Efficacy and safety: check...by using the
right sensor solution
Bram Stelt – Large Account Manager
Booth: 551
Cell: +31(0) 6 2117 7287
bram@exergenglobal.com
www.exergenglobal.com
Requests from the market:
- Increased speed
- Increased quality
- Guaranteed safety
Downside:
- Same or less budget
- More challenging conditions
TRENDS
SOME EXAMPLES
Welding Flash Cure
The right sensor - simply not enough
- Innovative sensor technology
- Smart mechanical engineering teams
and
- In depth know how of thermal processes
APPROACH
SENSORANICS METHODOLOGY
SENSOR BY DESIGN………………THE PROCESS
Velashape II
CASE STUDY – COSMETIC INDUSTRY
Potential Market for Fat Destruction Procedures
In a survey of 1,045 women in NA
56%
indicated interest in non-invasive fat destruction procedures
Total Addressable Market in the US: 19.5M Patients
World Market: $2 billion
by 2017 ($700 million in
the US - Globaldata)
MARKET SIZE
Survey Takeaway:
• “Pain-free with no downtime, it’s effective and totally
believable.”
• “Over 75% of patients come in to my office and immediately
ask “How much is it going to hurt?"
PAIN FREE TREATMENT - SAFETY
PRINCIPLE OF OPERATION
OBJECTIVE
Next generation, Velashape III:
- Pain free treatments
- More efficient treatment
- No downtime.
Request
- Non contact temperature sensor integrated in applicator for
skin temperature monitoring
- Closed loop RF mechanism to ensure reaching the set-point
skin temperature for optimal treatment efficacy, and NOT
exceed the set-point temperature for patient safety and
comfort.
OBJECTIVE SYNERON
Our challenges:
- Size – very limited space
available
- Direct IR lamp interference
- Field of view – lens
- Ambient temperature
fluctuations
- Gel applied on skin: thermal
gradient.
CHALLENGES
Solution: Sensor selection:
- Small size
- Thermocouple compatible
- Unpowered
- No drift
- High accuracy
- High repeatability
- High interchangeability.
OUR CHALLENGE: SIZE – VERY LIMITED
SPACE AVAILABLE
Direct influence from IR lamps:
immediate sensor response when IR
lamps were switched on –
measurement error of approx 3C.
OUR CHALLENGE: DIRECT IR LAMP
INTERFERENCE
Inner copper shroud blocking IR lamp radiation.
Inner surface of shroud must be very low emissivity,
otherwise the temperature of the shroud itself is
measured.
SOLUTION: DIRECT IR LAMP INTERFERENCE
OUR CHALLENGE: FIELD OF VIEW - LENS
SOLUTION: FIELD OF VIEW
SOLUTION: FIELD OF VIEW
No Power Required
T/C Compatible
Compensates for the Ambient Temperature
AMBIENT TEMPERATURE COMPENSATION
ZnSe lens and window are not 100% transparent for IR
radiation – some signal is absorbed:
Sensor spectral response: 5.5 – 20 µm
OUR CHALLENGE: BIG AMBIENT
TEMPERATURE FLUCTUATIONS
The thermopile detector is responsive to the net power that it absorbs:
P = σ * A * (Tt4 - Ta4)
The Stefan-Boltzmann equation where:
- P = net radiation power
- A = surface area
- Tt = target temperature
- Ta = detector temperature.
Since the detector absorbs power at σ * A * (Tt4) and re-radiates power
at its own temperature, the σ * A * (- Ta4) term is needed.
Tt is attenuated by the additional lens and window attenuate
Ta is unchanged: ambient compensation error
OUR CHALLENGE: BIG AMBIENT
TEMPERATURE FLUCTUATIONS
1) Sensor thermally isolated: slower heat up and more
uniform heating
2) Additional thermocouple to measure sensor housing
temperature to allow accurate ambient temperature
compensation1.
1: solution that is provided to Syneron is under NDA and can not be
disclosed here. The example given here is more general in nature but covers
the concept
SOLUTION: BIG AMBIENT TEMPERATURE
FLUCTUATIONS
mVo
mVTC
SOLUTION: BIG AMBIENT TEMPERATURE
FLUCTUATIONS
OUR CHALLENGE: GEL ON SKIN – THERMAL
GRADIENT. SOLUTION: HEAT BALANCE
The results for Tt=24C and Tt=59C.
- IRt/c = Initial temp. in degC,
- t/c = additonal t/c temp in degC,
- Corrected: with ambient temperature compensation
- Scaled: with heat balance.
RESULTS
VelaShape III Advantages
Increased RF Power:
- End point temperature is achieved much faster
- Reduction in treatment time
- Consistent, reproducible resultst
Sophisticated Feedback Mechanisms:
- New closed loop RF mechanism and built in
temperature sensor
- Better monitoring for elevated temperature in
the tissue
- Increased patient comfort and safety
Movie
Two important items I would like you to
walk away with:
1. Market is very demanding and keeps on
challenging the industry
2. There is always a solution if the thermal
process is thoroughly understood –
sensor by design.
TO TAKE HOME
THANK YOU – TIME FOR ?
Bram Stelt – Large accountmanager
Booth: 551
Cell: +31(0) 6 2117 7287
bram@exergenglobal.com
www.exergenglobal.com
www.sensoranics.com

