This Z-Wave module is used to regulate temperature in heating and
cooling mode. The module can be controlled either through Z-wave
network or through the wall switch.
The module is designed to be mounted inside a “flush mounting box”
and is hidden behind a traditional wall switch. Module measures power
consumption of connected device. It is designed to act as repeater in
order to improve range and stability of Z-wave network.
Supported switches
Module supports mono-stable switches (push button) and bi-stable
switches. The module is factory set to operate with bi-stable switches.
Installation
 Before the installation disconnect power supply.
 Connect the module according to electrical diagram.
 Locate the antenna far from metal elements (as far as possible).
 Do not shorten the antenna.
Danger of electrocution!
 Module installation requires a great degree of skill and may be
performed only by a qualified and licensed electrician.
 Even when the module is turned off, voltage may be present on its
terminals. Any works on configuration changes related to
connection mode or load must be always performed by
disconnected power supply (disable the fuse).
Note!
Do not connect the module to loads exceeding recommended values.
Connect the module only in accordance to the below diagrams.
Improper connections may be dangerous.
Package contents
 Flush heat and cool thermostat module + Temperature sensor
Electrical diagram 230VAC
Notes for the diagram:
*For details please check parameter 11 and 12 description
Electrical diagram 24VDC
Notes for the diagram:
*For details please check parameter 11 and 12 description
Durability of the module relay depends on applied load. For resistive
load (light bulbs, etc.) and 4A current consumption of each individual
electrical device, the durability exceeds 70.000 switches of each
individual electrical device.
Module Inclusion (Adding to Z-wave network)
 Connect module to power supply (with temperature sensor
connected),
 bring module within max. 1 meter (3 feet) of the main controller
 enable add/remove mode on main controller
 auto-inclusion (30 minutes after connected to power supply) or
 press service button S for more than 2 second or
 press push button I1 three times within 3s (3 times change switch
state within 3 seconds)
Module Exclusion/Reset (Removing from Z-Wave
network)
 Connect module to power supply,
 bring module within max. 1 meter (3 feet) of the main controller,
 enable add/remove mode on main controller
 press service button S for more than 6 second or
 press push button I1 five times within 3s (5 times change switch
state within 3 seconds) in the first 60 seconds after the module is
connected to the power supply.
By this function all parameters of the module are set to default values
and own ID is deleted. If service button S is pressed more than 2 and
less than 6 second module is excluded, but configuration parameters
are not set to default values.
Association
Association enables Flush heat and cool thermostat module to transfer
commands inside Z-Wave network directly (without main controller) to
other Z-Wave modules.
Associated Groups:
Group 1: basic on/off (triggered at change of the output Q1 state and
reflecting its state) up to 16 nodes.
Group 2: basic on/off (triggered at change of the output Q2 state and
reflecting its state) up to 16 nodes.
Group 3: basic on/off (triggered at change of thermostat mode Off/Auto
and reflecting its state) up to 16 nodes.
Group 4: basic on/off (triggered by Too high temperature limit, it send FF)
up to 16 nodes.
Group 5: basic on/off (triggered by Too low temperature limit, it send FF)
up to 16 nodes.
Group 6: default reporting group (reserved for the main controller).
Configuration parameters
Parameter no. 1 – Input 1 switch type
Available configuration parameters (data type is 1 Byte DEC):
 default value 1
 0 mono-stable switch type (push button)
 1 bi-stable switch type
Parameter no. 2 – Input 2 switch type
Available configuration parameters (data type is 1 Byte DEC):
 default value 1
 0 mono-stable switch type (push button)
 1 bi-stable switch type
Parameter no. 3 – Input 1 contact type
Available configuration parameters (data type is 1 Byte DEC):
 default value 0
 0 NO (normally open) input type
 1 NC (normally close) input type
Parameter no.4 – Input 2 contact type
Available configuration parameters (data type is 1 Byte DEC):
 default value 0
 0 NO (normally open) input type
 1 NC (normally close) input type
Parameter no. 5 – Input 1 status on delay
Available configuration parameters (data type is 2 Byte DEC):
 default value 0
 1 – 32000 seconds
If the value of parameter is different to 0, means that the status of the
digital input (parameter 11 must be set to 2 – window sensor) will switch
to tripped after the inserted time has expired.
Parameter no. 6 – Input 1 status off delay
Available configuration parameters (data type is 2 Byte DEC):
 default value 0
 1 – 32000 seconds
If the value of parameter is different to 0, means that the status of the
digital input (parameter 11 must be set to 2 – window sensor) will switch
from tripped to untripped after the inserted time has expired.
Parameter no. 7 – Input 2 status on delay
Available configuration parameters (data type is 2 Byte DEC):
 default value 0
 1 – 32000 seconds
If the value of parameter is different to 0, means that the status of the
digital input (parameter 12 must be set to 2000 – condense sensor) will
switch to tripped after the inserted time has expired.
Parameter no.8 – Input 2 status off delay
Available configuration parameters (data type is 2 Byte DEC):
 default value 0
 1 – 32000 seconds
If the value of parameter is different to 0, means that the status of the
digital input (parameter 12 must be set to 2000 – condense sensor) will
switch from tripped to untripped after the inserted time (seconds) has
expired.
Parameter no. 10 - Activate / deactivate functions ALL ON/ALL OFF
Available configuration parameters (data type is 1 Byte DEC):
 default value 255
 255 - ALL ON active, ALL OFF active.
 0 - ALL ON is not active ALL OFF is not active
 1 - ALL ON is not active ALL OFF active
 2 - ALL ON active ALL OFF is not active
Flush heat and cool thermostat module responds to commands ALL ON
/ ALL OFF that may be sent by the main controller or by other controller
belonging to the system.
Parameter no. 11- I1 Functionality selection
