Measurement of Flow
Mathematics of Flow Rate
• The Scalar Product of two vectors, namely velocity and
area..
Important characteristics of the dot product
• The first point to note about the definition is that the
coordinate system does not enter the definition.
• The second point to note is that because cos=cos(-, the
order is not important, that is, the scalar product is
commutative.
• The scalar product is also distributive.
• All these qualities help in development of a single
instrument to measure the scalar product.
Types of Flow Measurement Technologies
• Variable Area (rotameters)
• Rotating Vane (paddle & turbine)
• Positive Displacement
• Differential Pressure
• Vortex Shedding
• Thermal Dispersion
• Magnetic Magnetic
• Thermal Mass
• Coriolis Mass
• Ultrasonic
Measurement of flow in metrology & Measurement.ppt
Some Facts About Variable Area Flowmeters
• Called “float type float
type”, “rotameter’’, or
“variable area” flowmeters.
• By far the most common
specified, purchased, and
installed flowmeter in the
world
Variable Area Flowmeters
• Fluid flow moves the float
upward against gravity.
• Float will find equilibrium when
area around float generates
enough drag equal to weight -
buoyancy.
• Some types have a guide rod to
keep float stable.
• Low Cost (pricing usually starts
< $50)
• Simple Reliable Design
• Can Measure Liquid or Gas
Flows
• Tolerates Dirty Liquids or Solids
in Liquid
Measuring Principles of Variable Area Flowmeters
• Flow Rate Analysis.
• The forces acting on the bob lead to equilibrium between:
• the weight of the bob bgVb acting downwards
• the buoyancy force gVb and
• the drag force Fd acting upwards.
• Where Vb is the volume and
 b is the density of the bob,
  is the density of the fluid, and
• g is the gravitational acceleration:
d
b
b
b F
gV
gV 


• The drag force results from the flow field surrounding the bob
and particularly from the wake of the bob.
• In flow analyses based on similarity principles, these influences
are accounted for by empirical coefficient CL or CT in the drag
law for:
2
2
Flow,
Turbulent U
D
C
F b
T
d 

U
D
C
F b
L
d 

Flow,
Laminar
The volume flow rate through the rotameter is:
Where m is the open area ratio, defined as:
And D is the tube diameter at the height of the bob.
d
b
b
b F
gV
gV 


