Practical Aspects of Thermo-couples
P M V Subbarao
Professor
Mechanical Engineering Department
Correct Use of Themocouples ….
Standard Calibration Setup
Ice-point
The result of the calibration is a table of EMF versus T values.
The integral is never directly evaluated.
Instead a polynomial curve fit to the calibration data gives:
  n
j
n
j
j
j
j T
b
T
b
T
b
b
T
F
E 




 .....
2
2
1
0
0
 


j
t
T
T
AB
AB dT
T
E 
From the same calibration data a curve fit of the form
  n
j
n
j
j
j
j E
c
E
c
E
c
c
E
G
T 0
2
0
2
0
1
0
0 .....





This equation is directly useful for temperature measurements
with thermocouples.
The coefficients of the calibration equations for type J
thermocouples are given in Tables
thermpocouple application and block diagram.ppt
thermpocouple application and block diagram.ppt
Practical Thermocouple Circuits
• The equations given below are now applied to develop
thermocouple circuits that can be used in a laboratory.
• The following ideas are important.
• Compensation with a reference junction in an ice bath;
• Compensation with a reference junction at an arbitrary
temperature;
• Use of zone boxes for large numbers of thermocouples.
  n
j
n
j
j
j
j E
c
E
c
E
c
c
E
G
T 0
2
0
2
0
1
0
0 .....





  n
j
n
j
j
j
j T
b
T
b
T
b
b
T
F
E 




 .....
2
2
1
0
0
Practical Precautions
• The polynomial curve fit relies upon the thermocouple
wire being perfect.
• It must not become decalibrated during the act of making a
temperature measurement.
• Most measurement errors may be traced to one of these
seven primary sources:
Primary Sources of Errors
1. Poor junction connection
2. Decalibration of thermocouple wire
3. Shunt impedance and galvanic action
4. Thermal shunting
5. Noise and leakage currents
6. Thermocouple specifications
7. Documentation
Poor junction connection
• To reach a higher measurement temperature, the joint must
be welded.
• But welding is not a process to be taken lightly.
• Overheating can degrade the wire.
• The welding gas and the atmosphere in which the wire is
welded can both diffuse into the thermocouple metal,
changing its characteristics.
• The difficulty is compounded by the very different nature
of the two metals being joined.
• Commercial thermocouples are welded on expensive
machinery using a capacitive-discharge technique to insure
uniformity.
Decalibration
Leakage Resistance
Laws of Thermocouples
Law of Intermediate Metals
Insertion of an intermediate metal into
a thermocouple circuit will not affect
the emf voltage output so long as the
two junctions are at the same
temperature and the material is
homogeneous.
– Permits soldered and welded joints.
A Demonstration of the Law of Intermediate Metals
3
1 2 5
4
6
emf
Temperature
T ref T 2 and 4
Measured
Emf
Fe
C
Fe (+)
C (-)
P (+)
Tcandle
1
2
T measured
3
5
4
6
Signs of the
materials used
Law of Intermediate Temperatures
If a thermocouple circuit develops a net
emf1-2 for measuring junction
temperatures T1 and T2,
and a net emf2-3 for temperatures T2 and T3,
then it will develop a net voltage of emf1-3 =
emf1-2 + emf2-3 when the junctions are at
temperatures T1 and T3.
emf1-2+ emf2-3= emf1-3
T3 T1
T3 T2
T2 T1
A Demonstration of the Law of Intermediate
Temperatures
emf
T 1 T 2
Fe
C
T 3
emf23
emf1-2+ emf2-3= emf1-3
emf13
emf12
The integrity of a thermocouple system
• The integrity of a thermocouple system can be improved
by following these precautions:
• Use the largest wire possible that will not shunt heat away
from the measurement area.
• If small wire is required, use it only in the region of the
measurement and use extension wire for the region with no
temperature gradient.
• Avoid mechanical stress and vibration which could strain
the wires.
• When using long thermocouple wires, connect the wire
shield to the dvm guard terminal and use twisted pair
extension wire.
• Avoid steep temperature gradients.
• Try to use the thermocouple wire well within its
temperature rating.
• Use a guarded integrating A/D converter.
• Use the proper sheathing material in hostile environments
to protect the thermocouple wire.
• Use extension wire only at low temperatures and only in
regions of small gradients.
• Keep an event log and a continuous record of
thermocouple resistance.
Single and multiplexing
Use of a Zone Box for Multiple Thermocouples
A zone box with a thermistor to measure Tr.
thermpocouple application and block diagram.ppt
Effect of Non-uniform Zone Box Temperature
• A zone box is designed to hold the temperature of all reference
junctions at a uniform and easily measured value.
• For convenience only a limited number of sensors (typically one)
are used to measure the temperature of the reference junctions.
• A special model is to be developed to assess the measurement
error introduced by non-uniformities in zone box temperature.
Common sheathed thermocouple probe
thermpocouple application and block diagram.ppt
thermpocouple application and block diagram.ppt
Thermopile
Temperature Measurement Errors
• Conduction
• Convection
• Radiation
• Response Time
• Noise
• Grounding issues and shorts, especially on metal surfaces

