NEOGARD®N6   Building Envelope System Curt CarpenterOwner - C&G COATINGS Your NEOGARD®Representative
CONTENT ?WhoWe are…
Definitions & Considerations
Basic Components of NEOGARD® Systems
NEOGARD® Products
NEOGARD® SystemsWho we are…The Jones-Blair, Co. has been manufacturing protective coatings for over 80 years:
Liquid Coatings
Liquid Applied Membranes
Two Divisions
JB Industrial Coatings
Metal Protection
Oil Industry
NEOGARD®Construction Coatings
Waterproofing Systems
Roofing Systems
Flooring SystemsWho we are…NEOGARD® Products 		(Type of coatings)RIGID(NON-ELASTOMERIC)ELASTOMERICFLOORINGWATERPROOFINGEpoxyNovolacPolyurethanePolyureaUrethaneAcrylicSilicone
Who we are…NEOGARD®Product Lines
Waterproofing Systems(Elastomeric)
AutoGard for Vehicular Traffic
PedaGard for Pedestrian Traffic
Roofing Systems           (Elastomeric)
Direct Bond/ElastaGard over existing systems
SPF
Flooring Systems			(Rigid)NEOGARD®CREDENTIALS:World’s leading producer of Elastomeric Coating Membrane for construction
50-year history as the innovators in Polymeric Coating Technology, and 80 years in the Coating Industry
An international network of Licensed Applicators plus Performance Based Contractors
Bio-Based Roof Coating Membrane Systems Available (36% Bio Content)- Listed on USDA  website:  www.biopreferred.gov   International Standard ISO 9001:2000
   UL Class “A” Fire Rated
   Recognized by Factory Mutual
   LEED Friendly
   Miami Dade County Approved
   Member of U.S. Green Building Council
   CRRC
   ENERGY STAR® Rated	WaterproofingFor Vehicular &Pedestrian Traffic Parking Decks
 Balconies
 Exterior Walkways
 StadiumsFor Low Slope RoofApplications Over: Spray Polyurethane Foam
 EPDM/Single-Ply
 Modified Bitumens
 Built-Up Roofs
 Metal
 ConcreteRoof ProtectionWall ProtectionFor Commercial& Industrial Exterior WallApplications Over Concrete
 EIFS
 MasonryInterior Floor ProtectionFor Thin & ThickFilm Applications Industrial
 Commercial
 Food Processing
 Electronics (Electrostatic Dissipation) Aviation
 DecorativeROOFING
Sprayed Polyurethane Foam (SPF) Roof SystemNEOGARD® Permathane II™ Coating Membrane Louisiana Superdome,  New Orleans, LA
Elasta-GardDirect Bond, Fluid-AppliedRoof Coating Membrane
WATERPROOFING
NEOGARD®AUTO-GARD®Vehicular Traffic Bearing Coatings NY, NY Las VegasParking Deck
NEOGARD®PEDA-GARD®Pedestrian TrafficBearing Coatings University of KentuckyLexington, KY
WALL COATINGS
NEOGARD®PEDA-GARD®Pedestrian Traffic Bearing Coatings andNEOFLEX®Elastomeric Wall Coating Fountainbleau ResortMiami, FL
FLOORING
The President of theUnited Sates of Americahas a Support Fleet of Helicoptersin a protected hangarwhat protects the floor?
