11 changes: 11 additions & 0 deletions docs/changes/newsfragments/8697.breaking
Original file line number Diff line number Diff line change
@@ -0,0 +1,11 @@
The ``current``, ``current_range`` and ``current_limit`` parameters of the ``YokogawaGS200``,
and its ``measure`` parameter in voltage source mode, now use the unit ``A`` instead of ``I``.
The ``ramp_rate`` and ``ramp_step`` parameters now start with the units ``A/s`` and ``A``
instead of ``V/s`` and ``V`` if the instrument is in current source mode when connecting, as
they already did after changing the source mode.

``YokogawaGS200Monitor.delay`` (``measure.delay``) is now in seconds, the unit the instrument
uses, instead of ms. The value was already sent to the instrument unconverted, so
``delay(500)`` set a delay of 500 s despite the ``ms`` unit. The parameter now accepts values
from 0 to 999.999 s in steps of 1 ms, e.g. ``delay(0.5)`` for 500 ms, and returns the delay
as a ``float`` in seconds instead of an ``int`` rounded to whole seconds.
16 changes: 16 additions & 0 deletions docs/changes/newsfragments/8697.improved_driver
Original file line number Diff line number Diff line change
@@ -0,0 +1,16 @@
The remaining parameters of the ``YokogawaGS200`` driver are now annotated with the type of
their value, e.g. ``Parameter[float, Self]``. ``YokogawaGS200Program.count`` is annotated as
``int | Literal["MIN", "MAX"]``: it can be set to ``"MIN"`` or ``"MAX"``, and getting it
always returns an integer, but until it is read again the cached value is the keyword that was
set. The status register parameters return the ``StatusByte``, ``StandardEventRegister``,
``ExtendedEventRegister`` and ``ConditionRegister`` flags as before, and are now annotated as
such.

Fixed the following driver bugs found along the way:

- ``YokogawaGS200.ramp_voltage`` and ``ramp_current`` raised a ``TypeError`` when called with
``ramp_mode="SOFTWARE"``. They now perform the software ramp, and raise a ``ValueError`` if
``ramp_step`` is 0, which would otherwise jump directly to the target.
- A software ramp of the ``YokogawaGS200`` to a target outside the output range of the present
source range now raises before changing the output. Previously it stepped up to the limit of
the range before raising.
91 changes: 90 additions & 1 deletion src/qcodes/instrument/sims/Yokogawa_GS200.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -11,8 +11,29 @@ devices:
r: "QCoDeS Yokogawa Mock,GS200,xxxxxxxx,MOCKFW"
- q: "*OPT?"
r: "NO OPTIONS"
# Status registers, see GS200 User's Manual IM GS210-01EN, 13.3.
# *STB?: RQS (bit 6) and EAV (bit 2)
- &stb
q: "*STB?"
r: "68"
# *ESR?: CME (bit 5)
- &esr
q: "*ESR?"
r: "32"
# :STAT:EVEN?: EOP (bit 7) and SCG (bit 5)
- &stat_even
q: ":STAT:EVEN?"
r: "160"
# :STAT:COND?: RFP (bit 8)
- &stat_cond
q: ":STAT:COND?"
r: "256"
# Only queried when *STB? reports EAV, so always return an error.
- &syst_err
q: ":SYSTem:ERRor?"
r: '-222,"Data out of range"'

properties:
properties: &gs200_properties
mode:
default: "VOLT"
getter:
Expand Down Expand Up @@ -45,15 +66,83 @@ devices:
q: ":SOUR:LEV {:e}"
specs:
type: float
# pyvisa-sim cannot convert MIN/MAX to the step numbers 1/10000 as the
# instrument does, so only set this to integers when reading it back.
program_count:
default: 1
getter:
q: ":PROG:COUN?"
r: "{}"
setter:
q: ":PROG:COUN {}"
Comment thread
jenshnielsen marked this conversation as resolved.
Resolved
auto_level:
default: 0.0
setter:
q: ":SOUR:LEV:AUTO {:e}"
specs:
type: float
# Measurement (/MON option) settings, only used by device 2
measurement_enabled:
default: 0
getter:
q: ":SENS?"
r: "{}"
setter:
q: ":SENS {}"
nplc:
default: "+1.0E+00"
getter:
q: ":SENS:NPLC?"
r: "{}"
setter:
q: ":SENS:NPLC {}"
measurement_delay:
default: "+0.0E+00"
getter:
q: ":SENS:DEL?"
r: "{}"
setter:
q: ":SENS:DEL {}"
measurement_trigger:
default: "READ"
getter:
q: ":SENS:TRIG?"
r: "{}"
setter:
q: ":SENS:TRIG {}"
measurement_interval:
default: "+0.5E+00"
getter:
q: ":SENS:INT?"
r: "{}"
setter:
q: ":SENS:INT {}"

# A GS200 with the /MON (monitoring) option
device 2:
eom:
GPIB INSTR:
q: "\n"
r: "\n"
error: ERROR
dialogues:
- q: "*IDN?"
r: "QCoDeS Yokogawa Mock,GS200,xxxxxxxx,MOCKFW"
- q: "*OPT?"
r: "/MON"
# Same status register and error responses as device 1
- *stb
- *esr
- *stat_even
- *stat_cond
- *syst_err
- q: ":MEAS?"
r: "+1.23450E-03"

properties: *gs200_properties

resources:
GPIB::1::INSTR:
device: device 1
GPIB::2::INSTR:
device: device 2