SlideShare a Scribd company logo
Greystone product
Our Vision
Greystone’s vision is to design and manufacture a wide range of high
quality products for sensing, measuring and transmitting of data
related to temperature, humidity, pressure, current, air quality and
hazardous gases.
This vision is realized through dedication and rigid adherence to our
quality standards, exemplary service provided to our customers, the
genuine pride we take in our work and Greystone’s continued quest to
advance the state
of the industry through research and development.
•Our production procedures allow us to maintain the depth and
flexibility to commit to Just-In-Time deliveries
•Follow strict adherence to our ISO 9001-2008 quality program
and adhere to many environmental requirements
•NIST traceable calibration chambers
•5-year limited warranty on all manufactured products
Who We Are
• Established in 1983
• Based in Moncton, New Brunswick, Canada
• 2600m² manufacturing facility
• Employing over 100 full time administration,
sales, production, engineering and support
staff in 8 strategic locations
Where We Are
Moncton New Brunswick Canada
Vancouver
Toronto
Moncton
Montreal
Head Office & Factory
Moncton, N.B.
Where We Are
Canada/USA & International Offices
Pittsburgh, PA
Grand Rapids, MI
Indianapolis, IN
Dubai, UAE
Bangalore, India
Kuala Lumpur, Malaysia
Singapore
Product Offerings
BACnet®
Interface
Hardware . . . . . . . . . . . . . . . . 2-wire RS-485
Software . . . . . . . . . . . . . . . . . Native BACnet®
MS/TP protocol
Baud Rate . . . . . . . . . . . . . . . . 9600 to 115200
MAC Address Range . . . . . . . 0-127
BACnet® / Modbus
Modbus
Interface
Hardware . . . . . . . . . . . . . . . . 2-wire RS-485
Software . . . . . . . . . . . . . . . . . Native ModBus MS/TP protocol
(RTU or ASCII)
Baud Rate . . . . . . . . . . . . . . . . 300 to 115200
Slave Address Range . . . . . . . 1-255
TS/TE200 Series
Sensor Only
TX/TE500/511
Series
Sensor with Transmitter
Optional LCD Display C°
Temperature
• Thermistors & RTD’s
• Styles Include: Room, Duct, Duct
Average, Immersion, Strap-on, &
OSA
• Various Probe Lengths
• Multiple Enclosure Choices
• Available Room Options: Setpoint
Adj., Override, Internal/External
Comm. Jacks, Local Display
Temperature –
TS/TE200 Series
•Platinum RTD Sensor –
100 or 1000 ohm
•Transmitters With Several
Temperature Ranges To Select
From
•24 Vac/dc
•4-20 mA, 0-5 Vdc or 0-10 Vdc
Temperature –
TX/TE500 Series
• BACnet® or Modbus
Communications
• Temperature Monitoring
• Optional Humidity
• Setpoint Adjustment
• Manual Override with LCD
Status
• LCD °C and %RH
• 5 Position Fan Speed Switch
NTRC - Temperature
and RH
• Space, Duct & OSA
• Accuracy: 2,%, 3%, & 5%
• Fast Response
• Temperature Compensated
• VOC Resistant
• Optional Temperature Sensor
or Transmitter
• LCD Display Available, %RH
• Optional Setpoint Control
and Manual Override
Humidity – HRC, RH
& SPC Series
• Temperature & Humidity
• High Accuracy Thermistors & RTD’s
• Styles Include: Room, Duct, Duct
Average, Immersion, Strap-on, &
OSA
• Various Probe Lengths
• Multiple Enclosure Choices
• LCD Display
• Available Room Options: Setpoint
Adj., Override, Internal/External
Comm. Jacks
High Accuracy
• Models For Monitoring Duct, Room
or Building Pressure
• Ranges Available From 30 thru 2000 Pa
(0.125” thru 20” wc)
• Offset Zero Models -125 to 125 Pa
(i.e.: -0.5” to +0.5” wc)
• Field Selectable Ranges
• Field Selectable Outputs
• Optional LCD, Pa or ”wc
• Optional Adjustable Relay Models
• Optional BACnet® Communications
(RPC & ULP only)
Low Pressure
Transmitters
• Analog or BACnet® Output
• Ranges Available From +/-30 Pa thru
+/- 250 Pa (+/-0.125” thru +/-1”) 3 Field
Selectable Analog Outputs
• Accuracy 1% FSO
• LCD Display
• Relay Output for Remote Alarm
with LED Indication
• Silence Switch
• Optional Pick-Up Port and
Remote Audible Alarm
RPC - Room
Pressure Monitor
• Analog or BACnet® Output
• Ranges Available from +/- 30 Pa
thru +/- 250 Pa (+/-0.125” thru +/-1”
wc)
• 8 Selectable Unit or Bi-directional
Ranges (Analog)
• 3 Field Selectable Analog Outputs
(Analog Model)
• Accuracy 1% FSO
• LCD Display
• Relay Output for Remote Alarm
ULP - Ultra Low
Pressure Transmitter
• Gauge or Differential Models
• 4 Field Selectable Ranges
per Model
• Pressure Ranges up to 3000
kPa, 30 Bar, 500 psig/D
• Corrosion Resistant 17-4PH
S/S Sensor Construction
• Latched/Hinged Cover
for Easy Access
• Optional LCD
• Pressure ranges available
up
to 68,947 kPa (10,000 psig)
• 24 Vdc, 4-20 mA, 2 Wire
• Accurate to ±0.25% FSO
• Corrosion Resistant
17-4PH S/S Construction
Liquid Pressure
Transmitters
• Optional pressure ranges available
• Range adjustment knob with increments
• IP54 Enclosure
• Includes 2 pick up tubes and 2 m of PVC tubing
• 2 Selectable Ranges – 16 m/sec & 8 m/sec
• Linear 4-20 mA or 0-10 Vdc Output
• AC/DC Voltage Supply
• Telescopic Sensing Probe 50-185 mm
• Temperature Output: 0-10 Vdc
Airflow Switches
and Transmitter
• Switch or Sensor Models
• Mini solid, Solid or Split-core Models
• Up to 100 or 200 Amp Models
• Switches - Go/No Go or Adjustable
Setpoint Models