NEOGARD®SkyGard™Floor Coating SolutionsPatuxent River Naval Air StationPatuxent, MD
Roof ProtectionFor Low Slope RoofApplications Over: Spray Polyurethane Foam
 EPDM/Single-Ply
 Modified Bitumens
 Built-Up Roofs
 Metal
 ConcreteA division of the Jones-Blair CorporationSUSTAINABLE “GREEN”STRENGTH IN TODAY’S ROOFINGPOLYURETHANE FOAM  & DIRECT BOND ROOF SYSTEMS
Some of our clients:                         Caesar’s PalaceLOCAL:John Hopkins Hospital-   Avila UniversityRutgers University-  Kansas UniversityUnited States Government-Bonner Springs School DistrictO’Hare International Airport-Miller Distribution CompanyEDS Travelers	- York Label CompanyTexas A&M University (7 million sq.ft. foam)       -   Casey’s General StoresMurray Field			                   -   American Airlines Maint BldgUniversity of Kentucky			   -   Clark Enterprises, KC Fairfax areaUniversity of West Virginia		   -   Have test patches on Quick TripNew Orleans Superdome		       warehouse facility in Belton, MOGetty Museum				Tandy Corporation		Marriott Hotels 				Bellagio	U.S. Department of Navy
Our message is to educate you about......Alternate roofing systems that emphasize: Fiscal Responsibility Environmental Stewardship    with: Roofing products that have been tested and workLicensed Performance Based NEOGARD® contractors that you can trust10, 15 & 20 year warranties
The Roofing Systems
24Polyurethane Foam Roofing SystemBASF PolyurethaneFoam Enterprises LLCElastomeric, reflective protective coatingSpray-applied polyurethane foamExisting BUR substrateOriginal roof deck
Polyurethane Foam can be applied directly over:BUR
  Modified Bitumen
  EPDM
  Single-Ply
  Metal
  ConcreteRoof Deck
Spray Polyurethane Foam (SPF) roofing consists of an application of specifically designed foam covered with an elastomeric coating to protect the foam from ultraviolet rays.
Specialized equipment mixes two liquid components at the spray gun that applies the SPF to a prepared substrate.  The mixed liquid expands many times its original volume in a matter of seconds, forming a rigid foam plastic that chemically bonds to the surface to which it is sprayed.
SPF has a closed cell structure that makes it water resistant.  It must, however, be protected by elastomeric coatings to prevent ultra-violet-induced surface degradation.
Since SPF adds little weight (60# per 100 sq.ft.) to existing roof coverings and can build slope to fill in low areas, these systems are used frequently as a retrofit roofing system.SPF Chemistry Fundamentals A-Side:  MDI  - IsocyanateB-Side:  Proprietary Polyol Resin Blend polyols , catalysts, fire retardants, blowing agentsA+B = polyurethane foam
Base CoatSingle component moisture-cured, aromatic, fire retardant, polyurethane coating.  2gal/100 sq.ft.; 26 dry mils; 10-yr warranty
  3 gal/100 sq.ft.; 39 dry mils; 20-yr warrantyUrethaneTensile Strength – 1,000 psiElongation – 375%Water Absorption - <3%High Impact ResistanceChemical ResistantAcrylicsTensile Strength – 300 psiElongation – 300%Water Absorption – 20%Low Impact ResistanceSuspect to Chemical Attack
“Cool Roof” rated TopcoatSingle component, moisture-cured, aromatic, polyurethane coating designed as a weather protective coating.  UV Stable  1 gal/100 sq.ft.; 13 dry mils; 10-yr warranty
  1.5 gal/100 sq.ft.; 18 dry mils; 20-yr warrantyUrethaneTensile Strength – 1,500 psiElongation – 360%Water Absorption - <3%High Impact ResistanceChemical ResistantAcrylicsTensile Strength – 300 psiElongation – 300%Water Absorption – 20%Low Impact ResistanceSuspect to Chemical Attack
Benefits of Polyurethane Foam Roof Systems........