where the parameter  is defined in terms of a constant
K =Vb/D3
b characteristic of the shape of the bob:
for turbulent flow:
for laminar flow:
With either laminar or turbulent flow through the rotameter, the
flow rate is proportional to m.
If the cross-sectional area of the tube is made to increase linearly
with length, i.e.,
then since the cone angle
 of the tube is small,
and the flow rate is directly
proportional to the height h
of the bob. h
Similarity Analysis.
• The basic scaling parameter for flow is the Reynolds number,
defined as:
•where UIN is the velocity at the rotameter inlet, and the tube diameter
D is represented by its value at the inlet, equal to the bob diameter Db.
• Through the Reynolds number regimes of laminar or turbulent flow,
and particularly important for the rotameter flow regimes with strong
or weak viscosity dependence can be distinguished.
•It has been found to be practical for rotameters to use an alternative
characteristic number, the Ruppel number, defined as:
where mb = bD3
b is the mass of the bob.
By combining Equations, the mass flow through the rotameter
can be written as:
The relationship between the Ruppel number and the Reynolds
number:
The advantage of the Ruppel number is its independence of the flow rate.
Since the Ruppel number contains only fluid properties and the mass and
the density of the bob, it is a constant for a particular instrument.
Design Charts for Laminar Rotameters
Design Charts for Turbulent Rotameters
Measurement of flow in metrology & Measurement.ppt
(1) End fitting — flange
shown;
(2) flowmeter body;
(3) rotation pickup —
magnetic, reluctancetype
shown;
(4) permanent magnet;
(5) pickup cold wound on
pole piece;
(6) rotor blade;
(7) rotor hub;
(8) Rotor shaft bearing —
journal type shown;
(9) rotor shaft;
(10) diffuser support and flow
straightener;
(11) diffuser;
(12) flow conditioning plate
(dotted) — optional with
some meters.
Measurement of flow in metrology & Measurement.ppt
Measurement of flow in metrology & Measurement.ppt
Theory
• There are two approaches described in the current
literature for analyzing axial turbine performance.
• The first approach describes the fluid driving torque in
terms of momentum exchange, while the second describes
it in terms of aerodynamic lift via airfoil theory.
• The former approach has the advantage that it readily
produces analytical results describing basic operation,
some of which have not appeared via airfoil analysis.
• The latter approach has the advantage that it allows more
complete descriptions using fewer approximations.
• However, it is mathematically intensive and leads rapidly
into computer-generated solutions.
Eliminating the time dimension from the left-hand-side quantity
reduces it to the number of rotor rotations per unit fluid volume,
which is essentially the flowmeter K factor specified by most
manufacturers.
• In the ideal situation, the meter response is perfectly linear and
determined only by geometry.
• In some flowmeter designs, the rotor blades are helically twisted to
improve efficiency.
• This is especially true of blades with large radius ratios, (R/a).
• If the flow velocity profile is assumed to be flat, then the blade
angle in this case can be described by tan  = Constant X r.
• This is sometimes called the “ideal” helical blade.
• In practice, there are instead a number of rotor retarding torques of
varying relative magnitudes.
• Under steady flow, the rotor assumes a speed that satisfies the
following equilibrium:
• The difference between the actual rotor speed, r, and the ideal
rotor speed, ri , is the rotor slip velocity due to the combined
effect of all the rotor retarding torques , and as a result of
which the fluid velocity vector is deflected through an exit or
swirl angle, .
• Denoting the radius variable by r, and equating the total rate of
change of angular momentum of the fluid passing through the
rotor to the retarding torque, one obtains:
NT is the total retarding torque
Industrial Correlations for Frictional Losses
Electromagnetic Flowmeters
• Magnetic flowmeters have been widely used in industry for many
years.
• Unlike many other types of flowmeters, they offer true
noninvasive measurements.
• They are easy to install and use to the extent that existing pipes
in a process can be turned into meters simply by adding external
electrodes and suitable magnets.
• They can measure reverse flows and are insensitive to viscosity,
density, and flow disturbances.
• Electromagnetic flowmeters can rapidly respond to flow changes
and they are linear devices for a wide range of measurements.
• As in the case of many electric devices, the underlying principle
of the electromagnetic flowmeter is Faraday’s law of
electromagnetic induction.
• The induced voltages in an electromagnetic flowmeter are
linearly proportional to the mean velocity of liquids or to the
volumetric flow rates.
• As is the case in many applications, if the pipe walls are made
from nonconducting elements, then the induced voltage is
independent of the properties of the fluid.
• The accuracy of these meters can be as low as 0.25% and, in most
applications, an accuracy of 1% is used.
• At worst, 5% accuracy is obtained in some difficult applications
where impurities of liquids and the contact resistances of the
electrodes are inferior as in the case of low-purity sodium liquid
solutions.
• Faraday’s Law of Induction
• This law states that if a conductor of length l (m) is moving with a
velocity v (m/s–1
), perpendicular to a magnetic field of flux density
B (Tesla), then the induced voltage e across the ends of conductor
can be expressed by:
Blv
e 
The velocity of the conductor is
proportional to the mean flow velocity
of the liquid.
Hence, the induced voltage becomes:
BDv
e 
BDv
e 
v
D
Av
Q 2
4



D
BQ
e

4

Measurement of flow in metrology & Measurement.ppt
Ultrasonic Flowmeters
• There are various types of ultrasonic flowmeters in use for
discharge measurement:
• (1) Transit time: This is today’s state-of-the-art technology and
most widely used type.
• This type of ultrasonic flowmeter makes use of the difference
in the time for a sonic pulse to travel a fixed distance.
• First against the flow and then in the direction of flow.
• Transmit time flowmeters are sensitive to suspended solids or
air bubbles in the fluid.
• (2) Doppler: This type is more popular and less expensive, but
is not considered as accurate as the transit time flowmeter.
• It makes use of the Doppler frequency shift caused by sound
reflected or scattered from suspensions in the flow path and is
therefore more complementary than competitive to transit time
flowmeters.
Principle of transit time flowmeters.
Transit Time Flowmeter
• Principle of Operation
• The acoustic method of discharge measurement is based on the
fact that the propagation velocity of an acoustic wave and the
flow velocity are summed vectorially.
• This type of flowmeter measures the difference in transit times
between two ultrasonic pulses transmitted upstream t21 and
downstream t12 across the flow.
• If there are no transverse flow components in the conduit, these
two transmit times of acoustic pulses are given by:
Since the transducers are generally used both as transmitters and
receivers, the difference in travel time can be determined with the
same pair of transducers.
Thus, the mean axial velocity along the path is given by:
Example
• The following example shows the demands on the time
measurement technique:
• Assume a closed conduit with diameter D = 150 mm, angle =
60°, flow velocity = 1 m/s, and water temperature =20°C.
• This results in transmit times of about 116 s and a time
difference
 t =t12 – t21 on the order of 78 ns.
• To achieve an accuracy of 1% of the corresponding full-scale
range, t has to be measured with a resolution of at least 100 ps
(1X10–10
s).
• Standard time measurement techniques are not able to meet such
requirements so that special techniques must be applied.
• Digital timers with the state-of-the –art Micro computers will
make it possible to measure these time difference.
Measurement of flow in metrology & Measurement.ppt
Point Velocity Measurement
• Pitot Probe Anemometry : Potential Flow Theory &
Bernoulli’s Theory .
• Thermal Anemometry : Newton’s Law of Cooling.
• Laser Anemometry: Doppler Theory.