• Switches – AC/DC Switching and High
amp Switching Models
• Sensors – 4-20 mA, 0-5 or 0-10 Vdc
Models
• Sensors – Fixed or Selectable Range
Models
• Optional Snap-On Command Relay
Current Sensors
& Switches
• Analog, BACnet® or Modbus
• 8 Parameters to Select From for Analog
Version
• 53 Parameters to Select From on
BACnet®/Modbus Versions
• Supports 0.333V Safe CT’s or 5 AMP
CT’s
• Measures up to 600 VAC Directly
• Optional Onboard Data Logging
• IP65 (NEMA 4) Enclosure
Power Monitor
• Various Analog Inputs to
Pneumatic 3-15 psig Output
• Snap-Track or Enclosed Models
• Optional Pressure Gauge
Pneumatic
Transducers
• Various Input/Output Signals
• Relay Sequencers
• Analog Isolation Modules
• Analog Rescaling
• Signal Conversion
• Analog to Resistance
Signal Interfaces
• Models with Analog, BACnet® or
Modbus Outputs
• CO , with Optional Temperature &₂
Humidity Outputs
• Wall, Duct or OSA Mount Models
• Optional Setpoint and/or Override
• Optional On-Board Relay
• Optional LCD Display
• Decorative, Compact Enclosure
• 5 Year Calibration Interval for CO₂
Carbon Dioxide Transmitters
• BACnet®® or Modbus
Communication
• Menu Driven Set-up
• 0-2000 PPM CO Range₂
• Optional Temperature & RH Output
• Patented Self-Calibration Algorithm
• Guaranteed 5 Year Calibration Interval
• Easily Field Calibrated
CDD3 - CO₂, Temp & RH
with BACnet® or Modbus
• Optional BACnet® or Modbus
Communications
• Surface or Duct Mount
• 5 Field Selectable Ranges
• Replaceable Electrochemical Sensor Module
• 3 Field Selectable Analog Outputs
• Easy to Calibrate in the Field
• LCD, Audible Alarm & Test Switch
• Optional Field Adjustable Alarm Relays
CMD – Carbon
Monoxide Monitor
• Optional Modbus
Communications
• Range: 0-300 PPM @ 5%
(0-500 PPM for Modbus)
• Electrochemical Sensor
• Compact, IP65 Enclosure
• Loop-powered 4-20 mA Signal
• Easy to Calibrate in the Field
• Optional Field Adjustable Alarm
Relays
CMD Carbon
Monoxide Monitor
Nitrogen Dioxide
Monitor
• Superior Electrochemical Sensor
• 0-10 PPM Range
• 4-20 mA Output
• Alarm Relay with Selectable Trip
Level
• Easy to Field Calibrate
• Compact, IP65 (NEMA 4X)
Enclosure
NDD Nitrogen
Dioxide Monitor
• Room or Outside Mount
• True Air Quality Monitor
• Measures Total VOC’s
• Direct Correlation to CO₂ levels
• High Sensitivity and Fast Response
• Linear and Stepped Analog Output
• LCD to Display Air Quality Information
• Optional Relay Output
• Optional Temperature Sensor
AIR4 - Air Quality
Monitor
• Photoelectric
Detector Heads
• Optional Sampling
Tubes Up To 3m Metric
• UL, MEA, CSFM Listed
SL-2000 Duct
Smoke Detector
Water
Detectors
Water Detection
Damper
End Switch
(DES-100)
General
Purpose
Relays
Power
Supplies (PS-
100)
Miscellaneous
Products
Implemented in 1994
Implemented in 2006
Greystone
Quality & Standards
Greystone Standards
1. Greystone’s Market Focus
• Over 30 years designing, manufacturing and supplying HVAC sensors and transmitters
• 100% of Greystone’s sales volume is HVAC sensors and transmitters
• Greystone HVAC sensors and transmitters are listed by some of the foremost engineering companies worldwide
as their specification standard
2. Greystone’s Quality
• Greystone has over 20 years manufacturing with an ISO 9001 Certified Quality Assurance program
• 100% product testing done by Greystone prior to shipping to the customer
• Greystone strives for a zero percent failure rate on manufactured products
• Due to Greystone’s confidence in our design, manufacturing and testing procedures, Greystone
provides a limited warranty of 60 months (5 years)
• Greystone meets or exceeds industry standards for HVAC sensors and transmitters
3. Greystone’s Research & Development
1. All Greystone products are designed & tested in-house
2. The latest design tools are used for both hardware and software development
3. All product designs utilize the highest quality sensors and components
Why Greystone?
4.Greystone’s Manufacturing
•All Greystone products are manufactured in North America
•All Greystone products are manufactured in our own facility which allows for 100% control over the
manufacturing process, quality control and product delivery
•Greystone produces all of our circuit boards in-house with the latest technology in surface mount and thru-hole
equipment
•Every circuit board Greystone manufactures goes through electronic QA inspection stations which
inspect every component, alignment and solder joints, assuring zero defects due to human or machine error
•All Greystone’s calibration and testing standards are NIST traceable
5.Greystone’s Customer Focus
•All Greystone’s sales people have technical backgrounds and have over 300 combined years of industry experience
•Greystone has in-house product technical support and installation assistance to our customers worldwide
•Greystone offers a state of the art online buying site
•Greystone’s website has complete information on our company, our facilities, our people, our standards,
complete product information specification and installation notes
•Greystone offers custom design services to our customers to meet custom applications
Why Greystone?
Greystone product