CPI Corporation – Great Bend, KS100,000 sq.ft. metal roofScrewsPolyurethane FoamOver Metal RoofSeams2ndPass of Foam1st Pass of FoamMetal Roof
NO SEAMS OR LOOSE SCREWS!!2”, 3lb/cu.ft. Polyurethane Foam
  2 Base Coats – 37 Mils
  2 Topcoats – 18 MilsTotal 55 Mils Coating w/granulesPolyurethane Foamover metal roof
Rubber Roof with River Rock
Rock Removed and Rubber Secured with I-90 Wind Uplift Rated Fasteners
Foam Applied Over RubberSelf-Flashing
Base Coat Applied
Permathane II FR Polyurethane Foam RoofEverything is SEALEDCool Roof, LEED Qualified Topcoat
Applying Polyurethane Foam over Modified Bitumen Roof with ChatModified Bitumen Roof with Chat
Chat Removed
Polyurethane Foam Base
Granules
  1 ½” Polyurethane Foam
  2 gallons/100 sq.ft. Base Coat – 26 dry mils
  1 gallon/100 sq.ft. Topcoat – 13 dry mils
  GranulesAn Option To Tearing Off A Polyurethane Roof That Has Not Been Maintained………………..
Foam Roof not maintained since 1984
Scarifying the coating and ¼” of the foam base
Hard to reach areas will be hand grinded
Before10-year Permathane II FR WarrantyExtended warranty for 10-years
If it’s good enough for the New Orleans Superdome………………..Polyurethane Foam Base with NEOGARD®Urethane CoatingRe-roofed after Hurricane Katrina damage in 2006
A division of the Jones-Blair CorporationELASTA-GARDDIRECT-BOND, FLUID-APPLIED ROOF SYSTEMSCOMPATIBLE OVER:  -  BUILT-UP ROOFING (BUR)			-  MODIFIED BITUMEN (MB)			-  SINGLE-PLY			-  EPDM			-  METAL			-  CONCRETE
45,000 sq.ft. metal roofRoof before applying coating membrane
Penetrations & Vertical Seams Sealed with Polyurethane FoamPolyurethane FoamPolyurethane foam on vertical seams
Caulk & Apply Basecoat to ScrewsTape & coating on screw holesCaulk & Coating on screws
Horizontal Seams Taped & Base Coated
All Seams & Screws Base Coated Prior to Applying the TopcoatRoof is totally waterproofed prior to application of white topcoat
Finish Pics
Acrylithane MRC Topcoat over Metal      (any color can be matched)
ELASTA-GARD BUR/MB Over modified bitumenLeak Problem Areas
Seams detailedDrains detailedProtrusions detailed
Urethane Base Coat7419 HB3 gallons/100 sq.ft.39 dry milsTensile Strength – 350 psiElongation – 500%
Topcoat being appliedTopcoat can either be sprayed or rolled.  Rolled during windy conditionsNotice how parapet walls are sealed
Urethane Topcoat70613 – white1.75 gallons/100 sq.ft.21 dry milsTensile Strength – 1,500 psiElongation – 360%Total system coating thickness averages 60 dry mils – 15 year warrantyNO SEAMS!!!
Edison Elementary Roof Coating ProjectMangum, OKProject completed by:  Washington Companies Inc.                                                                     Chuck Carpenter - OwnerChuck,“Thanks for the pictures.  Any other pictures that you have would be great as I will use them to put in the newspaper and also present them to our school board members.  I am very impressed with the job you guys did and the professionalism of the workers.  You have my full recommendation for any job you are seeking”.Micky LivelySuperintendent, Mangum Schools
EXISTING ROOFGranulated Modified Bitumen – 40,000 sq.ft.EXISTING ROOFGranulated Modified Bitumen – 40,000 sq.ft.
Checking depth of alligator  cracks in ponding areasGranulated Modified Bitumen
SURFACE PREPARATIONHigh Pressure Power Wash with Bio-degradable CleanerNEOGARD8500 Bio-Degradable Cleaner
Bad areas & protrusions detailed with Polyurethane Foam“Reddish” color is 7780/7781 Primer1/3 gal/100 sq.ft.
