PROFIBUS Basics
Date 09/06/00, Page 1
PROFIBUS Basics
s
Active Stations
Passive Stations (Field Devices)
PLC
PC
PROFIBUS
PROFIBUS Basics
Date 09/06/00, Page 2
PROFIBUS Basics
s
All PROFIBUS services
High Speed Data Exchange
Peer to Peer
Hazardous Area
can be used together in one network
Therefore Communication is Transparent for
the User
Same Cable and Components for High Speed
Data Exchange and Peer to Peer
PROFIBUS Basics
Date 09/06/00, Page 3
PROFIBUS Basics
s
High-Speed Data Exchange Features
Same priority for all field devices
Communication is permanent & cyclic
Amount of data specified during configuration
Only one master can write to outputs (safety
aspect)
Acyclic communication to field devices possible by
using extended functions (DP Extended/DPV1)
Alarm acknowledgment
Up to 244 bytes input AND 244 bytes output data
per field device
Fastest fieldbus system (up to 12Mbaud)
PROFIBUS Basics
Date 09/06/00, Page 4
PROFIBUS Basics
s
System Configuration
PLC
PROFIBUS
GSD GSD GSD GSD GSD GSD
Plug & Play With Electronic Device Data Sheets
PROFIBUS
Configuration Tool
Electronic Device Data Sheets (GSD, GSE, GSF, GSG, GSI, GSP, GSS Files)
PROFIBUS Basics
Date 09/06/00, Page 5
PROFIBUS Basics
s
High-Speed Data Exchange - Startup Sequence
Power ON/
Reset
Power ON/Reset of Master or Slave
Parameterization
Download of Parameters into the Field
Device (selected during Configuration
by the User)
I/O Configuration
Download of I/O Configuration into the
Field Device (selected during
Configuration by the User)
Data Exchange
Cyclic Data Exchange (I/O Data)
and Field Device reports Diagnostics
PROFIBUS Basics
Date 09/06/00, Page 6
PROFIBUS Basics
s
High-Speed Data Exchange - Parameterization
Master Slave
Features Implemented in Device
Described in GSD File
Processed by Configuration Tool
Selected at Configuration
Examples:
Enable Channel Diagnostic
Operation Range for Analog Channels
(e.g. ±10V or 0..10V)
Fail Safe Behavior (e.g. Hold Last
Value)
Parameter Download (up to 244 bytes)
= Parameterization Data = Confirmation (Data Received)
PROFIBUS Basics
Date 09/06/00, Page 7
PROFIBUS Basics
s
Parameterization (continued)
Parameter selection with Configuration Tool
jsdfehrgihw[orijth]ewj]ypokjeky
gadfgsadfhsfghjjsffghsfgh
fdhsdldajhtviertivetvert
34524
575687356nj8467knggnhngjt
rby5yik57859mnnbvt456hn,
g76nkbvijyuftisdt0iewryt9eiuoriy
rywkrowrgowrtohworthorthwrth
rthwrthrwthtryjtyjyuky
tyjy7u79jtyu568566ut
rtjhyuiuikujkhyjiyuiyuii
thjyukiuio7ujtyujytuoiuky
tyjyukuikyukuiluiliuioliuiluiil
6buhyijtiu8o67m8m747567n8
567n75567nm78m78,om87o,
56nu78m,,9o,0p.90.p;0;.;’-;/
jsdfehrgihw[orijth]ewj]ypokjeky
gadfgsadfhsfghjjsffghsfgh
fdhsdldajhtviertivetvert
34524
575687356nj8467knggnhngjt
rby5yik57859mnnbvt456hn,
g76nkbvijyuftisdt0iewryt9eiuoriy
rywkrowrgowrtohworthorthwrth
rthwrthrwthtryjtyjyuky
tyjy7u79jtyu568566ut
rtjhyuiuikujkhyjiyuiyuii
thjyukiuio7ujtyujytuoiuky
tyjyukuikyukuiluiliuioliuiluiil
6buhyijtiu8o67m8m747567n8
567n75567nm78m78,om87o,
56nu78m,,9o,0p.90.p;0;.;’-;/
Fewer DIP Switches - NO Handheld - NO Extensive Additional Documentation
User defines every Function in ONE Tool.
PROFIBUS Basics
Date 09/06/00, Page 8
PROFIBUS Basics
s
High-Speed Data Exchange - Configuration
Master
Configuration Download (up to 244 bytes)