More Related Content

PDF
Ecotech serinus-44-ammonia-analyser
European Tech Serv
 
PDF
Nitrogen serinus-40-n ox-gas-analyser
European Tech Serv
 
PDF
No2 analyser-ecotech
European Tech Serv
 
PDF
Rotronic Data Sheet CRP5 Clean Room Panel
PT. Siwali Swantika
 
PDF
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
ENVIMART
 
PDF
pH.ORP Transmitter-Analog and digital glass
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
PDF
Serinus 50-so2-gas-analyser
European Tech Serv
 
PDF
Monicon 4 channel datasheet
a1-cbiss
 
Ecotech serinus-44-ammonia-analyser
European Tech Serv
 
Nitrogen serinus-40-n ox-gas-analyser
European Tech Serv
 
No2 analyser-ecotech
European Tech Serv
 
Rotronic Data Sheet CRP5 Clean Room Panel
PT. Siwali Swantika
 
Liquisys m clm223 253 endress+hauser datasheet-conductivity-resistivity measu...
ENVIMART
 
pH.ORP Transmitter-Analog and digital glass
Edress Hauser: Flow Meter, Level, Pressure, Temperature
 
Serinus 50-so2-gas-analyser
European Tech Serv
 
Monicon 4 channel datasheet
a1-cbiss
 

What's hot (19)

PDF
Thermal Mass Flowmeter and Temperature Transmitter
Classic Controls, Inc.
 
PDF
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
ENVIMART
 
PDF
Wavetronics, Ahmedabad, AVF Meter
IndiaMART InterMESH Limited
 
PDF
IoT Connected Steam Flow Meter - Compact Orifice
Daviteq Company Ltd.
 
PDF
Thermal Mass Flow Meter for Oil & Gas Applications
Classic Controls, Inc.
 
PDF
The CAL range of temperature controllers
West Control Solutions
 
PDF
Sierra Flowmeters
Litre Meter
 
PPTX
Precise Presentation
Prashant Bhujbal
 
PDF
Đồng Hồ Đo Lưu Lượng nước, khí, Gas
Đồng Hồ Đo Lưu Lượng
 
PPTX
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
Transcat
 
PDF
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
ENVIMART
 
PDF
Datasheet Fluke Explosive Area. Hubungi PT. Siwali Swantika 021-45850618
PT. Siwali Swantika
 
PDF
GCEM4000 insitu gas analyser codel datasheet
ENVIMART
 
PDF
Microtrans differential pressure and airflow signal processor
xanderGal123
 
PDF
Non-Invasive Gas Flow Measurement
M.S. Jacobs & Associates
 
PDF
Spec sheet Cemtek Model 1000 Oxygen Monitor
Brian Gilmore
 
PDF
Katalog agilent-digital-multimeter-3458 a-digital-multimeter-tridinamika
PT. Tridinamika Jaya Instrument
 
PDF
Katalog agilent-3458 a-digital-multimeter- 8½-digit-tridinamika
PT. Tridinamika Jaya Instrument
 
Thermal Mass Flowmeter and Temperature Transmitter
Classic Controls, Inc.
 
