synchronous machines
PDF
Synchronous machines
PPTX
induction generator
PPTX
Swing equation
Synchronous machines
electrical machines
Doubly fed-induction-generator
Synchronous machines
Synchronous machines
induction generator
Swing equation

What's hot (20)

PPTX
Power system protection
PPTX
Control of electric drive
PDF
Synchronous generators
PDF
synchronous generators
PDF
Electromagnetic relay
PPTX
Synchronous machine
PPTX
Grid Integration issues in wind
PPTX
Introduction to Transient Disturbances of power system and its types
PPTX
Design of transformer: Output Equation
PDF
Power System Stabilizer (PSS) for generator
PDF
Breaking,Types of Electrical Braking system, Regenerative Braking, Plugging ...
PPTX
Power System Stabilizer
PDF
Electrical machines 2 AC Machines
PPTX
Permanent magnet synchronousgenerator
PDF
Power system fault analysis ppt
PDF
PWM inverter fed VFD
PPT
Tripping and control of impulse generators
PDF
Speed control of dc motors
PPTX
Power Quality Measurement Devices & Monotoring
PPTX
Facts lectures-2014
Power system protection
Control of electric drive
Synchronous generators
synchronous generators
Electromagnetic relay
Synchronous machine
Grid Integration issues in wind
Introduction to Transient Disturbances of power system and its types
Design of transformer: Output Equation
Power System Stabilizer (PSS) for generator
Breaking,Types of Electrical Braking system, Regenerative Braking, Plugging ...
Power System Stabilizer
Electrical machines 2 AC Machines
Permanent magnet synchronousgenerator
Power system fault analysis ppt
PWM inverter fed VFD
Tripping and control of impulse generators
Speed control of dc motors
Power Quality Measurement Devices & Monotoring
Facts lectures-2014
Ad

Similar to Duly fed induction generator (20)

PPTX
Doube fed induction generator whole .pptx
PDF
IRJET - Wind Energy Conversion System with DGIF
PDF
Study of DFIG Connected to Grid using Wind Energy System
PDF
doubley fed induction motor
PDF
Performance of Doubly-Fed Induction Generator by changing various system para...
PDF
Stability check of doubly fed induction generator (DFIG) micro grid power system
PDF
Grid Connected Doubly Fed Induction Generator By Wind Power Application
PDF
The Relevance of Doubly – Fed Induction Generator (DFIG) in Modelling and Sim...
PDF
Load Frequency Control of DFIG-isolated and Grid Connected Mode
PDF
A Frame Work for Control of Gird Connected Wind Power Using Two Layer Control
PDF
T25102106
PDF
Review on stability analysis of grid connected wind power generating system1
PDF
Review on stability analysis of grid connected wind power generating system1
PPTX
dfigppt-221029141308-fdd782dd.pptx
PDF
DFIG_report
PDF
Cm25524527
PDF
IRJET- Decoupled Control Technique of DFIG with Dual PWM Converters for Wind ...
PDF
Mh3621022106
PDF
Commanding Doubly-Fed Induction Generator (DFIG) to Decouple Active and React...
PDF
D03701028034
Doube fed induction generator whole .pptx
IRJET - Wind Energy Conversion System with DGIF
Study of DFIG Connected to Grid using Wind Energy System
doubley fed induction motor
Performance of Doubly-Fed Induction Generator by changing various system para...
Stability check of doubly fed induction generator (DFIG) micro grid power system
Grid Connected Doubly Fed Induction Generator By Wind Power Application
The Relevance of Doubly – Fed Induction Generator (DFIG) in Modelling and Sim...
Load Frequency Control of DFIG-isolated and Grid Connected Mode
A Frame Work for Control of Gird Connected Wind Power Using Two Layer Control
T25102106
Review on stability analysis of grid connected wind power generating system1
Review on stability analysis of grid connected wind power generating system1
dfigppt-221029141308-fdd782dd.pptx
DFIG_report
Cm25524527
IRJET- Decoupled Control Technique of DFIG with Dual PWM Converters for Wind ...
Mh3621022106
Commanding Doubly-Fed Induction Generator (DFIG) to Decouple Active and React...
D03701028034
Ad

