International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1772
EFFECT OF DIFFERENT COLUMN SIZE ON JOINT DISPLACEMENT
OF BUILDING
Shivendra Nath Mishra, M.C. Paliwal
1Student ME, Department of Civil & Environmental Engineering, NITTTR Bhopal-462002, Madhya Pradesh, India
2Professor, Department of Civil & Environmental Engineering, NITTTR Bhopal-462002, Madhya Pradesh, India
---------------------------------------------------------------------***----------------------------------------------------------------------
Abstract - This analysis has been executed to examine the
wind force influence on high rise multistoried building on
different levels or floors. For this analysis we have taken G+7
building located on high velocity wind area like Delhi. Where
normal basic wind speed is 47 m/sec as per IS 875: part iii. As
we know that the effect of wind is greater in high rise building
so we should always review the effect of wind load while
designing multistory buildings. All around the world, there is
heavy requirement for constructionoftallmultistorybuildings
due to increasing urbanizationand increasingpopulation, and
wind force has the potential for causing the heavy damages to
tall structures. Since wind forces are random in nature, the
engineering tools needtobeimprovedforanalyzingstructures
under the action of wind forces.
This analysis put forward to introduce deflection of nodes of
building due to wind pressure by using computersoftwarelike
Staad pro and by this analysis we can find deflection, shear
force, bending moment, axial forces on beams and columns of
building due to combination of static load and wind load.
Key Words: Wind Pressure, Displacement, Multi-storey,
Dynamic load, storey shear,Structural design,Staad pro.
1. INTRODUCTION
Now these days high rise multistoried buildings are
extensively adopted in urban areas all over the earth due to
the increase in urban population, contraction of land & its
high cost. But main consideration is that as the height of
structure increases vertically it is widely affected by lateral
loads. These lateral loads are mainly in theformofwindload
& earthquake load. So, efficient design approach & advance
construction techniques are adopted to guard the tall
buildings from wind load & earthquake load. Many
researches have been done to increase the safety of tall
buildings against these loads. So it is essential tostudyabout
the behavior of structures with these loads and their effect
on multistory in terms of different parameters & thereby
finding most suitable design for multistory. Wind forces in
normal circumstances principally govern the structural
design when building heights are above 100-150 m. Though
the other force which effect the majority on high rise
building are the lateral forces produced by earthquakes or
seismic forces.
Fig 1: Effect of wind on tall structures
1.1Wind load and pressure calculations
IS: 875 (Part iii) of Indian standard and practice is used to
check and design loads for structures ,this standard code
govern wind forces and their effects which ought to be
thought into consideration while planning design of
building and structures. The sustainability of any building
or any other structure to high wind pressure depends on
geographical location, air flow direction and obstruction as
well as buildings characters itself.
Design Speed of wind (Vz): Basic speed of wind (Vb) for any
area or location can be found and adjusted to take wind
effects to determine designed velocity of wind at any
elevation (Vz) for the selected buildings:
a) Risk or Hazard level;
b) Topography roughness, size and height of the
structure
c) Local topography.
These factors are expressed mathematically as follows:
Basic speed of wind Vz = Vb× k1×k2× k3
Where: Vz = designed speed of wind at any elevation z at
chosen location;
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1773
K1 = probability/Risk coefficient or factor
K2 = topography, structure dimension factor and height
factor
K3 = topography (terrain) factor
In our case the basic wind speed (Vb) = 47 m/sec.
Design wind pressure: The design wind pressure for any
elevation above mean ground level can be determined by
the succeeding connection between wind pressures along
with wind velocity;
Pz = 0.60Vz
2
Where
Pz : designed wind pressure at any given elevation z in
N/m2
Vz: designed wind velocity at any given elevation z in m/s
2. LITERATURE REVIEW
Ashish Sadh, Ankit Pal, (2018): This study shows the
behavior of high rise building against the wind force in
building situated in Indore, L shape of the structure was
studied and analyzed for specific heights. They used staad
pro software for this analysis purpose. They taken a G+19
floors building for this study and also analyzed about
different material like RCC or composite material to study
behavior against wind loads on building.
Mrs. Gitadevi B. Bhaskar, Miss. Homeshwari V.Gedam,
(2018): This study give emphasis on the wind load effect on
building with changing aspect ratios i.e. Height/width(H/B)
ratio, by using STADD PRO. From this study we got the
assessment on the outcomes of wind load on buildingheight
by changing the total number of stories while increasing the
Aspect Ratio.