Easy line EL3000 series ABB CEMS Datasheet-continuous gas analyzers
ENVIMART
 
Wavetronics, Ahmedabad, AVF Meter
IndiaMART InterMESH Limited
 
IoT Connected Steam Flow Meter - Compact Orifice
Daviteq Company Ltd.
 
Thermal Mass Flow Meter for Oil & Gas Applications
Classic Controls, Inc.
 
The CAL range of temperature controllers
West Control Solutions
 
Sierra Flowmeters
Litre Meter
 
Precise Presentation
Prashant Bhujbal
 
Đồng Hồ Đo Lưu Lượng nước, khí, Gas
Đồng Hồ Đo Lưu Lượng
 
Testing and Troubleshooting 4-20 mA Control Loops Presented by Fluke and Tra...
Transcat
 
DCEM1000 1001 d-codel datasheet-cem1000_1001 opacity monitor
ENVIMART
 
Datasheet Fluke Explosive Area. Hubungi PT. Siwali Swantika 021-45850618
PT. Siwali Swantika
 
GCEM4000 insitu gas analyser codel datasheet
ENVIMART
 
Microtrans differential pressure and airflow signal processor
xanderGal123
 
Non-Invasive Gas Flow Measurement
M.S. Jacobs & Associates
 
Spec sheet Cemtek Model 1000 Oxygen Monitor
Brian Gilmore
 
Katalog agilent-digital-multimeter-3458 a-digital-multimeter-tridinamika
PT. Tridinamika Jaya Instrument
 
Katalog agilent-3458 a-digital-multimeter- 8½-digit-tridinamika
PT. Tridinamika Jaya Instrument
 
Ad

Similar to Greystone product (20)

PDF
United Electric 2018 Short Form Product Catalog
Ives Equipment
 
PDF
Bacnet brochure
RJM123
 
PDF
Pyrosales Catalogue - Total Sensor Solution Providers
PYROSALES
 
PDF
Mini rae 3000
a1-cbiss
 
PDF
TCS Basys Controls Overview 2017
James Huffstutler
 
PDF
Environmental sensors
Hangkheang Khy
 
PDF
Rotronic Data Sheet HygroFlex8 Industrial Transmitter
PT. Siwali Swantika
 
PPTX
Data Center Monitoring
Powercast Sensors
 
PPT
Net Safety Monitoring Flame & Gas Detection
Rosemount Analytical - Emerson Process Management
 
PDF
Coriolis rct1000 datasheet badger meter rct1000 with rcs018...300 sensors
ENVIMART
 
PDF
ATIs-D12-Digital-Gas-Transmitter.pdf
ENVIMART
 
PDF
Ds bac 1xxxxx-91403501_e
alfmich
 
PDF
Catalouge
mayur_32
 
PPTX
Gas Transmitters
Dwyer Instruments
 
PPTX
MadgeTech Wireless Data Loggers
MadgeTech Inc
 
PDF
Controls And Engrs, Chennai, Globe Flow Switches
IndiaMART InterMESH Limited
 
PDF
Producto 0164-84713
Raul Mista
 
PDF
Samson Automation, Bengaluru, Pocket Oxygen Meter
IndiaMART InterMESH Limited
 
PDF
Mx43 Gas Detector
a1-cbiss
 
PDF
IW2S1-150FE-L
Eong Huat Corporation
 
United Electric 2018 Short Form Product Catalog
Ives Equipment
 
Bacnet brochure
RJM123
 
Pyrosales Catalogue - Total Sensor Solution Providers
PYROSALES
 
Mini rae 3000
a1-cbiss
 
TCS Basys Controls Overview 2017
James Huffstutler
 
Environmental sensors
Hangkheang Khy
 
Rotronic Data Sheet HygroFlex8 Industrial Transmitter
PT. Siwali Swantika
 
Data Center Monitoring
Powercast Sensors
 
Net Safety Monitoring Flame & Gas Detection
Rosemount Analytical - Emerson Process Management
 
Coriolis rct1000 datasheet badger meter rct1000 with rcs018...300 sensors
ENVIMART
 