Available configuration parameters (data type is 2 Byte DEC):
 default value 1
 65535 – input I1 does not influence on the heat/ cool process
 1 – input I1 changes the mode of the thermostat between Off and
Auto. In this case function on window sensor is disabled
 2 – input I1 influences on cooling and heating valves according to
status of window sensor. In this case function of Off and Auto
selection by I1 is disabled
Parameter no. 12 – I2 Functionality selection
Available configuration parameters (data type is 2 Byte DEC):
 default value 65535
 65535 – input I2 does not influence on the heat/ cool process
 From 0 to 990 – Temperature set point from 0.0 °C to 99.0 °C.
When I2 is pressed, it is automatically set temperature setpoint
according to value defined here. In this case function of condense
sensor is disabled
 From 1001 to 1150 – Temperature set point from -0.1 °C to -15.0
°C When I2 is pressed, it is automatically set temperature
setpoint according to value defined here. In this case function of
condense sensor is disabled
N Neutral lead
L Live lead
Q1 Output for Heating valve
Q2 Output for Cooling valve
I2 Input for switch (configurable) *
I1 Input for switch (configurable) *
TS Terminal for digital temperature sensor (only for Flush heat
and cool thermostat module compatible digital temperature
sensor).
N + VDC
L - VDC
Q1 Output for Heating valve
Q2 Output for Cooling valve
I2 Input for switch (configurable) *
I1 Input for switch (configurable) *
TS Terminal for digital temperature sensor (only for Flush
heat and cool thermostat module compatible digital
temperature sensor).
S Service button (used to add or
remove module from the Z-Wave
network).
 2000 – Input I2 influences on the cooling valve according to status
of condense sensor, In this case function of setpoint selection with
I2 is disabled
Parameter no. 40–Power reporting in Watts on power change for Q1
Set value means percentage, set value from 0 - 100=0% - 100%.
Available configuration parameters (data type is 1 Byte DEC):
 default value 3
 0 – Reporting Disabled
 1–100 = 1%-100% Reporting enabled. Power report is send (push)
only when actual power in Watts in real time changes for more than set
percentage comparing to previous actual power in Watts, step is 1%.
NOTE: If power changed is less than 1W, the report is not send (pushed),
independent of percentage set.
Parameter no. 41–Power reporting in Watts on power change for Q2
Set value means percentage, set value from 0 – 100 = 0% - 100%.
Available configuration parameters (data type is 1 Byte DEC):
 default value 3
 0 – Reporting Disabled
 1 – 100 = 1% - 100% Reporting enabled. Power report is send
(push) only when actual power in Watts in real time changes for
more than set percentage comparing to previous actual power in
Watts, step is 1%.
NOTE: if power changed is less than 1W, the report is not send (pushed),
independent of percentage set.
Parameter no. 42 – Power reporting in Watts by time interval for Q1
Set value means time interval (0 – 65535) in seconds, when power
report is send. Available config. parameters (data type is 2 Byte DEC):
 default value 300 (power report in Watts is send each 300s)
 0 – Reporting Disabled
 1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power
report is send with time interval set by entered value.
Parameter no. 43 – Power reporting in Watts by time interval for Q2
Set value means time interval (0 – 65535) in seconds, when power
report is send. Available config. parameters (data type is 2 Byte DEC):
 default value 300 (power report in Watts is send each 300s)
 0 – Reporting Disabled
 1 – 65535 = 1 second – 65535 seconds. Reporting enabled, Power
report is send with time interval set by entered value.
Parameter no. 50 – Hysteresis Heating On
This parameter defines temperature difference between measured
temperature and set-point temperature to turn heating on. Parameter
can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C
and from 128 to 255 means from - 0.1 °C to -12.7 °C.
Available configuration parameters (data type is 1 Byte DEC):
 default value 137 (-1.0 °C)
Parameter no. 51 - Hysteresis Heating Off
This parameter defines temperature difference between measured
temperature and set-point temperature to turn heating off. Parameter
can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7°C
and from 128 to 255 means from - 0.1 °C to -12.7 °C.
Available configuration parameters (data type is 1 Byte DEC):
 default value 132 (-0.5 °C)
Parameter no. 52 – Hysteresis Cooling On
This parameter defines temperature difference between measured
temperature and set-point temperature to turn cooling on. Parameter
can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C
and from 128 to 255 means from - 0.1 °C to -12.7 °C.
Available configuration parameters (data type is 1 Byte DEC):
 default value 10 (1.0 °C)
Parameter no. 53 – Hysteresis Cooling Off
This parameter defines temperature difference between measured
temperature and set-point temperature to turn cooling off. Parameter
can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C
and from 128 to 255 means from - 0.1 °C to -12.7 °C.
Available configuration parameters (data type is 1 Byte DEC):
 default value 5 (+0.5 °C)
Parameter no. 54 – Antifreeze
Set value means at which temperature the heating will be turned on (to
prevent freezing) even if the thermostat was manually set to off.
Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C
to 12.7 °C and from 128 to 254 means from - 0.1 °C to -12.6 °C.
Available configuration parameters (data type is 1 Byte DEC):
 default value 50 (5,0 °C)
 255 – antifreeze functionality disabled
Parameter no. 60 – Too low temperature limit
Available configuration parameters (data type is 2 Byte DEC):
 Default value 50 (Too low temperature limit is 5.0°C)
 1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit
is set by entered value. In case measured temperature is below set
value, module send BasicSet value. Look chapter associations.
Parameter no. 61 – Too high temperature limit
Available configuration parameters (data type is 2 Byte DEC):
 Default value 700 (too high temperature limit is 70.0°C)
 1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too high temperature limit
is set by entered value. In case measured temperature is higher
than set value, module send BasicSet value. Look chapter
associations.
Parameter no. 64 – Q1 Switch selection