= Configuration Data = Confirmation (Data Received)
Possible I/O Selections described in GSD File
Processed by Configuration Tool
Selected at Configuration
Examples
8DI (1 Byte), 8DO (1 Byte)
2AI (2 Words), 2AO (2 Words)
RS232 Interface, Counter Module
Slave
PROFIBUS Basics
Date 09/06/00, Page 9
PROFIBUS Basics
s
Configuration Tool (continued)
I/O selection with Configuration Tool
PROFIBUS Basics
Date 09/06/00, Page 10
PROFIBUS Basics
s
PROFIBUS Demo
Parameter &
I/O
Selection
Parameter &
I/O
Selection
PROFIBUS Basics
Date 09/06/00, Page 11
PROFIBUS Basics
s
High-Speed I/O - Data Exchange & Diagnostics
Master Slave
= Output Data = Input Data
Master Slave
Slave indicates diagnostics to report
Data Exchange (up to 244 bytes)
= Diagnostic Indicator
PROFIBUS Basics
Date 09/06/00, Page 12
PROFIBUS Basics
s
Data Exchange & Diagnostics (continued)
Master Slave
= Diagnostic Request = Diagnostic Response
Master Slave
Data Exchange (up to 244 bytes)
Diagnostic Request and Response (up to 244 bytes)
PROFIBUS Basics
Date 09/06/00, Page 13
PROFIBUS Basics
s
Diagnostic Response (continued)
6 Bytes
Mandatory
Header Header Header
Device
Related
(Optional)
Identifier
Related
(Optional)
Channel
Related
(Optional)
Up to 244 Bytes
e.g. wrong
configuration
e.g. no load
power
e.g. module #4
has diagnostic
e.g. wire break or
short circuit
PROFIBUS Basics
Date 09/06/00, Page 14
PROFIBUS Basics
s
High-Speed Data Exchange - Fail Safe
What happens if my bus fails:
valve open, valve closed,
valve 1/2 open…???
Optional feature Fail Safe specifies behavior of
Outputs in case of Communication Loss
Optional feature Fail Safe specifies behavior of
Outputs in case of Communication Loss
PROFIBUS Basics
Date 09/06/00, Page 15
PROFIBUS Basics
s
Fail Safe (continued)
Optional Feature for Field Devices
Defined in Electronic Device Data Sheet
Manufacturer has the capability to allow the End
User to specify the action on loss of communication
Hold outputs at the last value received (e.g. valve 1/2 open)
Set outputs to a specified value (e.g. open or close valve
completely)
User defines action during Parameterization
PROFIBUS Basics
Date 09/06/00, Page 16
PROFIBUS Basics
s
Fail Safe (continued)
PROFIBUS Basics
Date 09/06/00, Page 17
PROFIBUS Basics
s
PROFIBUS Demo
Diagnostics &
Fail Safe
Diagnostics &
Fail Safe
PROFIBUS Basics
Date 09/06/00, Page 18
PROFIBUS Basics
s
High-Speed Data Exchange Timing
10 Stations With 2 Byte I/O (160 In/Output Signals)
Bus Cycle Time 0.8ms
PROFIBUS Basics
Date 09/06/00, Page 19
PROFIBUS Basics
s
High-Speed Data Exchange Timing
10 Stations With 128 byte I/O (10,240 In/ Output Signals)
Bus Cycle Time 2.0ms
PROFIBUS Basics
Date 09/06/00, Page 20
PROFIBUS Basics
s
High-Speed Data Exchange Timing
Typical Cycle Time - Each Station With 2 Byte I/O
0.3 0.5
2.1
8.8
2.0
20.5
1.5
0.8
3.3
2.00.9
6.1
4.6
7.7
14.1
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
20.0
1 5 10 20 30 [Number of
Slaves]
[ms]
12MBaud
1.5MBaud
500kBaud
PROFIBUS Basics
Date 09/06/00, Page 21
PROFIBUS Basics
s
PROFIBUS Summary
Extensive Parameterization Features
Extensive Diagnostic Features
Fail-Safe Behavior
Deterministic
Fast (Up to 12 MBaud)
Safe and Reliable
Easy Configuration
Capabilities for Complete Plant Solution from
Cell to Bit Level