SandeepTembhurkar, Dr.ValssonVarghese(2014): They
calculated and compared the wind load manually with the
help of IS 875, part 3 and compared the critical value of axial
forces and bending moments forG+19,G+24andG+29floors
buildings. Hence they found that wind forces were more
critical for tall structures i.e. for G+29 floor building.
Structures should be designed for loads obtained in both
directions independently for critical forces of wind.
Narla Mohan et al. (2017): In this analysis seismic & wind
analysis was performed on G+ 20 storeysRCbuildingsquare
in shape with four different zones II, III, IV & V. The analysis
was done by adopting using ETAB software adopting
response spectrum analysismethod&windanalysisasperIS
875-1987 part-III. Four models were used for analysis with
different bay lengths. The evaluation has been done by
taking the parameters like storey shear, storey drift,
torsional force & displacement. It was found that the storey
drift due to wind load is mainly occurred at the middleofthe
building structure. Storey Shear is decreased as building
height was increased and decreased at top floor in all the
building models.
3. BUILDING GEOMETRY AND STRUCTURAL
PROPERTY
 Type of structure : multi-storey fixed jointed frame
of G+6 storey
 Seismic zone IV IS 1893 (part 1):2002
 Supports ; Fixed end support
 Number of stories 7, (G+6).
 Materials Concrete (M 30) and Reinforcement
(Fe500).
 Specific weight of RCC 25kn/m3.
Building Dimensions:
Length: 10 m Width: 10 m Height: 21 m
Size of beam: 300 mm x 450 mm (For both models)
Size of column: 500 mm x 500 mm (For model 1)
Size of column: 600 mm x 600 mm (For model 2)
Fig 1: Geometry of structure
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1774
Fig -2: Dimensions for Beam & Column for Model 1
Fig -3: Dimensions for Beam & Column for Model 2
4. RESULTS AND CONCLUSION
Wind forces in normal circumstances principally govern the
structural design when building heights are above 100-150
m. Though the other force which effect the majority on high
rise building are the lateral forces produced by earthquakes
or seismic forces. When buildings start to be taller, they
become flexible and they move away from the high
frequency waves. This analysis or project describes wind
analysis of high-rise structure in several zones of Indian
subcontinent.
The structure located on Delhi town (Zone4)wasassociated
to self weight or dead load and intensities of wind loads
were generated by taking into account the known wind
intensities at diverse elevations and firmly follow by the
specifications of IS 875: part iii (1987). After wind pressure
manual input we can click on assign to view option on Staad
pro to view effect of wind on multistory. Windforcehasbeen
applied in X , -X , Z and –Z directions for both structures.
After analysing wind load in X and Z direction on both type
of structure, value of maximum node displacement, shear
force, bending moments were compared with respect to
increasing size of the columns by 20%. For model 1 we have
taken 500mm*500mm column and for model 2 we have
taken 600mm*600mm column. Maximum relative node
displacement for model 1 and model 2 is as following:
Table 1: Displacement values in mm at different levels of
floors for model 1
Table 2: Displacement values in mm at different levels of
floors for model 2
Floor Level Max
Displace
ment @
Corner
(mm)
Max
Displace
ment @edge
(mm)
Max
Displace
ment
@Center
(mm)
7th
floor
21 m 9.308 mm 9.845 mm 9.830 mm
6th
floor
18 m 8.710 mm 9.281 mm 9.258 mm
5th
floor
15 m 7.761 mm 8.330 mm 8.307mm
Floor Level Max Displace
ment @
Corner(mm)
Max
Displace
ment @edge
(mm)
Max
Displacem
ent
@Center
(mm)
7th 21 m 11.194 mm 11.728 mm 11.713mm
6th 18 m 10.624 mm 11.206 mm 11.182mm
5th 15 m 9.602 mm 10.190 mm 10.167mm
4th 12 m 8.076 mm 8.625 mm 8.604 mm
3rd 9 m 6.082 mm 6.549 mm 6.529 mm
2nd 6 m 3.737 mm 4.066 mm 4.048 mm
1st 3 m 1.365 mm 1.500 mm 1.495 mm
International Research Journal of Engineering and Technology (IRJET) e-ISSN: 2395-0056
Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072
© 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1775
4th
floor
12 m 6.409 mm 6.932 mm 6.911 mm
3rd
floor
9 m 4.697 mm 5.128 mm 5.109 mm
2nd
floor
6 m 2.765 mm 3.054 mm 3.037 mm
1st
floor
3 m 0.941 mm 1.052 mm 1.057 mm
After comparison of both models of multistorey it has been
shown that when we have increased ourcolumndimensions
up to 20% in both dimensions. The value of nodal
displacement has been decreased for model 2 from 17% to
31%. Whereas the reduction in nodal displacement was
more on bottom floors as compared to top floors of the
building.