Set value means the type of the heating device that is connected to the
relay output. The heating device type can be normally open (NO) or
normally close (NC).
Available configuration parameters (data type is 1 Byte DEC):
 default value 0
 0 - When system is turned off the output is 0VAC (NC).
 1 - When system is turned off the output is 230VAC (NO)
Parameter no. 65 – Q2 Switch selection
Set value means the type of the cooling device that is connected to the
relay output. The cooling device type can be normally open (NO) or
normally close (NC).
Available configuration parameters (data type is 1 Byte DEC):
 default value 0
 0 - When system is turned off the output is 0VAC (NC).
 1 - When system is turned off the output is 230VAC (NO).
Functionality
Thermostat has 2 working mode, Off or Auto. Selection between Off and
Auto is possible to select with I1 push button or from gateway. When the
thermostat is turned On, it automatically regulates temperature
according to picture below:
When the temperature is decreasing and reaches point ‘Heating On’
(defined by parameter 50), heating is turned on and remains active until
the temperature in the room is not increased to reach ‘Heating Off’
(defined by parameter 51). At this point heating and cooling valve are
turned off – deadband zone. If the temperature rises over ‘Cooling On’
(defined by parameter 52) point the cooling valve will switch on. The
consequence will be temperature dropping, and when temperature
drops below ‘Cooling Off’ (defined by parameter 53) cooling valve will
switch off.
When the thermostat is turned off, then it is working in antifreeze regime.
The antifreeze regime turns on heating when the temperature is lower or
equal to the temperature set by parameter 54 (Default 5.0C).
Energy saving mode:
If parameter 11 is set to value 2 and if the state of the input I1 is active
(window opened active) both outputs (Q1 and Q2) are turned off.
Condensation:
If parameter 12 is set to value 2000 and if the state of the input I2 is
active (condensation sensor active) Q2 output (cooling) is turned off.
Temperature limits
 Temperature too low is send when the actual temperature is equal
or smaller to the value set by parameter 60 (Check Associated
Groups)
 Temperature too high is send when the actual temperature is equal
or higher to the value set by parameter 61. (Check Associated
Groups)
Technical Specifications
Power supply
110-230VAC ±10% 50/60Hz,
24-30VDC
Rated load current of AC output
(resistive load)
2 X 4A / 230VAC
Rated load current of DC output
(resistive load)
2 X 4A / 30VDC
Output circuit power of AC output
(resistive load)
2 X 920W (230VAC)
Output circuit power of DC output
(resistive load)
2 X 96W (24VDC)
Power monitoring accuracy
P=0-200W, +/-2W; P˃200W,
+/-3%
Operation temperature -10 ~ 40°C
Distance
up to 30 meters indoors
(depending on building materials)
Dimensions (WxHxD) (package) 41,8x36,8x16,9mm (115x96x22)
Weight (Brutto with package) 48g (64g)
Electricity consumption 0,4W
For installation in boxes Ø ≥ 60mm or 2M
Switching Relay (2x)
Digital temperature sensor range -50.0 ~ 125.0°C, resolution 0.1°C
Digital temperature sensor cable
length
1000mm
* In case of load other than resistive, pay attention to the value of cos φ
and if necessary apply load lower than the rated load. Max current for
cos φ=0,4 is 2A at 250VAC, 3A at 24VDC.
Z-Wave Device Class:
BASIC_TYPE_ROUTING_SLAVE
GENERIC_TYPE_THERMOSTAT
SPECIFIC_TYPE_SETPOINT_THERMOSTAT
Z-Wave Supported CommandClasses:
COMMAND_CLASS_THERMOSTAT_SETPOINT v2
COMMAND_CLASS_VERSION v1
COMMAND_CLASS_MANUFACTURER_SPECIFIC v1
COMMAND_CLASS_MULTI_CMD v1
COMMAND_CLASS_SENSOR_MULTILEVEL v3
COMMAND_CLASS_ASSOCIATION v1
COMMAND_CLASS_CONFIGURATION v1
COMMAND_CLASS_POWERLEVEL v1
COMMAND_CLASS_METER v3
COMMAND_CLASS_THERMOSTAT_MODE v2
COMMAND_CLASS_MARK
COMMAND_CLASS_BASIC v1
COMMAND_CLASS_NO_OPERATION
Endpoint 2 (I1):
Device Class:
GENERIC_TYPE_SWITCH_BINARY
SPECIFIC_TYPE_POWER_SWITCH_BINARY
Command Classes:
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_METER_V3
Endpoint 3 (I2):
Device Class:
GENERIC_TYPE_SWITCH_BINARY
SPECIFIC_TYPE_POWER_SWITCH_BINARY
Command Classes:
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_METER_V3
COMMAND_CLASS_BASIC
The basic command class supports the functions BASIC SET and
BASIC GET. Through the function basic SET is possible to set the mode
of the module. Basic SET can send the values 0xff which means Auto
and 0x00 which means Off. Through the function basic GET is possible
to read the mode of the module. The module returns 0xff which means
Auto or 0x00 which means Off.
COMMAND_CLASS_SENSOR_MULTILEVEL
The Flush on/off thermostat supports reading of actual temperature
which is 2 bytes long, scale is °C and its precision is 1(it means 0,1°C).
COMMAND_CLASS_THERMOSTAT_MODE
The Flush heat & cool thermostat supports the following modes:
 Mode Off
 Mode Auto
COMMAND_CLASS_THERMOSTAT_SETPOINT
The Flush on/off thermostat supports temperature set point, which is
2 bytes long, scale is °C and its precision is 1(it means 0,1°C).
This product can be included and operated in any Z-Wave network with
other Z-Wave certified devices from any other manufacturers. All
constantly powered nodes in the same network will act as repeaters
regardless of the vendor in order to increase reliability of the network.
Important disclaimer
Z-Wave wireless communication is inherently not always 100% reliable,
and as such, this product should not be used in situations in which life
and/or valuables are solely dependent on its function.
Warning!
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
Contact your local government for information regarding the collection
systems available. If electrical appliances are disposed of in landfills or
dumps, hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being. When
replacing old appliances with new once, the retailer is legally obligated to
take back your old appliance for disposal at least for free of charge.
This user manual is subject to change and improvement without notice.
Qubino
Goap d.o.o. Nova Gorica
Ulica Klementa Juga 007
5250 Solkan
Slovenia
E-mail: info@qubino.com
Tel: +386 5 335 95 00
Web: www.qubino.com
Date: 13.04.2015
Document: Qubino_Flush heat & cool
thermostat user manual_V1.2_eng
Temperature control:
Heating
Hysteresis
Heating
On
Off
Hysteresis
Cooling
Cooling
T actualSP
On OnOff Off