More Related Content

PPTX
Viscosity Measurement
PDF
Light Meter (LM-120)
PDF
Special Report-aromatics final
PDF
PISIDIA S--S 2015 Lookbook
PPTX
Final Presentation (REVISION 2)
PPTX
Final Control Element
PDF
Force, Pressure and Torque measurements
PDF
IJSRED-V1I2P7
Viscosity Measurement
Light Meter (LM-120)
Special Report-aromatics final
PISIDIA S--S 2015 Lookbook
Final Presentation (REVISION 2)
Final Control Element
Force, Pressure and Torque measurements
IJSRED-V1I2P7

Similar to finalSensors2015_SpeakerPresentationPPT_Exergen Global Bram Stelt_DEFINITIEF (20)

PPTX
Ground Reaction Force Sensor unit 1 .pptx
PPTX
weld metal temperature measurement device ppt
PPT
Energy sensors2 second review
PDF
Ayaz_portfolio
PDF
What is physical sensors in smart home systems? -- C&T RF Antennas Inc
PPTX
ECE480 Tech Presentation1.1.pptx
PDF
Iaetsd fiber optics in sensing and measurement
PDF
temp mesurement eng a_w
DOCX
Sensors
PPT
080 intravascular micro bolometer catheter
PDF
B42050408
PDF
Temperature Sensors used in Pharmaceutical Industry and its application
PPTX
13. Temperature measurements.pptx
PPTX
PPT
Intravascular micro bolometer catheter thi
PDF
Inductive Non-Contact Position/Displacement Sensing: Technology-Application-O...
PPT
080 intravascular micro bolometer catheter
PPT
SILICON-CARBIDE BASED TEMPERATURE SENSOR USING OPTICAL PYROMETRY AND LASER I...
PPTX
measurement :Temperature
PPT
Gorgeous
Ground Reaction Force Sensor unit 1 .pptx
weld metal temperature measurement device ppt
Energy sensors2 second review
Ayaz_portfolio
What is physical sensors in smart home systems? -- C&T RF Antennas Inc
ECE480 Tech Presentation1.1.pptx
Iaetsd fiber optics in sensing and measurement
temp mesurement eng a_w
Sensors
080 intravascular micro bolometer catheter
B42050408
Temperature Sensors used in Pharmaceutical Industry and its application
13. Temperature measurements.pptx
Intravascular micro bolometer catheter thi
Inductive Non-Contact Position/Displacement Sensing: Technology-Application-O...
080 intravascular micro bolometer catheter
SILICON-CARBIDE BASED TEMPERATURE SENSOR USING OPTICAL PYROMETRY AND LASER I...
measurement :Temperature
Gorgeous
Ad