More Related Content

DOCX
Working principle and structure of thermocouple
PPT
Thermocouples temperature measurement.ppt
PPT
Thermocouples it is copied from any random spruce .ppt
PPT
Thermocouples
PPTX
Thermocouples
PPTX
Telecture25).pptx includes diagrams, benefits, challenges, and real-world ex...
PPT
mel705-22 (1).ppt
PPTX
Thermocouple
Working principle and structure of thermocouple
Thermocouples temperature measurement.ppt
Thermocouples it is copied from any random spruce .ppt
Thermocouples
Thermocouples
Telecture25).pptx includes diagrams, benefits, challenges, and real-world ex...
mel705-22 (1).ppt
Thermocouple

Similar to thermpocouple application and block diagram.ppt (20)

PPTX
Electrical Temperature Measurement(2).pptx
PDF
Thermocouple- Metrology& Instrumentation
PPT
Overview of Temperature Measurement.ppt
PPT
Overview of Temperature Measurement devices
PPT
Overview of Temperature Measurement.ppt: Outline
PPTX
All about temperature transmiter.
DOCX
Thermocouple temperature measurement principle and common faults
PPTX
Thermocouple as a Transducer ppt
PPTX
Thermocouples.pptx
PPTX
Thermocouples.pptx
DOCX
Cold junction compensation
PPTX
temperature measurement..............pptx
PPT
Ece 371 jb lecture 3
PPTX
Temperature Measurement Techniques # 3.pptx
PPTX
Thermocouple
PPTX
Thermocouples
PPTX
Thermocouple
PPTX
Thermocouple sensor
PPTX
The Working principle of Thermocouple
PPT
Measurement and Instrumentations of temperature
Electrical Temperature Measurement(2).pptx
Thermocouple- Metrology& Instrumentation
Overview of Temperature Measurement.ppt
Overview of Temperature Measurement devices
Overview of Temperature Measurement.ppt: Outline
All about temperature transmiter.
Thermocouple temperature measurement principle and common faults
Thermocouple as a Transducer ppt
Thermocouples.pptx
Thermocouples.pptx
Cold junction compensation
temperature measurement..............pptx
Ece 371 jb lecture 3
Temperature Measurement Techniques # 3.pptx
Thermocouple
Thermocouples
Thermocouple
Thermocouple sensor
The Working principle of Thermocouple
Measurement and Instrumentations of temperature
Ad

More from bitseeeRandD (12)