More Related Content

PDF
Micro double switch module qubino manual
Domotica daVinci
 
PDF
Mh7 eu um v.02
Domotica daVinci
 
PDF
Mini Socket Dimmer Z-Wave Everspring manual
Domotica daVinci
 
PDF
Manual SEC_SCS317 secure
Domotica daVinci
 
PDF
Philio_pan06_User manual
Domotica daVinci
 
PDF
Micro switch module qubino manual
Domotica daVinci
 
PDF
Single On Off Relay Everspring Manual
Domotica daVinci
 
PDF
Mini jack on off and counter z wave plus everspring
Domotica daVinci
 
Micro double switch module qubino manual
Domotica daVinci
 
Mh7 eu um v.02
Domotica daVinci
 
Mini Socket Dimmer Z-Wave Everspring manual
Domotica daVinci
 
Manual SEC_SCS317 secure
Domotica daVinci
 
Philio_pan06_User manual
Domotica daVinci
 
Micro switch module qubino manual
Domotica daVinci
 
Single On Off Relay Everspring Manual
Domotica daVinci
 
Mini jack on off and counter z wave plus everspring
Domotica daVinci
 

What's hot (20)

PDF
Qubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
Domotica daVinci
 
PDF
4 in 1 multi sensor Philio PSM02 (motion, door/window, temperature, lightness)
Domotica daVinci
 
PDF
DUW 05459
Domotica daVinci
 
PDF
Qubino flush 1 relay plus user manual v1.0 eng1
Domotica daVinci
 
PDF
Secure SRT322_User__Installation_instructions
Domotica daVinci
 
PDF
Manual dimmer benext us
Domotica daVinci
 
PDF
Ph pan04-zipato-micro-module-switch-double-user-manual-v1.4
Domotica daVinci
 
PDF
Manual SEC_SCS318 secure
Domotica daVinci
 
PDF
Qubino flush 1D relay user manual
Domotica daVinci
 
PDF
Philio_pan04_User manual
Domotica daVinci
 
PDF
Mini price on off z wave plus everspring
Domotica daVinci
 
PDF
Instructions aeon labs wall plug smart dimmer 6
Domotica daVinci
 
PDF
Mco_tps314
Domotica daVinci
 
PDF
manual dimmer - Zipato
Domotica daVinci
 
PDF
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
Domotica daVinci
 
PDF
Mh8 fc um
Domotica daVinci
 
PDF
Aeotec Multisensor 7 Manual
Domotica daVinci
 
PDF
Philio_pan08_manual
Domotica daVinci
 
PDF
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
Domotica daVinci
 
PDF
Micromodule Mural On/Off Z-Wave Plus AN179 Smart Home Europe manual english
Domotica daVinci
 
Qubino flush dimmer Z-Wave Plus ZMNHDD1 Manual
Domotica daVinci
 
4 in 1 multi sensor Philio PSM02 (motion, door/window, temperature, lightness)
Domotica daVinci
 
DUW 05459
Domotica daVinci
 
Qubino flush 1 relay plus user manual v1.0 eng1
Domotica daVinci
 
Secure SRT322_User__Installation_instructions
Domotica daVinci
 
Manual dimmer benext us
Domotica daVinci
 
Ph pan04-zipato-micro-module-switch-double-user-manual-v1.4
Domotica daVinci
 
Manual SEC_SCS318 secure
Domotica daVinci
 
Qubino flush 1D relay user manual
Domotica daVinci
 
Philio_pan04_User manual
Domotica daVinci
 
Mini price on off z wave plus everspring
Domotica daVinci
 
Instructions aeon labs wall plug smart dimmer 6
Domotica daVinci
 
Mco_tps314
Domotica daVinci
 
manual dimmer - Zipato
Domotica daVinci
 
3 in 1 multisensor Philio PSP01 manual (motion, Temperature, lightness)
Domotica daVinci
 
Mh8 fc um
Domotica daVinci
 
Aeotec Multisensor 7 Manual
Domotica daVinci
 
Philio_pan08_manual
Domotica daVinci
 
In-wall dimmer module Z-Wave Plus Smart Home Europe manual english
Domotica daVinci
 
Micromodule Mural On/Off Z-Wave Plus AN179 Smart Home Europe manual english
Domotica daVinci
 
Ad

Similar to Qubino flush heat__cool_thermostat_user-manual_v1.2_eng (20)

PDF
Qubino dimmer manual
Domotica daVinci
 
PDF
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Domotica daVinci
 
PDF
Micro dimmer module qubino manual
Domotica daVinci
 
PDF
Micro dimmer module qubino manual
Domotica daVinci
 
PDF
Manual Qubino smart meter plus
Domotica daVinci
 
PDF
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Domotica daVinci
 
PPTX
Maxvu tech support lvl presentation na
West Control Solutions
 
PDF
Neo coolcam - smart-plug user guide v2 - Zwave
Thierry Zoller
 
PDF
ES-21-FIB-FGS-222 Micromodule double switch FGS-222 Z-Wave - Fibaro
Domotica daVinci
 
PDF
Temperature sensor with binary sensor input start guide
Domotica daVinci
 
PDF
Fgs 212-en-a-v1.01
TOMAS GARCIA VERDUGO
 
PDF
R38 Controller
Joseph
 
PDF
For mim olite
Domotica daVinci
 
PDF
Pop 123610 manual
Domotica daVinci
 
PDF
Manual Outdoor motion detector Z-Wave Plus - Philio
Domotica daVinci
 
PDF
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Domotica daVinci
 
PDF
Manual zmnhxd1
Domotica daVinci
 
PDF
Thông số kỹ thuật bộ điều khiển nhiệt temcoline, Catalogue bộ điều khiển nhiệt
Công ty cổ phần OKS | Tổng thầu thi công Nhà máy GMP, Tổng thầu thi công Nhà kho GSP
 
PPTX
Digital Temperature Controllers
Dwyer Instruments
 
PDF
ICplus902_Manual_EN.pdf iskkksmmsmmmskakjdskla
BaronRafiBabian
 
Qubino dimmer manual
Domotica daVinci
 
Qubino flush dimmer 0 10-v plus user manual_v1.0_eng
Domotica daVinci
 
Micro dimmer module qubino manual
Domotica daVinci
 
Micro dimmer module qubino manual
Domotica daVinci
 
Manual Qubino smart meter plus
Domotica daVinci
 
Wall Plug switch with Metering Z-Wave.me ZME_064374 manual english
Domotica daVinci
 
Maxvu tech support lvl presentation na
West Control Solutions
 
Neo coolcam - smart-plug user guide v2 - Zwave
Thierry Zoller
 
ES-21-FIB-FGS-222 Micromodule double switch FGS-222 Z-Wave - Fibaro
Domotica daVinci
 