More Related Content

PDF
Industrial communication protocol
ASWATHYSURESH18
 
PDF
Introduction to PROFIBUS and PROFINET - andy verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
PPTX
Profibus vs profinet
Rahul Shekhawat
 
PPTX
Profibus
prashob7
 
PDF
Introduction to PROFINET - Derek Lane of Wago
PROFIBUS and PROFINET InternationaI - PI UK
 
PPTX
Industrial communication
Mahmoud Hussein
 
PPTX
BASICS OF FIELDBUS
Shivam Singh
 
PPT
Foundation fieldbus
sharadonlinemails
 
Industrial communication protocol
ASWATHYSURESH18
 
Introduction to PROFIBUS and PROFINET - andy verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
Profibus vs profinet
Rahul Shekhawat
 
Profibus
prashob7
 
Introduction to PROFINET - Derek Lane of Wago
PROFIBUS and PROFINET InternationaI - PI UK
 
Industrial communication
Mahmoud Hussein
 
BASICS OF FIELDBUS
Shivam Singh
 
Foundation fieldbus
sharadonlinemails
 

What's hot (20)

PPTX
Communication Protocols
PranavAutomation
 
PPT
SIEMENS S7-300c.ppt
Sidharth Mohapatra
 
PPTX
Hart - Highway Addressable Remote Transducer Protocol
Vasanthan Ravichandran
 
PPT
Profibus
plc_course
 
PPT
PLC and Industrial Automation - Technology Overview
Nereus Fernandes
 
PPTX
Basic of MODBUS Communication/Protocol
Shivam Singh
 
PPTX
Modbus introduction
Prem Sanil
 
PDF
Modbus TCP/IP implementation in Siemens S7-300 PLC
ITER-India, IPR
 
PDF
PLC Programming Languages
LIJU. G. CHACKO
 
PDF
Programmable logic controller - Siemens S7-1200
Ahmed Elsayed
 
PPTX
Profinet Training
ICP DAS USA, Inc.
 
PPTX
PLC Architecture
PranavAutomation
 
PPTX
Modbus protocol
sharath alugandula
 
PPTX
Hart communication protocol
Nishtha Shreya
 
PPTX
Modbus
Manoj89p
 
PDF
Practical steps to a successful PROFIBUS project - Richard Needham and Xiu Ji
PROFIBUS and PROFINET InternationaI - PI UK
 
PPTX
Introduction to foundation fieldbus
Mohamed A Hakim
 
PDF
Basic Electronics Interview Questions.pdf
Engineering Funda
 
PPTX
Hart Protocol Introduction
ICP DAS USA, Inc.
 
PDF
PLC - Programmable Logic Controller
Mahesh Vadhavaniya profmjv
 
Communication Protocols
PranavAutomation
 
SIEMENS S7-300c.ppt
Sidharth Mohapatra
 
Hart - Highway Addressable Remote Transducer Protocol
Vasanthan Ravichandran
 
Profibus
plc_course
 
PLC and Industrial Automation - Technology Overview
Nereus Fernandes
 
Basic of MODBUS Communication/Protocol
Shivam Singh
 
Modbus introduction
Prem Sanil
 
Modbus TCP/IP implementation in Siemens S7-300 PLC
ITER-India, IPR
 
PLC Programming Languages
LIJU. G. CHACKO
 
Programmable logic controller - Siemens S7-1200
Ahmed Elsayed
 
Profinet Training
ICP DAS USA, Inc.
 