With the help of Post processing result of software and the
table above we can conclude that with the height of
multistory the nodal displacement magnitudealsoincreases
and the bending moment for the beam becomes more
serious at the top in comparison to the lower part of the
structure. That defines the more effectiveness and intensity
of wind load at the higher portion of the building.
This study/analysis was conceded out with only wind load
was considered as dynamic load. Different load cases and
combination can be considered further with different kinds
of loading for a multistoried building dynamic loadsanalysis
to check its effect on multistory.
REFERENCES
[1] IS 875 (Part 3 Wind Load) -1987 Code of Practice for
Design Loads (Other than Earthquake) For Buildings
and Structures, Bureau of Indian Standards, New Delhi.
[2] SandeepTembhurkar1,Dr.ValssonVarghese-Review
of Critical Analysis of Frame Building Structureby Wind
Force: IOSR Journal of Mechanical and Civil Engineering
(IOSR-JMCE) e-ISSN: 2278-1684,p-ISSN: 2320-334X,
Volume 11, Issue 3 Ver. IV (May- Jun. 2014), PP 32-38
www.iosrjournals.org
[3] Narla Mohan, A.Mounika Vardhan- Analysis of G+20
RC Building in Different Seismic Zones using ETABS
international journal of professional engineering
studies, Volume VIII /Issue 3 / mar 2017.
[4] Mrs. Gitadevi B. Bhaskar, Miss. Homeshwari
V.Gedam, (2018); Effect of Wind Load on High Rise
Buildings Considering Aspect Ratio Volume 6, Issue VI,
June 2018, International Journal forResearchinApplied
Science & Engineering Technology.
[5] Ashish Sadh1 , Ankit Pal2 A Literature Study of Wind
Analysis on High Rise Building, International Journal of
Advanced Engineering Research and
Science,(IJAERS),[Vol-5,Issue-11,Nov-018]
https://dx.doi.org/10.22161/ijaers.5.11.36
[6] Alhamd Farqaleet, “Dynamic Analysis of Multistory
RCC Building” International Journal of Innovative
Research in Technology (IJIRT), Vol. 3 Issue 3, pp. 140-
146, 2016
[7] National building code (2004)
[8] Software STAAD pro v8i

IRJET- Effect of Different Column Size on Joint Displacement of Building

  • 1.
    International Research Journalof Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1772 EFFECT OF DIFFERENT COLUMN SIZE ON JOINT DISPLACEMENT OF BUILDING Shivendra Nath Mishra, M.C. Paliwal 1Student ME, Department of Civil & Environmental Engineering, NITTTR Bhopal-462002, Madhya Pradesh, India 2Professor, Department of Civil & Environmental Engineering, NITTTR Bhopal-462002, Madhya Pradesh, India ---------------------------------------------------------------------***---------------------------------------------------------------------- Abstract - This analysis has been executed to examine the wind force influence on high rise multistoried building on different levels or floors. For this analysis we have taken G+7 building located on high velocity wind area like Delhi. Where normal basic wind speed is 47 m/sec as per IS 875: part iii. As we know that the effect of wind is greater in high rise building so we should always review the effect of wind load while designing multistory buildings. All around the world, there is heavy requirement for constructionoftallmultistorybuildings due to increasing urbanizationand increasingpopulation, and wind force has the potential for causing the heavy damages to tall structures. Since wind forces are random in nature, the engineering tools needtobeimprovedforanalyzingstructures under the action of wind forces. This analysis put forward to introduce deflection of nodes of building due to wind pressure by using computersoftwarelike Staad pro and by this analysis we can find deflection, shear force, bending moment, axial forces on beams and columns of building due to combination of static load and wind load. Key Words: Wind Pressure, Displacement, Multi-storey, Dynamic load, storey shear,Structural design,Staad pro. 1. INTRODUCTION Now these days high rise multistoried buildings are extensively adopted in urban areas all over the earth due to the increase in urban population, contraction of land & its high cost. But main consideration is that as the height of structure increases vertically it is widely affected by lateral loads. These lateral loads are mainly in theformofwindload & earthquake load. So, efficient design approach & advance construction techniques are adopted to guard the tall buildings from wind load & earthquake load. Many researches have been done to increase the safety of tall buildings against these loads. So it is essential tostudyabout the behavior of structures with these loads and their effect on multistory in terms of different parameters & thereby finding most suitable design for multistory. Wind forces in normal circumstances principally govern the structural design when building heights are above 100-150 m. Though the other force which effect the majority on high rise building are the lateral forces produced by earthquakes or seismic forces. Fig 1: Effect of wind on tall structures 1.1Wind load and pressure calculations IS: 875 (Part iii) of Indian standard and practice is used to check and design loads for structures ,this standard code govern wind forces and their effects which ought to be thought into consideration while planning design of building and structures. The sustainability of any building or any other structure to high wind pressure depends on geographical location, air flow direction and obstruction as well as buildings characters itself. Design Speed of wind (Vz): Basic speed of wind (Vb) for any area or location can be found and adjusted to take wind effects to determine designed velocity of wind at any elevation (Vz) for the selected buildings: a) Risk or Hazard level; b) Topography roughness, size and height of the structure c) Local topography. These factors are expressed mathematically as follows: Basic speed of wind Vz = Vb× k1×k2× k3 Where: Vz = designed speed of wind at any elevation z at chosen location;
  • 2.