Temperature sensor with binary sensor input start guide
Domotica daVinci
 
Fgs 212-en-a-v1.01
TOMAS GARCIA VERDUGO
 
R38 Controller
Joseph
 
For mim olite
Domotica daVinci
 
Pop 123610 manual
Domotica daVinci
 
Manual Outdoor motion detector Z-Wave Plus - Philio
Domotica daVinci
 
Manual Motion sensor Outdoor Z-Wave Plus Round Insert - Philio
Domotica daVinci
 
Manual zmnhxd1
Domotica daVinci
 
Thông số kỹ thuật bộ điều khiển nhiệt temcoline, Catalogue bộ điều khiển nhiệt
Công ty cổ phần OKS | Tổng thầu thi công Nhà máy GMP, Tổng thầu thi công Nhà kho GSP
 
Digital Temperature Controllers
Dwyer Instruments
 
ICplus902_Manual_EN.pdf iskkksmmsmmmskakjdskla
BaronRafiBabian
 
Ad

More from Domotica daVinci (20)

PDF
Manual de usuario Dongle Zigbee 3.0 Sonoff
Domotica daVinci
 
PDF
2Channel Dimmer Module Zigbee NetPlus Manual
Domotica daVinci
 
PDF
Shelly Qubini Dry Contact Module Z-Wave Manual
Domotica daVinci
 
PDF
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
Domotica daVinci
 
PDF
Manual controlador de pared Zigbee quatro battery.pdf
Domotica daVinci
 
PDF
MOES-User-Manual AL23-211223-MHUB-MS.pdf
Domotica daVinci
 
PDF
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
Domotica daVinci
 
PDF
Cherubini Meta Z-Wave Double Switch A510083-84-90
Domotica daVinci
 
PDF
Cherubini Meta Z-Wave Smart Plug Manual A510068
Domotica daVinci
 
PDF
Wave_Shutter_user_guide_multilang_print_V3.pdf
Domotica daVinci
 
PDF
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Domotica daVinci
 
PDF
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Domotica daVinci
 
PDF
Manual Eurotronic Thermostatic Valve Comry Z-Wave
Domotica daVinci
 
PDF
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
Domotica daVinci
 
PDF
zigbee motion sensor user manual NAS-PD07B2.pdf
Domotica daVinci
 
PDF
Range extender 7 - Aeotec - Manual
Domotica daVinci
 
PDF
Z stick 7 user guide
Domotica daVinci
 
PDF
ESB 200 H-Tronic Manual
Domotica daVinci
 
PDF
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
Domotica daVinci
 
PDF
wiDom Smart dry contact module Z-Wave Plus Manual
Domotica daVinci
 
Manual de usuario Dongle Zigbee 3.0 Sonoff
Domotica daVinci
 
2Channel Dimmer Module Zigbee NetPlus Manual
Domotica daVinci
 
Shelly Qubini Dry Contact Module Z-Wave Manual
Domotica daVinci
 
Zi-Stick UBS Dongle ZIgbee from Aeotec manual
Domotica daVinci
 
Manual controlador de pared Zigbee quatro battery.pdf
Domotica daVinci
 
MOES-User-Manual AL23-211223-MHUB-MS.pdf
Domotica daVinci
 
Tete thermostatique Zigbee MOES BRT-100 V2.pdf
Domotica daVinci
 
Cherubini Meta Z-Wave Double Switch A510083-84-90
Domotica daVinci
 
Cherubini Meta Z-Wave Smart Plug Manual A510068
Domotica daVinci
 
Wave_Shutter_user_guide_multilang_print_V3.pdf
Domotica daVinci
 
Quinto Z-Wave Heltun_HE-RS01_User_Manual_B9AH.pdf
Domotica daVinci
 
Z-Wave Fan coil Thermostat Heltun_HE-HT01_User_Manual.pdf
Domotica daVinci
 
Manual Eurotronic Thermostatic Valve Comry Z-Wave
Domotica daVinci
 
Manual sensor Zigbee 3.0 MOES ZSS-X-PIRL-C
Domotica daVinci
 
zigbee motion sensor user manual NAS-PD07B2.pdf
Domotica daVinci
 
Range extender 7 - Aeotec - Manual
Domotica daVinci
 
Z stick 7 user guide
Domotica daVinci
 
ESB 200 H-Tronic Manual
Domotica daVinci
 
wiDom Smart Roller Shutter Z-Wave Plus Module Manual
Domotica daVinci
 
wiDom Smart dry contact module Z-Wave Plus Manual
Domotica daVinci
 

Recently uploaded (20)

PDF
Advances in Ultra High Voltage (UHV) Transmission and Distribution Systems.pdf
Nabajyoti Banik
 
PDF
Event Presentation Google Cloud Next Extended 2025
minhtrietgect
 
PDF
Doc9.....................................
SofiaCollazos
 
PDF
AI Unleashed - Shaping the Future -Starting Today - AIOUG Yatra 2025 - For Co...
Sandesh Rao
 
PDF
A Strategic Analysis of the MVNO Wave in Emerging Markets.pdf
IPLOOK Networks
 
PDF
MASTERDECK GRAPHSUMMIT SYDNEY (Public).pdf
Neo4j
 
PDF
Using Anchore and DefectDojo to Stand Up Your DevSecOps Function
Anchore
 
PDF
How-Cloud-Computing-Impacts-Businesses-in-2025-and-Beyond.pdf
Artjoker Software Development Company
 
PDF
AI-Cloud-Business-Management-Platforms-The-Key-to-Efficiency-Growth.pdf
Artjoker Software Development Company
 
PPTX
AI and Robotics for Human Well-being.pptx
JAYMIN SUTHAR
 
PDF
Accelerating Oracle Database 23ai Troubleshooting with Oracle AHF Fleet Insig...
Sandesh Rao
 
PDF
Make GenAI investments go further with the Dell AI Factory
Principled Technologies
 
PDF
Responsible AI and AI Ethics - By Sylvester Ebhonu
Sylvester Ebhonu
 
PDF
Software Development Methodologies in 2025
KodekX
 
PPTX
AI in Daily Life: How Artificial Intelligence Helps Us Every Day
vanshrpatil7
 