ATIs-D12-Digital-Gas-Transmitter.pdf
ENVIMART
 
Ds bac 1xxxxx-91403501_e
alfmich
 
Catalouge
mayur_32
 
Gas Transmitters
Dwyer Instruments
 
MadgeTech Wireless Data Loggers
MadgeTech Inc
 
Controls And Engrs, Chennai, Globe Flow Switches
IndiaMART InterMESH Limited
 
Producto 0164-84713
Raul Mista
 
Samson Automation, Bengaluru, Pocket Oxygen Meter
IndiaMART InterMESH Limited
 
Mx43 Gas Detector
a1-cbiss
 
IW2S1-150FE-L
Eong Huat Corporation
 
Ad

Recently uploaded (14)

PDF
Brand Projection 191 Nutrition-The Sales Knob
The Sales Knob
 
PDF
Balwaan High Pressure Washer Machine PW-400
Balwaan Krishi
 
PDF
Enhance Your Lighting Solutions with Vapor Tight LED Lights
Lightide Manufactory Co., Ltd
 
PPTX
Basics of professional selling (Sell as a professor).pptx
Mohamed Abu Rahal
 
PDF
Unlock Global Opportunities with Real-Time Tender Data
infosaddamkhan868
 
PDF
Building Your Personal Brand Ebook Workbook.pdf
Rich Vibes Publication
 
PDF
Shae McCutchen - Specializing In Salesforce Platform
Shae McCutchen
 
PDF
🔴BUKTI KEMENANGAN HARI INI SELASA 29 JULI 2025 !!!🔴 #kiper4d
GRAB
 
PPTX
Actionable plan to boost sales(north region).pptx
kriti904817
 
PPTX
THIS IS A C LANGUAGE BASIC CONCEPT LIKE LOOP
prajapatiparth131220
 
PPTX
pitch 3 for sales deck template company presentataion.pptx
DhruvPacheriwala1
 
PDF
KIPER4D EXCLUSIVE SERVER STAR GAMING ASIA NO.1 TERPOPULER DI INDONESIA !!! Ra...
GRAB
 
PPTX
Tissue.pptxlvgjilptugil;tuilotuiltultuiiutlo
tejaspagar394
 
PPTX
A Complete Guide through PCB Assembly Process Services.pptx
GREATPCB SMT LIMITED
 
Brand Projection 191 Nutrition-The Sales Knob
The Sales Knob
 
Balwaan High Pressure Washer Machine PW-400
Balwaan Krishi
 
Enhance Your Lighting Solutions with Vapor Tight LED Lights
Lightide Manufactory Co., Ltd
 