PLC Architecture
PranavAutomation
 
Modbus protocol
sharath alugandula
 
Hart communication protocol
Nishtha Shreya
 
Modbus
Manoj89p
 
Practical steps to a successful PROFIBUS project - Richard Needham and Xiu Ji
PROFIBUS and PROFINET InternationaI - PI UK
 
Introduction to foundation fieldbus
Mohamed A Hakim
 
Basic Electronics Interview Questions.pdf
Engineering Funda
 
Hart Protocol Introduction
ICP DAS USA, Inc.
 
PLC - Programmable Logic Controller
Mahesh Vadhavaniya profmjv
 
Ad

Similar to Industrial Networking - Profibus (20)

PDF
Basics_of_Profibus_Profibus_in_Practice_1707437568.pdf
FarukPatel9
 
PDF
PI Technologies for Process Automation
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
Introduction to PROFIBUS for process automation Andy Verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
profibus theory solution
Md. Mashiur Rahman
 
PDF
Best Practice in PROFIBUS Diagnostics
Bernd Kremer
 
PDF
Introduction to profibus for process automation andy verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
Introduction to PROFIBUS for process automation Andy Verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
Webinar on PROFIBUS Network Maintenance
Sadatulla Zishan
 
PPT
Getting Started With Pb T4 Comment Lan
frank8040
 
PDF
PROFIsafe and Trends - Pete Brown - Siemens
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
Profibus DP Telegrams COURSE How to .pdf
MarceloMaccari1
 
PDF
Profibus PA device commissioning and maintenance - Andy Verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
PPTX
1. Profibus - Part-1 Detail & Communication
syedtalhaees
 
PDF
PROFIBUS .. xxxxxxxxxxxxccccccccccccc.pdf
FelipeDiaz460851
 
PDF
3. The basics of PROFIBUS and PROFINET - Mark Freeman
PROFIBUS and PROFINET InternationaI - PI UK
 
PPT
Fc300 profibus training
Marcos Romanholo
 
PDF
Unit 4 ppt-idc
hiya123jes
 
PDF
C11 PROFIsafe, considerations for functional safety and security - Pete Bro...
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
PROFIsafe and Trends - Pete Brown
PROFIBUS and PROFINET InternationaI - PI UK
 
PDF
A Holistic approach to PROFIBUS health monitoring - Dale Fittes
PROFIBUS and PROFINET InternationaI - PI UK
 
Basics_of_Profibus_Profibus_in_Practice_1707437568.pdf
FarukPatel9
 
PI Technologies for Process Automation
PROFIBUS and PROFINET InternationaI - PI UK
 
Introduction to PROFIBUS for process automation Andy Verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
profibus theory solution
Md. Mashiur Rahman
 
Best Practice in PROFIBUS Diagnostics
Bernd Kremer
 
Introduction to profibus for process automation andy verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
Introduction to PROFIBUS for process automation Andy Verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
Webinar on PROFIBUS Network Maintenance
Sadatulla Zishan
 
Getting Started With Pb T4 Comment Lan
frank8040
 
PROFIsafe and Trends - Pete Brown - Siemens
PROFIBUS and PROFINET InternationaI - PI UK
 
Profibus DP Telegrams COURSE How to .pdf
MarceloMaccari1
 
Profibus PA device commissioning and maintenance - Andy Verwer
PROFIBUS and PROFINET InternationaI - PI UK
 
1. Profibus - Part-1 Detail & Communication
syedtalhaees
 
PROFIBUS .. xxxxxxxxxxxxccccccccccccc.pdf
FelipeDiaz460851
 
3. The basics of PROFIBUS and PROFINET - Mark Freeman
PROFIBUS and PROFINET InternationaI - PI UK
 
Fc300 profibus training
Marcos Romanholo
 
Unit 4 ppt-idc
hiya123jes
 
C11 PROFIsafe, considerations for functional safety and security - Pete Bro...
PROFIBUS and PROFINET InternationaI - PI UK
 
PROFIsafe and Trends - Pete Brown
PROFIBUS and PROFINET InternationaI - PI UK
 
A Holistic approach to PROFIBUS health monitoring - Dale Fittes
PROFIBUS and PROFINET InternationaI - PI UK
 
Ad

Recently uploaded (20)