PDF
Google I/O Extended 2025 Baku - all ppts
HusseinMalikMammadli
 
PDF
Security features in Dell, HP, and Lenovo PC systems: A research-based compar...
Principled Technologies
 
PDF
Get More from Fiori Automation - What’s New, What Works, and What’s Next.pdf
Precisely
 
PDF
Automating ArcGIS Content Discovery with FME: A Real World Use Case
Safe Software
 
PDF
NewMind AI Weekly Chronicles - July'25 - Week IV
NewMind AI
 
Advances in Ultra High Voltage (UHV) Transmission and Distribution Systems.pdf
Nabajyoti Banik
 
Event Presentation Google Cloud Next Extended 2025
minhtrietgect
 
Doc9.....................................
SofiaCollazos
 
AI Unleashed - Shaping the Future -Starting Today - AIOUG Yatra 2025 - For Co...
Sandesh Rao
 
A Strategic Analysis of the MVNO Wave in Emerging Markets.pdf
IPLOOK Networks
 
MASTERDECK GRAPHSUMMIT SYDNEY (Public).pdf
Neo4j
 
Using Anchore and DefectDojo to Stand Up Your DevSecOps Function
Anchore
 
How-Cloud-Computing-Impacts-Businesses-in-2025-and-Beyond.pdf
Artjoker Software Development Company
 
AI-Cloud-Business-Management-Platforms-The-Key-to-Efficiency-Growth.pdf
Artjoker Software Development Company
 
AI and Robotics for Human Well-being.pptx
JAYMIN SUTHAR
 
Accelerating Oracle Database 23ai Troubleshooting with Oracle AHF Fleet Insig...
Sandesh Rao
 
Make GenAI investments go further with the Dell AI Factory
Principled Technologies
 
Responsible AI and AI Ethics - By Sylvester Ebhonu
Sylvester Ebhonu
 
Software Development Methodologies in 2025
KodekX
 
AI in Daily Life: How Artificial Intelligence Helps Us Every Day
vanshrpatil7
 
Google I/O Extended 2025 Baku - all ppts
HusseinMalikMammadli
 
Security features in Dell, HP, and Lenovo PC systems: A research-based compar...
Principled Technologies
 
Get More from Fiori Automation - What’s New, What Works, and What’s Next.pdf
Precisely
 
Automating ArcGIS Content Discovery with FME: A Real World Use Case
Safe Software
 