Basics of professional selling (Sell as a professor).pptx
Mohamed Abu Rahal
 
Unlock Global Opportunities with Real-Time Tender Data
infosaddamkhan868
 
Building Your Personal Brand Ebook Workbook.pdf
Rich Vibes Publication
 
Shae McCutchen - Specializing In Salesforce Platform
Shae McCutchen
 
🔴BUKTI KEMENANGAN HARI INI SELASA 29 JULI 2025 !!!🔴 #kiper4d
GRAB
 
Actionable plan to boost sales(north region).pptx
kriti904817
 
THIS IS A C LANGUAGE BASIC CONCEPT LIKE LOOP
prajapatiparth131220
 
pitch 3 for sales deck template company presentataion.pptx
DhruvPacheriwala1
 
KIPER4D EXCLUSIVE SERVER STAR GAMING ASIA NO.1 TERPOPULER DI INDONESIA !!! Ra...
GRAB
 
Tissue.pptxlvgjilptugil;tuilotuiltultuiiutlo
tejaspagar394
 
A Complete Guide through PCB Assembly Process Services.pptx
GREATPCB SMT LIMITED
 

Greystone product

  • 2. Our Vision Greystone’s vision is to design and manufacture a wide range of high quality products for sensing, measuring and transmitting of data related to temperature, humidity, pressure, current, air quality and hazardous gases. This vision is realized through dedication and rigid adherence to our quality standards, exemplary service provided to our customers, the genuine pride we take in our work and Greystone’s continued quest to advance the state of the industry through research and development.
  • 3. •Our production procedures allow us to maintain the depth and flexibility to commit to Just-In-Time deliveries •Follow strict adherence to our ISO 9001-2008 quality program and adhere to many environmental requirements •NIST traceable calibration chambers •5-year limited warranty on all manufactured products Who We Are • Established in 1983 • Based in Moncton, New Brunswick, Canada • 2600m² manufacturing facility • Employing over 100 full time administration, sales, production, engineering and support staff in 8 strategic locations
  • 4. Where We Are Moncton New Brunswick Canada Vancouver Toronto Moncton Montreal
  • 5. Head Office & Factory Moncton, N.B. Where We Are Canada/USA & International Offices Pittsburgh, PA Grand Rapids, MI Indianapolis, IN Dubai, UAE Bangalore, India Kuala Lumpur, Malaysia Singapore
  • 7. BACnet® Interface Hardware . . . . . . . . . . . . . . . . 2-wire RS-485 Software . . . . . . . . . . . . . . . . . Native BACnet® MS/TP protocol Baud Rate . . . . . . . . . . . . . . . . 9600 to 115200 MAC Address Range . . . . . . . 0-127 BACnet® / Modbus Modbus Interface Hardware . . . . . . . . . . . . . . . . 2-wire RS-485 Software . . . . . . . . . . . . . . . . . Native ModBus MS/TP protocol (RTU or ASCII) Baud Rate . . . . . . . . . . . . . . . . 300 to 115200 Slave Address Range . . . . . . . 1-255
  • 8. TS/TE200 Series Sensor Only TX/TE500/511 Series Sensor with Transmitter Optional LCD Display C° Temperature
  • 9. • Thermistors & RTD’s • Styles Include: Room, Duct, Duct Average, Immersion, Strap-on, & OSA • Various Probe Lengths • Multiple Enclosure Choices • Available Room Options: Setpoint Adj., Override, Internal/External Comm. Jacks, Local Display Temperature – TS/TE200 Series
  • 10. •Platinum RTD Sensor – 100 or 1000 ohm •Transmitters With Several Temperature Ranges To Select From •24 Vac/dc •4-20 mA, 0-5 Vdc or 0-10 Vdc Temperature – TX/TE500 Series
  • 11. • BACnet® or Modbus Communications • Temperature Monitoring • Optional Humidity • Setpoint Adjustment • Manual Override with LCD Status • LCD °C and %RH • 5 Position Fan Speed Switch NTRC - Temperature and RH
  • 12. • Space, Duct & OSA • Accuracy: 2,%, 3%, & 5% • Fast Response • Temperature Compensated • VOC Resistant • Optional Temperature Sensor or Transmitter • LCD Display Available, %RH • Optional Setpoint Control and Manual Override Humidity – HRC, RH & SPC Series
  • 13. • Temperature & Humidity • High Accuracy Thermistors & RTD’s • Styles Include: Room, Duct, Duct Average, Immersion, Strap-on, & OSA • Various Probe Lengths • Multiple Enclosure Choices • LCD Display • Available Room Options: Setpoint Adj., Override, Internal/External Comm. Jacks High Accuracy
  • 14. • Models For Monitoring Duct, Room or Building Pressure • Ranges Available From 30 thru 2000 Pa (0.125” thru 20” wc) • Offset Zero Models -125 to 125 Pa (i.e.: -0.5” to +0.5” wc) • Field Selectable Ranges • Field Selectable Outputs • Optional LCD, Pa or ”wc • Optional Adjustable Relay Models • Optional BACnet® Communications (RPC & ULP only) Low Pressure Transmitters
  • 15. • Analog or BACnet® Output • Ranges Available From +/-30 Pa thru +/- 250 Pa (+/-0.125” thru +/-1”) 3 Field Selectable Analog Outputs • Accuracy 1% FSO • LCD Display • Relay Output for Remote Alarm with LED Indication • Silence Switch • Optional Pick-Up Port and Remote Audible Alarm RPC - Room Pressure Monitor
  • 16. • Analog or BACnet® Output • Ranges Available from +/- 30 Pa thru +/- 250 Pa (+/-0.125” thru +/-1” wc) • 8 Selectable Unit or Bi-directional Ranges (Analog) • 3 Field Selectable Analog Outputs (Analog Model) • Accuracy 1% FSO • LCD Display • Relay Output for Remote Alarm ULP - Ultra Low Pressure Transmitter
  • 17. • Gauge or Differential Models • 4 Field Selectable Ranges per Model • Pressure Ranges up to 3000 kPa, 30 Bar, 500 psig/D • Corrosion Resistant 17-4PH S/S Sensor Construction • Latched/Hinged Cover for Easy Access • Optional LCD • Pressure ranges available up to 68,947 kPa (10,000 psig) • 24 Vdc, 4-20 mA, 2 Wire • Accurate to ±0.25% FSO • Corrosion Resistant 17-4PH S/S Construction Liquid Pressure Transmitters