PPTX
New ThousandEyes Product Innovations: Cisco Live June 2025
ThousandEyes
 
PDF
The Evolution of KM Roles (Presented at Knowledge Summit Dublin 2025)
Enterprise Knowledge
 
PDF
Tea4chat - another LLM Project by Kerem Atam
a0m0rajab1
 
PDF
A Day in the Life of Location Data - Turning Where into How.pdf
Precisely
 
PPTX
cloud computing vai.pptx for the project
vaibhavdobariyal79
 
PPTX
Applied-Statistics-Mastering-Data-Driven-Decisions.pptx
parmaryashparmaryash
 
PDF
Accelerating Oracle Database 23ai Troubleshooting with Oracle AHF Fleet Insig...
Sandesh Rao
 
PDF
AI-Cloud-Business-Management-Platforms-The-Key-to-Efficiency-Growth.pdf
Artjoker Software Development Company
 
PPTX
AI and Robotics for Human Well-being.pptx
JAYMIN SUTHAR
 
PDF
Research-Fundamentals-and-Topic-Development.pdf
ayesha butalia
 
PDF
AI Unleashed - Shaping the Future -Starting Today - AIOUG Yatra 2025 - For Co...
Sandesh Rao
 
PDF
NewMind AI Weekly Chronicles - July'25 - Week IV
NewMind AI
 
PDF
How Open Source Changed My Career by abdelrahman ismail
a0m0rajab1
 
PDF
Trying to figure out MCP by actually building an app from scratch with open s...
Julien SIMON
 
PPTX
OA presentation.pptx OA presentation.pptx
pateldhruv002338
 
PDF
Software Development Methodologies in 2025
KodekX
 
PDF
Get More from Fiori Automation - What’s New, What Works, and What’s Next.pdf
Precisely
 
PDF
How-Cloud-Computing-Impacts-Businesses-in-2025-and-Beyond.pdf
Artjoker Software Development Company
 
PDF
Presentation about Hardware and Software in Computer
snehamodhawadiya
 
PDF
Using Anchore and DefectDojo to Stand Up Your DevSecOps Function
Anchore
 
New ThousandEyes Product Innovations: Cisco Live June 2025
ThousandEyes
 
The Evolution of KM Roles (Presented at Knowledge Summit Dublin 2025)
Enterprise Knowledge
 
Tea4chat - another LLM Project by Kerem Atam
a0m0rajab1
 
A Day in the Life of Location Data - Turning Where into How.pdf
Precisely
 
cloud computing vai.pptx for the project
vaibhavdobariyal79
 
Applied-Statistics-Mastering-Data-Driven-Decisions.pptx
parmaryashparmaryash
 
Accelerating Oracle Database 23ai Troubleshooting with Oracle AHF Fleet Insig...
Sandesh Rao
 
AI-Cloud-Business-Management-Platforms-The-Key-to-Efficiency-Growth.pdf
Artjoker Software Development Company
 
AI and Robotics for Human Well-being.pptx
JAYMIN SUTHAR
 
Research-Fundamentals-and-Topic-Development.pdf
ayesha butalia
 
AI Unleashed - Shaping the Future -Starting Today - AIOUG Yatra 2025 - For Co...
Sandesh Rao
 
NewMind AI Weekly Chronicles - July'25 - Week IV
NewMind AI
 
How Open Source Changed My Career by abdelrahman ismail
a0m0rajab1
 
Trying to figure out MCP by actually building an app from scratch with open s...
Julien SIMON
 
OA presentation.pptx OA presentation.pptx
pateldhruv002338
 
Software Development Methodologies in 2025
KodekX
 
Get More from Fiori Automation - What’s New, What Works, and What’s Next.pdf
Precisely
 
How-Cloud-Computing-Impacts-Businesses-in-2025-and-Beyond.pdf
Artjoker Software Development Company
 