More Related Content

PPT
Flow dynamics for different fluids behaviour
PPT
Mathematics of Flow Rate and flow measurement
PPT
mel705-27.ppt
PDF
Friction losses in turbulent flow (Fanning Equation).pdf
PPS
Basic flow measurement
PPT
Flow Measurement
PPT
Basic Instrument Presentation ( Flow )
PPT
MECH 591 Instrumentation and Measurement Flow Measurements.ppt
Flow dynamics for different fluids behaviour
Mathematics of Flow Rate and flow measurement
mel705-27.ppt
Friction losses in turbulent flow (Fanning Equation).pdf
Basic flow measurement
Flow Measurement
Basic Instrument Presentation ( Flow )
MECH 591 Instrumentation and Measurement Flow Measurements.ppt

Similar to Measurement of flow in metrology & Measurement.ppt (20)

PDF
Flow measurement part III
PPTX
Ultrasonic flow measurement
PPT
various flow meter
PPTX
Flow measurement in industries
PPTX
Design Of Flow Meters
PDF
CH28.PDF
PPTX
Stream flow measurement
PDF
streamflowmeasurement-170307185522.pdf
PDF
Instrumentation in oil refinery
PPT
Present buk
PDF
Fluid mechanics for chermical engineering students
PPTX
Flow sensors
PPTX
Asr flow measurement
PPT
Asr wastewater characteristics
PPTX
Wastewater characteristics
PPTX
Stream flow measurement
DOCX
Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
PPTX
A study on Nonlinear flow through an orifice meter
PPTX
Flow Measurnment
PPTX
Unit41.pptx
Flow measurement part III
Ultrasonic flow measurement
various flow meter
Flow measurement in industries
Design Of Flow Meters
CH28.PDF
Stream flow measurement
streamflowmeasurement-170307185522.pdf
Instrumentation in oil refinery
Present buk
Fluid mechanics for chermical engineering students
Flow sensors
Asr flow measurement
Asr wastewater characteristics
Wastewater characteristics
Stream flow measurement
Rev. August 2014 ME495 - Pipe Flow Characteristics… Page .docx
A study on Nonlinear flow through an orifice meter
Flow Measurnment
Unit41.pptx
Ad

More from Bikash Choudhuri (20)