  • 18. • Optional pressure ranges available • Range adjustment knob with increments • IP54 Enclosure • Includes 2 pick up tubes and 2 m of PVC tubing • 2 Selectable Ranges – 16 m/sec & 8 m/sec • Linear 4-20 mA or 0-10 Vdc Output • AC/DC Voltage Supply • Telescopic Sensing Probe 50-185 mm • Temperature Output: 0-10 Vdc Airflow Switches and Transmitter
  • 19. • Switch or Sensor Models • Mini solid, Solid or Split-core Models • Up to 100 or 200 Amp Models • Switches - Go/No Go or Adjustable Setpoint Models • Switches – AC/DC Switching and High amp Switching Models • Sensors – 4-20 mA, 0-5 or 0-10 Vdc Models • Sensors – Fixed or Selectable Range Models • Optional Snap-On Command Relay Current Sensors & Switches
  • 20. • Analog, BACnet® or Modbus • 8 Parameters to Select From for Analog Version • 53 Parameters to Select From on BACnet®/Modbus Versions • Supports 0.333V Safe CT’s or 5 AMP CT’s • Measures up to 600 VAC Directly • Optional Onboard Data Logging • IP65 (NEMA 4) Enclosure Power Monitor
  • 21. • Various Analog Inputs to Pneumatic 3-15 psig Output • Snap-Track or Enclosed Models • Optional Pressure Gauge Pneumatic Transducers
  • 22. • Various Input/Output Signals • Relay Sequencers • Analog Isolation Modules • Analog Rescaling • Signal Conversion • Analog to Resistance Signal Interfaces
  • 23. • Models with Analog, BACnet® or Modbus Outputs • CO , with Optional Temperature &₂ Humidity Outputs • Wall, Duct or OSA Mount Models • Optional Setpoint and/or Override • Optional On-Board Relay • Optional LCD Display • Decorative, Compact Enclosure • 5 Year Calibration Interval for CO₂ Carbon Dioxide Transmitters
  • 24. • BACnet®® or Modbus Communication • Menu Driven Set-up • 0-2000 PPM CO Range₂ • Optional Temperature & RH Output • Patented Self-Calibration Algorithm • Guaranteed 5 Year Calibration Interval • Easily Field Calibrated CDD3 - CO₂, Temp & RH with BACnet® or Modbus
  • 25. • Optional BACnet® or Modbus Communications • Surface or Duct Mount • 5 Field Selectable Ranges • Replaceable Electrochemical Sensor Module • 3 Field Selectable Analog Outputs • Easy to Calibrate in the Field • LCD, Audible Alarm & Test Switch • Optional Field Adjustable Alarm Relays CMD – Carbon Monoxide Monitor
  • 26. • Optional Modbus Communications • Range: 0-300 PPM @ 5% (0-500 PPM for Modbus) • Electrochemical Sensor • Compact, IP65 Enclosure • Loop-powered 4-20 mA Signal • Easy to Calibrate in the Field • Optional Field Adjustable Alarm Relays CMD Carbon Monoxide Monitor
  • 27. Nitrogen Dioxide Monitor • Superior Electrochemical Sensor • 0-10 PPM Range • 4-20 mA Output • Alarm Relay with Selectable Trip Level • Easy to Field Calibrate • Compact, IP65 (NEMA 4X) Enclosure NDD Nitrogen Dioxide Monitor
  • 28. • Room or Outside Mount • True Air Quality Monitor • Measures Total VOC’s • Direct Correlation to CO₂ levels • High Sensitivity and Fast Response • Linear and Stepped Analog Output • LCD to Display Air Quality Information • Optional Relay Output • Optional Temperature Sensor AIR4 - Air Quality Monitor
  • 29. • Photoelectric Detector Heads • Optional Sampling Tubes Up To 3m Metric • UL, MEA, CSFM Listed SL-2000 Duct Smoke Detector
  • 32. Implemented in 1994 Implemented in 2006 Greystone Quality & Standards
  • 34. 1. Greystone’s Market Focus • Over 30 years designing, manufacturing and supplying HVAC sensors and transmitters • 100% of Greystone’s sales volume is HVAC sensors and transmitters • Greystone HVAC sensors and transmitters are listed by some of the foremost engineering companies worldwide as their specification standard 2. Greystone’s Quality • Greystone has over 20 years manufacturing with an ISO 9001 Certified Quality Assurance program • 100% product testing done by Greystone prior to shipping to the customer • Greystone strives for a zero percent failure rate on manufactured products • Due to Greystone’s confidence in our design, manufacturing and testing procedures, Greystone provides a limited warranty of 60 months (5 years) • Greystone meets or exceeds industry standards for HVAC sensors and transmitters 3. Greystone’s Research & Development 1. All Greystone products are designed & tested in-house 2. The latest design tools are used for both hardware and software development 3. All product designs utilize the highest quality sensors and components Why Greystone?
  • 35. 4.Greystone’s Manufacturing •All Greystone products are manufactured in North America •All Greystone products are manufactured in our own facility which allows for 100% control over the manufacturing process, quality control and product delivery •Greystone produces all of our circuit boards in-house with the latest technology in surface mount and thru-hole equipment •Every circuit board Greystone manufactures goes through electronic QA inspection stations which inspect every component, alignment and solder joints, assuring zero defects due to human or machine error •All Greystone’s calibration and testing standards are NIST traceable 5.Greystone’s Customer Focus •All Greystone’s sales people have technical backgrounds and have over 300 combined years of industry experience •Greystone has in-house product technical support and installation assistance to our customers worldwide •Greystone offers a state of the art online buying site •Greystone’s website has complete information on our company, our facilities, our people, our standards, complete product information specification and installation notes •Greystone offers custom design services to our customers to meet custom applications Why Greystone?