finalSensors2015_SpeakerPresentationPPT_Exergen Global Bram Stelt_DEFINITIEF

  • 1. Efficacy and safety: check...by using the right sensor solution Bram Stelt – Large Account Manager Booth: 551 Cell: +31(0) 6 2117 7287 [email protected] www.exergenglobal.com
  • 2. Requests from the market: - Increased speed - Increased quality - Guaranteed safety Downside: - Same or less budget - More challenging conditions TRENDS
  • 4. The right sensor - simply not enough - Innovative sensor technology - Smart mechanical engineering teams and - In depth know how of thermal processes APPROACH
  • 7. Velashape II CASE STUDY – COSMETIC INDUSTRY
  • 8. Potential Market for Fat Destruction Procedures In a survey of 1,045 women in NA 56% indicated interest in non-invasive fat destruction procedures Total Addressable Market in the US: 19.5M Patients World Market: $2 billion by 2017 ($700 million in the US - Globaldata) MARKET SIZE
  • 9. Survey Takeaway: • “Pain-free with no downtime, it’s effective and totally believable.” • “Over 75% of patients come in to my office and immediately ask “How much is it going to hurt?" PAIN FREE TREATMENT - SAFETY
  • 12. Next generation, Velashape III: - Pain free treatments - More efficient treatment - No downtime. Request - Non contact temperature sensor integrated in applicator for skin temperature monitoring - Closed loop RF mechanism to ensure reaching the set-point skin temperature for optimal treatment efficacy, and NOT exceed the set-point temperature for patient safety and comfort. OBJECTIVE SYNERON
  • 13. Our challenges: - Size – very limited space available - Direct IR lamp interference - Field of view – lens - Ambient temperature fluctuations - Gel applied on skin: thermal gradient. CHALLENGES
  • 14. Solution: Sensor selection: - Small size - Thermocouple compatible - Unpowered - No drift - High accuracy - High repeatability - High interchangeability. OUR CHALLENGE: SIZE – VERY LIMITED SPACE AVAILABLE
  • 15. Direct influence from IR lamps: immediate sensor response when IR lamps were switched on – measurement error of approx 3C. OUR CHALLENGE: DIRECT IR LAMP INTERFERENCE
  • 16. Inner copper shroud blocking IR lamp radiation. Inner surface of shroud must be very low emissivity, otherwise the temperature of the shroud itself is measured. SOLUTION: DIRECT IR LAMP INTERFERENCE
  • 17. OUR CHALLENGE: FIELD OF VIEW - LENS
  • 20. No Power Required T/C Compatible Compensates for the Ambient Temperature AMBIENT TEMPERATURE COMPENSATION
  • 21. ZnSe lens and window are not 100% transparent for IR radiation – some signal is absorbed: Sensor spectral response: 5.5 – 20 µm OUR CHALLENGE: BIG AMBIENT TEMPERATURE FLUCTUATIONS
  • 22. The thermopile detector is responsive to the net power that it absorbs: P = σ * A * (Tt4 - Ta4) The Stefan-Boltzmann equation where: - P = net radiation power - A = surface area - Tt = target temperature - Ta = detector temperature. Since the detector absorbs power at σ * A * (Tt4) and re-radiates power at its own temperature, the σ * A * (- Ta4) term is needed. Tt is attenuated by the additional lens and window attenuate Ta is unchanged: ambient compensation error OUR CHALLENGE: BIG AMBIENT TEMPERATURE FLUCTUATIONS
  • 23. 1) Sensor thermally isolated: slower heat up and more uniform heating 2) Additional thermocouple to measure sensor housing temperature to allow accurate ambient temperature compensation1. 1: solution that is provided to Syneron is under NDA and can not be disclosed here. The example given here is more general in nature but covers the concept SOLUTION: BIG AMBIENT TEMPERATURE FLUCTUATIONS
  • 24. mVo mVTC SOLUTION: BIG AMBIENT TEMPERATURE FLUCTUATIONS
  • 25. OUR CHALLENGE: GEL ON SKIN – THERMAL GRADIENT. SOLUTION: HEAT BALANCE
  • 26. The results for Tt=24C and Tt=59C. - IRt/c = Initial temp. in degC, - t/c = additonal t/c temp in degC, - Corrected: with ambient temperature compensation - Scaled: with heat balance. RESULTS
  • 27. VelaShape III Advantages Increased RF Power: - End point temperature is achieved much faster - Reduction in treatment time - Consistent, reproducible resultst Sophisticated Feedback Mechanisms: - New closed loop RF mechanism and built in temperature sensor - Better monitoring for elevated temperature in the tissue - Increased patient comfort and safety Movie
  • 28. Two important items I would like you to walk away with: 1. Market is very demanding and keeps on challenging the industry 2. There is always a solution if the thermal process is thoroughly understood – sensor by design. TO TAKE HOME
  • 29. THANK YOU – TIME FOR ? Bram Stelt – Large accountmanager Booth: 551 Cell: +31(0) 6 2117 7287 [email protected] www.exergenglobal.com www.sensoranics.com

Editor's Notes

  • #2: Sensor = non contact infrared temperature sensors
  • #3: - peil audience: wie in print, wie in medisch etc?
  • #4: Wat willen jullie zien/horen
  • #5: Uitdagingen worden te groot – off the shelve niet meer genoeg: steeds complexere machines Voorbeeld: HP: dubbele druk – concurrentie en druk van binnenuit. Hogere snelheid en nauwkeurigheid steeds belangrijker, en liefst zo klein mogelijk. Dit heeft grote gevolgen voor thermische processen. Getallen van de markt – groeimarkt. Non contact IR heel belangrijk voor snelheid en safety
  • #8: Goed voorbeeld: cosmetisch industry is growing – vrouwen blijven vrouwen en het wordt bijna zomer
  • #10: Syneron was marktleiden, maar dreigde die positie kwijt te raken. Moest een nieuwe flagship komen om weer nr1 in de markt te worden. Luisteren naar de klant.
  • #11: Apoptosis of fat tissue: heating up fat tissue to set point temperature for certain time: fat tissue destroyed
  • #12: Apoptosis of fat tissue: heating up fat tissue to set point temperature for certain time: fat tissue destroyed
  • #13: Patients: pain free No lawsuits!!!! . Specialists: faster and no downtime – dus meer treatments in een dag – bigger revenue. Bredere doelgroep: van artsen naar beauty clinics – easy to use and safety guaranteed.
  • #14: ONZE challenges
  • #15: Praat over ‘we found a sensor’ niet Exergen specifiek benoemen
  • #24: Unique solution for Syneron is under NDA: the solutions given here are more general in nature but grasp the concept
  • #26: Non-contact IR sensing: only surface temperature is measured, which in this case is the gel and not the skin.
  • #28: Flagship product met enorme voordelen – USP met als belangrijkste: safety.