Presentation about Hardware and Software in Computer
snehamodhawadiya
 
Using Anchore and DefectDojo to Stand Up Your DevSecOps Function
Anchore
 

Industrial Networking - Profibus

  • 1. PROFIBUS Basics Date 09/06/00, Page 1 PROFIBUS Basics s Active Stations Passive Stations (Field Devices) PLC PC PROFIBUS
  • 2. PROFIBUS Basics Date 09/06/00, Page 2 PROFIBUS Basics s All PROFIBUS services High Speed Data Exchange Peer to Peer Hazardous Area can be used together in one network Therefore Communication is Transparent for the User Same Cable and Components for High Speed Data Exchange and Peer to Peer
  • 3. PROFIBUS Basics Date 09/06/00, Page 3 PROFIBUS Basics s High-Speed Data Exchange Features Same priority for all field devices Communication is permanent & cyclic Amount of data specified during configuration Only one master can write to outputs (safety aspect) Acyclic communication to field devices possible by using extended functions (DP Extended/DPV1) Alarm acknowledgment Up to 244 bytes input AND 244 bytes output data per field device Fastest fieldbus system (up to 12Mbaud)
  • 4. PROFIBUS Basics Date 09/06/00, Page 4 PROFIBUS Basics s System Configuration PLC PROFIBUS GSD GSD GSD GSD GSD GSD Plug & Play With Electronic Device Data Sheets PROFIBUS Configuration Tool Electronic Device Data Sheets (GSD, GSE, GSF, GSG, GSI, GSP, GSS Files)
  • 5. PROFIBUS Basics Date 09/06/00, Page 5 PROFIBUS Basics s High-Speed Data Exchange - Startup Sequence Power ON/ Reset Power ON/Reset of Master or Slave Parameterization Download of Parameters into the Field Device (selected during Configuration by the User) I/O Configuration Download of I/O Configuration into the Field Device (selected during Configuration by the User) Data Exchange Cyclic Data Exchange (I/O Data) and Field Device reports Diagnostics
  • 6. PROFIBUS Basics Date 09/06/00, Page 6 PROFIBUS Basics s High-Speed Data Exchange - Parameterization Master Slave Features Implemented in Device Described in GSD File Processed by Configuration Tool Selected at Configuration Examples: Enable Channel Diagnostic Operation Range for Analog Channels (e.g. ±10V or 0..10V) Fail Safe Behavior (e.g. Hold Last Value) Parameter Download (up to 244 bytes) = Parameterization Data = Confirmation (Data Received)
  • 7. PROFIBUS Basics Date 09/06/00, Page 7 PROFIBUS Basics s Parameterization (continued) Parameter selection with Configuration Tool jsdfehrgihw[orijth]ewj]ypokjeky gadfgsadfhsfghjjsffghsfgh fdhsdldajhtviertivetvert 34524 575687356nj8467knggnhngjt rby5yik57859mnnbvt456hn, g76nkbvijyuftisdt0iewryt9eiuoriy rywkrowrgowrtohworthorthwrth rthwrthrwthtryjtyjyuky tyjy7u79jtyu568566ut rtjhyuiuikujkhyjiyuiyuii thjyukiuio7ujtyujytuoiuky tyjyukuikyukuiluiliuioliuiluiil 6buhyijtiu8o67m8m747567n8 567n75567nm78m78,om87o, 56nu78m,,9o,0p.90.p;0;.;’-;/ jsdfehrgihw[orijth]ewj]ypokjeky gadfgsadfhsfghjjsffghsfgh fdhsdldajhtviertivetvert 34524 575687356nj8467knggnhngjt rby5yik57859mnnbvt456hn, g76nkbvijyuftisdt0iewryt9eiuoriy rywkrowrgowrtohworthorthwrth rthwrthrwthtryjtyjyuky tyjy7u79jtyu568566ut rtjhyuiuikujkhyjiyuiyuii thjyukiuio7ujtyujytuoiuky tyjyukuikyukuiluiliuioliuiluiil 6buhyijtiu8o67m8m747567n8 567n75567nm78m78,om87o, 56nu78m,,9o,0p.90.p;0;.;’-;/ Fewer DIP Switches - NO Handheld - NO Extensive Additional Documentation User defines every Function in ONE Tool.