More from SonuKumarBairwa (20)

PPTX
Basics of AC transmission
PPTX
Solar panel i v characteristics
PPTX
Parabolic trough
PPTX
Solar thermal technologies
PPTX
Estimation of solar energy
PPTX
Earth sun angle &observer sun angle
PPTX
Solar radiation spectra
PPTX
Converter control in wind turbine
PPTX
B-H curve of magnetic materials
PPTX
Power electronic converter in wind turbine.1.
PPTX
influence of highly permeable material on magnetic lines
PPTX
Power electronic converter in wind turbine
PPTX
AMPERE CIRCUITRY LAW
PPTX
Review of wind turbine technology
PPTX
Reluctance and inductance
PPTX
Review of magnetic circuits
PPTX
Wind speed probability distribution
PPTX
Induction generator
PPTX
Fixed and variable speed turbine
PPTX
Wind energy statistics
Basics of AC transmission
Solar panel i v characteristics
Parabolic trough
Solar thermal technologies
Estimation of solar energy
Earth sun angle &observer sun angle
Solar radiation spectra
Converter control in wind turbine
B-H curve of magnetic materials
Power electronic converter in wind turbine.1.
influence of highly permeable material on magnetic lines
Power electronic converter in wind turbine
AMPERE CIRCUITRY LAW
Review of wind turbine technology
Reluctance and inductance
Review of magnetic circuits
Wind speed probability distribution
Induction generator
Fixed and variable speed turbine
Wind energy statistics

Recently uploaded (20)

PPTX
CNS - Unit 1 (Introduction To Computer Networks) - PPT (2).pptx
PDF
Unit1 - AIML Chapter 1 concept and ethics
PPTX
Micro1New.ppt.pptx the mai themes of micfrobiology
PDF
MLpara ingenieira CIVIL, meca Y AMBIENTAL
PPTX
WN UNIT-II CH4_MKaruna_BapatlaEngineeringCollege.pptx
PPTX
chapter 1.pptx dotnet technology introduction
PPTX
BBOC407 BIOLOGY FOR ENGINEERS (CS) - MODULE 1 PART 1.pptx
PPTX
Agentic Artificial Intelligence (Agentic AI).pptx
DOCX
An investigation of the use of recycled crumb rubber as a partial replacement...
PDF
Micro 3 New.ppt.pdf tools the laboratory the method
PPTX
Wireless sensor networks (WSN) SRM unit 2
PPT
UNIT-I Machine Learning Essentials for 2nd years
PPTX
Solar energy pdf of gitam songa hemant k
PDF
MACCAFERRY GUIA GAVIONES TERRAPLENES EN ESPAÑOL
PDF
Principles of operation, construction, theory, advantages and disadvantages, ...
PDF
UEFA_Carbon_Footprint_Calculator_Methology_2.0.pdf
PDF
Micro 4 New.ppt.pdf a servay of cells and microorganism
PPTX
CS6006 - CLOUD COMPUTING - Module - 1.pptx
PPTX
Module1.pptxrjkeieuekwkwoowkemehehehrjrjrj
PDF
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
CNS - Unit 1 (Introduction To Computer Networks) - PPT (2).pptx
Unit1 - AIML Chapter 1 concept and ethics
Micro1New.ppt.pptx the mai themes of micfrobiology
MLpara ingenieira CIVIL, meca Y AMBIENTAL
WN UNIT-II CH4_MKaruna_BapatlaEngineeringCollege.pptx
chapter 1.pptx dotnet technology introduction
BBOC407 BIOLOGY FOR ENGINEERS (CS) - MODULE 1 PART 1.pptx
Agentic Artificial Intelligence (Agentic AI).pptx
An investigation of the use of recycled crumb rubber as a partial replacement...
Micro 3 New.ppt.pdf tools the laboratory the method
Wireless sensor networks (WSN) SRM unit 2
UNIT-I Machine Learning Essentials for 2nd years
Solar energy pdf of gitam songa hemant k
MACCAFERRY GUIA GAVIONES TERRAPLENES EN ESPAÑOL
Principles of operation, construction, theory, advantages and disadvantages, ...
UEFA_Carbon_Footprint_Calculator_Methology_2.0.pdf
Micro 4 New.ppt.pdf a servay of cells and microorganism
CS6006 - CLOUD COMPUTING - Module - 1.pptx
Module1.pptxrjkeieuekwkwoowkemehehehrjrjrj
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf

Duly fed induction generator

  • 1. DULY FED INDUCTION GENERATOR PREPARED BY:- SONU KUMAR BAIRWA
  • 2. • A Doubly Fed Induction generator as its name suggests is a 3 phase induction generator where both the rotor and stator windings are fed with 3 phase AC signal. • It consists of multi phase windings placed on both the rotor and stator bodies. It also consists of a multiphase slip ring assembly to transfer power to the rotor. • It is typically used to generate electricity in wind turbine generators.
  • 3. Double Fed Induction Generator • The DFIG consists of a 3 phase wound rotor and a 3 phase wound stator. The rotor is fed with a 3 phase AC signal which induces an ac current in the rotor windings. • As the wind turbines rotate, they exert mechanical force on the rotor, causing it to rotate. • As the rotor rotates the magnetic field produced due to the ac current also rotates at a speed proportional to the frequency of the ac signal applied to the rotor windings.
  • 4. • As a result a constantly rotating magnetic flux passes through the stator windings which cause induction of ac current in the stator winding. Thus the speed of rotation of the stator magnetic field depends on the rotor speed as well as the frequency of the ac current fed to the rotor windings. • The basic requirement for the electricity generation using wind energy is to produce ac signal of constant frequency irrespective of the wind speed. In other words the frequency of the ac signal generated across the stator should be constant irrespective of the rotor speed variations.
  • 5. • To achieve this, the frequency of ac signal applied to the rotor windings need to be adjusted. A wind power generation system using double fed induction generator
  • 6. • The frequency of the rotor ac signal increases as the rotor speed decreases and is of positive polarity and vice versa. • Thus the frequency of rotor signal should be adjusted such the stator signal frequency is equal to the network line frequency. • This is done by adjusting the phase sequence of the rotor windings such that the rotor magnetic field is in the same direction as the generator rotor (in case of decreasing rotor speed) or in opposite direction as the generator rotor (in case of increasing rotor speed).
  • 7. • The whole system consists of two back to back converters – a machine side converter and a grid side converter, connected in the feedback loop of the system. • The machine side converter is used to control the active and reactive powers by controlling the d-q components of the rotor and also torque and speed of the machine. • The grid side converter is used to maintain a constant dc link voltage and ensures the unity power factor operation by making the reactive power drawn from the utility grid to zero. • A capacitor is connected between the two converters such that it acts as an energy storage unit.
  • 8. • . This back to back arrangement provides a fixed voltage fixed frequency output irrespective of the variable frequency, variable voltage output of the generator. • Other applications of the induction generators are fly-wheel energy storage systems, pumped storage power plants, power converters feeding a railway power grid from public grid where the frequency is fixed.
  • 9. SCHEME FOR WIND ENERGY GENERATION BY USING DFIG • A Wind Turbine: The wind turbine is typically a fan consisting of 3 blades which rotate when wind strikes it. The rotation axis should be aligned with the wind direction. • Gear Box: It is a high precision mechanical system which uses a mechanical method to convert energy from one device to another.
  • 10. • Double Fed Induction Generator: It is an electrical generator used to convert mechanical energy to electrical energy which is in form of variable frequency. • Grid Side Converter: It is an AC-DC converter circuit which is used to provide a regulated DC voltage to the inverter. It is used maintain a constant DC link voltage. • Rotor Side Converter: It is a DC-AC inverter which is used to provide controlled AC voltage to the rotor.
  • 11. REASON FOR USE OF DFIG IN WIND GENERATION • Constant frequency output signal to the grid irrespective of the variable rotor speed. • Low power rating required for the power electronic devices and hence low cost of control system. • Power factor is controlled, i.e. maintained at unity. • Electric power generation at low wind speed. • Power electronic converter has to handle the fraction of the total load i.e.,20-30% and also cost of this converter is low than in case of the other types of generators.