    International Research Journalof Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1773 K1 = probability/Risk coefficient or factor K2 = topography, structure dimension factor and height factor K3 = topography (terrain) factor In our case the basic wind speed (Vb) = 47 m/sec. Design wind pressure: The design wind pressure for any elevation above mean ground level can be determined by the succeeding connection between wind pressures along with wind velocity; Pz = 0.60Vz 2 Where Pz : designed wind pressure at any given elevation z in N/m2 Vz: designed wind velocity at any given elevation z in m/s 2. LITERATURE REVIEW Ashish Sadh, Ankit Pal, (2018): This study shows the behavior of high rise building against the wind force in building situated in Indore, L shape of the structure was studied and analyzed for specific heights. They used staad pro software for this analysis purpose. They taken a G+19 floors building for this study and also analyzed about different material like RCC or composite material to study behavior against wind loads on building. Mrs. Gitadevi B. Bhaskar, Miss. Homeshwari V.Gedam, (2018): This study give emphasis on the wind load effect on building with changing aspect ratios i.e. Height/width(H/B) ratio, by using STADD PRO. From this study we got the assessment on the outcomes of wind load on buildingheight by changing the total number of stories while increasing the Aspect Ratio. SandeepTembhurkar, Dr.ValssonVarghese(2014): They calculated and compared the wind load manually with the help of IS 875, part 3 and compared the critical value of axial forces and bending moments forG+19,G+24andG+29floors buildings. Hence they found that wind forces were more critical for tall structures i.e. for G+29 floor building. Structures should be designed for loads obtained in both directions independently for critical forces of wind. Narla Mohan et al. (2017): In this analysis seismic & wind analysis was performed on G+ 20 storeysRCbuildingsquare in shape with four different zones II, III, IV & V. The analysis was done by adopting using ETAB software adopting response spectrum analysismethod&windanalysisasperIS 875-1987 part-III. Four models were used for analysis with different bay lengths. The evaluation has been done by taking the parameters like storey shear, storey drift, torsional force & displacement. It was found that the storey drift due to wind load is mainly occurred at the middleofthe building structure. Storey Shear is decreased as building height was increased and decreased at top floor in all the building models. 3. BUILDING GEOMETRY AND STRUCTURAL PROPERTY  Type of structure : multi-storey fixed jointed frame of G+6 storey  Seismic zone IV IS 1893 (part 1):2002  Supports ; Fixed end support  Number of stories 7, (G+6).  Materials Concrete (M 30) and Reinforcement (Fe500).  Specific weight of RCC 25kn/m3. Building Dimensions: Length: 10 m Width: 10 m Height: 21 m Size of beam: 300 mm x 450 mm (For both models) Size of column: 500 mm x 500 mm (For model 1) Size of column: 600 mm x 600 mm (For model 2) Fig 1: Geometry of structure
  • 3.