PPT
Introduction-to-Automation for mechanical.ppt
PPTX
Workshop-Practise , basics of machines.pptx
PPT
Flow Measurement chapter in metrology .ppt
PPT
Overview of Temperature Measurement devices
PPT
Measurement and Instrumentations of temperature
PPT
Classification of different types Gauges.ppt
PPT
Metrology and Gauging Dynamic Characteristics.ppt
PPT
Extrusion and Drawing forming process.ppt
PPTX
Natural particle reinforced composite.pptx
PPT
Robot Sensing, Sensors used in industrial applications.ppt
PPT
Gripper mechanism for Robotic arm design .ppt
PPT
Basics of Robotics Griper and lifting mechanism
PPTX
Form metrology Thread measurement in metrology.pptx
PPT
Form Metrology: screw thread measurement.ppt
PPTX
Tool metrology tool life for metrology.pptx
PPSX
Research methodology: Paper Writing_PSahoo.ppsx
PPT
optical microscope and its details working.ppt
PPTX
pert & CPM in production Engg an Operation Research
PPT
Surface tread measurement of screw thread
PPT
LVDT i.e Linear Variable differential transducer.ppt
Introduction-to-Automation for mechanical.ppt
Workshop-Practise , basics of machines.pptx
Flow Measurement chapter in metrology .ppt
Overview of Temperature Measurement devices
Measurement and Instrumentations of temperature
Classification of different types Gauges.ppt
Metrology and Gauging Dynamic Characteristics.ppt
Extrusion and Drawing forming process.ppt
Natural particle reinforced composite.pptx
Robot Sensing, Sensors used in industrial applications.ppt
Gripper mechanism for Robotic arm design .ppt
Basics of Robotics Griper and lifting mechanism
Form metrology Thread measurement in metrology.pptx
Form Metrology: screw thread measurement.ppt
Tool metrology tool life for metrology.pptx
Research methodology: Paper Writing_PSahoo.ppsx
optical microscope and its details working.ppt
pert & CPM in production Engg an Operation Research
Surface tread measurement of screw thread
LVDT i.e Linear Variable differential transducer.ppt
Ad

Recently uploaded (20)

PPTX
Wireless sensor networks (WSN) SRM unit 2
PPTX
Environmental studies, Moudle 3-Environmental Pollution.pptx
PPTX
Software Engineering and software moduleing
PPTX
CN_Unite_1 AI&DS ENGGERING SPPU PUNE UNIVERSITY
PPT
UNIT-I Machine Learning Essentials for 2nd years
PDF
Computer organization and architecuture Digital Notes....pdf
PDF
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
PPTX
Solar energy pdf of gitam songa hemant k
PPTX
Principal presentation for NAAC (1).pptx
PDF
Computer System Architecture 3rd Edition-M Morris Mano.pdf
PDF
August -2025_Top10 Read_Articles_ijait.pdf
PDF
[jvmmeetup] next-gen integration with apache camel and quarkus.pdf
PDF
electrical machines course file-anna university
PDF
Design of Material Handling Equipment Lecture Note
PPTX
AI-Reporting for Emerging Technologies(BS Computer Engineering)
PDF
UEFA_Carbon_Footprint_Calculator_Methology_2.0.pdf
PDF
Principles of operation, construction, theory, advantages and disadvantages, ...
PPTX
Management Information system : MIS-e-Business Systems.pptx
PPTX
ASME PCC-02 TRAINING -DESKTOP-NLE5HNP.pptx
PDF
Unit I -OPERATING SYSTEMS_SRM_KATTANKULATHUR.pptx.pdf
Wireless sensor networks (WSN) SRM unit 2
Environmental studies, Moudle 3-Environmental Pollution.pptx
Software Engineering and software moduleing
CN_Unite_1 AI&DS ENGGERING SPPU PUNE UNIVERSITY
UNIT-I Machine Learning Essentials for 2nd years
Computer organization and architecuture Digital Notes....pdf
UEFA_Embodied_Carbon_Emissions_Football_Infrastructure.pdf
Solar energy pdf of gitam songa hemant k
Principal presentation for NAAC (1).pptx
Computer System Architecture 3rd Edition-M Morris Mano.pdf
August -2025_Top10 Read_Articles_ijait.pdf
[jvmmeetup] next-gen integration with apache camel and quarkus.pdf
electrical machines course file-anna university
Design of Material Handling Equipment Lecture Note
AI-Reporting for Emerging Technologies(BS Computer Engineering)
UEFA_Carbon_Footprint_Calculator_Methology_2.0.pdf
Principles of operation, construction, theory, advantages and disadvantages, ...
Management Information system : MIS-e-Business Systems.pptx
ASME PCC-02 TRAINING -DESKTOP-NLE5HNP.pptx
Unit I -OPERATING SYSTEMS_SRM_KATTANKULATHUR.pptx.pdf