NewMind AI Weekly Chronicles - July'25 - Week IV
NewMind AI
 

Qubino flush heat__cool_thermostat_user-manual_v1.2_eng

  • 1. Qubino The INNOVATIVE and SMALLEST Flush heat & cool thermostat ORDERING CODE Z-WAVE FREQUENCY ZMNHKA2 868,4 MHz ZMNHKA3 921,4 MHz ZMNHKA4 908,4 MHz ZMNHKA5 869,0 MHz ZMNHKA6 916,0 MHz This Z-Wave module is used to regulate temperature in heating and cooling mode. The module can be controlled either through Z-wave network or through the wall switch. The module is designed to be mounted inside a “flush mounting box” and is hidden behind a traditional wall switch. Module measures power consumption of connected device. It is designed to act as repeater in order to improve range and stability of Z-wave network. Supported switches Module supports mono-stable switches (push button) and bi-stable switches. The module is factory set to operate with bi-stable switches. Installation  Before the installation disconnect power supply.  Connect the module according to electrical diagram.  Locate the antenna far from metal elements (as far as possible).  Do not shorten the antenna. Danger of electrocution!  Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician.  Even when the module is turned off, voltage may be present on its terminals. Any works on configuration changes related to connection mode or load must be always performed by disconnected power supply (disable the fuse). Note! Do not connect the module to loads exceeding recommended values. Connect the module only in accordance to the below diagrams. Improper connections may be dangerous. Package contents  Flush heat and cool thermostat module + Temperature sensor Electrical diagram 230VAC Notes for the diagram: *For details please check parameter 11 and 12 description Electrical diagram 24VDC Notes for the diagram: *For details please check parameter 11 and 12 description Durability of the module relay depends on applied load. For resistive load (light bulbs, etc.) and 4A current consumption of each individual electrical device, the durability exceeds 70.000 switches of each individual electrical device. Module Inclusion (Adding to Z-wave network)  Connect module to power supply (with temperature sensor connected),  bring module within max. 1 meter (3 feet) of the main controller  enable add/remove mode on main controller  auto-inclusion (30 minutes after connected to power supply) or  press service button S for more than 2 second or  press push button I1 three times within 3s (3 times change switch state within 3 seconds) Module Exclusion/Reset (Removing from Z-Wave network)  Connect module to power supply,  bring module within max. 1 meter (3 feet) of the main controller,  enable add/remove mode on main controller  press service button S for more than 6 second or  press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply. By this function all parameters of the module are set to default values and own ID is deleted. If service button S is pressed more than 2 and less than 6 second module is excluded, but configuration parameters are not set to default values. Association Association enables Flush heat and cool thermostat module to transfer commands inside Z-Wave network directly (without main controller) to other Z-Wave modules. Associated Groups: Group 1: basic on/off (triggered at change of the output Q1 state and reflecting its state) up to 16 nodes. Group 2: basic on/off (triggered at change of the output Q2 state and reflecting its state) up to 16 nodes. Group 3: basic on/off (triggered at change of thermostat mode Off/Auto and reflecting its state) up to 16 nodes. Group 4: basic on/off (triggered by Too high temperature limit, it send FF) up to 16 nodes. Group 5: basic on/off (triggered by Too low temperature limit, it send FF) up to 16 nodes. Group 6: default reporting group (reserved for the main controller). Configuration parameters Parameter no. 1 – Input 1 switch type Available configuration parameters (data type is 1 Byte DEC):  default value 1  0 mono-stable switch type (push button)  1 bi-stable switch type Parameter no. 2 – Input 2 switch type Available configuration parameters (data type is 1 Byte DEC):  default value 1  0 mono-stable switch type (push button)  1 bi-stable switch type Parameter no. 3 – Input 1 contact type Available configuration parameters (data type is 1 Byte DEC):  default value 0  0 NO (normally open) input type  1 NC (normally close) input type Parameter no.4 – Input 2 contact type Available configuration parameters (data type is 1 Byte DEC):  default value 0  0 NO (normally open) input type  1 NC (normally close) input type Parameter no. 5 – Input 1 status on delay Available configuration parameters (data type is 2 Byte DEC):  default value 0  1 – 32000 seconds If the value of parameter is different to 0, means that the status of the digital input (parameter 11 must be set to 2 – window sensor) will switch to tripped after the inserted time has expired. Parameter no. 6 – Input 1 status off delay Available configuration parameters (data type is 2 Byte DEC):  default value 0  1 – 32000 seconds If the value of parameter is different to 0, means that the status of the digital input (parameter 11 must be set to 2 – window sensor) will switch from tripped to untripped after the inserted time has expired. Parameter no. 7 – Input 2 status on delay Available configuration parameters (data type is 2 Byte DEC):  default value 0  1 – 32000 seconds If the value of parameter is different to 0, means that the status of the digital input (parameter 12 must be set to 2000 – condense sensor) will switch to tripped after the inserted time has expired. Parameter no.8 – Input 2 status off delay Available configuration parameters (data type is 2 Byte DEC):  default value 0  1 – 32000 seconds If the value of parameter is different to 0, means that the status of the digital input (parameter 12 must be set to 2000 – condense sensor) will switch from tripped to untripped after the inserted time (seconds) has expired. Parameter no. 10 - Activate / deactivate functions ALL ON/ALL OFF Available configuration parameters (data type is 1 Byte DEC):  default value 255  255 - ALL ON active, ALL OFF active.  0 - ALL ON is not active ALL OFF is not active  1 - ALL ON is not active ALL OFF active  2 - ALL ON active ALL OFF is not active Flush heat and cool thermostat module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. Parameter no. 11- I1 Functionality selection Available configuration parameters (data type is 2 Byte DEC):  default value 1  65535 – input I1 does not influence on the heat/ cool process  1 – input I1 changes the mode of the thermostat between Off and Auto. In this case function on window sensor is disabled  2 – input I1 influences on cooling and heating valves according to status of window sensor. In this case function of Off and Auto selection by I1 is disabled Parameter no. 12 – I2 Functionality selection Available configuration parameters (data type is 2 Byte DEC):  default value 65535  65535 – input I2 does not influence on the heat/ cool process  From 0 to 990 – Temperature set point from 0.0 °C to 99.0 °C. When I2 is pressed, it is automatically set temperature setpoint according to value defined here. In this case function of condense sensor is disabled  From 1001 to 1150 – Temperature set point from -0.1 °C to -15.0 °C When I2 is pressed, it is automatically set temperature setpoint according to value defined here. In this case function of condense sensor is disabled N Neutral lead L Live lead Q1 Output for Heating valve Q2 Output for Cooling valve I2 Input for switch (configurable) * I1 Input for switch (configurable) * TS Terminal for digital temperature sensor (only for Flush heat and cool thermostat module compatible digital temperature sensor). N + VDC L - VDC Q1 Output for Heating valve Q2 Output for Cooling valve I2 Input for switch (configurable) * I1 Input for switch (configurable) * TS Terminal for digital temperature sensor (only for Flush heat and cool thermostat module compatible digital temperature sensor). S Service button (used to add or remove module from the Z-Wave network).