    International Research Journalof Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1774 Fig -2: Dimensions for Beam & Column for Model 1 Fig -3: Dimensions for Beam & Column for Model 2 4. RESULTS AND CONCLUSION Wind forces in normal circumstances principally govern the structural design when building heights are above 100-150 m. Though the other force which effect the majority on high rise building are the lateral forces produced by earthquakes or seismic forces. When buildings start to be taller, they become flexible and they move away from the high frequency waves. This analysis or project describes wind analysis of high-rise structure in several zones of Indian subcontinent. The structure located on Delhi town (Zone4)wasassociated to self weight or dead load and intensities of wind loads were generated by taking into account the known wind intensities at diverse elevations and firmly follow by the specifications of IS 875: part iii (1987). After wind pressure manual input we can click on assign to view option on Staad pro to view effect of wind on multistory. Windforcehasbeen applied in X , -X , Z and –Z directions for both structures. After analysing wind load in X and Z direction on both type of structure, value of maximum node displacement, shear force, bending moments were compared with respect to increasing size of the columns by 20%. For model 1 we have taken 500mm*500mm column and for model 2 we have taken 600mm*600mm column. Maximum relative node displacement for model 1 and model 2 is as following: Table 1: Displacement values in mm at different levels of floors for model 1 Table 2: Displacement values in mm at different levels of floors for model 2 Floor Level Max Displace ment @ Corner (mm) Max Displace ment @edge (mm) Max Displace ment @Center (mm) 7th floor 21 m 9.308 mm 9.845 mm 9.830 mm 6th floor 18 m 8.710 mm 9.281 mm 9.258 mm 5th floor 15 m 7.761 mm 8.330 mm 8.307mm Floor Level Max Displace ment @ Corner(mm) Max Displace ment @edge (mm) Max Displacem ent @Center (mm) 7th 21 m 11.194 mm 11.728 mm 11.713mm 6th 18 m 10.624 mm 11.206 mm 11.182mm 5th 15 m 9.602 mm 10.190 mm 10.167mm 4th 12 m 8.076 mm 8.625 mm 8.604 mm 3rd 9 m 6.082 mm 6.549 mm 6.529 mm 2nd 6 m 3.737 mm 4.066 mm 4.048 mm 1st 3 m 1.365 mm 1.500 mm 1.495 mm
  • 4.
    International Research Journalof Engineering and Technology (IRJET) e-ISSN: 2395-0056 Volume: 06 Issue: 11 | Nov 2019 www.irjet.net p-ISSN: 2395-0072 © 2019, IRJET | Impact Factor value: 7.34 | ISO 9001:2008 Certified Journal | Page 1775 4th floor 12 m 6.409 mm 6.932 mm 6.911 mm 3rd floor 9 m 4.697 mm 5.128 mm 5.109 mm 2nd floor 6 m 2.765 mm 3.054 mm 3.037 mm 1st floor 3 m 0.941 mm 1.052 mm 1.057 mm After comparison of both models of multistorey it has been shown that when we have increased ourcolumndimensions up to 20% in both dimensions. The value of nodal displacement has been decreased for model 2 from 17% to 31%. Whereas the reduction in nodal displacement was more on bottom floors as compared to top floors of the building. With the help of Post processing result of software and the table above we can conclude that with the height of multistory the nodal displacement magnitudealsoincreases and the bending moment for the beam becomes more serious at the top in comparison to the lower part of the structure. That defines the more effectiveness and intensity of wind load at the higher portion of the building. This study/analysis was conceded out with only wind load was considered as dynamic load. Different load cases and combination can be considered further with different kinds of loading for a multistoried building dynamic loadsanalysis to check its effect on multistory. REFERENCES [1] IS 875 (Part 3 Wind Load) -1987 Code of Practice for Design Loads (Other than Earthquake) For Buildings and Structures, Bureau of Indian Standards, New Delhi. [2] SandeepTembhurkar1,Dr.ValssonVarghese-Review of Critical Analysis of Frame Building Structureby Wind Force: IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-ISSN: 2278-1684,p-ISSN: 2320-334X, Volume 11, Issue 3 Ver. IV (May- Jun. 2014), PP 32-38 www.iosrjournals.org [3] Narla Mohan, A.Mounika Vardhan- Analysis of G+20 RC Building in Different Seismic Zones using ETABS international journal of professional engineering studies, Volume VIII /Issue 3 / mar 2017. [4] Mrs. Gitadevi B. Bhaskar, Miss. Homeshwari V.Gedam, (2018); Effect of Wind Load on High Rise Buildings Considering Aspect Ratio Volume 6, Issue VI, June 2018, International Journal forResearchinApplied Science & Engineering Technology. [5] Ashish Sadh1 , Ankit Pal2 A Literature Study of Wind Analysis on High Rise Building, International Journal of Advanced Engineering Research and Science,(IJAERS),[Vol-5,Issue-11,Nov-018] https://dx.doi.org/10.22161/ijaers.5.11.36 [6] Alhamd Farqaleet, “Dynamic Analysis of Multistory RCC Building” International Journal of Innovative Research in Technology (IJIRT), Vol. 3 Issue 3, pp. 140- 146, 2016 [7] National building code (2004) [8] Software STAAD pro v8i