Measurement of flow in metrology & Measurement.ppt

  • 2. Mathematics of Flow Rate • The Scalar Product of two vectors, namely velocity and area..
  • 3. Important characteristics of the dot product • The first point to note about the definition is that the coordinate system does not enter the definition. • The second point to note is that because cos=cos(-, the order is not important, that is, the scalar product is commutative. • The scalar product is also distributive. • All these qualities help in development of a single instrument to measure the scalar product.
  • 4. Types of Flow Measurement Technologies • Variable Area (rotameters) • Rotating Vane (paddle & turbine) • Positive Displacement • Differential Pressure • Vortex Shedding • Thermal Dispersion • Magnetic Magnetic • Thermal Mass • Coriolis Mass • Ultrasonic
  • 6. Some Facts About Variable Area Flowmeters • Called “float type float type”, “rotameter’’, or “variable area” flowmeters. • By far the most common specified, purchased, and installed flowmeter in the world
  • 7. Variable Area Flowmeters • Fluid flow moves the float upward against gravity. • Float will find equilibrium when area around float generates enough drag equal to weight - buoyancy. • Some types have a guide rod to keep float stable. • Low Cost (pricing usually starts < $50) • Simple Reliable Design • Can Measure Liquid or Gas Flows • Tolerates Dirty Liquids or Solids in Liquid
  • 8. Measuring Principles of Variable Area Flowmeters • Flow Rate Analysis. • The forces acting on the bob lead to equilibrium between: • the weight of the bob bgVb acting downwards • the buoyancy force gVb and • the drag force Fd acting upwards. • Where Vb is the volume and  b is the density of the bob,   is the density of the fluid, and • g is the gravitational acceleration: d b b b F gV gV   
  • 9. • The drag force results from the flow field surrounding the bob and particularly from the wake of the bob. • In flow analyses based on similarity principles, these influences are accounted for by empirical coefficient CL or CT in the drag law for: 2 2 Flow, Turbulent U D C F b T d   U D C F b L d   Flow, Laminar
  • 10. The volume flow rate through the rotameter is: Where m is the open area ratio, defined as: And D is the tube diameter at the height of the bob.
  • 12. where the parameter  is defined in terms of a constant K =Vb/D3 b characteristic of the shape of the bob: for turbulent flow: for laminar flow:
  • 13. With either laminar or turbulent flow through the rotameter, the flow rate is proportional to m. If the cross-sectional area of the tube is made to increase linearly with length, i.e., then since the cone angle  of the tube is small, and the flow rate is directly proportional to the height h of the bob. h
  • 14. Similarity Analysis. • The basic scaling parameter for flow is the Reynolds number, defined as: •where UIN is the velocity at the rotameter inlet, and the tube diameter D is represented by its value at the inlet, equal to the bob diameter Db. • Through the Reynolds number regimes of laminar or turbulent flow, and particularly important for the rotameter flow regimes with strong or weak viscosity dependence can be distinguished. •It has been found to be practical for rotameters to use an alternative characteristic number, the Ruppel number, defined as:
  • 15. where mb = bD3 b is the mass of the bob. By combining Equations, the mass flow through the rotameter can be written as: The relationship between the Ruppel number and the Reynolds number: The advantage of the Ruppel number is its independence of the flow rate. Since the Ruppel number contains only fluid properties and the mass and the density of the bob, it is a constant for a particular instrument.
  • 16. Design Charts for Laminar Rotameters
  • 17. Design Charts for Turbulent Rotameters
  • 19. (1) End fitting — flange shown; (2) flowmeter body; (3) rotation pickup — magnetic, reluctancetype shown; (4) permanent magnet; (5) pickup cold wound on pole piece; (6) rotor blade; (7) rotor hub; (8) Rotor shaft bearing — journal type shown; (9) rotor shaft; (10) diffuser support and flow straightener; (11) diffuser; (12) flow conditioning plate (dotted) — optional with some meters.
  • 22. Theory • There are two approaches described in the current literature for analyzing axial turbine performance. • The first approach describes the fluid driving torque in terms of momentum exchange, while the second describes it in terms of aerodynamic lift via airfoil theory. • The former approach has the advantage that it readily produces analytical results describing basic operation, some of which have not appeared via airfoil analysis. • The latter approach has the advantage that it allows more complete descriptions using fewer approximations. • However, it is mathematically intensive and leads rapidly into computer-generated solutions.
  • 23. Eliminating the time dimension from the left-hand-side quantity reduces it to the number of rotor rotations per unit fluid volume, which is essentially the flowmeter K factor specified by most manufacturers.