PPTX
CScontrolsystems forsingleinputsingle.pptx
PPTX
VCAC2alternating voltage controller topic.pptx
PPTX
ACVC1acvolatgae controllerstopicACV.pptx
PPTX
ppt1 presentation voltage control methhods.pptx
PDF
raspberry pi 3 of digital class room.pdf
PPTX
12180134 lectrical measurements 1 first unit.pptx
PPTX
ev vehicle presentation in the present senario.pptx
PPT
woody bio mass slide presentation of fermentation
PPT
woody biomass presentation Department of Electrical and Electronics Engineering
PPT
QLW C9 India Mr G M Pillai asdfggjjjkjjj
PPTX
Energy University Forum 3_final renwable
PPTX
FET.pptx
CScontrolsystems forsingleinputsingle.pptx
VCAC2alternating voltage controller topic.pptx
ACVC1acvolatgae controllerstopicACV.pptx
ppt1 presentation voltage control methhods.pptx
raspberry pi 3 of digital class room.pdf
12180134 lectrical measurements 1 first unit.pptx
ev vehicle presentation in the present senario.pptx
woody bio mass slide presentation of fermentation
woody biomass presentation Department of Electrical and Electronics Engineering
QLW C9 India Mr G M Pillai asdfggjjjkjjj
Energy University Forum 3_final renwable
FET.pptx
Ad

Recently uploaded (20)

PDF
faiz-khans about Radiotherapy Physics-02.pdf
PDF
anganwadi services for the b.sc nursing and GNM
PDF
Nurlina - Urban Planner Portfolio (english ver)
PDF
African Communication Research: A review
PPTX
Theoretical for class.pptxgshdhddhdhdhgd
PPTX
Power Point PR B.Inggris 12 Ed. 2019.pptx
PPT
hsl powerpoint resource goyloveh feb 07.ppt
PDF
0520_Scheme_of_Work_(for_examination_from_2021).pdf
PPTX
Designing Adaptive Learning Paths in Virtual Learning Environments
PPTX
PLASMA AND ITS CONSTITUENTS 123.pptx
PDF
Chevening Scholarship Application and Interview Preparation Guide
PPTX
Diploma pharmaceutics notes..helps diploma students
PPT
Acidosis in Dairy Herds: Causes, Signs, Management, Prevention and Treatment
PDF
Horaris_Grups_25-26_Definitiu_15_07_25.pdf
PDF
Hospital Case Study .architecture design
PDF
Health aspects of bilberry: A review on its general benefits
PPTX
Neurology of Systemic disease all systems
PDF
Laparoscopic Dissection Techniques at WLH
PDF
fundamentals-of-heat-and-mass-transfer-6th-edition_incropera.pdf
PDF
Diabetes Mellitus , types , clinical picture, investigation and managment
faiz-khans about Radiotherapy Physics-02.pdf
anganwadi services for the b.sc nursing and GNM
Nurlina - Urban Planner Portfolio (english ver)
African Communication Research: A review
Theoretical for class.pptxgshdhddhdhdhgd
Power Point PR B.Inggris 12 Ed. 2019.pptx
hsl powerpoint resource goyloveh feb 07.ppt
0520_Scheme_of_Work_(for_examination_from_2021).pdf
Designing Adaptive Learning Paths in Virtual Learning Environments
PLASMA AND ITS CONSTITUENTS 123.pptx
Chevening Scholarship Application and Interview Preparation Guide
Diploma pharmaceutics notes..helps diploma students
Acidosis in Dairy Herds: Causes, Signs, Management, Prevention and Treatment
Horaris_Grups_25-26_Definitiu_15_07_25.pdf
Hospital Case Study .architecture design
Health aspects of bilberry: A review on its general benefits
Neurology of Systemic disease all systems
Laparoscopic Dissection Techniques at WLH
fundamentals-of-heat-and-mass-transfer-6th-edition_incropera.pdf
Diabetes Mellitus , types , clinical picture, investigation and managment