  • 2.  2000 – Input I2 influences on the cooling valve according to status of condense sensor, In this case function of setpoint selection with I2 is disabled Parameter no. 40–Power reporting in Watts on power change for Q1 Set value means percentage, set value from 0 - 100=0% - 100%. Available configuration parameters (data type is 1 Byte DEC):  default value 3  0 – Reporting Disabled  1–100 = 1%-100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: If power changed is less than 1W, the report is not send (pushed), independent of percentage set. Parameter no. 41–Power reporting in Watts on power change for Q2 Set value means percentage, set value from 0 – 100 = 0% - 100%. Available configuration parameters (data type is 1 Byte DEC):  default value 3  0 – Reporting Disabled  1 – 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. Parameter no. 42 – Power reporting in Watts by time interval for Q1 Set value means time interval (0 – 65535) in seconds, when power report is send. Available config. parameters (data type is 2 Byte DEC):  default value 300 (power report in Watts is send each 300s)  0 – Reporting Disabled  1 – 65535 = 1second – 65535 seconds. Reporting enabled. Power report is send with time interval set by entered value. Parameter no. 43 – Power reporting in Watts by time interval for Q2 Set value means time interval (0 – 65535) in seconds, when power report is send. Available config. parameters (data type is 2 Byte DEC):  default value 300 (power report in Watts is send each 300s)  0 – Reporting Disabled  1 – 65535 = 1 second – 65535 seconds. Reporting enabled, Power report is send with time interval set by entered value. Parameter no. 50 – Hysteresis Heating On This parameter defines temperature difference between measured temperature and set-point temperature to turn heating on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C. Available configuration parameters (data type is 1 Byte DEC):  default value 137 (-1.0 °C) Parameter no. 51 - Hysteresis Heating Off This parameter defines temperature difference between measured temperature and set-point temperature to turn heating off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7°C and from 128 to 255 means from - 0.1 °C to -12.7 °C. Available configuration parameters (data type is 1 Byte DEC):  default value 132 (-0.5 °C) Parameter no. 52 – Hysteresis Cooling On This parameter defines temperature difference between measured temperature and set-point temperature to turn cooling on. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C. Available configuration parameters (data type is 1 Byte DEC):  default value 10 (1.0 °C) Parameter no. 53 – Hysteresis Cooling Off This parameter defines temperature difference between measured temperature and set-point temperature to turn cooling off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 255 means from - 0.1 °C to -12.7 °C. Available configuration parameters (data type is 1 Byte DEC):  default value 5 (+0.5 °C) Parameter no. 54 – Antifreeze Set value means at which temperature the heating will be turned on (to prevent freezing) even if the thermostat was manually set to off. Parameter can be set from 0 to 255 where 0 to 127 means from 0.0 °C to 12.7 °C and from 128 to 254 means from - 0.1 °C to -12.6 °C. Available configuration parameters (data type is 1 Byte DEC):  default value 50 (5,0 °C)  255 – antifreeze functionality disabled Parameter no. 60 – Too low temperature limit Available configuration parameters (data type is 2 Byte DEC):  Default value 50 (Too low temperature limit is 5.0°C)  1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too low temperature limit is set by entered value. In case measured temperature is below set value, module send BasicSet value. Look chapter associations. Parameter no. 61 – Too high temperature limit Available configuration parameters (data type is 2 Byte DEC):  Default value 700 (too high temperature limit is 70.0°C)  1 - 1000 = 0.1°C – 100.0°C, step is 0.1°C. Too high temperature limit is set by entered value. In case measured temperature is higher than set value, module send BasicSet value. Look chapter associations. Parameter no. 64 – Q1 Switch selection Set value means the type of the heating device that is connected to the relay output. The heating device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC):  default value 0  0 - When system is turned off the output is 0VAC (NC).  1 - When system is turned off the output is 230VAC (NO) Parameter no. 65 – Q2 Switch selection Set value means the type of the cooling device that is connected to the relay output. The cooling device type can be normally open (NO) or normally close (NC). Available configuration parameters (data type is 1 Byte DEC):  default value 0  0 - When system is turned off the output is 0VAC (NC).  1 - When system is turned off the output is 230VAC (NO). Functionality Thermostat has 2 working mode, Off or Auto. Selection between Off and Auto is possible to select with I1 push button or from gateway. When the thermostat is turned On, it automatically regulates temperature according to picture below: When the temperature is decreasing and reaches point ‘Heating On’ (defined by parameter 50), heating is turned on and remains active until the temperature in the room is not increased to reach ‘Heating Off’ (defined by parameter 51). At this point heating and cooling valve are turned off – deadband zone. If the temperature rises over ‘Cooling On’ (defined by parameter 52) point the cooling valve will switch on. The consequence will be temperature dropping, and when temperature drops below ‘Cooling Off’ (defined by parameter 53) cooling valve will switch off. When the thermostat is turned off, then it is working in antifreeze regime. The antifreeze regime turns on heating when the temperature is lower or equal to the temperature set by parameter 54 (Default 5.0C). Energy saving mode: If parameter 11 is set to value 2 and if the state of the input I1 is active (window opened active) both outputs (Q1 and Q2) are turned off. Condensation: If parameter 12 is set to value 2000 and if the state of the input I2 is active (condensation sensor active) Q2 output (cooling) is turned off. Temperature limits  Temperature too low is send when the actual temperature is equal or smaller to the value set by parameter 60 (Check Associated Groups)  Temperature too high is send when the actual temperature is equal or higher to the value set by parameter 61. (Check Associated Groups) Technical Specifications Power supply 110-230VAC ±10% 50/60Hz, 24-30VDC Rated load current of AC output (resistive load) 2 X 4A / 230VAC Rated load current of DC output (resistive load) 2 X 4A / 30VDC Output circuit power of AC output (resistive load) 2 X 920W (230VAC) Output circuit power of DC output (resistive load) 2 X 96W (24VDC) Power monitoring accuracy P=0-200W, +/-2W; P˃200W, +/-3% Operation temperature -10 ~ 40°C Distance up to 30 meters indoors (depending on building materials) Dimensions (WxHxD) (package) 41,8x36,8x16,9mm (115x96x22) Weight (Brutto with package) 48g (64g) Electricity consumption 0,4W For installation in boxes Ø ≥ 60mm or 2M Switching Relay (2x) Digital temperature sensor range -50.0 ~ 125.0°C, resolution 0.1°C Digital temperature sensor cable length 1000mm * In case of load other than resistive, pay attention to the value of cos φ and if necessary apply load lower than the rated load. Max current for cos φ=0,4 is 2A at 250VAC, 3A at 24VDC. Z-Wave Device Class: BASIC_TYPE_ROUTING_SLAVE GENERIC_TYPE_THERMOSTAT SPECIFIC_TYPE_SETPOINT_THERMOSTAT Z-Wave Supported CommandClasses: COMMAND_CLASS_THERMOSTAT_SETPOINT v2 COMMAND_CLASS_VERSION v1 COMMAND_CLASS_MANUFACTURER_SPECIFIC v1 COMMAND_CLASS_MULTI_CMD v1 COMMAND_CLASS_SENSOR_MULTILEVEL v3 COMMAND_CLASS_ASSOCIATION v1 COMMAND_CLASS_CONFIGURATION v1 COMMAND_CLASS_POWERLEVEL v1 COMMAND_CLASS_METER v3 COMMAND_CLASS_THERMOSTAT_MODE v2 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC v1 COMMAND_CLASS_NO_OPERATION Endpoint 2 (I1): Device Class: GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Command Classes: COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_METER_V3 Endpoint 3 (I2): Device Class: GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Command Classes: COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_METER_V3 COMMAND_CLASS_BASIC The basic command class supports the functions BASIC SET and BASIC GET. Through the function basic SET is possible to set the mode of the module. Basic SET can send the values 0xff which means Auto and 0x00 which means Off. Through the function basic GET is possible to read the mode of the module. The module returns 0xff which means Auto or 0x00 which means Off. COMMAND_CLASS_SENSOR_MULTILEVEL The Flush on/off thermostat supports reading of actual temperature which is 2 bytes long, scale is °C and its precision is 1(it means 0,1°C). COMMAND_CLASS_THERMOSTAT_MODE The Flush heat & cool thermostat supports the following modes:  Mode Off  Mode Auto COMMAND_CLASS_THERMOSTAT_SETPOINT The Flush on/off thermostat supports temperature set point, which is 2 bytes long, scale is °C and its precision is 1(it means 0,1°C). This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from any other manufacturers. All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network. Important disclaimer Z-Wave wireless communication is inherently not always 100% reliable, and as such, this product should not be used in situations in which life and/or valuables are solely dependent on its function. Warning! Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. This user manual is subject to change and improvement without notice. Qubino Goap d.o.o. Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E-mail: [email protected] Tel: +386 5 335 95 00 Web: www.qubino.com Date: 13.04.2015 Document: Qubino_Flush heat & cool thermostat user manual_V1.2_eng Temperature control: Heating Hysteresis Heating On Off Hysteresis Cooling Cooling T actualSP On OnOff Off