  • 24. • In the ideal situation, the meter response is perfectly linear and determined only by geometry. • In some flowmeter designs, the rotor blades are helically twisted to improve efficiency. • This is especially true of blades with large radius ratios, (R/a). • If the flow velocity profile is assumed to be flat, then the blade angle in this case can be described by tan  = Constant X r. • This is sometimes called the “ideal” helical blade. • In practice, there are instead a number of rotor retarding torques of varying relative magnitudes. • Under steady flow, the rotor assumes a speed that satisfies the following equilibrium:
  • 25. • The difference between the actual rotor speed, r, and the ideal rotor speed, ri , is the rotor slip velocity due to the combined effect of all the rotor retarding torques , and as a result of which the fluid velocity vector is deflected through an exit or swirl angle, . • Denoting the radius variable by r, and equating the total rate of change of angular momentum of the fluid passing through the rotor to the retarding torque, one obtains: NT is the total retarding torque
  • 26. Industrial Correlations for Frictional Losses
  • 27. Electromagnetic Flowmeters • Magnetic flowmeters have been widely used in industry for many years. • Unlike many other types of flowmeters, they offer true noninvasive measurements. • They are easy to install and use to the extent that existing pipes in a process can be turned into meters simply by adding external electrodes and suitable magnets. • They can measure reverse flows and are insensitive to viscosity, density, and flow disturbances. • Electromagnetic flowmeters can rapidly respond to flow changes and they are linear devices for a wide range of measurements. • As in the case of many electric devices, the underlying principle of the electromagnetic flowmeter is Faraday’s law of electromagnetic induction. • The induced voltages in an electromagnetic flowmeter are linearly proportional to the mean velocity of liquids or to the volumetric flow rates.
  • 28. • As is the case in many applications, if the pipe walls are made from nonconducting elements, then the induced voltage is independent of the properties of the fluid. • The accuracy of these meters can be as low as 0.25% and, in most applications, an accuracy of 1% is used. • At worst, 5% accuracy is obtained in some difficult applications where impurities of liquids and the contact resistances of the electrodes are inferior as in the case of low-purity sodium liquid solutions. • Faraday’s Law of Induction • This law states that if a conductor of length l (m) is moving with a velocity v (m/s–1 ), perpendicular to a magnetic field of flux density B (Tesla), then the induced voltage e across the ends of conductor can be expressed by: Blv e 
  • 29. The velocity of the conductor is proportional to the mean flow velocity of the liquid. Hence, the induced voltage becomes: BDv e 
  • 32. Ultrasonic Flowmeters • There are various types of ultrasonic flowmeters in use for discharge measurement: • (1) Transit time: This is today’s state-of-the-art technology and most widely used type. • This type of ultrasonic flowmeter makes use of the difference in the time for a sonic pulse to travel a fixed distance. • First against the flow and then in the direction of flow. • Transmit time flowmeters are sensitive to suspended solids or air bubbles in the fluid. • (2) Doppler: This type is more popular and less expensive, but is not considered as accurate as the transit time flowmeter. • It makes use of the Doppler frequency shift caused by sound reflected or scattered from suspensions in the flow path and is therefore more complementary than competitive to transit time flowmeters.
  • 33. Principle of transit time flowmeters.
  • 34. Transit Time Flowmeter • Principle of Operation • The acoustic method of discharge measurement is based on the fact that the propagation velocity of an acoustic wave and the flow velocity are summed vectorially. • This type of flowmeter measures the difference in transit times between two ultrasonic pulses transmitted upstream t21 and downstream t12 across the flow. • If there are no transverse flow components in the conduit, these two transmit times of acoustic pulses are given by:
  • 35. Since the transducers are generally used both as transmitters and receivers, the difference in travel time can be determined with the same pair of transducers. Thus, the mean axial velocity along the path is given by:
  • 36. Example • The following example shows the demands on the time measurement technique: • Assume a closed conduit with diameter D = 150 mm, angle = 60°, flow velocity = 1 m/s, and water temperature =20°C. • This results in transmit times of about 116 s and a time difference  t =t12 – t21 on the order of 78 ns. • To achieve an accuracy of 1% of the corresponding full-scale range, t has to be measured with a resolution of at least 100 ps (1X10–10 s). • Standard time measurement techniques are not able to meet such requirements so that special techniques must be applied. • Digital timers with the state-of-the –art Micro computers will make it possible to measure these time difference.
  • 38. Point Velocity Measurement • Pitot Probe Anemometry : Potential Flow Theory & Bernoulli’s Theory . • Thermal Anemometry : Newton’s Law of Cooling. • Laser Anemometry: Doppler Theory.