  • 8. PROFIBUS Basics Date 09/06/00, Page 8 PROFIBUS Basics s High-Speed Data Exchange - Configuration Master Configuration Download (up to 244 bytes) = Configuration Data = Confirmation (Data Received) Possible I/O Selections described in GSD File Processed by Configuration Tool Selected at Configuration Examples 8DI (1 Byte), 8DO (1 Byte) 2AI (2 Words), 2AO (2 Words) RS232 Interface, Counter Module Slave
  • 9. PROFIBUS Basics Date 09/06/00, Page 9 PROFIBUS Basics s Configuration Tool (continued) I/O selection with Configuration Tool
  • 10. PROFIBUS Basics Date 09/06/00, Page 10 PROFIBUS Basics s PROFIBUS Demo Parameter & I/O Selection Parameter & I/O Selection
  • 11. PROFIBUS Basics Date 09/06/00, Page 11 PROFIBUS Basics s High-Speed I/O - Data Exchange & Diagnostics Master Slave = Output Data = Input Data Master Slave Slave indicates diagnostics to report Data Exchange (up to 244 bytes) = Diagnostic Indicator
  • 12. PROFIBUS Basics Date 09/06/00, Page 12 PROFIBUS Basics s Data Exchange & Diagnostics (continued) Master Slave = Diagnostic Request = Diagnostic Response Master Slave Data Exchange (up to 244 bytes) Diagnostic Request and Response (up to 244 bytes)
  • 13. PROFIBUS Basics Date 09/06/00, Page 13 PROFIBUS Basics s Diagnostic Response (continued) 6 Bytes Mandatory Header Header Header Device Related (Optional) Identifier Related (Optional) Channel Related (Optional) Up to 244 Bytes e.g. wrong configuration e.g. no load power e.g. module #4 has diagnostic e.g. wire break or short circuit
  • 14. PROFIBUS Basics Date 09/06/00, Page 14 PROFIBUS Basics s High-Speed Data Exchange - Fail Safe What happens if my bus fails: valve open, valve closed, valve 1/2 open…??? Optional feature Fail Safe specifies behavior of Outputs in case of Communication Loss Optional feature Fail Safe specifies behavior of Outputs in case of Communication Loss
  • 15. PROFIBUS Basics Date 09/06/00, Page 15 PROFIBUS Basics s Fail Safe (continued) Optional Feature for Field Devices Defined in Electronic Device Data Sheet Manufacturer has the capability to allow the End User to specify the action on loss of communication Hold outputs at the last value received (e.g. valve 1/2 open) Set outputs to a specified value (e.g. open or close valve completely) User defines action during Parameterization
  • 16. PROFIBUS Basics Date 09/06/00, Page 16 PROFIBUS Basics s Fail Safe (continued)
  • 17. PROFIBUS Basics Date 09/06/00, Page 17 PROFIBUS Basics s PROFIBUS Demo Diagnostics & Fail Safe Diagnostics & Fail Safe
  • 18. PROFIBUS Basics Date 09/06/00, Page 18 PROFIBUS Basics s High-Speed Data Exchange Timing 10 Stations With 2 Byte I/O (160 In/Output Signals) Bus Cycle Time 0.8ms
  • 19. PROFIBUS Basics Date 09/06/00, Page 19 PROFIBUS Basics s High-Speed Data Exchange Timing 10 Stations With 128 byte I/O (10,240 In/ Output Signals) Bus Cycle Time 2.0ms
  • 20. PROFIBUS Basics Date 09/06/00, Page 20 PROFIBUS Basics s High-Speed Data Exchange Timing Typical Cycle Time - Each Station With 2 Byte I/O 0.3 0.5 2.1 8.8 2.0 20.5 1.5 0.8 3.3 2.00.9 6.1 4.6 7.7 14.1 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0 1 5 10 20 30 [Number of Slaves] [ms] 12MBaud 1.5MBaud 500kBaud
  • 21. PROFIBUS Basics Date 09/06/00, Page 21 PROFIBUS Basics s PROFIBUS Summary Extensive Parameterization Features Extensive Diagnostic Features Fail-Safe Behavior Deterministic Fast (Up to 12 MBaud) Safe and Reliable Easy Configuration Capabilities for Complete Plant Solution from Cell to Bit Level