Editor's Notes

  • #3: Our Vision Greystone’s vision is to design and manufacture a wide range of high quality sensing measurement and transmittal of data products related to temperature, humidity, pressure, current, air quality and hazardous gases. This vision is realized through our dedication to rigid adherence to quality standards, efficient service provided to our customers, the genuine pride we take in our work and our continued quest to advance the state of our industry through research and development.
  • #4: Greystone Energy Systems Inc. was established in 1983. Prior to this time our owner was employed as a regional manager of small building automation system company. It was during this time that he saw a market need for peripheral products to measure parameters such as temperature and humidity levels as the choices of product were very limited due the industry being in its infancy. Greystone was started and he hired his first employee to assist in the design and manufacture of a line of temperature sensors. During this time they worked from the basement of his home. Over the next few years sales grew and so did Greystone. Adding more employees and design engineers to develop more products. Today Greystone employs approximately 65 people in 4 locations.
  • #5: Our head office and factory is located in Moncton, NB Canada. Although Moncton is a small city (est Pop. 150,000) on the east coast of Canada we have many advantages from being located here. People in the area are very loyal and it shows in the fact that many of our employees have been with us for 10+ years. Moncton has 2 universities and 2 technical colleges which provide a vast pool of talented people as well as many more in the vicinty. Moncton is the Atlantic hub for many companies and therefore courier companies like UPS, Fed-X and Purolator use Moncton as their hub as well. Moncton is also a short distance away from major air and sea cargo ports which allows for decreased shipment times.
  • #6: To further assist our customers worldwide, Greystone has set up 3 satellite sales offices. At this time there are 2 in the United States and 1 in Singapore. In addition to these offices we many distributors worldwide.
  • #27: .
  • #33: Greystone’s quality department consists of 3 staff members that monitor all aspects of product development and manufacturing and has the authority to stop production if required. They are responsible for and perform quality inspections throughout the entire production process which includes incoming component testing, adherence to manufacturing and testing procedures and finished product testing. ISO 9001 - Greystone has established a reputation as a manufacturer dedicated maintaining an exemplary adherence to Quality Management Standards. Such that we have implemented a quality management system that is ISO9001 certified. Our quality system is audited annually by an outside agency in order to maintain our certification. Our quality management system provides tangible evidence of product reliability and conformity with our customer’s requirements due to our returned product rate is less then 0.2% of product shipped. This, itself provides a tremendous cost savings for both Greystone and our customers. RohS – The Directive on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002/95/EC commonly referred to as the Restriction of Hazardous Substances Directive or RoHS was adopted in February 2003 by the European Union and took effect on 1 July 2006, and is required to be enforced and become law in each member state. This directive restricts the use of six hazardous materials in the manufacture of various types of electronic and electrical equipment. RoHS is often referred to as the lead-free directive, but it restricts the use of seven substances: Lead (Pb) Mercury (Hg) Cadmiun (Cd) Hexavalent chromium (Cr6+) Polybrominated biphenyls (PBB) Polybrominated diphenyal (PBDE) Acrylamide
  • #34: CSA/UL – Although most of Greystone’s products are classed as low voltage devices and do not require any such approval, Greystone does manufacture a line of current sensors and switches that do require CSA/UL approval. During product development, our engineering team researches any approval requirements and designs to meet either CSA or UL standards. The product is then submitted to the appropriate agency for approval. CE - The European Union (EU) has implemented a system to protect the health and welfare of consumers and users of manufactured products and these products are identified by the use of "CE Marking"   These directives are voted into laws by the respective countries and compliance is required by all manufacturers and importers.Greystone Energy Systems, in conjunction with Intertek Testing Services (ITS), has successfully demonstrated compliance of many of our products to the appropriate EU directives. BTL - Greystone designed and manufactures a line of Carbon Dioxide/Temperature/Humidity transducers (CDD3 Series) that utilize the BACnet® communication protocol. This line has been tested and approved by BTL, listed on their approved product listing and have been approved to carry the BTL logo. It is our goal to offer more BACnet® compatible products in the future