thermpocouple application and block diagram.ppt

  • 1. Practical Aspects of Thermo-couples P M V Subbarao Professor Mechanical Engineering Department Correct Use of Themocouples ….
  • 2. Standard Calibration Setup Ice-point The result of the calibration is a table of EMF versus T values. The integral is never directly evaluated. Instead a polynomial curve fit to the calibration data gives:   n j n j j j j T b T b T b b T F E       ..... 2 2 1 0 0     j t T T AB AB dT T E 
  • 3. From the same calibration data a curve fit of the form   n j n j j j j E c E c E c c E G T 0 2 0 2 0 1 0 0 .....      This equation is directly useful for temperature measurements with thermocouples. The coefficients of the calibration equations for type J thermocouples are given in Tables
  • 6. Practical Thermocouple Circuits • The equations given below are now applied to develop thermocouple circuits that can be used in a laboratory. • The following ideas are important. • Compensation with a reference junction in an ice bath; • Compensation with a reference junction at an arbitrary temperature; • Use of zone boxes for large numbers of thermocouples.   n j n j j j j E c E c E c c E G T 0 2 0 2 0 1 0 0 .....        n j n j j j j T b T b T b b T F E       ..... 2 2 1 0 0
  • 7. Practical Precautions • The polynomial curve fit relies upon the thermocouple wire being perfect. • It must not become decalibrated during the act of making a temperature measurement. • Most measurement errors may be traced to one of these seven primary sources:
  • 8. Primary Sources of Errors 1. Poor junction connection 2. Decalibration of thermocouple wire 3. Shunt impedance and galvanic action 4. Thermal shunting 5. Noise and leakage currents 6. Thermocouple specifications 7. Documentation
  • 9. Poor junction connection • To reach a higher measurement temperature, the joint must be welded. • But welding is not a process to be taken lightly. • Overheating can degrade the wire. • The welding gas and the atmosphere in which the wire is welded can both diffuse into the thermocouple metal, changing its characteristics. • The difficulty is compounded by the very different nature of the two metals being joined. • Commercial thermocouples are welded on expensive machinery using a capacitive-discharge technique to insure uniformity.
  • 13. Law of Intermediate Metals Insertion of an intermediate metal into a thermocouple circuit will not affect the emf voltage output so long as the two junctions are at the same temperature and the material is homogeneous. – Permits soldered and welded joints.
  • 14. A Demonstration of the Law of Intermediate Metals 3 1 2 5 4 6 emf Temperature T ref T 2 and 4 Measured Emf Fe C Fe (+) C (-) P (+) Tcandle 1 2 T measured 3 5 4 6 Signs of the materials used
  • 15. Law of Intermediate Temperatures If a thermocouple circuit develops a net emf1-2 for measuring junction temperatures T1 and T2, and a net emf2-3 for temperatures T2 and T3, then it will develop a net voltage of emf1-3 = emf1-2 + emf2-3 when the junctions are at temperatures T1 and T3. emf1-2+ emf2-3= emf1-3 T3 T1 T3 T2 T2 T1
  • 16. A Demonstration of the Law of Intermediate Temperatures emf T 1 T 2 Fe C T 3 emf23 emf1-2+ emf2-3= emf1-3 emf13 emf12
  • 17. The integrity of a thermocouple system • The integrity of a thermocouple system can be improved by following these precautions: • Use the largest wire possible that will not shunt heat away from the measurement area. • If small wire is required, use it only in the region of the measurement and use extension wire for the region with no temperature gradient. • Avoid mechanical stress and vibration which could strain the wires. • When using long thermocouple wires, connect the wire shield to the dvm guard terminal and use twisted pair extension wire.
  • 18. • Avoid steep temperature gradients. • Try to use the thermocouple wire well within its temperature rating. • Use a guarded integrating A/D converter. • Use the proper sheathing material in hostile environments to protect the thermocouple wire. • Use extension wire only at low temperatures and only in regions of small gradients. • Keep an event log and a continuous record of thermocouple resistance.
  • 20. Use of a Zone Box for Multiple Thermocouples
  • 21. A zone box with a thermistor to measure Tr.
  • 23. Effect of Non-uniform Zone Box Temperature • A zone box is designed to hold the temperature of all reference junctions at a uniform and easily measured value. • For convenience only a limited number of sensors (typically one) are used to measure the temperature of the reference junctions. • A special model is to be developed to assess the measurement error introduced by non-uniformities in zone box temperature.
  • 28. Temperature Measurement Errors • Conduction • Convection • Radiation • Response Time • Noise • Grounding issues and shorts, especially on metal surfaces