7419 HB Urethane Base Coat350 psi tensile strength500% Elongation1.5 gal/100 sq.ft. – 18 dry mils
After Base Coat is Applied to Entire Roof2nd Coat of 7419 HB is Applied to the Seams
70613 Urethane Topcoat2,500 psi tensile strength450% Elongation1.5 gal/100 sq.ft. – 18 dry mils
#11 Roofing Granules Applied Over Wet TopcoatTotal System Elastomeric Coating Thickness to Average 36 Dry Mils for this Project
ELASTA-GARD SPSingle-PlyRubber Roof
Encapsulate parapet wall with polyurethane foamSeam Tape
SEAM DETAIL
TopcoatBase Coat
Urethane Topcoat70613 – white1 gallon/100 sq.ft.12 dry milsTensile Strength – 1,500 psiElongation – 360%Total system coating thickness averages 38 dry mils
LEED Qualified, Cool Roof Rated TopcoatTest PatchFree application to qualified facilityBase Coat Primer
FISCAL RESPONSIBILITY
ROOF SYSTEM COST COMPARISONPolyurethane FoamvsModified Bitumen -            10,000 sq.ft. examplePOLYURETHANE FOAM – ALPHA                                              4-PLY MODIFIED BITUMENPOLYURETHANE FOAM                                                          4-PLY MODIFIED BITUMEN
ROOF SYSTEM COST COMPARISONDirect Bond vs. Modified Bitumen10,000 sq.ft. roof used for example:4-PLY MODIFIED BITUMENDIRECT BOND ROOF SYSTEM*** No tear-off in 95% of retrofit applications ***Performance Requirements for Cured Film:                                            Base Coat (39 dry mils)     Topcoat (21 dry mils)  Tensile Strength:                         1,000 psi                         1,500 psi
  Elongation:                                     375%                            360%               Total Film Thickness Averages 60 Dry Mils*** Tear-Off required at initial re-roofing and each warrantyextension period ***
ROOF SYSTEM COST COMPARISONDirect Bond vs. EPDM (Rubber)10,000 sq.ft. roof used for example:EPDM (Rubber)DIRECT BOND ROOF SYSTEM*** No tear-off in 95% of retrofit applications ***Performance Requirements for Cured Film:                                            Base Coat (26 dry mils)     Topcoat (12 dry mils)  Tensile Strength:                         1,000 psi                         1,500 psi
  Elongation:                                     375%                            360%             Total Film Thickness Averages 38 Dry Mils*** Tear-Off required at initial re-roofing and each warrantyextension period ***
TAX ADVANTAGESFOR DIRECT BOND ROOF SYSTEMSAccording to Sec. 1.162-4 Repairs of IRS Tax Code:Roof maintenance systems are fully tax deductable as an operating expense.  One of the key advantages of a restoration system over a new roof system is in how it is classified by the IRS.  Restoration is classified as a maintenance, and in most cases it can be expensed in the accounting period it is incurred.  On the other hand a new roof system is a capital asset that must be amortized over a 39 year life.
ENVIRONMENTAL STEWARDSHIP
A division of the Jones-Blair CorporationWhy are Cool Roofs Cool?....................Simple Science – dark materials absorb more heat than light materials
   Most “Traditional” dark-colored roofs absorb 70% or more of the        solar energy striking them – resulting in peak roof temperatures of 150*        to   190* F.   By comparison – a white, reflective cool roof will be 50* to 60*F cooler        on hot days.   The resulting reduction of heat transfer into the air-conditioned spaces can       decrease cooling costs by 20% or more.
ENERGY STAR® ReflectivitySolar Reflectance of a Roof is defined as the percentage of solar energy Reflected by the roof’s surface.ENERGY STAR®  Reflectance Requirements:
65% Initial
50% Aged (+3 years – actual)________________________________________NEOGARD®White Roof Coating Membranes are ENERGY STAR® compliant. Acrylic
Initial:  74% Aged: 68%
Silicone
Initial: 75%  Aged: 75%
Polyurethane (7443)

Neogard Product Presentation N6

Editor's Notes

  • #117 View of ICRI CSP coupons. These are the profiles we strive for prior to applying deck coatings